• Title/Summary/Keyword: 상수관맘

Search Result 1, Processing Time 0.018 seconds

Transient and Steady State Analysis considering Roughness and Reynolds Number in Water Distribution Systems (관조도와 난류를 고려한 부정류와 정상류 해석의 적용 연구)

  • Kim, Hyunsu;Song, Youngsuk;Kim, Sanghyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.3
    • /
    • pp.357-366
    • /
    • 2006
  • In order to compute pressure variation for a water distribution system, an expression for the friction factor as a function of Reynolds number and the relative roughness needs to be properly incorporated in computational algorithm. Considering Moody s friction variation, Developed Unsteady Network Analyzer (UNA) has been modified to match computational results with EPANET 2.0. Substantial improvement can be found in the application of Improved UNA to both an hypothetical pipeline network and a real system located in Ulsan City. Random number generator is employed to represent the uncertainty of water use in real pipeline network. Comparisons of application between EPANET 2.0 and improved UNA 2.0 indicate advantages and potentials of this approach.