• Title/Summary/Keyword: 상대기여도

Search Result 66, Processing Time 0.025 seconds

Developing the New Work Load Unit of Airport Based on the Relative Value of Cargo and Passenger (화물과 여객의 상대적 가치를 기준으로 하는 새로운 공항 처리량단위(WLU) 개발 연구)

  • BAEK, Sora;PARK, Yonghwa;LIM, Cheolhyun
    • Journal of Korean Society of Transportation
    • /
    • v.35 no.5
    • /
    • pp.434-446
    • /
    • 2017
  • This study was carried out to suggest new indicators to be used at airports. Generally, passengers and cargo will be handled at the airport, and the airport will achieve revenues through them. However, all airports can not have the same distribution of passenger and cargo throughput. When comparing and analyzing several airports, a uniform result can be expected only if a unit airport throughput indicator is applied. The 'Work Load Unit' is an indicator that integrates passengers and cargo into one, and assumes that the value of one passenger is equivalent to the cargo volume of 100kg. The existing WLU was set up based on the experience at the airport rather than being established through reasonable grounds or analysis, so there was a lot of controversy. The purpose of this study is to overcome these limitations and to suggest new index. In this study, we applied a method to compare the relative value of cargo and passenger to airport revenue. In order to analyze cargo value and passenger value, airport revenues are classified into aircraft operation related revenues, passenger handling related revenues, and commercial revenues. A total of 50 airports were selected, including 14 airports in Asia, 18 airports in Europe and 18 airports in North America. According to the final analysis results, it is concluded that the cargo is equivalent to 280kg of cargo based on the contribution of one passenger averagely. This is higher than the value of 100Kg cargo per passenger.

Analysis of Water Balance in Closed Transplants Production System (폐쇄형 묘생산 시스템의 수분 수지 분석)

  • Kim, J.K.;Kim, Y.H.;Choi, Y.H.;Lee, M.G.
    • Journal of Bio-Environment Control
    • /
    • v.12 no.3
    • /
    • pp.152-159
    • /
    • 2003
  • This study was conducted to analyze the water consumption in closed transplants production system (CTPS) for the production of quality transplants and to investigate the effect of relative humidity on the water balance in CTPS. Potato (Solanum tuberosum L. cv. Dejima) plug seedlings were grown for 15 days at air temperature of 20$^{\circ}C$, relative humidity of 70%, photoperiod of 16/8 h, and photosynthetic photon flux (PPF) of 200 ${\mu}mol{\cdot}m^{-2}{\cdot}s^{-l}$ following rooting for 5 days in CTPS. Amount of humidified, dehumidified, irrigated and evapotranspirated water were 67.9 kg${\cdot}m^{-2},\;196.9{\cdot}m^{-2},\;44.3\;kg{\cdot}m^{-2},\;33.5\;kg{\cdot}m^{-2}$, respectively. Water content of media and plants were 1.2 kg${\cdot}m^{-2},\;6.9\;kg{\cdot}m^{-2}$, respectively. Three relative humidity levels of 60, 70, and 80% were provided to analyze the effect of humidity on the water balance in CTPS. Amount of humidified, dehumidified, irrigated, evapotranspiratad water and water contents of media and plants increased with increasing relative humidity. Since the water consumption required to produce plug seedlings in CTPS dec1eased with decreasing relative humidity, the available water utilization efficiency of CTPS increased with decreasing relative humidity. CTPS showed high available water utilization efficiency of 0.92 - 0.97 if dehumidified water in CTPS was recycled. The development of CTPS with recycling system of dehumidified water will not only reduce the water consuming for the production of transplants but contribute to the establishment of plant production economizing in water consumption.

