• Title/Summary/Keyword: 상수도공급 시스템

Search Result 77, Processing Time 0.03 seconds

Development of Ubiquitous Telemetry Water Reading System Using RF and CDMA (RF와 CDMA를 활용한 상수도 원격검침시스템 개발)

  • Lho, Tae-Jung;Kim, Hwa-Il;Lee, Wook-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.2
    • /
    • pp.215-221
    • /
    • 2009
  • In recent, there has been progressed in various ways of research and development about a ubiquitous telemetry reading, but several problems are arising the reliability of reading value, power supply and so on. These issues were solved by using the RF module and digital pulse meter with photocoupler. Realized by this study, a telemetry reading system, utilizing RF and CDMA telecommunication, and check in real time the state of water leakage by managing the distinct usage data. In addition, the users can check it in person, and it can minimize the public enmities. Further, as a part of the silver industry fur constantly growing senior population, it might be introduced as safety supervision system.

A Study on the Estimation of the GHGs Emissions to the Reuse of De-ionized Water Production Process in Semiconductor Factory (반도체 생산용 초순수 제조공정의 농축수 재이용에 따른 온실가스 발생량 평가에 관한 연구)

  • Han, Jong-Min;Chung, Jin-Do;Kim, San
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.518-525
    • /
    • 2018
  • In the 21st century, human beings are becoming increasingly concerned about greenhouse gas emissions as the environment changes due to climate change become serious. The temperature of Korea has risen by approximately $1.5^{\circ}C$ from 1904 to 2000, and the climate is changing gradually to a subtropical climate. As a result, the frequency of floods and droughts increases, so that the water available to humans is decreasing every year, and the cost of using city water is rising every year. The reuse of wastewater that is normally abandoned is inevitable. This study examined the monthly data for 6 months of operation by installing a reuse system of concentrated wastewater (Re R/O System) that is generated during the process of manufacturing de-ionized water (DI-Water System) used in semiconductor processing. As a result of the survey, the city water supply saved approximately $2,767m^3$ per month. The average annual greenhouse gas emissions was $1,329.07kg-CO_2$ per month due to the electricity consumption of the water reuse system. On the other hand, because of the reduction in city water supply, the average monthly average of $918.64kg-CO_2$ was reduced, and the greenhouse gas emissions were increased to $410.43kg-CO_2$ per month. If it improves some processes in the water reuse system, the amount of greenhouse gas emissions can be reduced by an average of $254.41kg-CO_2$ per month.

A Study on the Improvement for Water Supply Meter Inspection using Wireless Technology at Cheungjoo City (Wireless Technology를 활용한 상수도 검침 개선에 관한 연구)

  • 김주일;연상호
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2003.05a
    • /
    • pp.260-267
    • /
    • 2003
  • 우리나라의 물의 공급을 위한 수도역사가 1백년을 넘어서고 있는데 반해 전체 물 생산량은 60%에서 70% 초반에 머물고 있는 실정이다. 99년 기준 1일 평균생산 f한 물 432만 7천톤에서 요금 부과한 물의 양은 295만 1천톤으로 137만 6천톤이 증발한 것이다. 이를 금액으로 환산하면 천문학적인 것으로 다른 표현으로 유수율이 현저히 낮은 것이다. 이렇게 유수율이 현저히 떨어지는 요인에는 시설물 관리의 어려움과 자원 및 세수관리의 어려움으로 나누어 볼 수 있는데, 본 연구에서는 상기의 문제점들을 해소하기 위한 방안의 하나로 무선통신 기술을 이용한 효율적인 시설물 관리 및 검침 방안을 제시함으로써 유수율 제고 및 누수율 감소를 위한 대책을 제시함으로서 무선검침시스템의 안정성과 계측의 정확성 및 신뢰성에 대한 검증을 위해 충북 청주시 상당구 우암동 일부 지역을 선정하여 1시간 마다 자동 검침을 통해 효율적 검침 가능 여부와 설치 대비 경제성 등을 알아보기 위해서 실시하였다.

