• Title/Summary/Keyword: 삽입기구

Search Result 103, Processing Time 0.032 seconds

The Development of Pin Screws into the Bone for External Fixator (체외 고정구용 골 삽입 금속 나사 개발)

  • Choi, Y.C.;Rhee, K.M.;Na, W.H.;Song, B.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.2 no.1
    • /
    • pp.5-17
    • /
    • 2009
  • We developed bone-insertion pin screw that can be used for purposed treatment by combining with the external fixator which is the subsidiary tool for the healing of the fracture (open fracture of long bone, reconstruction of soft tissue and arthrodesis etc.) Furthermore, for the frist time, we succeeded in domestic-producing this screw, using specially-designed treating tool stuck on the lathe machine and abrasive blasting machine, and the post-dealing technique and process. In comparison with other foreign products, we could get more desirable results in various tests. This pin screw has 103% characteristics of the average of foreign products. Thus we'd like to introduce design techniques, post-dealing process and result of function tests.

  • PDF

Performance of the Negative Carbon Electrode Prepared with Graphitic Carbon and Nongraphitic Carbon Material in Lithium Ion Secondary Battery (흑연계 및 비흑연계 탄소로 조합된 리튬이온 이차전지의 탄소부극 특성)

  • Kim, Hyun-Joong;Lee, Chul-Tae
    • Applied Chemistry for Engineering
    • /
    • v.9 no.7
    • /
    • pp.1065-1069
    • /
    • 1998
  • This study was investigated to improve peformance of carbon negative electrode for lithium ion secondary battery. The carbon electrode was prepared by mixing with graphitic carbon material, natural graphite, and nongraphitic carbon material, petroleum cokes, which was heat-treated at $700^{\circ}C$ for l hour. Its electrochemical and charge-discharge characteristics were tested according to mixing ratio of different two types of carbon material. The carbon electrode prepared with various mixing ratio showed both charateristcs of two different types of carbon materials and the best characteristics as carbon electrode was demonstrated at mixing ratio of 1:1.

  • PDF

Multimedia Watermark Detection Algorithm Based on Bayes Decision Theory (Bayes 판단 이론 기반 멀티미디어 워터마크 검출 알고리즘)

  • 권성근;이석환;김병주;권기구;하인성;권기룡;이건일
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.7A
    • /
    • pp.695-704
    • /
    • 2002
  • Watermark detection plays a crucial role in multimedia copyright protection and has traditionally been tackled using correlation-based algorithms. However, correlation-based detection is not actually the best choice, as it does not utilize the distributional characteristics of the image being marked. Accordingly, an efficient watermark detection scheme for DWT coefficients is proposed as optimal for non-additive schemes. Based on the statistical decision theory, the proposed method is derived according to Bayes decision theory, the Neyman-Pearson criterion, and the distribution of the DWT coefficients, thereby minimizing the missed detection probability subject to a given false alarm probability. The proposed method was tested in the context of robustness, and the results confirmed the superiority of the proposed technique over conventional correlation-based detection method.

Design of the Interspinous Process Fixator Using Biomechanical Analysis for the Treament of Degenerative Lumbar Spinal Stenosis (퇴행성 요추부 척추관 협착증 치료를 위한 극돌기간 고정기구의 설계 및 생체역학적 분석)

  • Heo S.;Son K.;Lee S.J.;Moon B.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1963-1966
    • /
    • 2005
  • Degenerative lumbar spinal stenosis(DLSS) is a disease inducing low back pain, leg pain, convulsion, numbness, and neurogenic claudication from compression of nerve root. Intervertebra fixation was reported to increase the degenerative of neighbor region after treatment. Recently, a new surgical technique of inserting a fixator between interspinous processes has been introduced. The purpose of this study is to design of the interspinous process fixator with flexibility to complement the trouble of using fixator in DLSS. This study evaluated the existing fixator through the mechanical test and modified fixators using the finite element analysis(FEA). Displacement, stiffness and Von-Mises stress were found to have similar values to those obtained from the mechanical test and the FEA in the biomechanical loading condition. Effects of variation in length and thickness were investigated to design an optimal fixator.

