• Title/Summary/Keyword: 상승 온도

Search Result 3,057, Processing Time 0.03 seconds

The performance of combined heat and power plant according to gas turbine air mass flow rate change (가스터빈 공기량 조절에 따른 열병합발전 성능 변화)

  • Kim, Jae-Hoon;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.18 no.2
    • /
    • pp.32-40
    • /
    • 2022
  • In this study, we investigated the operation data of combined heat and power in accordance with the change of the inlet guide vane with partial load. The partial load 80% could close the inlet guide vane up to 24%, and the exhaust gas temperature could be increased by 52℃. The partial load 90% could close the inlet guide vane up to 12%, and the exhaust gas temperature could be increased by 23℃. At 80% of partial load with the thermal load tracking mode, the output could be increased up to 5.68 MW, the combined cycle efficiency increased by 0.73%, and the combined heat and power efficiency increased by 1.81%. At 90% of the partial load, the output could be increased up to 2.55 MW, the combined cycle efficiency increased by 0.32%, and the combined heat and power efficiency increased by 0.72%.

  • PDF

Study on the Correlation between the Change in SAR and Temperature of the Human Head by use Dental Implant on 3.0T Brain MRI : Using the XFDTD program (3.0T Brain MRI 검사 시 치아임플란트 시술 유무와 인체의 SAR, 체온 변화와의 상관관계에 관한 연구 : XFDTD 프로그램을 이용)

  • Choe, Dea-yeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.139-146
    • /
    • 2017
  • At the Brain MRI examination, RF Pulse are irradiated on the human head in order to acquire MR images. At this time, a considerable part of the irradiated RF Pulse energy is absorbed in our body and the temperature of the human head will rise depending on the degree of exposure, so it will affect the human head. Even if the same RF Pulse energy is given, if the metal is inserted in the human head, the conductivity of the human head is greatly increased by the metal, so the SAR value increases and the temperature also rises. Therefore, we started this research with the question as to whether there is difference between the change in SAR value and temperature displayed on the head of the human according to use or not of the dental implant. Experiments were using the XFDTD program on a 128 MHz RF Pulse frequency by a 3.0 tesla MRI. We can see that both are increasing that the average value of SAR and temperature that absorbed by the human head model used the dental implant. In addition, the average maximum SAR value and the maximum temperature rise in the brain part are shown below the international safety standard value but the influence can not be ignored because of the result may change according to the increase in the number of dental implant. And as future tasks. we need to the simulation of temperature rise and SAR due to an increase in the number of implants and volumes of teeth, dental implant material.

The Characteristics of TPH Removals by Microwave Radiation for Diesel Contaminated Soil (디젤오염토양 마이크로파 처리 시 TPH의 제거 특성)

  • Jeong, Seung-Woo;Lee, Tae-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.11
    • /
    • pp.776-780
    • /
    • 2013
  • TPH degrdation patterns in diesel contaminated soil was investigated with microwave radiation. When microwave radiation on the soil was applied, temperature increment of the aridic soil was quite low, but temperature in the moist soil was dramatically increased even if short period of running time. Up to 20% of the moisture content, the higher moisture content has more increment of temperature, whereas over 20% of the moisture content, temperature in the soil was rather decreased. when 100~700 W power of microwave radiation was applied into the contaminated soil, a lot of TPH removals was observed under 300 W, but negligible increment of TPH removal was detected over 300 W. 60% of TPH removal was achieved with initial 20% moisture content and microwave radiation. Additional 25% removal was accomplished when moisture content was kept constant during radiation period. It indicated that maintaining of constant moisture is an important factor for TPH removal with microwave radiation because moisture and temperature in the soil are decreased with reaction time.

