• Title/Summary/Keyword: 상수도시설물

Search Result 67, Processing Time 0.033 seconds

A Study on Macroscopic Future maintenance Investment Scale for National SOC Infrastructure (국가 사회기반시설물에 대한 거시적 관점의 미래 유지보수 투자규모에 관한 연구)

  • Lee, Dong-Hyun;Jun, Tae-Hyun;Kim, Ji-Won;Park, Ki-Tae;Kim, Yongsoo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.87-96
    • /
    • 2017
  • It is important to estimate the future maintenance budget of all SOC infrastructure at the national strategic level. In this study, Based on a currently available statistics data, we predicted future maintenance investment for all SOC infrastructure in Korea. We have studied the applicable prediction models, and we developed the prediction models that can calculated the future maintenance cost by a real expenditure date. The subjects of facilities are bridges, tunnels, pavements, harbors, dams, airports, water supply, rivers and port. As a result of total estimated cost, eight types of SOC infrastructures are about 23 trillion won for the next 10years, and the most expensive facilities are road pavements and bridges.

A study on the Improvement of Cost Structure by Remote Inspection for Water Supply System based on GIS (GIS 기반의 상수도 원격검침에 의한 비용구조개선에 관한 연구)

  • 김주일;연상호
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2003.11a
    • /
    • pp.402-406
    • /
    • 2003
  • 우리나라의 물의 공급을 위한 수도역사가 1백년을 넘어서고 있는데 반해 전체 물 생산량은60%에서 70% 초반에 머물고 있는 실정이다. 1999년 기준 1일 평균생산 한 물 432만 7천톤에서 요금 부과한 물의 양은 조5만 1천톤으로 137만 6천톤이 유실되어 증발한 것이다. 이를 금액으로 환산하면 천문학적인 젓으로 유수율이 현저히 낮은 것이다. 이렇게 유수율이 현저히 떨어지는 요인에는 시설물 관리의 어려움과 자원 및 세수관리의 어려움으로 나누어 볼수 있는데, 본 연구에서는 상기의 문제점들을 해소하기 위한 방안의 하나로 무선통신 기술을 이용한 효율적인 시설물 관리 및 원격검침 방안을 제시함으로써 유수율 제고 및 누수율 감소를 위한 대책을 제시함으로서 기존의 방법에 비해 매시간 자동 검침을 함으로써 효율적 검침 가능은 물론 소요비용을 비교하여 GIS 기반의 원격검침방안을 제시하였다.

  • PDF

A Study on the Improvement for Water Supply Meter Inspection using Wireless Technology at Cheungjoo City (Wireless Technology를 활용한 상수도 검침 개선에 관한 연구)

  • 김주일;연상호
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2003.05a
    • /
    • pp.260-267
    • /
    • 2003
  • 우리나라의 물의 공급을 위한 수도역사가 1백년을 넘어서고 있는데 반해 전체 물 생산량은 60%에서 70% 초반에 머물고 있는 실정이다. 99년 기준 1일 평균생산 f한 물 432만 7천톤에서 요금 부과한 물의 양은 295만 1천톤으로 137만 6천톤이 증발한 것이다. 이를 금액으로 환산하면 천문학적인 것으로 다른 표현으로 유수율이 현저히 낮은 것이다. 이렇게 유수율이 현저히 떨어지는 요인에는 시설물 관리의 어려움과 자원 및 세수관리의 어려움으로 나누어 볼 수 있는데, 본 연구에서는 상기의 문제점들을 해소하기 위한 방안의 하나로 무선통신 기술을 이용한 효율적인 시설물 관리 및 검침 방안을 제시함으로써 유수율 제고 및 누수율 감소를 위한 대책을 제시함으로서 무선검침시스템의 안정성과 계측의 정확성 및 신뢰성에 대한 검증을 위해 충북 청주시 상당구 우암동 일부 지역을 선정하여 1시간 마다 자동 검침을 통해 효율적 검침 가능 여부와 설치 대비 경제성 등을 알아보기 위해서 실시하였다.

