• Title/Summary/Keyword: 상관계수들의 등가성

Search Result 14, Processing Time 0.022 seconds

Testing the Equality of Several Correlation Coefficients by Permutation Method

  • Um, Yonghwan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.6
    • /
    • pp.167-174
    • /
    • 2022
  • In this paper we investigate the permutation test for the equality of correlation coefficients in several independent populations. Permutation test is a non-parametric testing methodology based upon the exchangeability of observations. Exchangeability is a generalization of the concept of independent, identically distributed random variables. Using permutation method, we may construct asymptotically exact test. This method is asymptotically as powerful as standard parametric tests and is a valuable tool when the sample sizes are small and normality assumption cannot be met. We first review existing parametric approaches to test the equality of correlation coefficients and compare them with the permutation test. At the end, all the approaches are illustrated using Iris data example.

Evaluation of Blast Pressure Generated by an Explosion of Explosive Material (폭발성 물질의 폭발에 따른 폭발압력 평가)

  • Yoon, Yong-Kyun
    • Explosives and Blasting
    • /
    • v.36 no.4
    • /
    • pp.26-34
    • /
    • 2018
  • Explosions of vapor cloud formed due to the leakage from installations with flammable fuels have often occurred in Korea and foreign countries. In this study, TNT equivalency method and Multi-Energy method for vapor cloud explosion blast modelling are described and demonstrated in a case study. As TNT equivalency method is simple and direct, it has been widely used for modelling a vapor cloud explosion blast. But TNT equivalency method found to be difficult to select a proper correlation between the amount of combustion energy produced from the vapor cloud explosion and the equivalent amount of TNT to model its blast effects. Multi-Energy method assumes that the strength of vapor cloud explosion blast depends on the layout of the space where the vapor cloud is spreading. Strictly speaking, the explosive potential of a vapor cloud is dependent upon the density of the obstructed regions. In this study, Flixborough accident are analyzed as a case study to assess the applicability of TNT equivalency method and Multi-Energy method. TNT equivalency method and Multi-Energy method found to be applicable if coefficient of TNT equivalency and coefficient of strength of explosion blast are selected properly.

Estimation of Bed Resistance in Gravel-bed Rivers Using the Equivalent Roughness Height (등가조고를 이용한 자갈하천의 하상저항 산정)

  • Kim, Ji-Sung;Kim, Yong-Jeon;Lee, Chan-Joo;Kim, Won
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.8
    • /
    • pp.619-629
    • /
    • 2009
  • The objective of this study is to estimate bed-resistance in gravel-bed rivers using the equivalent roughness height($k_s$). We calculated the friction factor(f) with the measured data from 8 domestic gravel-bed rivers and investigated the size distributions of the bed materials. The averaged $k_s$ in each cross-section, which is determined under the hypothesis that the vertical velocity distribution follows the logarithmic law, is compared with the reach $k_s$ which is calculated with the cumulative grain diameter distribution curve of bed materials. Moreover, the applicability of existing formulae, such as Strickler type equations, is examined by comparing with Manning's n value converted from the $k_s$. According to the results, the reach $k_s$ proves to be a good indicator of representative characteristic of bed materials in a reach, and the Manning's n based on the reach $k_s$ is appropriate for practical estimation of the bed-resistance, for RMS errors between calculated and measured Manning's n is less than 0.003. The correlation between the $k_s$ and specified bed-material size($D_i$) is very low, so it is difficult to select a proper one among the existing empirical equations.

A New Method for Dilatometer Dissipation Analysis Using an Equivalent Radius and Optimization Technique (등가반경과 최적화기법을 이용한 딜라토메터 소산시험 해석법)

