• Title/Summary/Keyword: 삽입결함

Search Result 95, Processing Time 0.026 seconds

Numerical Design of Shielded Encircling Probe for RFEC Testing of Nuclear Fuel Cladding Tube (핵연료 피복재 튜브의 원격장와전류 탐상을 위한 차폐된 관통형 탐촉자의 수치해석적 설계)

  • Shin, Young-Kil;Shin, Sang-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.6
    • /
    • pp.650-657
    • /
    • 2001
  • This paper explains the process of designing a shielded encircling remote field eddy current (RFEC) probe to inspect nuclear fuel cladding tubes and investigates resulting signal characteristics. To force electromagnetic energy from exciter coil to penetrate into the tube, exciter coil is shielded outside by laminations of iron insulated electrically from each other. Effects of shielding and the proper operating frequency are studied by the finite element analysis and the location for sensor coil is decided. However, numerically simulated signals using the designed probe do not clearly show the defect indication when the sensor passes a defect and the other indication appeared as the exciter passes the defect is affected by the shape of shielding structure, which demonstrates that the sensor is directly affected by exciter fields. For this reason, the sensor is also shielded outside and this shielding dramatically improves signal characteristics. Numerical modeling with the finally designed probe shows very similar signal characteristics to those of inner diameter RFEC probe. That is, phase signals show almost equal sensitivity to inner diameter and outer diameter defects and the linear relationship between phase signal strength and defect depth is observed.

  • PDF

A study on the Thermal Buckling and Postbuckling of a Laminated Composite Beam with Embedded SMA Actuators (형상기억합금 선을 삽입한 복합적층 보의 열좌굴 및 좌굴후 거동에 관한 연구)

  • Choi, S.;Lee, J.J.;Lee, D.C.
    • Composites Research
    • /
    • v.12 no.3
    • /
    • pp.55-65
    • /
    • 1999
  • In this paper, the thermal buckling and postbuckling behaviour of composite beam with embedded shape memory alloy (SMA) wires are investigated experimentally and analytically. The results of thermal buckling tests on uniformly heated, clamped, composite beam embedded with SMA wire actuators are presented and discussed in consideration of geometric imperfections, slenderness ratio of beam and embedding position of SMA wire actuators. The shape recovery force can reduce the thermal expansion of composite laminated beam, which result in increment of the critical buckling temperature and reduction of the lateral deflection of postbuckling behaviours. It is presented quantitatively on the temperature-load-deflection behaviour records how the shape recovery force affects the thermal buckling. The cross tangential method is suggested to calculate the critical buckling temperature on the temperature-deflection plot. Based on the experimental analysis, the new formula is also proposed to describe the critical buckling temperature of a laminated composite beam with embedded SMA wire actuators.

  • PDF

Evaluation of Debonding Defects in Railway Concrete Slabs Using Shear Wave Tomography (전단파 토모그래피를 활용한 철도 콘크리트 궤도 슬래브 층분리 결함 평가)

  • Lee, Jin-Wook;Kee, Seong-Hoon;Lee, Kang Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.3
    • /
    • pp.11-20
    • /
    • 2022
  • The main purpose of this study is to investigate the applicability of the shear wave tomography technology as a non-destructive testing method to evaluate the debonding between the track concrete layer (TCL) and the hydraulically stabilized based course (HSB) of concrete slab tracks for the Korea high-speed railway system. A commercially available multi-channel shear wave measurement device (MIRA) is used to evaluate debonding defects in full-scaled mock-up test specimen that was designed and constructed according to the Rheda 200 system. A part of the mock-up specimen includes two artificial debonding defects with a length and a width of 400mm and thicknesses of 5mm and 10mm, respectively. The tomography images obtained by a MIRA on the surface of the concrete specimens are effective for visualizing the debonding defects in concrete. In this study, a simple image processing method is proposed to suppress the noisy signals reflected from the embedded items (reinforcing steel, precast sleeper, insert, etc.) in TCL, which significantly improves the readability of debonding defects in shear wave tomography images. Results show that debonding maps constructed in this study are effective for visualizing the spatial distribution and the depths of the debondiing defects in the railway concrete slab specimen.