  • PDF

Improvement of Physical Condition Assessment in Water Mains (상수도 관로의 물리적 상태평가 기준 개선)

  • Kim, Ju-Hwan;Lee, Doo-Jin;Bae, Cheol-Ho;Ahn, Hyo-Won;Hwang, Jin-Soo;Choi, Doo-Yong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1710-1715
    • /
    • 2010
  • Service life of water pipes buried in the underground is considerably affected from various factors such as environmental characteristics, pipe characteristics, operation and maintenance, etc. Therefore it is difficult to determine their service life as uniformly the same value assigned by related laws and ordinances. As a result, the service life should be determined by the technical judgement based on the assessment for the condition of water pipes. In this study, It was established that the methodology could predict present and future failure risk, and plan short and long-term strategies for replacement/rehabilitation through the assessment for the physical deterioration and economical values of buried water pipe. The methodology was applied for the verification and reliability to several sites selected in multi-regional transmission pipelines. The proposed method could helps to support reasonable and economical decision of rehabilitation/replacement in the present and future. To improve conventional assessment method of aged water pipes, affecting factors are simplified based on the statistical analysis results from the measured data in the field and the physical deterioration mechanism for better reliability. Also, the guide-line is developed to carry out the reasonal rehabilitation planning through water pipe condition assessment.

  • PDF

Development of leakage detection model in water distribution networks applying LSTM-based deep learning algorithm (LSTM 기반 딥러닝 알고리즘을 적용한 상수도시스템 누수인지 모델 개발)

  • Lee, Chan Wook;Yoo, Do Guen
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.8
    • /
    • pp.599-606
    • /
    • 2021
  • Water Distribution Networks, one of the social infrastructures buried underground, has the function of transporting and supplying purified water to customers. In recent years, as measurement capability is improved, a number of studies related to leak recognition and detection by applying a deep learning technique based on flow rate data have been conducted. In this study, a cognitive model for leak occurrence was developed using an LSTM-based deep learning algorithm that has not been applied to the waterworks field until now. The model was verified based on the assumed data, and it was found that all cases of leaks of 2% or more can be recognized. In the future, based on the proposed model, it is believed that more precise results can be derived in the prediction of flow data.

Smart Manhole Device for Underground Facility Management (지중 시설물 관리를 위한 스마트 맨홀 디바이스)

  • Kim, Jong-Duk;Han, Seung-Heon;Kim, Yong-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.8
    • /
    • pp.996-1003
    • /
    • 2019
  • The undergrounding of diverse ground facilities has led to a decrease in issues, such as foul smell of water supply systems and wastewater, a fall of telephone poles, electromagnetic waves and breaking of wires caused by a railway work. On the other hand, there are new issues, including a fall accident, explosion affected by flammable gas, a choking accident by harmful gas and a lack of oxygen concentration, a fire coming from high-tension wire heating and flooding in the manhole. Besides, these issues damage the civil society and are an anxiety to public safety. Therefore, this paper is focused on a smart manhole device for stable communication environments inside and outside the manhole and wireless communication with various devices for managing facilities in the manhole, and aims to make a contribution to public safety by suggesting a direction of future underground facility management.

In-depth investigation and improvement of cathodic protection system for water pipelines (상수도관로 전기방식 시스템의 진단 및 개선 사례)

  • Han, Chang-Dong;Lee, Seung-Yong;Jang, Jeong-Ho;Lee, Sang-Gun;Choi, Jun;Kim, Tea-Ho;Jung, Sung-Won;Li, Seon-Yeob
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2015_2016
    • /
    • 2009
  • 전기방식이 실시되고 있는 상수도 관로는 관의 노후화, 코팅의 열화, 부적절한 방식시스템의 적용 및 타 시설물과의 간섭 등으로 부분적으로 방식전위 미달구간이 존재한다. 이러한 방식전위 미달구간에 대하여 토양환경 측정 및 방식소요전류량 산정, 간섭 시험 등을 통하여 토양환경은 부식이 '발생하는 구간' 및 '미약하게 발생'하는 구간으로 나타났다. 임시 가통전 시험을 통하여 방식소요전류량을 구할 수 있었다. 간섭영향 시험으로 간섭 여부 및 전식 발생지점을 추정할 수 있다. 현장 측정 결과와 설계기준을 바탕으로 적절한 전기방식 보강 계획을 수립하여 현장에 부분적으로 설치하였으며 방식상태를 분석하였다. 단순히 설계된 소요전류량만을 증가시키는 방안보다 부분적인 방식보강 및 주변 배관 상태를 고려하여 적절한 통합 방식방안을 적용하는 것이 더 효율적인 것으로 나타났다.

  • PDF

A Study on Geo-Spatial Information System Database Establishment for Urban Information Analysis -With Emphasis on Water Supply Facilities- (都市情報解析을 위한 地形空間情報體系의 資料基盤部 構築에 關한 硏究 -上水道 施設物管理 中心으로-)

  • Yeu, Bock-Mo;Youn, Kyung-Chul;Choi, Chul-Soon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.10 no.2
    • /
    • pp.31-36
    • /
    • 1992
  • Geo-Spatial Information Systems(GSIS) are being used in various urban municipalities as a tool in decision making. Efforts are being made to implement geo-spatial information system databases to systematically and effectively carry out planning, management and monitoring in various fields. This study is about the database establishment of geo-spatial information systems. The study was then applied to water supply facilities management, where the functions and data used in water management were identified through system analysis and the geo-spatial database was designed based on this analysis. Also four application programs were developed to support departments which used various maps and drawings.

