• Title/Summary/Keyword: 상수관망 최적설계

Search Result 35, Processing Time 0.025 seconds

Optimal valve installation of water distribution network considering abnormal water supply scenarios (비정상 물공급 시나리오를 고려한 상수도관망 최적 밸브위치 결정)

  • Lee, Seungyub;Jung, Donghwi
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.10
    • /
    • pp.719-728
    • /
    • 2019
  • Valve in water distribution network (WDN), that controls the flow in pipes, is used to isolate a segment (a part of WDN) under abnormal water supply conditions (e.g., pipe breakage, water quality failure event). The segment isolation degrades pressure and water serviceability in neighboring area during the water service outage of the segment. Recent hydraulic and water quality failure events reported encouraging WDN valve installation based on various abnormal water supply scenarios. This study introduces a scenario-based optimal valve installation approach to optimize the number of valves, the amount of undelivered water, and a shortest water supply path indicator (i.e., Hydraulic Geodesic Index). The proposed approach is demonstrated in the valve installation of Pescara network, and the optimal valve sets are obtained under multiple scenarios and compared to the existing valve set. Pressure-driven analysis (PDA) scheme is used for a network hydraulic simulation. The optimal valve set derived from the proposed method has 19 fewer valves than the existing valve set in the network and the amount of undelivered water was also lower for the optimal valve set. Reducing the reservoir head requires a greater number of valves to achieve the similar functionality of the WDN with the optimal valve set of the original reservoir head. This study also compared the results of demand-driven analysis (DDA) and the PDA and confirmed that the latter is required for optimal valve installation.

Development and Application of Reliability Index based on Hydraulic Uniformity in Water Distribution Networks (상수관망의 수리학적 균등성을 이용한 신뢰도 지표의 개발 및 적용)

  • Jeong, Gimoon;Kang, Doosun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.6-6
    • /
    • 2019
  • 상수관망시스템은 공급원으로부터 수요처까지의 용수공급을 위해 구축된 관수로 기반의 사회기반시설물로서, 주로 생활 및 산업 용수를 공급하므로 대규모 사회 경제적 피해를 방지하기 위해서는 안정적인 용수공급 능력이 요구된다. 네트워크의 다양한 특성에 의해 표현되는 상수관망시스템의 신뢰도(reliability)는 크게 시스템 내 구성요소의 안정성(mechanical reliability)과 용수공급의 기능적 안정성(hydraulic reliability)으로 구분할 수 있다. 특히, 시스템의 용수공급 안정성에 주목한 수리학적 신뢰도 연구는 많은 연구자들에 의해 지속적으로 수행된 바 있으며, 다양한 평가방법 및 지표들이 제시되어 활용 중에 있다. 기존의 수리학적 신뢰도 지표들은 주로 수요절점(demand node)에서의 공급가능 수량 및 수압을 바탕으로 산정되었다. 그러나, 절점(node)에서의 공급 상태는 결과에 해당하며, 원인 분석을 위해서는 관로(pipe)의 배치 및 규격을 분석해야 하는 번거로움이 존재한다. 이러한 단점을 보완하기 위해, 본 연구에서는 직접 관로(pipe)의 공급 특성을 분석하여 네트워크의 신뢰도를 평가함으로써, 신뢰도 저하의 원인 분석 및 시스템 개선에 효율적으로 활용할 수 있는 신뢰도 지표를 산정하고자 하였다. 본 연구에서는 상수관로 내 수리학적 기울기가 전반적으로 균등할수록 설계 비용대비 공급 신뢰도, 즉 용수공급 효율이 개선되는 특징을 바탕으로, 네트워크 내 총 에너지 손실로부터 각 관로의 길이, 유량 등의 특성을 고려한 등가 수리경사(Equivalent hydraulic gradient)를 유도하여 모든 관로의 적정 수리경사로 제안하였다. 따라서 각 관로의 실제 수리경사를 대상으로 관로별 수리학적 균등성 지수(pipe hydraulic uniformity index)를 산정하였으며, 더 나아가 전체 시스템의 균등성 지수(system hydraulic uniformity index)를 산정하였다. 제안된 신뢰도 지표는 가상의 네트워크에서 지역 내 용수 사용량이 증가하는 등 용수공급 안정성을 저해하는 몇 가지 시나리오를 바탕으로 검증하였으며, 또한 기존 지표들의 신뢰도 평가 결과와 비교, 분석하였다. 본 연구는 향후 네트워크 최적 설계의 목적함수로 활용하거나, 네트워크의 보강계획 수립에 기여할 것으로 기대된다.

