• Title/Summary/Keyword: 삼차원 접촉

Search Result 31, Processing Time 0.021 seconds

Noncontact Type Three Dimensional Profile Measurement for CAD Modeling of Sculptured Surface (자유곡면의 CAD 모델링을 위한 비접촉식 삼차원 형상측정)

  • Park, H.G.;Park, Y.B.;Kim, S.W.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.1
    • /
    • pp.5-14
    • /
    • 1995
  • An optical measurement method of three dimensional surface profiles which is named the slit beam projection is suggested and practically implemented. This method is intended especially for noncontact and fast digitization of sculptured surfaces for CAD modeling and die manufacturing. Its basic principles are based on geometric optics. Deatiled optical principles and an sub-pixel image processing technique to enhance the measuring resolutions are described in this study. The measuring performances of the slit beam projection are presented and discussed to demonstrate that an actual measuring accuracy of below .+-. 0.2mm can be achived over the whole measuring range(500mm*300mm*200mm)

  • PDF

Computational Efficiency of 3-D Contact Analysis by Domain/Boundary Decomposition Formulation (영역/경계 분할 정식화에 의한 삼차원 접촉 해석의 효율성 검토)

  • Shin, Eui-Sup;Kim, Yong-Uhn;Ryu, Han-Yeol
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.471-474
    • /
    • 2007
  • A domain/boundary decomposition technique is applied to carry out efficient finite element analyses of 3-D contact problems. Appropriate penalty functions are selected for connecting an interface and contact interfaces with neighboring subdomains that satisfy continuity constraints. As a consequence, all the effective stiffness matrices have positive definiteness, and computational efficiency can be improved to a considerable degree. If necessary, any complex-shaped 3-D domain can be divided into several simple-shaped subdomains without considering the conformity of meshes along the interface. With a set of numerical examples, the basic characteristics of computational efficiency are investigated carefully.

  • PDF

Precision Profile Measurement of Mirror Surfaces by Phase Shifting Interferometry (광위상간섭에 의한 경면의 정밀 형상측정)

  • 김승우;공인복;민선규
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.8
    • /
    • pp.1530-1535
    • /
    • 1992
  • An optical method of phase shifting interferometry is presented for the 3-dimensional profile measurement of mirror surfaces with nanometer resolution. A series of optical interferometric fringes are generated by comparing the surface to be measured with a reference flat. The fringes are captured by a CCD camera and then analyzed to obtain actual surface profile. Detailed principles are described along with necessary image processing algorithms. finally, several measurement examples are discussed which were performed on lapped surfaces, hard discs, and semiconductor wafers.

A Study on Eulerian Analysis for the Steady State Rolling (정상상태 압연공정의 오일러리안 해석에 관한 연구)

  • 이용신
    • Transactions of Materials Processing
    • /
    • v.13 no.7
    • /
    • pp.570-579
    • /
    • 2004
  • 정상상태 압연공정의 오일러리안 공정해석 모델에 관한 연구들을 종합 정리하였다 본 연구의 유한요소해석 모델은 집합조직의 발전에 따른 이방성과 미세기공의 성장에 따른 기계적 성질의 열성화를 평형방정식에 직접 결합하였다 따라서 집합조직의 발전 및 기공률의 변화를 예측하고 동시에 이방성과 기계적성질의 열성화를 해석에 반영할 수 있다. 더불어 오일러리안 해석에서 형상예측을 위하여 자유곡면 수정법과 유선추적법을 유한요소해석 모델에 결합하였다 본 연구의 공정해석 모델을 평판 압연, 클래드압연, 삼차원 사각단면봉의 압연 및 형상압연에 적용하여 집합 조기의 발전, R-값, 항복곡면, 결함성장 등의 기계적성질의 변화 예측과 클래드 압연시에 이중재 접촉면 형상, 배불림, 형상압연 시의 단면변화 등의 형상변화 예측을 보여주었다.