  • PDF

Defining Flushing Path and Priority for Flushing Operation (플러싱공법을 위한 세척구역 및 순서 결정방안)

  • Gim, A Rin;Jo, Yeong Bin;Ha, Jeong Tae;Kim, Jin Hyeok;Jun, Hwan Don
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.239-239
    • /
    • 2020
  • 상수관망은 수용가에게 용수를 공급하는 사회기반시설물로, 용수를 공급하는 과정에서 관내에 이물질, 스케일 등의 생성은 불가피하다. 관로 변경, 단수로 인한 비상시 용수 공급 등의 유향 및 유속이 변화가 발생할 경우 스케일이 박리되어 적수사고 등의 수질문제가 발생 할 수 있으며, 이에 사전에 스케일을 제거 할 필요성이 있다. 스케일을 제거하기 위해서는 주기적인 관세척이 필요하며, 대표적인 공법으로는 플러싱공법이 있다. 현재까지 플러싱공법에 대한 연구는 실험을 통한 적용 권장 기준으로 진행되어 왔으나, 실제 상수관망에서 적용권장 기준을 확보하기 위한 방안에 대한 연구는 미흡한 실정이다. 플러싱공법의 대표적은 종류는 재래식 플러싱공법과 단방향 플러싱공법이 있다. 재래식 플러싱공법은 제수밸브를 조작하지 않는 방법으로, 모든 소화전에서 용수를 방출하는 공법이다. 단방향 플러싱공법은 제수밸브를 조작하여, 일정한 방향으로 요수를 방출하는 공법이다. 단방향 플러싱공법은 재래식 플러싱공법보다 유속확보 측면에서 유리하여 관로 세척을 위한 유량 및 유속 확보가 용이하다. 단방향 플러싱공법을 적용하기 위해서는 관로의 유속을 확보하기 위해 세척구역 정의하는 것이 필요하다. 이에 본 연구에서는 세척구역 정의를 통한 플러싱공법 적용 방안을 제안하고자 한다. 세척구역은 크게 3단계로 구분한다. 먼저 블록단위의 세척순서를 결정하고, 블록 내 관망 세척구역을 결정한다. 이때 관로의 관경, 곡선구간, 세척구역의 길이를 고려하여 세척구역을 정의한다. 마지막으로 결정된 세척구역을 제수밸브의 위치, 조작 횟수에 근거하여 세척순서를 결정한다. 본 연구를 통해 실제 상수관망 플러싱공법 적용 절차 수립에 기여할 수 있다.

  • PDF

A Study on Vulnerability Assessment for Field Drought Using TOPSIS (TOPSIS를 이용한 밭 가뭄에 대한 관정 취약성 평가 연구)

  • Shin, Hyung Jin;Lee, Gyu Min;Lee, Jae Nam;Park, Chan gi;Lee, Gyusang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.346-346
    • /
    • 2021
  • 본 연구는 농업지역의 가뭄 발생에 대하여 활용되는 관정의 효율적 관리를 목표로 우선관리가 필요한 취약지역을 선정하는 방안을 수립하였다. 특히 한국에서는 논 위주의 농업 생산기반정비가 진행되어 왔으나 최근 경제성장과 소득증대에 따른 농산물 소비 구조의 변화로 다양한 밭 작물경작이 증가하여 밭 관개시설물에 대한 정비가 요구되고 있다. 따라서 가뭄 대응을 위한 밭작물의 용수공급 시설물인 관정에 대한 취약성 평가를 통하여 관리의 목표와 우선관리 지역의 선정이 필요하다. 가뭄에 대한 관정 취약성 평가는 최근 널리 사용되는 다기준의사결정 기법인 TOPSIS를 적용하였으며, 한국 전역 158개의 시, 군을 평가대상으로 한다. 평가 인자는 관정능력 및 효율에 긍정적 영향을 주는 강수량, 지하수위, 관정 당 양수량과 부정적 영향을 주는 경지면적, 연속무강우일수, 민간관정 비율을 선정하였다. 평가결과로부터 관정 당 양수량과 상수도 보급율이 관정 효율 취약성 평가를 통한 우선 관리 순위선정에 주요한 영향을 주는 것으로 분석되었다.

  • PDF