• Title/Summary/Keyword: 상완골 두

Search Result 39, Processing Time 0.023 seconds

The Short Term Clinical Results of Hemiarthroplasty to Treat Humeral Head Osteonecrosis (상완골 두 비 외상성 골괴사에 시행한 견관절 반 치환술의 단기 추시 결과)

  • Sohn, Kang-Min;Sung, Chang-Meen;Park, Hyung-Bin
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.2
    • /
    • pp.183-189
    • /
    • 2007
  • Introduction: While uncommon, humeral head osteonecrosis is an indication for arthroplasty when the humeral head collapse is advanced. The current authors report the short-term clinical results of 7 hemiarthroplasties to treat humeral head osteonecrosis. Materials and Methods: This study focused on 7 reconstructed shoulders of 5 patients whose humeral head osteonecrosis was treated with hemiarthroplasty. The postulated causes were alcohol-induced (4 cases) and steroidinduced (3 cases). The minimum follow-up was 12 months. This study compared the preoperative and postoperative shoulder pain, range of motion, and ASES scores. The postoperative patient satisfaction was assessed. Results: The level of pain during exercise was reduced from a preoperative average of 7.6 to a postoperative average of 1.9. The range of motion, in terms of forward flexion, abduction, and external rotation, improved from preoperative averages of $105.7^{\circ}$, $80^{\circ}$, and $22.1^{\circ}$ to postoperative averages of $146.6^{\circ}$, $139.3^{\circ}$, and $44.3^{\circ}$, respectively. The ASES scores increased from a preoperative mean of 39.0 to a postoperative mean of 84.1. The patients' ratings of the outcomes were excellent (5 cases) and good (2 cases). Conclusions: These short-term results indicate that hemiarthroplasty is a reliable treatment method for humeral head osteonecrosis improving shoulder pain, range of motion, and patient satisfaction.

Remplissage Procedure (관절경하 극하건 고정술)

  • Kim, Young-Kyu
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.3
    • /
    • pp.169-174
    • /
    • 2010
  • 대다수의 견관절 전방 불안정성에서 관절와에 골 소실이 큰 경우는 Bankart 복원술을 튼튼하게 하였을지라도 상완골두를 지탱할 관절 궁이 감소되어 골에 의한 버팀이 줄어들므로 Bankart 복원이 실패할 가능성이 높다. 따라서 관절와 결손이나 상완골 두 결손이 큰 경우 정확한 측정으로 결손의 범위를 파악하여야 하며, 관절와 결손이 25% 이상이거나 상완 골 두 결손이 30% 이상인 경우 추가적인 수술적 처치가 요하여 최근 보고되고 있는 Latarjet 술식이나 관절경적 Remplissage 술식을 시행하는 것이 바람직하다.

  • PDF

The Short Term Clinical Follow-up Study for Hemiarthroplasty in Proximal Humeral Fracture (상완골 근위부 분쇄 골절에서의 상완골 두 치환술의 단기 추시 결과)

  • Sung, Chang-Meen;Cho, Se-Hyun;Jung, Soon-Taek;Hwang, Sun-Chul;Park, Hyung-Bin
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.92-98
    • /
    • 2007
  • Introduction: The treatment of proximal humeral fracture is traditionally determined by Neer's classification system. The severely displaced three-part or four-part fracture is an indication for primary hemiarthroplasty. The current authors report the clinical results of 10 patients who received hemiarthroplasty for proximal comminuted fractures. The minimum follow-up period was 12 months. Materials and Methods: The current authors studied 10 patients who, between July 1999 and March 2005, each received hemiarthroplasty for a proximal humeral fracture of one shoulder. According to Neer's classification system, 5 of the patients had three-part fractures, and 5 of the patients had 4-part fractures. The mean interval between trauma and hemiarthroplasty was 6.1 days. The mean age of the 6 female and 4 male patients was 67.4 years(range: 56 to 76). Shoulder function was evaluated using the Constant score, the Simple Shoulder Test, and the modified UCLA score. Results: The mean Constant score was 51.4(range: 34 to 60). The mean modified SST score was 7.8 out of 12 tasks. Excluding the one patient who had also sustained an axillary artery rupture and a brachial plexus injury after the initial trauma, the mean Constant score for the remaining 9 patients was 53.5(range: 44 to 60), and the mean SST score was 7.2 tasks. The modified UCLA score averages for pain, function, and active forward flexion and strength were, respectively, 8.2($6{\sim}10$), 6.6($2{\sim}8$), and 6.9($4{\sim}8$). The total UCLA score was an average of 21.7($12{\sim}26$). Patients' the modified UCLA ratings were as follows: Excellent: 3, Good: 6, and Poor: 1. The patient with the poor outcome was the one who had also sustained the neurovascular injury. Patient's subjective satisfaction rating were as follows: Excellent: 2, Good: 7, and Poor: 1. Conclusion: Based on short term follow-up results, this study indicates that hemiarthroplasty is the treatment of choice for proximal humeral fractures on which it would be difficult to perform open reduction and internal fixation. Hemiarthroplasty is a useful treatment modality to prevent shoulder stiffness and to allow daily living tasks in elderly patients. However, restoration of muscle power and range of joint motion were not recovered satisfactorily.