  • PDF

Study on Applying of Unsteady Analysis in ToSS(Total Sewer Operation and Management System) for Optimal Management of Sewer System (하수관망 최적관리를 위한 통합하수관거 시스템의 부정류 해석적용에 대한 연구)

  • Choi, Gye-Woon;Lee, Ho-Sun;Jho, Hyung-Guen
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1148-1153
    • /
    • 2005
  • 하수관거는 국민의 정맥이라고 할 수 있을 정도로 도시의 환경관리와 치수, 쾌적한 환경조성에 있어서 매우 중요한 시설이며 그 규모가 광범위하고 복잡한 네트워크로 구성되어 있다. 이러한 하수관망을 통해 이송되는 물은 지저분하고 냄새가 심하기 때문에 지하에 관의 형태로 대부분 시공되어 왔으며, 상수관망처럼 압력관이 아니라 대부분 중력에 의한 이송방식을 채택하고 있어 문제 발생 시 원인파악과 대처를 힘들게 하는 요인을 가지고 있다. 특히 하수관거의 관리 소홀은 곧바로 토양오염과 인근 환경오염으로 직결되며 장기적으로는 상수를 오염시키는 요인으로 작용하므로 체계적인 방법과 장기적인 안목을 가지고 명확한 분석을 시행할 수 있는 시스템을 가지고 최적으로 유지관리 되어야 한다. 최근 들어 이러한 하수도 시설을 효율적으로 관리 및 개선하기 위해 대도시를 중심으로 근거 조사와 정비 사업이 활발히 시행되고 있다. 그러나, 사업효과를 검증하거나 관로의 유지관리를 위하여 국내 실정에 맞지 않는 외국하수관망 흐름 해석 프로그램을 그대로 사용하고 있고 정확한 해석이 이루어지지 않고 있어 효율적인 유지관리가 어렵다. 이와 같은 문제점을 해결하기 위하여 하수관망해석이나 하수관망 정비시 필요한 불명수산정이 가능하고 국내실정에 맞는 프로그램 개발이 시급한 실정이며, 아울러 프로그램을 효율적 운영하고 관리하는 제어관리 기술을 개발, 진행하고 있다. 본 논문에서는 개발된 프로그램의 부정류 해석 기능을 활용하여 대상구역의 해석을 실시하여 기존분석방법의 I/I결과와 비교하였으며 최적관리를 위한 방안을 제시하였다.준편차가 증가하고 있음을 알 수 있다. 본 연구에서는 상용 CFD모형인 FLOW-3D를 계획 중인 하수처리장의 침전지 유입부 설계에 적용하였으며 저류벽의 위치와 폭, 유공정류벽의 유공율에 따른 유입하수의 분배효과를 분석하였다. 실험을 수행하여 보다 정밀한 공식으로 개선할 수 있었다.$10,924m^3/s$ 및 $10,075m^3/s$로서 실험 I의 $2,757m^3/s$에 비해 통수능이 많이 개선되었음을 알 수 있다.함을 알 수 있다. 상수관로 설계 기준에서는 관로내 수압을 $1.5\~4.0kg/cm^2$으로 나타내고 있는데 $6kg/cm^2$보다 과수압을 나타내는 경우가 $100\%$로 밸브를 개방하였을 때보다 $60\%,\;80\%$ 개방하였을 때가 더 빈번히 발생하고 있으므로 대상지역의 밸브 개폐는 $100\%$ 개방하는 것이 선계기준에 적합한 것으로 나타났다. 밸브 개폐에 따른 수압 변화를 모의한 결과 밸브 개폐도를 적절히 유지하여 필요수량의 확보 및 누수방지대책에 활용할 수 있을 것으로 판단된다.8R(mm)(r^2=0.84)$로 지수적으로 증가하는 경향을 나타내었다. 유거수량은 토성별로 양토를 1.0으로 기준할 때 사양토가 0.86으로 가장 작았고, 식양토 1.09, 식토 1.15로 평가되어 침투수에 비해 토성별 차이가 크게 나타났다. 이는 토성이 세립질일 수록 유거수의 저항이 작기 때문으로 생각된다. 경사에 따라서는

  • PDF

Optimal design methodology of district metered area utilizing Geographic Information System (GIS를 이용한 상수관망 소블록 최적설계기법 개발)

  • Kim, Kyoung-Pil;Park, Yong-Gyun;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.2
    • /
    • pp.223-231
    • /
    • 2015
  • District Metered Area (DMA) construction is one of the most cost effective alternatives for management of water loss (i.e., water leakage) and energy consumption (i.e., water pressure) in water distribution systems. Therefore, it's being implemented to numerous new and existing water distribution systems worldwide. However, due to the complexity of water distribution systems, especially large-scale and highly looped systems, it is still very difficult to define the optimal boundary of DMAs considering all the aspects of water distribution system management requirements. In this study, a DMA design methodology (or a DMA design model) was developed with Geographic Information Systems (GIS) and hydraulic distribution system model to determine the optimal DMA boundary.