  • PDF

Review of Water Rights Related Acts (국내 수리권 관련 법률 고찰)

  • Kim, Tae Jin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.262-262
    • /
    • 2021
  • 수리권이란 한정된 수자원을 개인, 지자체 및 국가 등이 법률적 근거에 따라 독점적 및 균형적으로 사용할 수 있는 권리를 의미한다. 법률적인 관점에서 수리권은 「하천법」에 근거하여 기존의 물 사용자의 취수권을 우선 인정해 주는 관행수리권과 허가절차에 따라 취수를 허용하는 권리를 획득하는 허가수리권으로 구분할 수 있다. 또한, 「댐 건설 및 주변지역지원 등에 관한 법률(댐 건설법)」에 근거하여 댐 건설 이전의 관행수리권과 댐 건설 이후의 기득수리권으로 구분할 수 있다. 본 연구에서는 수원, 상수도 및 하수도 등 물 공급/처리에 대한 국내 수리권 법률을 검토하였다. 향후 검토된 수리권 관련 법률은 수리권에 기초를 둔 하천/저수지 모델의 국내 적용에 필요한 법률적 근거로 활용될 것이다.

  • PDF

Leakage Reduction through Establishment of Block System in Jeju City (제주시 상수도 관망 블록시스템 구축을 통한 누수 저감)

  • Cha, Joonho;Kim, Jinkeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.5
    • /
    • pp.693-703
    • /
    • 2012
  • Leakage in water supply system can cause water resources loss in addition to the water quality degradation. In this research, leakage reduction after establishment of a block system in the area with leakage rate of 69.0 % was investigated using EPANET simulation. The average water pressure for the research area was $5.17kgf/cm^2$ which was relatively high, and several sites were deviated from recommended water pressure ranges(i.e., 1.5 ~ $7.1kgf/cm^2$). However, the average water pressure in the area was reduced to 3.81 and $3.49kgf/cm^2$ after the introduction of block system with a water pressure relief valve(PRV) setting of 3.0 and $2.5kgf/cm^2$, respectively. Under the installation of a PRV with regulating pressure of $2.5kgf/cm^2$, the predicted leakage was reduced from $4,420.3m^3/d$ to $3,028.1m^3/d$, which was equivalent to the leakage reduction from 31.0 % to 23.5 %.

Study on the Remote Control Power Management System of an Unmanned Stations (무인사업장의 원격제어 전원관리시스템 고찰)

  • Kim, Kwang-Soo;Lee, Gyeong-Bae;Choi, Jang-Geon;Lee, Kyung-Woo;Byun, Doo-Gyoon
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1317-1318
    • /
    • 2015
  • 최근 ICT 기술의 발전으로 원거리에 위치한 광역 상수도의 취수장, 가압장, 감압변실 및 배수지 등의 시설물은 중앙제어실에서 효율적인 설비운영을 위해 원격통합관리로 감시제어를 수행하여 생산성을 제고하고 있다. 단위사업장에 낙뢰 유입으로 인한 순간정전이나 오동작 등의 영향에 의한 누전차단기 트립 증상이나 제어계측설비의 시스템 다운현상이 발생할 경우에 전원설비나 계측제어설비를 복구하기 위해서는 운영자가 사업장 현장에 출동하여 설비를 복구해야만 한다. 출동에 따른 많은 시간과 비용이 발생할 뿐만 아니라 응급조치가 미흡할 경우에는 수돗물 공급 중단 등의 위험성이 발생할 소지가 있다. 본 논문에서는 단위사업장의 서지유입이나 설비 오동작 등의 원인으로 무인사업장 설비에 System down 현상이 발생하면 단위사업장에 출동하지 않고 원격의 중앙제어실에서 원격 명령 또는 자동 프로그램에 의한 전원 Reset 동작으로 현장 제어설비가 원활하게 동작함으로써 무인사업장의 효율적인 운영관리가 가능한 원격제어 전원관리시스템 구축사례를 제시하고자 한다.