  • 김영상
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.5
    • /
    • pp.43-50
    • /
    • 2001
  • 딜라토메터는 실험의 간편성, 경제성, 신속성 및 반복성 등을 바탕으로 현장에서의 지반공학적 물성추정에 보편화되고 있다. 또한 간단한 장비구성과 손쉬운 사용법에도 불구하고 다양한 지반공학적 물성들 -예로서, $K_{o}$ , OCR, $c_{u}$ , $\psi$, $c_{h}$, $k_{h}$, ${\gamma}$, M, $u_{o}$ -을 추정할 수 있으며 다양한 지반공학적 설계문제에 성공적으로 적용되어 왔다. 그러나 제안된 관계식들이 대부분 기존실험 결과들과의 비교를 통하여 얻어진 경험적 상관관계이며, 특히 압밀계수 추정에 관한 부분은 관입시 평면변형 상태의 지반변형으로 인한 관입모사의 복잡성으로 인하여 피에조콘 소산시험 해석을 위해 제안된 이론 해들에 경험적인 가정사항들을 추가하여 사용하는 반경험적 방법들과 순수한 경험적인 방법이 사용되어 왔다. 본 연구에서는 elf라토메터 관입기의 실제 평면적을 등가의 원형반경으로 고려한 등가반경을 사용하고 최적화기법을 적용함으로써, 소산시험에서 실제 관측된 간극수압($p_2$)과 딜라토메터 소산시험을 모사하여 얻어진 예측 간극수압의 차이를 최소화하는 수평압밀계수 추정법을 제안하였다. 제안된 방법을 국내 양산지역에서 수행된 딜라토메터 소산실험에 적용하였으며 추정된 수평압밀계수 값을 기존의 딜라토메터 수평압밀계수 추정법들과 불교란 시료를 이용한 일차원 실내 압밀실험으로 얻어진 수평압밀계수 값들과 비교검증 하였다. 그 결과 제안된 방법으로 기존의 방법에 비해 실내 압밀실험 결과와 일치하는 수평압밀계수 추정결과를 얻었다. 또한, 제안된 방법으로 얻어진 수평압밀계수는 전 소산도 범위에서 고르게 관측값과 일치하는 소산곡선을 예측하여, 최적화기법을 이용한 딜라토메터 소산시험 해석으로 전 소산과정을 대표하는 압밀계수의 추정이 가능할 것으로 사료된다.

  • PDF

Urban Drainage Simplification Using Meta-channel Concept (등가하천 개념을 이용한 관망 간략화 기법에 대한 연구)

  • Kim, Hwan-Seok;Pak, Gi-Jung;Yoon, Jae-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1194-1199
    • /
    • 2007
  • 본 연구에서는 도시배수관망의 간략화 모의 시 지선을 단순 생략하는 것이 아니라 2차원 관망을 1차원으로 전환시키는 방법인 등가하천 개념을 도입하여 도시유역의 유출량 산정에 있어서 여러 지선들을 개별적으로 모의하지 않으면서도 실제 존재하는 지선들의 효과를 고려할 수 있는 방법을 개발하고자 하였다. 자연하천에 대해 개발된 등가하천 개념은 최근의 수문모형의 경향인 물리적 분포형 모형의 복잡성을 피하면서 전통적인 개념적 집중형 모형이 가지는 간편성을 살리고 그 것이 가지고 있는 선형가정의 한계를 극복하기 위한 방안으로서 제안된 방법이다. 등가하천 개념을 도입하여 개발된 모형은 종국적으로 강우-유출관계에 있어서 강우의 크기, 선형 및 비선형성, 유역면적 등이 미치는 영향을 분석하기위한 도구로 개발되었으며, 본 연구에서는 출구로부터 동일 거리 s에 위치한 지점에서의 배수관망의 공간적인 분포 및 집중패턴을 파악하는 폭함수(width function, n(s))와 면적함수(area function, M(s))를 이용하여 관망을 간략화 하였다. 등가관의 수리기하조건 결정은 유역이 정상상태에 도달했을 경우에 대해서 이루어지게 되며 정상상태 모의를 통해 개별 관망단면들에 대해 얻어진 유량(Q), 면적(A), 수심(y) 자료간의 상관관계를 유추하여 Q(A), A(y) 함수를 유도하게 되면 종국적으로 관로홍수추적에 이용되는 지배방정식의 매개변수인 파속계수(c) 및 확산계수(D)를 계산할 수 있게 된다. 본 연구에서는 대상 유역으로 군자 배수구역을 선정하여 유역의 특성과 관망 자료를 수집하고 간략화 기법을 적용한 결과를 분석 하였다.다. 21세기 문화산업에서 우리가 판단하게 될 디자인의 가치는 계몽의 원리에 대한 '역사성'과 '현재성'의 변증법에 달려있는 것이며, 새로운 철학, 새로운 문명, 새로운 세계를 열어가는 것이다.r$ (地理志)에는 추현리와 이미 외리를 언급하면서 상주의 자기제작의 위상을 짐작하는 기록이 언급되면서 전국의 상품의 절반을 담당하고 있었음을 알 수 있었다. $\ulcorner$경상도지리지$\lrcorner$(慶尙道地理志)에는 상주가 8곳으로 1/3의 자기 생산을 담당하고 있었다. $\ulcorner$경상도지리지$\lrcorner$(慶尙道地理志)에는 $\ulcorner$세종실록$\lrcorner$(世宗實錄) $\ulcorner$지리지$\lrcorner$(地理志)와 동년대에 동일한 목적으로 찬술되었음을 알 수 있다. $\ulcorner$경상도실록지리지$\lrcorner$(慶尙道實錄地理志)에는 $\ulcorner$세종실록$\lrcorner$(世宗實錄) $\ulcorner$지리지$\lrcorner$(地理志)와의 비교를 해보면 상 중 하품의 통합 9개소가 삭제되어 있고, $\ulcorner$동국여지승람$\lrcorner$(東國與地勝覽) 에서는 자기소와 도기소의 위치가 완전히 삭제되어 있다. 이러한 현상은 첫째, 15세기