A Study on the Characteristics of Microwave Transmission Lines Having Defected Ground Structures and Lumped Elements (결함접지구조와 집중소자를 지닌 초고주파 전송선로의 전기적 특성 연구)

  • Lim Jong-Sik;Bae Ju-Seok;Choi Kwan-Sun;Ahn Dal
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.4
    • /
    • pp.616-624
    • /
    • 2006
  • In this paper, the transfer characteristics of high frequency transmission line having defected ground structure (DGS) and lumped elements are described. When a DGS, which is a kind of periodic structure, is inserted into a transmission line, its equivalent inductance and capacitance elements are added to the characteristics of the standard transmission line. This generates resonance, 3dB cut-off frequency, low-pass, band rejection, and band pass characteristics, and causes a slow-wave and enlarged electrical length of the transmission line. In addition, if the DGS is combined by a lumped element such as resistor, capacitor, and inductor, the resonant and cut-off frequencies moves up or down and other changes occur in the transmission characteristics. The variation of the transmission characteristics is described with the qualitative prediction and measured data.

  • PDF

Prussian Blue Analogues for Rechargeable Batteries (프러시안블루 유사체를 활용한 이차전지 연구)

  • Kim, Yang Moon;Choi, Seungyeon;Choi, Jang Wook
    • Journal of the Korean Electrochemical Society
    • /
    • v.22 no.1
    • /
    • pp.13-21
    • /
    • 2019
  • Prussian blue analogues(PBAs) are comprised of cyano-bridged transition metal ions. The wide and unique open-framework structures of the PBAs enable reversible intercalation and deintercalation of various ions such as $Na^+$, $K^+$, $Mg^{2+}$, $Zn^{2+}$, etc. In addition, since PBAs are synthesized through coprecipitation reaction in aqueous solution at room temperature, they are produced economically and environmentally friendly. However, the formation of crystals proceeds rapidly, and defects such as vacancy and crystal water tend to be present in the crystals, thereby affecting key battery performance. Therefore, significant efforts to inhibit defects in PBAs have been made. In the case of vacancy, the reaction rate was controlled at the synthesis stage to reduce the formation of vacancy, and the crystal water was removed by heat treatment under vacuum. In addition, by adding transition metals that do not react within the structure of PBA, the structural instability during the electrochemical reaction was largely alleviated.

InAs 양자점의 AlxGax-1As 장벽층 구조에 따른 광학적 특성

  • Han, Im-Sik;Lee, Sang-Jo;Jo, Hyeon-Jun;Bae, In-Ho;Kim, Jong-Su;Kim, Yeong-Ho;Kim, Seong-Jun;Kim, Jun-O;Lee, Sang-Jun;No, Sam-Gyu;Park, Dong-U;Kim, Jin-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.235-235
    • /
    • 2010
  • 본 연구에서는 태양전지의 활성영역에 삽입할 InAs 양자점에 AlxGax-1As 장벽층을 삽입하여 그 두께변화에 따른 광학적 특성 변화를 photoreflectance spectroscopy (PR)과 photoluminescence (PL)를 이용하여 연구하였다. 본 연구에 사용된 InAs/AlGaAs 양자점 구조는 GaAs (100) 기판 위에 GaAs buffer layer를 500 nm 성장 ($Ts=580^{\circ}C$) 후 기판온도 $470^{\circ}C$에서 InAs 양자점, GaAs cap 층과 AlxGax-1As 장벽층 순서로 5 층의 InAs/GaAs/AlxGax-1As 양자점 구조를 형성하였다. GaAs cap 층의 두께는 4 nm로 고정하고 AlGaAs 장벽층 두께를 0~6 nm 까지 변화시켰다. 각 양자점 층 사이에 AlxGax-1As 장벽층의 삽입 유무에 따라 PR 신호에서 Franz-Keldysh oscillation (FKO)의 주기 변화가 관측되었다. AlGaAs 두께가 증가 할수록 PL 신호의 세기가 증가함을 보였으며 PL 신호의 온도의존 특성이 변화됨을 관측할 수 있었다. AlGaAs 장벽층 대신 AlAs 장벽층을 삽입한 시료에서도 유사한 경향성을 관측하였으며, 이는 양자점에 구속된 운반자의 터널링 현상과 높은 장벽층에 의한 운반자의 구속 강도의 변화에 의한 것으로 사료된다. 특히 장벽층의 유무에 따른 FKO의 변화는 시료의 표면 전기장의 변화에 기인한 것으로 운반자의 구속효과뿐만 아니라 InAs 양자점 성장중 형성된 표면결함 밀도의 변화에 의한 것으로 추정하였다.