  • PDF

Biomechanical Analysis of Lumbar Interspinous Process Fixators (요추부 극돌기간 고정기구의 생체역학적 해석)

  • Heo Soon;Park Jung-Hong;Lee Sung-Jae;Son Kwon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.3 s.180
    • /
    • pp.195-202
    • /
    • 2006
  • The degenerative lumbar spinal stenosis (DLSS) is a disease inducing low back pain, leg pain, convulsion. numbness, and neurogenic claudication from compression of nerve root. Intervertebra fixation was reported to increase the degeneration of neighbor lesion after treatment. Recently, a new surgical technique of inserting a fixator between interspinous processes has been introduced. The purpose of this study is to design the interspinous process fixator with flexibility to complement the trouble of using fixator in DLSS. This study evaluated the existing fixator through the mechanical test and modified it using the finite element analysis (FEA). The evaluation was based on the displacement, stiffness and von-Mises stress obtained from the mechanical test and calculated from the FEA in the biomechanical loading condition. Effects of variation in length and thickness were investigated to design an optimal fixator. Three prototypes were manufactured using FEA results. Mechanical tests under the biomechanical loading condition were performed to select the best one from these three. The selected fixator increased flexiblity by 32.9%.

Multi-element Ultrasound Applicator for the Treatment of Cancer in Uterus and Cervix (자궁암 치료용 다채널 초음파 온열치료기)

  • Lee Rena
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.16-23
    • /
    • 2005
  • The objective of this study was to construct multi-element ultrasound applicators for the treatment of gynecologic cancer with high dose rate brachytherapy. For the treatment of uterus, piezo-ceramic crystal transducer (PZT -5A) with outer diameter of 4 mm, wall thickness of 1.3 mm, and length of 24.5 mm was selected. For the treatment of cervix or vagina, it should be possible to insert the applicator into the vagina. Thus, a cylindrical PZT -8 material with outer diameter of 24.5 mm, wall thickness of 1.3 mm, and length of 15.2 mm was selected. The operating frequencies determined by vector impedance measurement were 3.2 MHz for the PZT 5A cylinder (OD=4 mm) and 1.7 MHz for the PZT -8 cylinder (OD: 24.5 mm). The ratios of generated acoustic output power to applied electric power were 33% and 61% for the tandem type crystal and the cylinder type crystal, respectively. The radiated acoustic pressure fields from both transducers were calculated using a Matlab code and measured in water using hydrophone. There was good agreement between measured and calculated acoustic pressure field distribution. For a tandem type transducer, the calculated acoustic pressure field decreased from 0.023 MPa at 10 mm to 0.010 Mpa at 30 mm, the reduction of 57%. For the cylinder type transducer which will be used for the treatment of vagina showed 78% reduction at 15 mm and 66% at 25 mm as compared to values at 5 mm from the surface. Based on the characteristics of the transducers, this study demonstrated the possibility of using the crystals as a heating source. Finally, a 3-element and 4-element prototype applicators were constructed. The 3-element applicator is 75 mm long and 4 mm thick and will be used for the treatment of uterus. The 4-element applicator is 61 mm long and 24.5 mm thick and will be used for the treatment of vagina. Using these applicators, it is possible to generate enough power to increase temperature to therapeutic level.

  • PDF

Implementation of Man-made Tongue Immobilization Devices in Treating Head and Neck Cancer Patients (두 경부 암 환자의 방사선치료 시 자체 제작한 고정 기구 유용성의 고찰)

  • Baek, Jong-Geal;Kim, Joo-Ho;Lee, Sang-Kyu;Lee, Won-Joo;Yoon, Jong-Won;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • Purpose: For head and neck cancer patients treated with radiation therapy, proper immobilization of intra-oral structures is crucial in reproducing treatment positions and optimizing dose distribution. We produced a man-made tongue immobilization device for each patient subjected to this study. Reproducibility of treatment positions and dose distributions at air-and-tissue interface were compared using man-made tongue immobilization devices and conventional tongue-bites. Materials and Methods: Dental alginate and putty were used in producing man-made tongue immobilization devices. In order to evaluate reproducibility of treatment positions, all patients were CT-simulated, and linac-gram was repeated 5 times with each patient in the treatment position. An acrylic phantom was devised in order to evaluate safety of man-made tongue immobilization devices. Air, water, alginate and putty were placed in the phantom and dose distributions at air-and-tissue interface were calculated using Pinnacle (version 7.6c, Phillips, USA) and measured with EBT film. Two different field sizes (3$\times$3 cm and 5$\times$5 cm) were used for comparison. Results: Evaluation of linac grams showed reproducibility of a treatment position was 4 times more accurate with man-made tongue immobilization devices compared with conventional tongue bites. Patients felt more comfortable using customized tongue immobilization devices during radiation treatment. Air-and-tissue interface dose distributions calculated using Pinnacle were 7.78% and 0.56% for 3$\times$3 cm field and 5$\times$5 cm field respectively. Dose distributions measured with EBT (international specialty products, USA) film were 36.5% and 11.8% for 3$\times$3 cm field and 5$\times$5 cm field respectively. Values from EBT film were higher. Conclusion: Using man-made tongue immobilization devices made of dental alginate and putty in treatment of head and neck cancer patients showed higher reproducibility of treatment position compared with using conventional mouth pieces. Man-made immobilization devices can help optimizing air-and-tissue interface dose distributions and compensating limited accuracy of radiotherapy planning systems in calculating air-tissue interface dose distributions.