  • PDF

Scale-Up Factor for Seismic Analysis of Building Structure for Various Coordinate Systems (건축구조물의 지진해석에서 좌표축의 설정에 따른 보정계수 산정법)

  • Yu, Il-Hyang;Lee, Dong-Guen;Ko, Hyun;Kim, Tae-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.5
    • /
    • pp.33-47
    • /
    • 2007
  • In a practical engineering, the equivalent static analysis (E.S.A) and the response spectrum analysis (R.S.A) are generally used for the seismic analysis. The base shears obtained from the E.S.A are invariable no matter how the principal axes of building structures are specified on an analysis program while those from the R.S.A are variable. Accordingly, the designed member size may be changed by how an engineer specify the principal axes of a structure when the R.S.A is used. Moreover, the base shears in the normal direction to the excitation axis are sometimes produced even when an engineer performs a response spectrum analysis in only one direction. This tendency makes the base shear, which is used to calculate the scale-up factor, relatively small. Therefore the scale-up factor becomes larger and it results in uneconomical member sizes. To overcome these disadvantages of the R.S.A, an alternative has been proposed in this study. Three types of example structures were adapted in this study, i.e. bi-direction symmetric structure, one-direction antisymmetric structure and bi-direction antisymmetric structure. The seismic analyses were performed by rotating the principal axes of the example structures with respect to the global coordinate system. The design member forces calculated with the scale-up factor used in the practice were compared with those obtained by using the scale-up factor proposed in this study. It can be seen from this study that the proposed method for the scale-up factor can provide reliable and economical results regardless of the orientation of the principal axes of the structures.

Verification of Frequency-Dependent Equivalent Linear Method (주파수 의존성을 고려한 등가선형해석기법의 검증)

  • Jeong, Chang-Gyun;Kwak, Dong-Yeop;Park, Du-Hee
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.12
    • /
    • pp.113-120
    • /
    • 2008
  • One-dimensional site response analysis is widely used to simulate the seismic site effects. The equivalent linear analysis, which is the most widely used type of site response analysis, is essentially a linear method. The method applies constant shear modulus and damping throughout the frequency range of the input motion, ignoring the dependence of the soil response on the loading frequency. A new type of equivalent linear analysis method that can simulate the frequency dependence of the soil behavior via frequency-strain curve was developed. Various forms of frequency-strain curves were proposed, and all curves were asserted to increase the accuracy of the solution. However, its validity has not been extensively proven and the effect of the shape of the frequency-strain curve is not known. This paper used two previously proposed frequency-strain curves and three additional curves developed in this study to evaluate the accuracy of the frequency-dependent equivalent linear method and the influence of the shape of the frequency-strain curves. In the evaluation, six recordings from three case histories were used. The results of the case study indicated that the shape of the frequency-strain curve has a dominant influence on the calculated response, and that the frequency dependent analysis can enhance the accuracy of the solution. However, a curve that results in the best match for all case histories did not exist and the optimum curve varied for each case. Since the optimum frequency-strain curve can not be defined, it is recommended that a suite of curves be used in the analysis.