  • PDF

Minimizing Design of the Schiffman Phase Shifter Using the Defected Ground Structure (결함접지면을 이용한 쉬프만 위상 천이기의 소형화)

  • Kim, Gi-Rae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.9
    • /
    • pp.1745-1752
    • /
    • 2009
  • This Paper represents a new method, which uses defected ground structure (DGS) on the ground planes of microstrip lines, to reduce the size of the Schiffman phase shifter. DGS on the microstrip line shows an increased slow-wave effect due to the additional equivalent L and C components. So the electrical length of transmission line with DGS is longer than that of standard transmission line for the same physical length. Then, the length of transmission line with DGS can be shortened in order to maintain the original electrical length to be same. The performances of reduced phase shifter with DGS are quite similar to the ones of original Schiffman phase shifters. We can reduce the size about 15% using the DGS in original Schiffman phase shifter.

Design of Small-Size High-Power SPDT PIN Diode Switch with Defected Ground Structure for Wireless Broadband Internet Application (결함접지구조(Defected Ground Structure)를 갖는 휴대 인터넷용 소형 고전력 SPDT PIN 다이오드 스위치 설계)

  • Kim Dong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.10 s.101
    • /
    • pp.1003-1009
    • /
    • 2005
  • In this paper, small-size high-power single pole double throw(SPDT) switch with defected pound structure(DGS) is presented for wireless broadband internet application. To reduce the circuit size using slow-wave characteristic, the DGS is applied to ${\lambda}/4$ transmission line of the switch and the measured results are compared with them of conventional switch. To secure high degree of isolation, the switch with the DGS is composed of shunt-connected PIN diodes and shows insertion loss of 0.8 dB and isolation more than 50 dB at 2.3 GHz. The size of the switch is reduced about $50\%$ only with the DGS patterns while it has very similar performance to the conventional shunt-type switch.

Microstructures of Multi-layer Ce-TZP/Ce-TZP-$Al_2$$O_3$Composites (Ce-TZP/Ce-TZP-$Al_2$$O_3$다층구조 복합체의 미세구조)

  • 황규홍;백인찬;이종국
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.5
    • /
    • pp.418-423
    • /
    • 2001
  • 16 mole%의 CeO$_2$가 고용된 Ce-TZP 소결체 사이에 140~240$mu extrm{m}$ 두께의 Ce-TZP-5~30 vol% $Al_2$O$_3$중간층이 삽입된 층상복합체를 분말건식가압성형법에 의해 제조하였다. 소결온도는 $Al_2$O$_3$가 5~30 vol.% 첨가될 때 90% 이상의 소결밀도를 얻을 수 있도록 1$600^{\circ}C$로 정하였다. 이러한 3층 복합체에서 바깥의 Ce-TZP 지역에서의 파괴 형태는 입내파괴를 보여주었지만 $Al_2$O$_3$가 함유된 중간층에서는 입계파괴가 전이되면서 인성증가를 보여주었다. 이러한 층상 복합체의 경우 중간 층에 들어가는 Ce-TZP 중의 $Al_2$O$_3$함량이 30 vol.% 정도에 이르면 층간의 서로 다른 소결밀도 및 수축율, 열팽창계수 때문에 층간 소결 결함이 생겨 층간에서 균열의 전파가 큰 영향을 받음을 알 수 있었다. 반면 중간층의 $Al_2$O$_3$함량이 적을 경우 층간 결함이 생기지 않아 층간에서 균열의 전파가 별 영향을 받지 않음을 알 수 있었다.

  • PDF

The Analysis of Partial Discharges Pattern using Discrete Wavelet Transform (이산 웨이브렛변환에 의한 부분방전패턴 분석)

  • 이현동;이광식;이동인
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.1
    • /
    • pp.84-89
    • /
    • 2001
  • This paper deals with multiresolution analysis of wavelet transform for partial discharge(PD), composite discharge(corona + surlace discharge). Multiresolution analysis was used for performing discrete wavelet transform PD signals was decomposed into "approximation" and "detail" cOmpJnents until 4 levels by using discrete wavelet analysis. In this paper, daubechies family is adopted for the research of the characteristics of PD signals. 1be results show that in corona discharge the segment 7, 8, 9, 10, 1] values of defined variable is increased with discharge process, so phase distribution is characterized by 210~330 ranges. In case surface discharge in expoxy insulator inserted, defined variable values is fairly symmetric chscharge pattern because coupled both corona and dielectric oounded discharges. We can confimJly discriminate the type of PD source.

  • PDF