• Title/Summary/Keyword: 상완골 골절

Search Result 131, Processing Time 0.03 seconds

Pathologic Fracture of Unicameral Bone Cyst (단순 골낭종에서 발생한 병적 골절)

  • Choo, Suk-Kyu;Lee, Hee-Du;Oh, Hyoung-Keun
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.17 no.2
    • /
    • pp.58-64
    • /
    • 2011
  • Purpose: The purpose of this study is to observe unicameral bone cyst (UBC) outcome after the fracture has healed and if there is any identifiable prognostic factors. Materials and Methods: 13 UBC patients with pathologic fracture from 2001 to 2010 were reviewed. The mean follow up were 26 months (3-90 months). There were 11 male and 2 female patients and the mean age of the patients were 10.2 years old (6-16 years). 9 involved proximal humerusand 2 involved humerus shaft and 1 involved proximal femur and 1 involved proximal tibia. The treatment of UBC fracture was conservative cast application to heal the fracture initially, and 1 patient was treated with primary auto bone graft and open reduction with internal fixation. 5 patients were treated with steroid injection during follow up period and 2 patients with auto bone graft. We analyzed the change of UBC during pathologic fracture healing period and prognostic factor about age, the size of UBC, the involvement of physis. Results: The mean duration of the fracture healing was 8.2 months. Complete healing were occurred at 4 patients (31%). No statiscal difference was checked with age about UBC healing (p=0.42). But, more larger size about UBC and more closer to physis, the healing was difficult (p=0.05, p=0.03). Conclusion: While pathologic fracture of UBC was possibly healed, active treatment should be applied especially those cysts that involvescloser area of the physis or large size.

Clinical and Radiographical Follow-up for Residual Displacement of Fracture Fragments after Interlocking Intramedullary Nailing in Humeral Shaft Fractures (상완골 간부 골절에서 교합성 골수강 내 금속정 고정 후 잔존한 골절편 전위에 대한 임상적, 방사선학적 추시)

  • Yum, Jae-Kwang;Lim, Dong-Ju;Jung, Eui-Yub;Sohn, Su-Een
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.2
    • /
    • pp.107-114
    • /
    • 2013
  • Purpose: This study is designed to evaluate the clinical and radiographical results for the displacement of fracture fragments after interlocking intramedullary nailing in humeral shaft fractures. Materials and Methods: We retrospectively reviewed the results of 8 cases of humeral shaft fractures that have displacements of over 10 mm and under 20 mm after interlocking intramedullary nailing between July 2004 and August 2011. The mean age was 54.1 years (range, 43 to 70 years) and there were 3 male and 5 female patients. Radiographically, the time to bony union, change of displacement and angulation of the fracture site, and degree of improvement of these two factors were measured. Clinically, the range of motion of shoulder and elbow joints, postoperative pain and complications were evaluated. Results: All cases showed complete bony union in last follow-up. The mean time to bony union was 16.1 weeks. At the last follow-up, almost all cases had normal range of motion of shoulder and elbow joints. But, one case had stiffness of shoulder joint. Therefore, arthroscopic capsular release and manipulation was performed. One case had transient shoulder pain and the other case had transient elbow pain. In the two cases, pull-out of proximal interlocking screw were noted, but they finally had bony union. Conclusion: Although considerable displacement of fracture fragments after interlocking intramedullary nailing in humeral shaft fractures was present, we had excellent radiographical and clinical outcomes. Therefore, an additional procedure, such as open reduction or another fixation for the fracture site, was not necessary.

Operative Treatment of Displaced Proximal Humerus Fractures with the Angular Stable Locking Compression Plate (각안정 잠김 압박 금속판을 이용한 전위된 근위 상완골 골절에 대한 수술적 치료)

  • Kim, Dong-Wook;Kim, Chong-Kwan;Jung, Sung-Won;Kim, Hyeon-Soo
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.27-34
    • /
    • 2011
  • Purpose: We examined the clinical and radiological outcomes for displaced proximal humerus fractures that were treated with a PHILOS angular stable plate. Materials and Method: Forty four patients who underwent surgery between March 2007 and February 2010 were included in this study. All the cases were followed up for an average of 12 months. All the patients were examined and interviewed using the Visual Analog Scale (VAS) score, the Constant score and standardized X-rays to check the neck-shaft angle (NSA) and the presence of medial support. Results: The average Visual Analog Scale score was 2.8 points and the average Constant score was 70.5 points. The average neck shaft angle was $122.5^{\circ}$ and this was statistically significant between the good result group and the poor result group. There were 36 cases of the presence of medial support and 8 cases of the absence of medial support and the difference was statistically significant. Complications such as fixation failure happened in 12 cases. Conclusion: PHILOS angular stable plate fixation as an operative treatment for displaced proximal humerus fractures is a good and reliable treatment option.