Shoulder Arthropalsty for Fractures (골절에서의 견관절 인공관절술)

  • 전재명
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2003.11a
    • /
    • pp.175-180
    • /
    • 2003
  • 상완골 근위부 골절의 치료를 위해서 실시하는 상완골 두 치환술은 고난도의 수술이다. 그러나 수술 수기에 만전을 기하고 골절을 위해서 특별하게 고안된 치환물을 사용하면 통증을 해소되는 것은 물론이며 대부분의 견관절 기능도 회복이 가능하다고 생각한다. 또한 보다 좋은 결과를 얻기 위해서는 치환물과 수술 수기 등에 대해서 지속적인 개선이 매우 중요하다고 생각한다.

  • PDF

Comparison of Radiologic and Clinical Results between Locking Compression Plate and Unlocked Plate in Proximal Humerus Fractures (근위 상완골 골절에서 잠김 압박 금속판과 비잠김 금속판 고정의 방사선학적 임상적 추시 결과 비교)

  • Kim, Jae-Hwa;Lee, Yun-Seok;Ahn, Tae-Keun;Choi, Jung-Pil
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.143-149
    • /
    • 2008
  • Purpose: The purpose of this study is to compare the results of using a locking compression plate and an unlocked plate for treating proximal humeral fractures. Materials and Methods: This study was based on 20 patients who underwent plate fixation for proximal humeral fractures out of the 87 patients with proximal humeral fractures and who were admitted from 2003 to 2007 in our hospital. Of the 20 patients, 10 were treated with a locking compression plate and the other 10 were treated with an unlocked plate. Each group was evaluated according to the humeral neck shaft angle, the period until bony union, the complications and the Constant score. The humeral neck shaft angle was based on plain x-rays taken immediately after the operation and at 6 months postoperatively. The Constant score was evaluated on the last visit to our clinic. Results: There was no significant statistical difference between the two groups in terms of the neck shaft angle, the period until bony union and the Constant score. Yet, there were three cases of screw migration in the unlocked plate group. Conclusion: There was no significant difference between the two groups in terms of the neck shaft angle, the period until bony union and the Constant score. The locking compression plate is considered to achieve more effective fixation for proximal humerus fractures because there were less complications such as screw migration.

Traumatic Posterior Dislocation of the Shoulder with Ipsilateral Humeral Surgical Neck Fracture in a Child - A Case Report - (소아에서 동측 상완골 외과적 경부 골절을 동반한 외상성 견관절 후방 탈구 - 증례 보고 -)

  • Kang, Suk;Chung, Phil-Hyun;Kim, Jong-Pil;Kim, Young-Sung;Lee, Ho-Min;Kim, Jong-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.80-83
    • /
    • 2011
  • Purpose: Traumatic posterior dislocation of the shoulder in a child is extremely rare, and posterior dislocation of the shoulder concomitant with ipsilateral humeral surgical neck fracture has not been reported in a child previously in Korea. Materials and Methods: The authors treated a 10-year-old with posterior dislocation of left shoulder and an ipsilateral humeral surgical neck fracture, that occurred during Taekwondo practice, by open reduction of the shoulder and pin fixation under general anesthesia. Results: A normal range of motion with complete union and good remodeling was achieved without redislocation or avascular necrosis of humeral head at 1 year after surgery. Conclusion: The authors report a successfully treated case of traumatic posterior dislocation of the shoulder with an ipsilateral humeral surgical neck fracture in child.