  • PDF

An application of the A-PDA model and the water supply performance index for the temporal and spatial evaluation of the performance of emergency water supply plans via interconnections (비상시 용수 연계공급 성능의 시·공간적 평가를 위한 A-PDA 모형 및 공급성능지표의 적용)

  • Oak, SueYeun;Kim, SuRi;Jun, Hwandon
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.11
    • /
    • pp.977-987
    • /
    • 2018
  • The purpose of the water distribution system is gradually changing to increase the flexibility for responding to various abnormal situations. In addition, it is essential to improve resilience through preparing emergency plans against water supply failure. The most efficient way is emergency interconnections which supply water from interconnected adjacent blocks. To operate successful interconnections, it is essential to evaluate the supply performance in spatial and temporal aspects. The spatial and temporal aspects are dominated by its interconnected pipes and interconnected reservoirs respectively. In this study, an emergency interconnection scenario where problem occurred in reservoir 1 at 0:00hr in A city, Korea. An Advanced-Pressure Driven Analysis model was used to simulate the volume and inflow volume of the interconnected reservoirs. Based on the hydraulic analysis results, a multi-dimensional evaluation of the supply performance was conducted by applying possible water supply range indicator (PWSRI) and possible water supply temporal indicator (PWSTI) which are based on fuzzy membership functions. As a result, it was possible to evaluate the supply performance on the sides of consumers in spatio-temporal aspects and to review whether established plans mitigate the damage as intended. It is expected to be used for decision making on structural and non-structural emergency plan to improve the performance of an emergency interconnection.

The Proposal of Performance Evaluation Techniques for Demo Plant System of SWG (SWG Demo Plant 시스템에 대한 성능평가 기법 제시)

  • Chae, Soo Kwon;Choo, Tai Ho;Yoon, Hyeon Cheol;Yun, Gwan Seon;Kwon, Yong Been
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.215-215
    • /
    • 2015
  • SWG(Smart Water Grid)는 한정적인 수자원을 효율적으로 이용하고 사용자 입맛에 맞춰 물을 안정적으로 공급하고자 하는 양방향 개념으로 수자원 분야에서 각광받는 실정이다. SWG의 성능을 평가하는 연구사례는 많지 않으며 현재 국내의 경우 실증단지를 구축하고 있는 단계이다. 그러므로 성능평가를 수행하기 위한 실측자료가 부재하므로 성능평가 지표선정에 활용 할 수 있는 자료가 제한적이다. 따라서 미국의 Leed, 영국의 BREEAM, 일본의 CASBEE, 호주의 Green Star의 인증 기준에서 수자원에 대한 항목과 기존의 IWA, World Bank, AWWA, JWWA, OFWAT 같은 해외 상수도 수행능 지표와 상수도 및 정수장 기술진단에서 제시하는 기준을 바탕으로 성능평가지표를 선정 보완하여 Water Facility Index, Smart Index, Optimum System Index로 분류하여 각 세부의 성능평가지표를 선정하였다. 선정된 지표는 AHP기법를 활용하여 1-4단계에 걸쳐 계층화를 실시하고 Bottom-up방식으로 4단계에서부터 1단계로 평가를 진행하도록 구성했다. 4단계에서는 계층 별 쌍대비교 결과를 바탕으로 중요도에 따른 가중치를 부여하고 차등 점수를 적용하며, 이는 3단계에서 필수적으로 만족해야하는 지표들을 설정하고 평가하기 위해 사용된다. 3단계에서는 지표평가 후 "보통" 이상의 점수를 획득해야 2단계로 진행할 수 있고, 2단계에서는 3가지 큰 지표를 설정 후 총점 기준 60%이상의 최소득점 기준을 만족해야 1단계로 진행할 수 있도록 구성했다. 이러한 절차를 바탕으로 마지막 1단계에서는 100점을 만점으로 하는 6단계의 최종성능을 평가하는 결과를 제시할 수 있다. 본 연구에서는 국외 성능평가 사례 중 SWG와 관련된 지표를 구성하여 성능평가를 수행할 수 있는 기법을 제안하였다. 향후 지속적인 연구 진행 결과와 실측자료를 수집하여 수정 및 보완이 수행될 예정이다.