Changes in Solid Elution Rate and Benzo[${\alpha}$]pyrene During Puffing Temperature of Herbal Tea Containing Angelica gigas, Paeoniae radix, Cnidium officinale, Saururus chinensis, Artemisia capillarisin and Zizyphus vulgaris (당귀, 작약, 천궁, 삼백초, 인진쑥 및 산조인을 첨가한 한방차의 팽화 온도별 고형분 용출율과 Benzo[${\alpha}$]pyrene의 변화)

  • Jang, Jae-Seon;Choi, Mi-Yong;Oh, Sung-Cheon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.305-312
    • /
    • 2014
  • The following study is the result of herbal teas puffed at different temperatures between $140{\sim}220^{\circ}C$. There was change of single breadth that some carbonization occurs according to rise of processing temperature and crude ash content rises relatively, and crude protein and crude fat content had hardly changed and moisture content decreased. The solid elution rate of the herbal teas appeared by 0.18~0.27% (w/w), it increased as puffing temperature rises. The reason for the increase in solid elution rates is due to the breakage of cross bridges between the raw materials in the herbal tea which are carbohydrates, proteins, lipids and etc. after treatments of physical changes rather than chemical ones. Benzopyrene content happened difference in B(${\alpha}$)P content according to processing temperature, raw material by 0.18~0.24 ppbs.

A Study on Temperature and Retaining Ion Effect on the Separation of Lanthanides (란탄계열원소들의 양이온교환분리에서의 온도와 보유이온의 영향에 관한 연구)

  • Young-Gu Ha;Bong-Il Ji
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.6
    • /
    • pp.601-606
    • /
    • 1989
  • The effects of temperature and retaining ion on the separation factor (${\alpha}$) and distribution ratio (D) of some lanthanides ($Pr^{3+},\;Nd^{3+},\;Sm^{3+},\;and\;Er^{3+}$) have been studied in the EDTA solution as an elutant by using Amberite IR 120 + resin. The retaining ions on the resin were ${NH_4}^+,\;Na^+,\;K^+,\;Mg^{2+},\;Ca^{2+},\;Zn^{2+}$and $Ce^{3+}$. Separation factor of Nd/Pr is much improved by using $Ce^{3+}$ as retaining ion. The distribution ratios were decreased with the increase of temperature, but separation factors did not always increase with the increase of temperature. However, in the case of $Ce^{3+}$ as retaining ion, separation factors of Nd/Pr and Sm/Nd were increased with the increasing of temperature. And also in the case of $Zn^{2+}$ as retaining ion, separation factor of Er/Sm was increased with the increasing of temperature.

  • PDF

Study on Solar Air Collector with Perforated Endothermic Panel(Experimental and Numerical Study) (흡열다공판을 이용한 공기식 태양열 집열 유닛에 관한 연구(실험 및 수치해석적 연구))

  • Kim, Myoung-Jun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.732-739
    • /
    • 2011
  • In recent years, the crisis of energy is growing seriously and also the contamination of ecology has been reverberated as international problem. The social concerns on energy crisis have been growing for the last several years and also the interests in new and renewable energy have been increased. Therefore, in order to solving these problems, this study has dealt with the solar air collector with perforated endothermic panel to increase the indoor temperature. And also, the PV panel for running indoor air circulating fan has used to increase the convective heat transfer. This study is consisted with experiment and numerical parts. From this study, the experimently result is indicated that the inlet air temperature is increased up to 45[$^{\circ}C$]. This temperature is enough to heat the indoor air during winter season. And the numerical calculation results revealed that the mixing effect of convection is increased with increasing in fan circulating power.

Control of Thermal Cracking by Pipe-Cooling System in Double T-Beam Bridge (파이프쿨링에 의한 Double T-beam 교량의 온도균열제어에 관한 연구)

  • 정철헌;홍민기;전세진;박세진
    • Magazine of the Korea Concrete Institute
    • /
    • v.14 no.1
    • /
    • pp.53-60
    • /
    • 2002
  • 매스 콘크리트 구조물에서는 콘크리트 타설 후 시멘트의 수화열로 인한 온도응력에 의해서 온도균열의 발생 가능성이 매우 높다. 따라서, 매스 콘크리트 시공시, 온도균열을 구조물의 내구성 관점에서 최대한 억제시킬 필요가 있다. 최근에는 국내에서도 단위시멘트량이 많은 배합을 이용하는 고강도 콘크리트 구조물의 시공이 증가되고 있다. 이와 같은 매스 콘크리트 구조물은 단위시멘트량이 많기 때문에 부재내 수화열에 의한 온도의 상승 속도가 빠르기 때문에 시공에 앞서 사전에 설계, 재료 및 시공 측면에서 온도균열 제어 대책을 검토할 필요가 있다.(중략)

