• Title/Summary/Keyword: 상악골

Search Result 696, Processing Time 0.026 seconds

Three dimensional photoelastic study on the initial stress distributions of alveolar bone when retracted by lingual K-loop archwire (Lingual K-loop archwire를 이용한 발치공간 폐쇄시 초기응력 분포에 대한 3차원 광탄성학적 연구)

  • Byun, Bo-Ram;Kim, Sik-Sung;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.32 no.5 s.94
    • /
    • pp.343-353
    • /
    • 2002
  • This study was designed to investigate the stress distribution of alveolar bone in case of on masse retraction with lingual K-loop archwire using the 3-dimensional photoelastic stress analysis followed by stress freezing process. Lingual K-loop archwire which had loop in 15mm height was used and activated by retraction force of 350gm per each side. The results were as follows 1. Central incisor : As the closer side to crown, the larger tensile stress was distributed at both mesial and labial surfaces and the larger compressive stress was distributed at distal surface. As the closer side to root apex, the larger compressive stress was distributed at lingual surface. The compressive stress was distributed at root apex. 2. Lateral incisor : The tensile stress was distributed at the coronal side of mesial surface. The compressive stress was distributed at distal surface. As the closer side to crown, the larger tensile stress was distributed at labial surface. The tensile stress was distributed at coronal side and the compressive stress was distributed at apical side of lingual surface. The compressive stress was distributed at root apex. 3. Canine The tensile stress was distributed at coronal side and the compressive stress was distributed at apical side of mesial surface. The tensile stress was distributed at distal surface. As the closer side to crown, the larger tensile stress was distributed at both mesial and distal surfaces. The compressive stress was distributed at root apex. 4. Second premolar : The tensile stress was distributed at mesial surface. The compressive stress was distributed at coronal side and the tensile stress was distributed at apical side of distal surface. The compressive stress was distributed at coronal side of buccal surface. As the closer side to crown, the larger tensile stress was distributed at lingual surface. The compressive stress was distributed at root apex. 5. First molar . As the closer side to crown, the larger tensile stress was distributed at both mesial and distal surfaces. No stress was distributed at buccal surface and palatal root apex. As the closer side to crown, the larger tensile stress was distributed at both lingual surfaces. The compressive stress was distributed a4 buccal root apexes. 6. Second molar The compressive stress was distributed at all root apexes. As the closer side to crown, the larger compressive stress was distributed at both mesial and lingual surfaces, and the larger tensile stress at both distal and buccal surfaces. Transverse bowing effect was observed in on-masse retraction with lingual K-loop archwire, however vertical towing effect was not. Rather, reverse vortical bowing effect was developed.

Clinical Evaluation of Guided Bone Regeneration Using 3D-titanium Membrane and Advanced Platelet-Rich Fibrin on the Maxillary Anterior Area (상악 전치부 3D-티타늄 차폐막과 혈소판농축섬유소를 적용한 골유도재생술의 임상적 평가)

  • Lee, Na-Yeon;Goh, Mi-Seon;Jung, Yang-Hun;Lee, Jung-Jin;Seo, Jae-Min;Yun, Jeong-Ho
    • Implantology
    • /
    • v.22 no.4
    • /
    • pp.242-254
    • /
    • 2018
  • The aim of the current study was to evaluate the results of horizontal guided bone regeneration (GBR) with xenograf t (deproteinized bovine bone mineral, DBBM), allograf t (irradiated allogenic cancellous bone and marrow), titanium membrane, resorbable collagen membrane, and advanced platelet-rich fibrin (A-PRF) in the anterior maxilla. The titanium membrane was used in this study has a three-dimensional (3D) shape that can cover ridge defects. Case 1. A 32-year-old female patient presented with discomfort due to mobility and pus discharge on tooth #11. Three months after extracting tooth #11, diagnostic software (R2 GATE diagnostic software, Megagen, Daegu, Korea) was used to establish the treatment plan for implant placement. At the first stage of implant surgery, GBR for horizontal augmentation was performed with DBBM ($Bio-Oss^{(R)}$, Geistlich, Wolhusen, Switzerland), irradiated allogenic cancellous bone and marrow (ICB $cancellous^{(R)}$, Rocky Mountain Tissue Bank, Denver, USA), 3D-titanium membrane ($i-Gen^{(R)}$, Megagen, Daegu, Korea), resorbable collagen membrane (Collagen $membrane^{(R)}$, Genoss, Suwon, Korea), and A-PRF because there was approximately 4 mm labial dehiscence after implant placement. Five months after placing the implant, the second stage of implant surgery was performed, and healing abutment was connected after removal of the 3D-titanium membrane. Five months after the second stage of implant surgery was done, the final prosthesis was then delivered. Case 2. A 35-year-old female patient presented with discomfort due to pain and mobility of implant #21. Removal of implant #21 fixture was planned simultaneously with placement of the new implant fixture. At the first stage of implant surgery, GBR for horizontal augmentation was performed with DBBM ($Bio-Oss^{(R)}$), irradiated allogenic cancellous bone and marrow (ICB $cancellous^{(R)}$), 3D-titanium membrane ($i-Gen^{(R)}$), resorbable collagen membrane (Ossix $plus^{(R)}$, Datum, Telrad, Israel), and A-PRF because there was approximately 7 mm labial dehiscence after implant placement. At the second stage of implant surgery six months after implant placement, healing abutment was connected after removing the 3D-titanium membrane. Nine months after the second stage of implant surgery was done, the final prosthesis was then delivered. In these two clinical cases, wound healing of the operation sites was uneventful. All implants were clinically stable without inflammation or additional bone loss, and there was no discomfort to the patient. With the non-resorbable titanium membrane, the ability of bone formation in the space was stably maintained in three dimensions, and A-PRF might influence soft tissue healing. This limited study suggests that aesthetic results can be achieved with GBR using 3D-titanium membrane and A-PRF in the anterior maxilla. However, long-term follow-up evaluation should be performed.