Optimal Design and Operation of Pump and Tank in Water Transmission Network (상수도 송수펌프, 배수지의 최적설계 및 운영 모형 개발)

  • Son, Won Il;Kim, Kang Min;Kang, Doosun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.158-158
    • /
    • 2017
  • 상수관망을 통한 용수 공급에서는 송수펌프, 배수지 등의 수리 시설물이 중요한 역할을 수행한다. 우리나라의 송 배수 방식은 송수펌프를 통해 고지대의 배수지에 물을 확보하고, 이를 자연유하 방식으로 공급하는 것이 일반적이며, 따라서 송 배수시스템의 운영이란 송수펌프의 가동과 그에 따른 배수지의 수위 현황을 관리하는 것을 의미한다. 이 때, 펌프의 가동을 위한 전력소모에 많은 비용이 발생되므로 효율적인 펌프 운영을 위한 최적화 연구의 필요성이 제기되었다. 기존 연구를 통해 송 배수시스템의 운영을 모의하고, 펌프 가동비용을 최소화 하는 실시간 최적 펌프운영 모형이 개발되었으나, 미리 결정된 펌프와 배수지를 바탕으로 송 배수시스템을 모의하기 때문에 계획 및 설계 단계에서 이를 활용할 수 없는 한계점이 존재하였다. 본 연구에서는 최적화 알고리즘 중 하나인 유전자 알고리즘(Genetic Algorithm, GA)을 사용하여, 실시간 펌프운영뿐만 아니라 송수펌프와 배수지의 효율적인 용량을 제시할 수 있는 최적화 모형을 개발하였다. 특히, 개발 모형은 펌프와 배수지의 설계/운영 시, 국내 설계기준, 시설물 비용, 시간별 전력단가 등을 제약조건으로 고려하여 현실적인 결과를 도출할 수 있도록 개발되었다. 본 연구는 실제 운영 중인 S시의 광역상수도 시스템을 바탕으로 개발 모형을 적용하였으며, 또한 송 배수시스템의 계획 및 관리에 활용할 수 있을 것으로 기대된다.

  • PDF

Efficiency Evaluation of Genetic Algorithm Considering Building Block Hypothesis for Water Pipe Optimal Design Problems (상수관로 최적설계 문제에 있어 빌딩블록가설을 고려한 유전 알고리즘의 효율성 평가)

  • Lim, Seung Hyun;Lee, Chan Wook;Hong, Sung Jin;Yoo, Do Guen
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.294-302
    • /
    • 2020
  • In a genetic algorithm, computer simulations are performed based on the natural evolution process of life, such as selection, crossover, and mutation. The genetic algorithm searches the approximate optimal solution by the parallel arrangement of Schema, which has a short definition length, low order, and high adaptability. This study examined the possibility of improving the efficiency of the optimal solution by considering the characteristics of the building block hypothesis, which are one of the key operating principles of a genetic algorithm. This study evaluated the efficiency of the optimization results according to the gene sequence for the implementation in solving problems. The optimal design problem of the water pipe was selected, and the genetic arrangement order reflected the engineering specificity by dividing into the existing, the network topology-based, and the flowrate-based arrangement. The optimization results with a flowrate-based arrangement were, on average, approximately 2-3% better than the other batches. This means that to increase the efficiency of the actual engineering optimization problem, a methodology that utilizes clear prior knowledge (such as hydraulic properties) to prevent such excellent solution characteristics from disappearing is essential. The proposed method will be considered as a tool to improve the efficiency of large-scale water supply network optimization in the future.

A new approach to design isolation valve system to prevent unexpected water quality failures (수질사고 예방형 상수도 관망 밸브 시스템 설계)

  • Park, Kyeongjin;Shin, Geumchae;Lee, Seungyub
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.spc1
    • /
    • pp.1211-1222
    • /
    • 2022
  • Abnormal condition inevitably occurs during operation of water distribution system (WDS) and requires the isolation of certain areas using isolation valves. In general, the determination of the optimal location of isolation valves considered minimization of hydraulic failures as isolation of certain areas causes a change in hydraulic states (e.g., flow direction, velocity, pressure, etc.). Water quality failure can also be induced by changes in hydraulics, which have not been considered for isolation valve system design. Therefore, this study proposes a new isolation valve system design methodology to prevent unexpected water quality failure events. The new methodology considers flow direction change ratio (FDCR), which accounts for flow direction changes after isolation of the area, as a constraint while reliability is used as the objective function. The optimal design model has been applied to a synthetic grid network and the results are compared with the traditional design approach. Results show that considering FDCR can eliminate flow direction changes while average pressure and coefficient of variation of pressure, velocity, and hydraulic geodesic index (HGI) outperform compared to the traditional design approach. The proposed methodology is expected to be a useful approach to minimizing unexpected consequences by traditional design approaches.