Growth and Yield Characteristics of Rice Varieties Developed in Different Years (육성년도가 다른 벼 품종의 생육 및 수량특성)

  • 임준택;신동영;김학진
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.38 no.4
    • /
    • pp.343-349
    • /
    • 1993
  • This study was conducted 1)to determine the factors responsible for the gradually increased rice yield by examining any improvements in yield-related characters and physiological characters among the historically recommended varieties of rice in Korea, and 2)to reveal the way of achieving further yield improvement by breeding in the future. Eight recommended varieties from 1911 to 1988 were selected and grown at the same conditions. The yield-related characters were observed at the harvest time, and the physiological characters such as RGR, NAR, LAR, SLA and L WR were estimated by the classical method of growth analysis. The newer varieties are shorter and those released after 1970's are greater in percent of filled spikelets and harvest index than the older varieties. There are no definite changing trends in the variations of number of panicles per hill, number of spikelets per panicle and 1000 grain weight according to the course of evolution in the recommended varieties. There is little evidence of improvement in the physiological characters such as NAR, LAR, SLA and LWR among the recently developed varieties compared with those of the older varieties. The increase in grain yield due to variety improvement, if any, is largely associated with the greater harvest index and percent of filled spikelets by breeding blight resistant and / or lodging resistant genotypes with short culm. It is suggested that increase in NAR should be carried out simultaneously with increase in harvest index to breed high yielding genotypes. I t appears to be important to breed genotypes with long culm in order to enhance light penetration into the canopy as long as they are lodging resistant. Since NAR is negatively correlated with LAR, it is unlikely to succeed to improve both characters simultaneously. The direct effect of NAR on RGR by path analysis is much larger than that of LAR, and hence it is suggested that breeding genotype with large NAR is more effective on enhancing RGR. It is also suggested that improving LAR through LWR is likely effective on increasing RGR.

  • PDF

A study on quality assurance and evaluation of uncertainty for the analysis of natural gas (천연가스 분석의 불확도 평가 및 품질 보증을 위한 연구)

  • Woo, Jin-Chun;Kim, Young-Doo;Bae, Hyun-Kil;Lee, Kang-Jin;Her, Jae-Young
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.490-497
    • /
    • 2006
  • The sources of uncertainty in the analysis of liquified natural gas (LNG) process are evaluated. The uncertainty sources evaluated are the repeatability of measurement, non-linearity of GC, the uncertainty of standard gas used for calibration, difference of gas sampling and deviation after GC calibration and major revealed sources are the non-linearity of GC, the uncertainty of standard gas and the deviation after GC calibration. The determined values and uncertainties of methane and ethane as the major components are $90.0%mol/mol{\pm}1.9%$ (relative and 95% level of confidence) and $6.26%mol/mol{\pm}0.08$ (relative and 95% level of confidence), respectively. The contribution of uncertainty varies depending on the source of uncertainty and gas component. In the case of methane, non-linearity of GC, the uncertainty of standard gas and deviation after GC calibration contribute 0.28%, 0.25% and 0.24% of relative expanded uncertainty, respectively.

Capacitance Characteristics of Fly Ash for Monitoring the Unburned Carbon Contained in Fly Ash (석탄회 미연탄소함량 동시측정을 위한 석탄회 정전용량 분석에 관한 연구)

  • 이재근;김장우;구재현;신진혁;김성찬;신희수;황유진
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.67-73
    • /
    • 2002
  • The carbon-in-ash system for simultaneously monitoring the unburned carbon in fly ash produced in a coal-fired power plan is designed and evaluated using the domestic fly ash produced in the coal-fired power plant. Real time monitoring is very important to control the combustion of the boiler in the coal-fired power plant and the purification system for fly ash recycling. The carbon-in-ash system based on the capacitance measurement consists of a LCR meter, a duct collector and an electrode cell. The capacitance of fly ash increases linearly with increasing fly ash carbon contents. The water content in fly ash plays an important role on the ash capacitance. The empirical equation for predicting the content of unburned carbon in fly ash produced in the domestic Boryung, Hadong and Samchenpo coal-fired power plants can be derived in the range of carbon content 0-20%.