Calibration of Optical Dimensional Measurement System Using Optical Microscope (광학현미경을 이용한 비접촉식 치수측정시스템의 교정)

  • Park, Hyun-Goo;Park, Min-Cheol;Kim, Seung-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.11
    • /
    • pp.118-125
    • /
    • 1997
  • Non-contacting optical microscopes are increasingly used in recent industrial applications of probes for coordinate measuring machines. They have been found more efficient than conventional touch trigger porbes with ball tips especially in inspecting small-sized objects. There are two major factors affecting measuring accuracy: (1) geometric relations between coordinate systems, (2) magnification ratios of a microscope. In order to determine the magnification ratios exactly, optical imaging of edge was theroretically analyzed and practically adopted to image processing for edge detection. In addition, this paper proposes a geometric calibration method to obtain exact coordinates of measured points from the relations between the machine coordinate system and the image. In the method, the error according to the squareness between the machine axises was also removed. The method was practically adopted to a real coordinate measuring machine. An ultraprecision measurement of 0.2 um uncertainty can be practically achieved.

  • PDF

An Efficient Algorithm for 3-D Range Measurement using Disparity of Stereoscopic Camera (스테레오 카메라의 양안 시차를 이용한 거리 계측의 고속 연산 알고리즘)

  • 김재한
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.6
    • /
    • pp.1163-1168
    • /
    • 2001
  • The ranging systems measure range data in three-dimensional coordinate from target surface. These non-contact remote ranging systems is widely used in various automation applications, including military equipment, construction field, navigation, inspection, assembly, and robot vision. The active ranging systems using time of flight technique or light pattern illumination technique are complex and expensive, the passive systems based on stereo or focusing principle are time-consuming. The proposed algorithm, that is based on cross correlation of projection profile of vertical edge, provides advantages of fast and simple operation in the range acquisition. The results of experiment show the effectiveness of the proposed algorithm.

  • PDF

A New Method of Noncontact Measurement for 3D Microtopography in Semiconductor Wafer Implementing a New Optical Probe based on the Precision Defocus Measurement (비초점 정밀 계측 방식에 의한 새로운 광학 프로브를 이용한 반도체 웨이퍼의 삼차원 미소형상 측정 기술)

  • 박희재;안우정
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.1
    • /
    • pp.129-137
    • /
    • 2000
  • In this paper, a new method of noncontact measurement has been developed for a 3 dimensional topography in semiconductor wafer, implementing a new optical probe based on the precision defocus measurement. The developed technique consists of the new optical probe, precision stages, and the measurement/control system. The basic principle of the technique is to use the reflected slit beam from the specimen surface, and to measure the deviation of the specimen surface. The defocusing distance can be measured by the reflected slit beam, where the defocused image is measured by the proposed optical probe, giving very high resolution. The distance measuring formula has been proposed for the developed probe, using the laws of geometric optics. The precision calibration technique has been applied, giving about 10 nanometer resolution and 72 nanometer of four sigma uncertainty. In order to quantitize the micro pattern in the specimen surface, some efficient analysis algorithms have been developed to analyse the 3D topography pattern and some parameters of the surface. The developed system has been successfully applied to measure the wafer surface, demonstrating the line scanning feature and excellent 3 dimensional measurement capability.

  • PDF

Effect of bone-implant contact pattern on bone strain distribution: finite element method study (골-임플란트 접촉 양상에 따른 골 변형 연구: 유한요소법적 연구)

  • Yoo, Dong-Ki;Kim, Seong-Kyun;Koak, Jai-Young;Kim, Jin-Heum;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.214-221
    • /
    • 2011
  • Purpose: To date most of finite element analysis assumed the presence of 100% contact between bone and implant, which is inconsistent with clinical reality. In human retrieval study bone-implant contact (BIC) ratio ranged from 20 to 80%. The objective of this study was to explore the influence of bone-implant contact pattern on bone of the interface using nonlinear 3-dimensional finite element analysis. Materials and methods: A computer tomography-based finite element models with two types of implant (Mark III Br${\aa}$nemark$^{(R)}$, Inplant$^{(R)}$) which placed in the maxillary 2nd premolar area were constructed. Two different degrees of bone-implant contact ratio (40, 70%) each implant design were simulated. 5 finite element models were constructed each bone-implant contact ratio and implant design, and sum of models was 40. The position of bone-implant contact was determined according to random shuffle method. Elements of bone-implant contact in group W (wholly randomized osseointegration) was randomly selected in terms of total implant length including cortical and cancellous bone, while ones in group S (segmentally randomized osseointegration) was randomly selected each 0.75 mm vertically and horizontally. Results: Maximum von Mises strain between group W and group S was not significantly different regardless of bone-implant contact ratio and implant design (P=.939). Peak von Mises strain of 40% BIC was significantly lower than one of 70% BIC (P=.007). There was no significant difference between Mark III Br${\aa}$nemark$^{(R)}$ and Inplant$^{(R)}$ in 40% BIC, while average of peak von Mises strain for Inplant$^{(R)}$ was significantly lower ($4886{\pm}1034\;{\mu}m/m$) compared with MK III Br${\aa}$nemark$^{(R)}$ ($7134{\pm}1232\;{\mu}m/m$) in BIC 70% (P<.0001). Conclusion: Assuming bone-implant contact in finite element method, whether the contact elements in bone were wholly randomly or segmentally randomly selected using random shuffle method, both methods could be effective to be no significant difference regardless of sample size.