A Study on the Equivalent Static Wind Load Estimation of Large Span Roofs (대스팬 지붕구조물의 등가정적 풍하중 산정에 관한 연구)

  • Lee, Myung-Ho;Kim, Ji-Young;Kim, Dae-Young;Kim, Sang-Dae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.6 no.1 s.19
    • /
    • pp.83-90
    • /
    • 2006
  • The GF(Gust Factor) method is usually used as a method to evaluate equivalent static wind loads for general structures. The GF method is performed on the assumption that the shape of the equivalent static wind load profile is typically similar to that of mean wind loads. The shape of fluctuating wind loads could be quite different with that of the mean wind loads in case of large-span structures. So, the effect of higher modes as well as first mode must be considered to evaluate the wind loads. In this study, the ACS (Advanced Conditional Sampling) method is suggested to evaluate of equivalent static wind loads after investigating about GF and LRC method. The An method ran derive effective static wind loads by combining wind pressures and inertia forces of a structure chosen at a maximum load effect. The maximum load effect is assessed with the time history analysis using pressure data measured in wind tunnel tests. Equivalent static wind loads evaluated using ACS, GF, and LRC methods are compared to verify the effectiveness of ACS method.

  • PDF

Comparison of Doses According to Change of Bladder Volume in Treatment of Prostate Cancer (전립선암 치료 시 방광의 용적 변화에 따른 선량의 비교 평가)

  • Kwon, Kyung-Tae;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.415-421
    • /
    • 2017
  • In the case of radiation therapy for prostate cancer, a balloon infused with a certain amount of air through the anus is used to reduce rectal dose. Because of the reason, radiation therapy for prostate cancer has acquired CBCT for daily image induction. In order to maintain the anatomical structure most similar to the first CT taken before treatment, it is pretreated, but it can not be said to be perfectly consistent. In two actual treatment regimens, the volume of the bladder was measured as 45.82 cc and 63.43 cc, and the equivalent diameter was 4.4 cm and 4.9 cm. As a result of this study, the mean volume of the bladder was estimated to be 56.2 cc, 105.6 cc by 20 CBCT. The mean dose of CBCT was 1.74% and the mean Bladder mean dose was 96.67%. In case B, PTV mean dose was 4.31%, Bladder mean Dose was estimated to be 97.35%. The changes in the volume of the bladder resulted in changes in the dose of PTV and bladder. The correlation coefficient of bladder dose according to the change of bladder volume showed linearity of mean dose $R^2=-0.94$. The correlation coefficient of the PTV dose according to the volume change of the bladder showed linearity of mean dose $R^2=0.04$. It was found that the dose change of PTV was larger than that of bladder according to the change of bladder volume.

Human Thermal Sensation and Comfort of Beach Areas in Summer - Woljeong-ri Beach, Gujwa-eup, Jeju-si, Jeju Special Self-Governing Province - (여름철 해변지역의 인간 열환경지수 및 열쾌적성 - 제주특별자치도 제주시 구좌읍 월정리 해변 -)

  • Park, Sookuk;Sin, Jihwan;Jo, Sangman;Hyun, Cheolji;Kang, Hoon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.4
    • /
    • pp.100-108
    • /
    • 2016
  • The climatic index for tourism(CIT) has recently been advanced, which includes complete human energy balance models such as physiological equivalent temperature(PET) and universal thermal climate index(UTCI). This study investigated human thermal sensation and comfort at Woljung-ri Beach, Jeju, Republic of Korea, in spring and summer 2015 for landscape planning and design in beach areas. Microclimatic data measurements and human thermal sensation/comfort surveys from ISO 10551 were conducted together. There were 869 adults that participated. As a result, perceptual and thermal preference that consider only physiological aspects had high coefficients of determination($r^2$) with PET in linear regression analyses: 92.8% and 87.6%, respectively. However, affective evaluation, personal acceptability and personal tolerance, which consider both physiological and psychological aspects, had low $r^2s$: 60.0%, 21.1% and 46.4%, respectively. However, the correlations between them and PET were all significant at the 0.01 level. The neutral PET range in perceptual for human thermal sensation was $25{\sim}27^{\circ}C$, but a PET range less or equal to 20% dissatisfaction, which was recommended by ASHRAE Standard 55, could not be achieved in perceptual. Only PET ranges in affective evaluation and personal tolerance affected by both aspects were qualified for the recommendation as $21{\sim}32^{\circ}C$ and $17{\sim}37^{\circ}C$, respectively. Therefore, the PET range of $21{\sim}32^{\circ}C$ is recommended to be used for the human thermal comfort zone of beach areas in landscape planning and design as well as tourism and recreational planning. PET heat stress level ranges on the beach were $2{\sim}5^{\circ}C$ higher than those in inland urban areas of the Republic of Korea. Also, they were similar to high results of tropical areas such as Taiwan and Nigeria, and higher than those of western and middle Europe and Tel Aviv, Israel.