Optimal design and operation of water transmission system (상수도 송·배수시스템의 최적 설계 및 운영 모형 개발)

  • Choi, Jeongwook;Jeong, Gimoon;Kim, Kangmin;Kang, Doosun
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.12
    • /
    • pp.1171-1180
    • /
    • 2018
  • Korea's water transmission system is operated by the nonpressure flow method that flows from highlands to lowlands due to the nature of Korea with many mountainous areas. In order to store water in the highlands, the water pumps are installed and operated. However, In this process, a lot of electrical energy is consumed. therefore, it is necessary to minimize the energy consumption by optimizing the size and operation schedule of the water pumps. The optimal capacity and operation method of the water pump are affected by the size of the tank (distributing reservoir). Therefore, in order to economically design and operate the water transmission system, it is reasonable to consider both the construction cost of the water pump and the tank and the long-term operation cost of the water pump at the step of determining the scale of the initial facilities. In this study, the optimum design model was developed that can optimize both the optimal size of the water pump and the tank and the operation scheduling of the water pump by using the genetic algorithm (GA). The developed model was verified by applying it to the water transmission systems operated in Korea. It is expected that this study will help to estimate the optimal size of the water pump and the tank in the initial design of the water transmission system.

Optimal Design of Water Distribution Networks using the Genetic Algorithms: (I) -Cost optimization- (Genetic Algorithm을 이용한 상수관망의 최적설계: (I) -비용 최적화를 중심으로-)

  • Shin, Hyun-Gon;Park, Hee-Kyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.1
    • /
    • pp.70-80
    • /
    • 1998
  • Many algorithms to find a minimum cost design of water distribution network (WDN) have been developed during the last decades. Most of them have tried to optimize cost only while satisfying other constraining conditions. For this, a certain degree of simplification is required in their calculation process which inevitably limits the real application of the algorithms, especially, to large networks. In this paper, an optimum design method using the Genetic Algorithms (GA) is developed which is designed to increase the applicability, especially for the real world large WDN. The increased to applicability is due to the inherent characteristics of GA consisting of selection, reproduction, crossover and mutation. Just for illustration, the GA method is applied to find an optimal solution of the New York City water supply tunnel. For the calculation, the parameter of population size and generation number is fixed to 100 and the probability of crossover is 0.7, the probability of mutation is 0.01. The yielded optimal design is found to be superior to the least cost design obtained from the Linear Program method by $4.276 million.

  • PDF

Optimal Design of Water Distribution Networks using the Genetic Algorithms:(II) -Sensitivity Analysis- (Genetic Algorithm을 이용한 상수관망의 최적설계: (II) -민감도 분석을 중심으로-)

  • Shin, Hyun-Gon;Park, Heekyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.2
    • /
    • pp.50-58
    • /
    • 1998
  • Genetic Algorithm (GA) consists of selection, reproduction, crossover and mutation processes and many parameters including population size, generation number, the probability of crossover (Pc) and the probability of mutation (Pm). Determining values of the parameters is found critical in the whole optimization process and a sensitivity analysis with them seems mandatory. This paper tries to demonstrate such importance of sensitivity analysis of GA using an example water supply tunnel network of the New York City. For optimization of the network with GA, Pc and Pm vary from 0.5 to 0.9 by an increment of 0.1 and from 0.01 to 0.05 by an increment of 0.01, respectively, while fixing both the population size and the generation number to 100. This sensitivity analysis results in an optimum design of 22.3879 million dollars at the values of 0.8 and 0.01 for Pc and Pm, respectively. In addition, the probability of recombination (Pr) is introduced to check its applicability in the GA optimization of water distribution network. When Pr is 0.05 with the same values of Pc and Pm as above, the optimum design costs 20.9077 million dollars. This is lower than the cost of 22.3879 million dollars for the case of not using Pr by 6.6%. These results indicate that conducting a sensitivity analysis with parameter values and using Pr are useful in the optimization of WDN.

  • PDF