Posterior Shoulder Dislocation with a Greater Tuberosity Fracture and Total Rupture of Rotator Cuff - A Case Report - (상완골 대결절 골절 및 회전근 개 전 파열이 동반된 견관절 후방 탈구 - 증례 보고 -)

  • Shin, Sung-Ryong;Kim, Do-Young;Lee, Sang-Soo;Ryu, Yun-Sik;Jung, Un-Seob;Choi, Hyun-Seok
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.2
    • /
    • pp.227-231
    • /
    • 2007
  • A posterior shoulder dislocation with a fracture is rare. Most fractures are impression fractures of the humeral head or lesser tuberosity fractures. However, there are no reports of a complete rupture of the rotator cuff with a combined posterior glenohumeral dislocation. We report a unique case of a posterior shoulder dislocation with an avulsion fracture of the greater tuberosity and a complete rupture of infraspinatus, teres minor and subscapularis tendons, which were treated surgically.

A case study of radial nerve injury associated with humerus shaft fracture (상완골 간부 골절에 동반된 요골신경손상에 대한 치험 1례)

  • Lee, Jae-Eun;Lee, Jung-Min;Oh, Min-Seok
    • Journal of Haehwa Medicine
    • /
    • v.23 no.1
    • /
    • pp.157-166
    • /
    • 2014
  • Objective : The purpose of this study is to report the patient with radial nerve injury associated with humerus shaft fracture, who was improved by Korean medical treatments. Methods : The patient was treated by Jungsongouhyul pharmacopuncture, electrical stimulation therapy, physical therapy, and herbal medicine according to "Locating Yang brightness meridians" theory. Coding result, Numeric rating scale(NRS) and digital grip dynamometer were used to evaluate the wrist drop, numbness of fingers and grip power. Results : The patient showed the first sign of recovery after 6 weeks from onset. After 9 weeks from onset, the patient could perform delicate manual activity. Grip power showed noticeable improvement as well as coding result and NRS. Conclusions : The results suggest that providing Korean medical treatments according to "Locating Yang brightness meridians" theory is a good method for treating radial nerve injury associated with humerus shaft fracture. But further studies are required to concretely prove the effectiveness of this method for treating radial nerve injury associated with humerus fracture.

Shoulder Replacement Arthroplasty after Failed Proximal Humerus Fracture (상완골 근위부 골절의 치료 실패 후 견관절 치환술)

  • Park, Jin-Young;Seo, Beom-Ho;Lee, Seung-Jun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.2
    • /
    • pp.110-119
    • /
    • 2019
  • Proximal humerus fracture can be defined as a fracture that occurs in the surgical neck or proximal part of the humerus. Despite the appropriate treatment, however, various complications and sequelae can occur, and the treatment is quite difficult often requiring surgical treatment, such as a shoulder replacement. The classification of sequelae after a proximal humerus fracture is most commonly used by Boileau and can be divided into two categories and four types. Category I is an intracapsular impacted fracture that is not accompanied by important distortions between the tuberosities and humeral head. An anatomic prosthesis can be used without greater tuberosity osteotomy. In category I, there are type 1 with cephalic collapse or necrosis with minimal tuberosity malunion and type 2 related to locked dislocation or fracture-dislocation. Category II is an extracapsular dis-impacted fracture with gross distortion between the tuberosities and the humeral head. To perform an anatomic prosthesis, a tuberosity osteotomy should be performed. In category II, there are type 3 with nonunion of the surgical neck and type 4 with severe tuberosity malunion. In type 1, non-constrained arthroplasty (NCA) without a tuberosity osteotomy should be considered as a treatment. On the other hand, reverse shoulder arthroplasty (RSA) should be considered if types 1C or 1D accompanied by valgus or varus deformity or severe fatty degeneration of the rotator cuff. In general, the results are satisfactory when NCA is performed in type 2 sequelae. On the other hand, RSA can be considered as an option when there is no bony defect of the glenoid and a defect of the rotator cuff is accompanied. In type 3, it would be effective to perform internal fixation with a bone wedge graft rather than shoulder replacement arthroplasty. Recent reports on the results of RSA are also increasing. On the other hand, recent reports suggest that good results are obtained with RSA in type 3. In type 4, RSA should be considered as a first option.