Marginal bone loss between internal- and external- abutment connection type implants placed in the first molar area (제1대구치 위치에 식립된 단일 임플란트의 지대주 연결 유형에 따른 임플란트 주위골 흡수)

  • Seok-Hyun Lee;Eun-Woo Lee;Ha-Na Jung;Ok-Su Kim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.1
    • /
    • pp.32-44
    • /
    • 2023
  • Purpose: The purpose of this study was to investigate the effect of implant connection type on marginal bone loss (MBL) and to analyze the factors that affect MBL. This study focuses on single implants planted in the upper and lower first molar area. Materials and Methods: A total of 87 implants from 68 patients were tracked for a period over 5 years. There were 57 external connection type (EC) implants and 30 internal connection type (IC) implants in 38 males and 30 females. The MBL and EA were measured from intraoral radiograph images taken after 5 years at most. Results: Significant difference in MBL between EC and IC type was observed in patients without GBR or diabetes. Patients without GBR exhibited an MBL of -0.065 ± 0.859 mm in EC type and -0.627 ± 0.639 mm in IC type (P = 0.025). Using multiple regression analysis, a statistically significant negative correlation was observed between MBL and conditions including implant-abutment connection type (β = -0.303), diabetes (β = -0.113), emergence angle > 30° (β = -0.234), and age (β = -0.776). Conclusion: Within this results, IC type implants had less MBL than EC type, and implant prosthesis with emergence angle over 30° showed greater MBL. To minimize the MBL of the implant and ensure implant stability, careful consideration should be given to the EA of implant prosthesis and its connection type.

Factors influencing the axes of anterior teeth during SWA on masse sliding retraction with orthodontic mini-implant anchorage: a finite element study (교정용 미니 임플랜트 고정원과 SWA on masse sliding retraction 시 전치부 치축 조절 요인에 관한 유한요소해석)

  • Jeong, Hye-Sim;Moon, Yoon-Shik;Cho, Young-Soo;Lim, Seung-Min;Sung, Sang-Jin
    • The korean journal of orthodontics
    • /
    • v.36 no.5
    • /
    • pp.339-348
    • /
    • 2006
  • Objective: With development of the skeletal anchorage system, orthodontic mini-implant (OMI) assisted on masse sliding retraction has become part of general orthodontic treatment. But compared to the emphasis on successful anchorage preparation, the control of anterior teeth axis has not been emphasized enough. Methods: A 3-D finite element Base model of maxillary dental arch and a Lingual tipping model with lingually inclined anterior teeth were constructed. To evaluate factors influencing the axis of anterior teeth when OMI was used as anchorage, models were simulated with 2 mm or 5 mm retraction hooks and/or by the addition of 4 mm of compensating curve (CC) on the main archwire. The stress distribution on the roots and a 25000 times enlarged axis graph were evaluated. Results: Intrusive component of retraction force directed postero-superiorly from the 2 mm height hook did not reduce the lingual tipping of anterior teeth. When hook height was increased to 5 mm, lateral incisor showed crown-labial and root-lingual torque and uncontrolled tipping of the canine was increased.4 mm of CC added to the main archwire also induced crown-labial and root-lingual torque of the lateral incisor but uncontrolled tipping of the canine was decreased. Lingual tipping model showed very similar results compared with the Base model. Conclusion: The results of this study showed that height of the hook and compensating curve on the main archwire can influence the axis of anterior teeth. These data can be used as guidelines for clinical application.