Effect of conductor temperature rise generated by load current on the cable life (운전전류에 의한 도체온도 상승이 케이블 수명에 미치는 영향)

  • Yun, Jea-Hun;Lim, Seong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1445-1447
    • /
    • 2003
  • 산업공장에서 저압케이블이 지중에 집중 매설되어 있는 경우 운전전류에 의한 케이블 도체온도가 도체허용온도를 초과할 수 있다. 또한 절연재질의 활성화 에너지와 환경온도로 표현되는 아레니우스 모델의 환경온도 대신 운전전류에 의해 계산된 도체온도를 사용하여 케이블의 수명을 예측하여 보았다.

  • PDF

Study of spatial temperature distribution during combustion process in a high temperature and pressure constant volume chamber (고온 고압 정적 연소실에서 연소과정에 따른 온도 분포 측정)

  • Kim, Ki-hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.345-350
    • /
    • 2017
  • Downsizing is widely applied to diesel engines in order to improve fuel efficiency and reduce exhaust emissions. Engine sizes are becoming smaller but pressure and temperature inside combustion chambers are increasing. Therefore, research for fuel spray under high pressure and temperature conditions is important. A constant volume chamber which simulates high temperature and pressure likely to be found in diesel engines was developed in this study. Pressure and temperature were increased abruptly because of ignition of the pre-mixture in the constant volume chamber. Then pressure and temperature were gradually decreased due to the heat loss through the chamber wall. Fuel spray occurred when temperature and pressure were reached at the target condition. In this experiment, the temperature condition should be exactly defined to understand the relation between fuel evaporation and ambient temperature. A fast response thermocouple was developed and used to measure the temporal and spatial temperature distribution during the combustion process inside the combustion chamber. In the results, the core temperature was slightly higher than the bulk temperature calculated by the gas equation. Ed-note: do you want to say 'ideal gas equation'? This was attributed to the heat transfer loss through the chamber wall. The vertical temperature deviation was higher than the horizontal temperature deviation by 5% which resulted from the buoyancy effect.

Effect on the Temperature in Forest Dominant Vegetation Change (산림 우점식생 변화가 온도에 미치는 영향)

  • An, Mi-Yeon;Hong, Suk-Hwan
    • Korean Journal of Environment and Ecology
    • /
    • v.32 no.1
    • /
    • pp.97-104
    • /
    • 2018
  • This study investigated the effect of forest type changes in Daegu, the hottest city in Korea, on the land surface temperature (LST). The LST change by forest type was analyzed by 2scene of Landsat TM image from 1990 to 2007. The land cover types were classified into 4 types; forest areas, urban areas, cultivated areas and other areas, and water areas. The forest areas were further classified into the coniferous tree areas and the broadleaf tree areas. The result of the statistical analysis of the LST change according to the forest type showed that the LST increased when the forest was changed to the urban area. The LST increased by about $0.6^{\circ}C$ when a broadleaf tree area was changed to an urban area and about $0.2^{\circ}C$ when a coniferous tree area was changed to an urban area. This was the temperature change as the result of the simple type change for 17 years. The temperature change was larger when considering both cases of the forest type being retained and changed. The LST increased by $2.3^{\circ}C$ more when the broadleaf tree areas were changed to the urban areas than when broadleaf trees were maintained. The LST increased by $1.9^{\circ}C$ more when the coniferous tree areas were changed to the urban areas than when the coniferous tree areas were maintained. The LST increased by $0.4^{\circ}C$ more when the broadleaf tree areas were destroyed than when the coniferous tree areas were destroyed. The results confirmed that the protection of broadleaf trees in urban forests was more effective for mitigating climate change.