THE RELATIVE CONTRIBUTIONS OF ELECTRIC FIELD AND IONOSPHERIC CONDUCTANCE TO THE AURORAL ELECTROJETS (오로라 제트전류에 대한 전기장과 전기전도도의 상대적 기여도)

  • 조은아;안병호;문용재
    • Journal of Astronomy and Space Sciences
    • /
    • v.17 no.1
    • /
    • pp.87-98
    • /
    • 2000
  • We examine the relative contributions of the electric field and ionospheric conductance to the auroral electrojets. For this purpose we used magnetometer data obtained from the International Magnetospheric Study (IMS) meridian chains of observatories for March 17, 18, and 19, 1978. Based on the study by Allen & Kroehl (1975), we redefine the AU and AL indices by utilizing the magnetic disturbance data obtained from the AE stations located within limited magnetic local time (MLT) sectors; i.e., $1500\leq MLT\leq1800$ and$0000\leq MLT\leq0300$, respectively. The current densities of the eastward and westward electrojets are calculated based on the AU and AL indices thus defined. Under the assumption that the Hall conductance at the dusk sector is mainly caused by the solar EUV radiation, we estimate the electric field contributin to the AU index. Assuming further that electric field distributins at dawn and dusk sectors are comparable, it is also possible to estimate the contribution of the Hall conductance associated at the dusk sector is mainly caused by the solar EUV radiation, we estimate the electric field contribution to the AU index. Assuming further that electric field distributions at dawn and dusk sectors are comparable, it is also possible to estimate the contribution of the Hall conductance associated with auroral particle precipitation to the AL index. From this study it is noted that the electric fields and Hall conductances thus estimated show significant correlations with the AU and AL indices, respectively, suggesting that the AU and AL indices are closely associated with the directly driven and loading-unloading processes of substorms.

  • PDF

Analysis of Economic Effectiveness for Flood Control of Dam (댐의 홍수조절에 의한 경제적 효과분석)

  • Choi, Seung-An;Yi, Choong-Sung;Shim, Myung-Pil;Kim, Hung-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.5
    • /
    • pp.383-396
    • /
    • 2007
  • The studies on efficiency of flood control reservoir has been introduced into four categories including direct flood control contribution by reservoir, flow-duration change and environmental-ecological change in downstream of dam and flood damage estimation of flood plain. In spite of all the previous approaches, the quantification of the effect of reservoir on the flood control in planning stage is quite complex due to lack of a standard for quantifying feasibility of project. In this study, we develop a methodology that can clearly and accurately quantify the flood damage reduction together with the existing flood level reduction at downstream. The proposed approach uses three appraisal standards of flood control: 'potential safety', 'relative risk' and 'absolute risk' according to the risk by stage. The developed methodology was applied to the Namhan river basin with the storm event of July, 2006. The result shows the damage reduction of 4,189 billion won was estimated. The economic benefits for the flood control effect by dam will greatly contribute to the public understanding of the importance and the effect of the flood control by dam.

Comparative molecular field analyses (CoMFA) on the antifungal activity against phytophthora blight fungus of 3-phenylisoxazole and 3-phenyl-2,5-dihydroisoxazol-5-one derivatives (고추 역병균에 대한 3-phenylisoxazole과 3-phenyl-2,5-dihydroisoxazol-5-one 유도체들의 살균 활성에 관한 비교 분자장 분석 (CoMFA))

  • Sung, Nack-Do;Lee, Hee-Chul
    • The Korean Journal of Pesticide Science
    • /
    • v.6 no.2
    • /
    • pp.72-79
    • /
    • 2002
  • 3D-QSAR between fungicidal activitives ($pI_{50}$) against metalaxyl-sensitive (SPC: 95CC7105) or metalaxyl-resisitant (RPC: 95CC7303) isolate of phytophthora blight fungus (Phytophthora capsici), and a set of 3-phenylisoxazole (A) and 3-phenyl-2,5-dihydroisoxazole (B) derivatives as substrates were conducted using comparative molecular field analyses (CoMFA). The antifungal activities of (A) were generally higher than those of (B). And it is assumed that the most stable conformation of the active substrate was approximately planar from conformational search. The CoMFA models proved a good predictive ability and suggested that the electronic field of substrates were higher than hydropohobic field and steric field requirements for recognition forces of the receptor site. And the factors were strongly correlated (cross-validated $q^2>0.570$ & conventional $r^2>0.968$) with the fungicidal activitives. According to the CoMFA analyses, the selectivity factors for RPC suggested that the sterically bulky groups (C14 & C15) and electron withdrawing groups (C15 & C16) have to be introduced to the ortho, meta and para-position on the benzoyl moiety of substrates.