A CLINICAL STUDY ON MANDIBULAR MOVEMENT AFTER ORTHOGNATHIC SURGERY (악교정 수술환자의 술전후 하악운동 양상변화에 관한 임상적 연구)

  • Baek, Sang-Heum;Jang, Hyun-Jung;Lee, Sang-Han;Kim, Hyun-Soo;Cha, Doo-Won
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.3
    • /
    • pp.239-249
    • /
    • 2001
  • The purpose of this study is to evaluate the relationship of the factors which could be influenced by orthognathic surgery especillay SSRO. We measured the amounts of the maximum opening, lateral movements, maximum velocity and pattern of mandibular path during the opening and closing of mandible at the following times ; preoperative, 1 month after operation, 6 months after operation respectively using MKG. And the results were compared according to the categorized subgroups. Following results were obtained : 1. The change of the amounts of mandibular lateral movement and maximum opening velocity were statistically different between male and female (p<0.05), but the others were not. 2. According to the method of operation, there was no difference in the change of the mandibular movements between the group of SSRO and SSRO plus LeFort I osteotomy (p>0.05). 3. According to the amounts of mandibular movement, the recovery of left lateral movement of the group of $6{\sim}10mm$ was better than the other groups (p<0.05). 4. In the frontal pattern of the opening and closing of the mandible, the complex deflected type (F5), simple deflected type (F4), complex deviated type (F3), simple deviated type (F2), straight type (F1) were obtained in order at the time of preoperative, simple deflected type, simple deviated type, complex deviated type, straight type, complex deflected type in order at the time of 1 month after surgery, and the result at the time of 6 months after surgery was the same with that of the time of preoperative. In the sagittal pattern, non-coincident type (S2) was predominant at the time of preoperative, and coincident type (S1) was predominant at the time of 1 month after surgery. After 6 months, the result was also the same with that of the preoperative in sagittal pattern. 5. There was not a statistical difference in the change of the mandibular movement between group of presence of the preoperative TMJ symptoms and non-presence group (p>0.05). 6. There was not a statistical difference in the change of the mandibular movement between repositioning device applied group and non-applied group (p>0.05). 7. Sixty three percents of the patients who had preoperative TMJ symptoms were improved after surgery and preoperative TMJ symptoms were more improved after operation in the repositioning device non-applied group statistically (p<0.05).

  • PDF

Clinical and radiographic evaluation of $Neoplan^{(R)}$ implant with a sandblasted and acid-etched surface and external connection (SLA 표면 처리 및 외측 연결형의 국산 임플랜트에 대한 임상적, 방사선학적 평가)

  • An, Hee-Suk;Moon, Hong-Suk;Shim, Jun-Sung;Cho, Kyu-Sung;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.125-136
    • /
    • 2008
  • Statement of problem: Since the concept of osseointegration in dental implants was introduced by $Br{{\aa}}nemark$ et al, high long-term success rates have been achieved. Though the use of dental implants have increased dramatically, there are few studies on domestic implants with clinical and objective long-term data. Purpose: The aim of this retrospective study was to provide long-term data on the $Neoplan^{(R)}$ implant, which features a sandblasted and acid-etched surface and external connection. Material and methods: 96 $Neoplan^{(R)}$ implants placed in 25 patients in Yonsei University Hospital were examined to determine the effect of the factors on marginal bone loss, through clinical and radiographic results during 18 to 57 month period. Results: 1. Out of a total of 96 implants placed in 25 patients, two fixtures were lost, resulting in 97.9% of cumulative survival rate. 2. Throughout the study period, the survival rates were 96.8% in the maxilla and 98.5% in the mandible. The survival rates were 97.6% in the posterior regions and 100% in the anterior regions. 3. The mean bone loss for the first year after prosthesis placement and the mean annual bone loss after the first year for men were significantly higher than that of women (P<0.05). 4. The group of partial edentulism with no posterior teeth distal to the implant prosthesis showed significantly more bone loss compared to the group of partial edentulism with presence of posterior teeth distal to the implant prosthesis in terms of mean bone loss for the first year and after the first year (P<0.05). 5. The mean annual bone loss after the first year was more pronounced in posterior regions compared to anterior regions (P<0.05). 6. No significant difference in marginal bone loss was found in the following factors: jaws, type of prostheses, type of opposing dentition, and submerged /non-submerged implants (P<0.05). Conclusion: On the basis of these results, the factors influencing marginal bone loss were gender, type of edentulism, and location in the arch, while the factors such as arch, type of prostheses, type of opposing dentition, submerged / non- submerged implants had no significant effect on bone loss. In the present study, the cumulative survival rate of the $Neoplan^{(R)}$ implant with a sandblasted and acid-etched surface was 97.9% up to a maximum 57-month period. Further long-term investigations for this type of implant system and evaluation of other various domestic implant systems are needed in future studies.