A Study of the Capsuloligamentous Anatomy of the Glenohumeral Joint Using Magnetic Resonance Imaging and Three-Dimensional Imaging. Dynamic In Vivo Study (자기공명 영상 및 3차원 영상을 이용한 견관절 관절낭-인대의 해부학적 연구. 역동학적 생체연구)

  • Park Tae-Soo;Choi Il-Yong;Joo Kyung-Bin;Kim Sun-Il;Kim Jun-Sic;Paik Doo-Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.2
    • /
    • pp.154-158
    • /
    • 2000
  • Purpose : The purpose of this study is to demonstrate changes in the orientation ortho glenohumeral ligaments(GHL) in different degrees of abduction and rotation of the normal healthy individuals. Materials and Methods : Saline Magnetic Resonance(MR) arthrography of nine consecutive shoulders of normal healthy adults were checked. At that time, MR images were obtained in three different positions of abduction and external rotation($0^{\circ}C\;and\;0^{\circ},\;45^{\circ}C\;and\;25^{\circ}C,\;90^{\circ}$ and maximum, respectively). From a series of consecutive MRI, three-dimensional images were reconstructed after detecting the location of the middle glenohumeral ligament(MGHL) and the inferior glenohumeral ligament(IGHL) using workstation computer. Results : The shape of the MGHL was taken in double curved, and straight, and finally curved again in three different positions of the shoulder in sequence. On the other hand, the shape of the IGHL was obliquely positioned, and curvilinear, and finally straight and extended at lower part of the anterior surface of the humeral head. Conclusions : At $45^{\circ}$ of abduction and $25^{\circ}$ of external rotation, and at $90^{\circ}$ of abduction and maximal external rotation of the shoulder, the MGHL and the IGHL had the role of the most important static stabilizer of the glenohumeral joint repectively.

  • PDF

Operative Treatment with Locking Compression Plate (LCP) in Proximal Humerus Fracture (잠김 압박 금속판을 이용한 상완골 근위부 골절의 치료)

  • Ha, Sung-Sik;Kim, Jae-Young;Hong, Ki-Do;Sim, Jae-Chun;Kang, Jung-Ho;Park, Kwang-Hee
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.137-142
    • /
    • 2008
  • Purpose: To evaluate the clinical and radiographic results of the treatment of a proximal humerus fracture with a locking compression plate(LCP). Materials and Methods: This study reviewed the results of 24 cases of a proximal humerus fracture treated with a LCP from January 2005 to April 2007, after a follow up of more than 12 months. There were 8 males and 16 females with a mean age of 68.9(33-90) years. The clinical results were evaluated using the Neer's evaluation criteria, and the radiographic results were evaluated using the bone union time and Paavoleinen method. Results: The mean time for bone union was 11.9 weeks. Using the Neer's functional evaluation, 21 cases of the 24 patients (87%) showed excellent or satisfactory results. Twenty two cases (91%) showed good results according to the Paavoleinen method. The complications encountered were metal failure (1 patient), AVN of the humeral head (1 patient) and joint stiffness (1 patient). Conclusion: The LCP demonstrated good results in the treatment of a proximal humerus fracture and has relatively fewer complications than other internal fixators.

Treatment of Two- and Three-Part Fracture of Proximal Humerus using LCP (잠김 압박 금속판(LCP)을 이용한 상완골 근위부 이분 및 삼분 골절의 치료)

  • Shin, Sung-Il;Song, Kyung-Won;Lee, Jin-Young;Lee, Seung-Yong;Kim, Gab-Rae;Hyun, Yoon-Suk;Park, Deok-Yong
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.2
    • /
    • pp.204-211
    • /
    • 2007
  • Purpose: To evaluate the result and complication of treatment using Locking Compression Plate (LCP) for fracture of proximal humerus. Materials and Methods: Between 2004 and 2006, 21 patients with two-part and three-part fractures of the proximal humerus were treated by LCP fixation. Their average age was 54.9 years. Postoperative mean follow-up period was 22.9 months. The reduction was qualified and complication were assessed with final radiographs. The functional outcome was evaluated by Neer's rating system. Results: By Neer's functional evaluation, mean score of shoulder function was 86.3 and 18 case (86%) had excellent or satisfactory results. There was one case of nonunion but no infection or avascular necrosis of the humeral head. No correlation was found between the final result and the type of fracture, age, gender or quality of reduction. Conclusion: We obtained satisfactory result of LCP fixation for fracture of proximal humerus in this study. LCP fixation for proximal humerus fracture is a reliable method to obtain satisfactory reduction, rigid fixation and early exercise.