  • PDF

Development of a quantification method for modelling the energy budget of water distribution system (상수관망 에너지 모의를 위한 정량화 분석기법 개발)

  • Choi, Doo Yong;Kim, Sanghyun;Kim, Kyoung-Pilc
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.spc1
    • /
    • pp.1223-1234
    • /
    • 2022
  • Efforts for reducing greenhouse gas emission coping with climate change have also been performed in the field of water and wastewater works. In particular, the technical development for reducing energy has been applied in operating water distribution system. The reduction of energy in water distribution system can be achieved by reducing structural loss induced by topographic variation and operational loss induced by leakage and friction. However, both analytical and numerical approaches for analyzing energy budget of water distribution system has been challengeable because energy components are affected by the complex interaction of affecting factors. This research drew mathematical equations for 5 types of state (hypothetical, ideal, leak-included ideal, leak-excluded real, and real), which depend on the assumptions of topographic variation, leakage, and friction. Furthermore, the derived equations are schematically illustrated and applied into simple water network. The suggested method makes water utilities quantify, classify, and evaluate the energy of water distribution system.

Determination of representative water quality accident scenarios and appropriate analysis techniques through case study in water distribution networks (상수관망 내 수질사고 사례분석을 통한 대표 수질사고 시나리오 및 적정해석기법 결정)

  • Yoo, Do Guen;Hong, Sungjin;Moon, Gihoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.428-428
    • /
    • 2021
  • 상수관망 내 수질사고는 매우 다양한 원인과 상황에서 시·공간적으로 광범위하게 발생가능하다. 일반적인 수질사고의 정성적 정의는 "정상적인 운영에 비하여 상대적으로 비정상적인 활동이나 행동에 의해 발생되는 수질문제"라고 할 수 있으나, 이는 매우 광의적이라 할 수 있으며 실제 현장에서는 발생 가능한 모든 수질사고 시나리오를 미리 예측하여 대비하기에 한계가 있다. 본 연구에서는 국외 및 국내 지자체, 그리고 K-water 등의 자료를 확보하여, 상수도 공급계통에서 발생한 수질사고 사례 및 발생 빈도 등을 분석하였다. 이를 상수도 관망 내에서 발생빈도가 잦고 피해영향이 큰 대표 수질사고 발생 시나리오 선정에 활용하였다. 과거 사례를 분석한 결과, 관망 내 대표적인 수질사고는 정상적 운영조건 (예, 정수처리문제에 의한 유출수내 고탁도 발생)뿐 만 아니라, 비정상적인 운영조건 (수계전환, 밸브조작 등에 의한 유속, 수압 변동에 의한 고탁도 발생)에서 발생 가능함을 확인하였다. 이와 같은 대표적 수질사고는 수리학적 조건의 변화에 따라 관망 내 수질이 변화되어 발생되므로, 수질사고의 현실적인 모의를 위해서는 합리적인 수리학적 관망해석이 수반되어야 한다. 상수관망 시스템의 수리해석 기법은 크게 수요기반해석(Demand Driven Analysis; DDA)과 수압기반해석(Pressure Driven Analysis; PDA)로 구분 가능하다. 기본적으로 정상적 운영조건은 수요기반해석의 수행이 적절하며, 비정상적 운영조건은 수압저하에 의한 수리적상태가 변동하므로 수압기반해석이 필수적이라 할 수 있다. 본 연구에서는 대표적 수질사고의 모의 시 필요한 적정수리해석 기법을 제안하고, 각 적정 해석기법 별 검·보정이 필요한 인자들에 대해 제시하였다. 이와 같은 수리해석 기법을 적절히 활용할 경우, 관망 내 탁수사고 발생 가능성이 높은 지점 등을 결정하는 방법론의 정확도가 높아질 것으로 기대된다.

  • PDF