The Effects of the topographical, Soil and Meterological Factors on the Tree Height Growth in the Pinus thunbergii Stands (지형(地形), 토양(土壤) 및 기상인자(氣象因子)가 해송(海松)의 수고생장(樹高生長)에 미치는 영향(影響))

  • Son, Yeong Mo;Chung, Young Gwan
    • Journal of Korean Society of Forest Science
    • /
    • v.83 no.3
    • /
    • pp.380-390
    • /
    • 1994
  • This study was conducted to investigate the effects of the topographical factors (16 items), physico-chemical properties of soil (13 items) and meteorological factors(9 items) on the height growth of Pinus thunbergii stands along the coastal area in Korea. According to the coefficients by partial correlation analysis in total area, it was found that tree height growth was considerably affected by local topography, soil hardness, soil B-horizental depth, effective soil depth, soil moisture, parent rock, soil texture, and etc.. And the soil factors were available $P_2O_5$, total nitrogen, base saturation, exchangeable $Ca^{{+}+}$, and etc.. In partial correlation analysis, annual relative humidity, annual precipitation, index of aridity, and etc. were found to be the most important factors influencing on tree height growth of Pinus thunbergii stands. In conlusion, the topographical, soil and meteorological factors have multiplex influence on the tree height growth in the Pinus thunbergii stands. They promise to provide the basis of improving not only the selection of suitable sites and the management of soil fertilizer but also the estimation of growth and yield. Hence these results would be used successfully for the design in the scientific forest working plan.

  • PDF

Recirculating Integrated System for the Treatment of Authentic Integrated-textile-dyeing Wastewater from Dyeing Industrial Complex (염색산업단지 종합폐수처리용 재순환 통합시스템)

  • Lee, Eun Ju;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.55 no.6
    • /
    • pp.837-845
    • /
    • 2017
  • A recirculating integrated system composed of a fluidized biofilter filled with waste-tire crumb media fixed with return sludge from wastewater treatment facility of D dyeing industrial center, and a UV/photocatalytic reactor packed with calcined $TiO_2$ coated-glass beads as photocatalyst-support, was constructed and was run to treat authentic textile-dyeing wastewater from D-dyeing industrial center, which was mixed with an alkaline polyester-weight-reducing wastewater and a wastewater from sizing process. As a result, its total removal efficiency(RE(tot)) of $COD_{cr}$ and colors were ca. 81% and 55%, respectively. The synergy effect of the recirculating integrated system to enhance total removal efficiency(RE(tot)) of $COD_{cr}$ and colors were evaluated at most ca. 7% and 3%, respectively. The fluidized biofilter and the UV/photocatalytic reactor were responsible for ca. 94% and 6% of the total $COD_{cr}$ removal efficiency, respectively, and were also responsible for ca. 86% and 14% of the total color-removal efficiency, respectively. Thus, the degree of the UV/photocatalytic reactor-unit process's contribution to RE(tot) of color, was about 2.4 times of that to RE(tot) of $COD_{cr}$. Therefore, the UV/photocatalytic reactor facilitated the more effective elimination of colors by breaking down the chemical bonds oriented from colors of dyes such as azo-bond, than $COD_{cr}$. In addition, the effect of the removal efficiency of each unit process(i.e., the fluidized biofilter or the UV/photocatalytic reactor) of the recirculating integrated system on RE(tot) of $COD_{cr}$ and colors, was analysed by establishing its model equation with an analytic correlation.