  • PDF

Nd:YAG 레이저를 이용한 증기 발생기 전열관 sleeve 보수 용접 연구

  • 정진만;권성옥;김철중
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.961-966
    • /
    • 1995
  • 국내 상업적으로 운용증인 경수로 원자력 발전소중, 중기발생기의 건전성 유지를 위하여 보수 유지에 많은 비용을 소비하고 있다 특히 중기발생기 전열관으로 사용되는 inconel 600 재질에 많은 문제점이 발생되었다. 전열관 파손에 대한 보수 및 방지기술은 plugging, sleeving, shot penning, Ni-plating 등이 있다. 특히 최근에 개발된 고출력 Nd:YAG 레이저를 이용한 sleeving 보수 기술이 개발되었다. Nd:YAG 레이저를 이용한 보수 방식은 미국의 WH 및 일본의 MHI 등이 선정하여 실용화 단계에 있으며, 이는 광섬유로 전송이 가능한 Nd:YAG 레이저를 이용하여 원격으로 가공할 수 있는 기술이다. 현재 한국 원자력 연구소에서는 전열관 레이저 보수 용접에 대한 개념을 확립하고 장비 및 기구를 개발하였으며, 고리 1 호기 전열관규격에(7/8") 3/4" sleeve tube를 삽입하여 약 50 m 떨어진 곳으로부터 원격 레이저 용접을 실험실적 규모로 실증 하였다.모로 실증 하였다.

  • PDF

Improvement of VAD Performance using the LSP Variation in the G.723.1 (LSP변화도를 이용한 G-723.1 보코더의 VAD 성능향상에 관한 연구)

  • LEE HeeWon;NA Ducksu;BAE MyungJin
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.19-22
    • /
    • 2000
  • ITU-T 국제 표준화 기구에서 인터넷 폰과 화상회의를 목적으로 개발된 G.723.1 음성 부호화기는 잡음 구간에서의 전송률을 낮추기 위한 방법으로 VAD(Voice Activity Detector)와 CNG(Comfortable Noise Generator)를 사용하고 있다. 이중 VAD는 최종적으로 현재 프레임의 에너지 레벨을 비교하여 음성의 활동 유무를 판정하고 있다. 하지만 G.723.1 VAD에서는 보다 안정적인 판정을 위해 음성 활동 구간 사이에 삽입되어 있는 묵음 구간에 대해서는 거의 대부분 음성이 활동하는 영역으로 판정을 하고 있다. 따라서 본 논문에서는 묵음 구간에 대해 보다 정확한 판정을 통하여 기존의 방법에 비해 전송률을 더욱 감소시킬 수 있는 방법을 제안한다. 제안한 방법은 음성신호와 잡음신호의 LSP 파라미터 간격 정보를 이용하여 음성구간을 검출한다. 묵음구간을 길게 조절한 문장을 사용하여 실험한 결과 VAD=1로 판정한 프레임수가 약 $48.98\%$ 감소하였으며 주관적인 음질평가의 경우 음질의 열하는 거의 발생하지 않았다.

  • PDF

Ankle Arthroscopy: Anatomy, Portals and Instrument (발목 관절경: 해부학, 삽입구 및 기구)

  • Sung, Ki-Sun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • Major technologic advances in fiberoptic light transmission, video cameras, and instrumentation have allowed great advances in small-joint arthroscopy. Arthroscopy in particular is now well established procedure for accurate diagnosis and operative management of certain ankle disorders. The small size of the ankle and significant periarticular soft tissue structures make placement and advancement of the arthroscope and instrumentation more difficult than in larger joints. Successful arthroscopy of the ankle requires knowledge of the regional anatomy and a familiarity with the available arthroscopic portals. This review article is going to describe the gross and arthroscopic anatomy of the ankle as it relates to current arthroscopic techniques. Particular emphasis is placed on the anatomic relations of the important osseous and soft tissue structures for a safe, reproducible approach to arthroscopic treatment of ankle pathology. Also, current arthroscopic equipment and instruments are included.