The Results of Ender Nailing for the Proximal Humerus Fractures - Radiological Evaluation - (상완골 근위부 골절의 Erlder 정을 이용한 치료 결과-방사선학적 분석 -)

  • Park Jin Soo;Chung Moon Sang;Yoon Kang Sub;Baek Goo Hyun;Lee Ji Ho;Kang Seung Baek;Kim Dong Wook
    • Clinics in Shoulder and Elbow
    • /
    • v.2 no.2
    • /
    • pp.187-198
    • /
    • 1999
  • Purpose: The authors compared the results of Ender nailing for the proximal humerus fractures with those of the conservative methods radiographically. Materials and Method: Nine patients(mean age: 69 years.) received Ender nailing, and the other nine patients, conservative treatments(mean age: 73 years). All fractures were 2 part fractures. The Ender nails were inserted either through posterior elbow approach or transepicondylar approach. A simple Velpeau bandage was applied to the conservative treatment group. The average follow-up was 15 months. Results: The initial status of the anatomical reduction, i.e., the values of the medial shift, overlapping and the varus agulation, were little changed at follow-up radiographs in both the Ender nailing group and the conservative treatment group. There was no significant difference for the status of anatomical reduction between the Ender nailing group and the conservative treatment group. The stability of fixation by Ender nails, i.e., the degree of fanning out of the nails was poor in most cases. Not a few problems/complications happened in cases of Ender nailing group; back­ing out of the nail in three cases, penetration of the nails into the humeral heads in 3, fractures or cracking of the humerus around the nail insertion area in 4 and reduction loss in one. Conclusion: We could not get better results with the use of Ender nail. We use no longer Ender nails for the proximal humerus fractures. Further studies are needed for the better option for the proximal humerus fractures.

  • PDF

Comparison Study of Different Approach (Deltoid Splitting Approach and Delto-pectoral Interval Approach) for Proximal Humeral Fractures (근위 상완골 골절의 수술적 치료에서 삼각근 분할 도달법과 삼각 대흉간 도달법의 임상적, 방사선학적 추시 결과 비교)

  • Kim, Seung-Hee;Dan, Jinmyoung;Kim, Byoung-Kook;Lee, Yun-Seok;Kim, Hyoeng-Jung;Ryu, Keun-Jeong;Lee, Jin-Hyun;Kim, Jae-Hwa
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.1
    • /
    • pp.17-26
    • /
    • 2013
  • Purpose: A comparison of the radiographic and the clinical outcomes between two different surgical approaches-Deltoid splitting and Delto-pectoral interval-on the proximal humerus fractures treated by locking compressive plate (LCP), is done. Materials and Methods: Medical records and pre- and postoperative radiographs were reviewed retrospectively for 75 adult patients who underwent surgical fixations with locking compressive plates from May 2005 to December 2011. Patients were divided into two groups according to the surgical methods. Differences in the neck-shaft angle between immediate postoperative period and final follow-up were compared between the two groups. Differences in constant score and Korean shoulder score (KSS) between affected arms and contralateral arms at final follow-up were also compared. Results: The differences in the neck-shaft angle between immediate postoperative period and at final follow-up was 12.04 degrees on average in Deltoid splitting approach and 10.20 degrees in Delto-pectoral interval approach, which was not statistically significant. Differences in constant score/KSS between the affected arm and the contralateral arm were 13.78/22.74 points in deltoid-splitting approach on average and 19.41/31.13 points in Delto-pectoral interval approach, showing that deltoid-splitting approach is significantly superior. Conclusion: Deltoid-splitting approach showed better functional outcomes in the fracture reduction and internal fixation using LCP for the treatment of unstable proximal humerus fractures.