Three-dimensional finite element analysis according to the insertion depth of an immediately loaded implant in the anterior maxilla (상악 전치부 즉시하중 임플란트의 식립 깊이에 따른 삼차원 유한요소 분석)

  • Park, Cheol-Woo;Kim, Sung-Hun;Yeo, In-Sung;Yoon, Hyung-In;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.105-113
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the effects of the insertion depth of an immediately loaded implant on the stress distribution of the surrounding bone and the micromovement of the implant using the three-dimensional finite element analysis. Materials and methods: A total of five bone models were constructed such that the implant platform was positioned at the levels of 0.00 mm, 0.25 mm, 0.50 mm, 0.75 mm, and 1.00 mm depth from the crest of the cortical bone. A frictional coefficient of 0.3 and the insertion torque of 35 Ncm were simulated on the interface between the implant and surrounding bone. A static load of 178 N was applied to the provisional prosthesis with a vertical load in the axial direction and an oblique load at $30^{\circ}$ with respect to the central axis of the implant, then a finite element analysis was performed. Results: The implant insertion depth significantly affected the stress distribution on the surrounding bone. The largest micromovement value of the implant was $39.34{\mu}m$. The oblique load contributed significantly to the stress distribution and micromovement in comparison to the vertical load. Conclusion: Increasing the implant insertion depth was advantageous in dispersing the concentrated stress in the cortical bone and did not significantly affect the micromovement associated with early osseointegration failure.

A three-dimensional finite element analysis of osseointegrated implant on stress distribution in different abutment designs and fixture diameters (각종 지대주 및 고정체 종류에 따른 골유착성 임플랜트의 응력 분포에 관한 삼차원 유한요소분석적 연구)

  • Kwon, Ho-Beom;Kim, Chang-Whe;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.4
    • /
    • pp.699-721
    • /
    • 1996
  • 브로네마르크가 골유착성 임플랜트를 소개한 이래로, 현재 골유착성 임플랜트에 의한 치료는 안전하고 안정적인 방법으로 여겨지고 있다. 골유착성 임플랜트를 이용한 초기의 치료는 무치악 환자의 저작기능 회복에 중점을 두어 왔다. 그러나 현재는 환자와 시대의 요구에 따라서 심미성이 주요한 관심사가 되었다. 그래서 표준 지대주보다 더 심미적인 지대주 시스템들이 개발되었다. 다양한 직경의 임플랜트 고정체에 관한 임상가들의 요구에 의해 직경 이 큰 고정체가 생산되기 시작했으며, 5mm의 직경을 갖는 고정체가 그 예이다. 골유착성 임플랜트를 사용하여 보철치료를 할 때, 골과 고정체의 계면은 보철물과 지대주에 가해지는 교합력을 인접골에 전달하게 되며, 이것은 계면에 생물학적인 반응을 야기할 수 있다. 임플랜트의 형태는 골흡수와 같은 바람직하지 않은 반응을 일으키지 않도록 고안되어야 하며, 임플랜트 자체가 교합력을 견딜 수 있어야 한다. 그러므로 골유착성 임플랜트 시스템을 임상에 사용하려고 할 때 이것의 생역학적 분석은 반드시 필요하다. 본 연구에서는 삼차원 유한요소분석적 방법을 사용하여 3.75mm직경을 갖는 고정체에 표준 지대주, 이세티콘 지대주, 마이러스콘 지대주를 연결한 모델과 5mm 직경을 갖는 고정체에 표준 지대주를 연결한 모델에 각각 수직하중, 경사하중, 수평하중을 가했을 때의 응력분포를 비교하였다. 본 연구의 결과는 다음과 같다. 1. 모든 모델에서 금나사의 경부, 금원주, 지대주에 응력의 집중이 일어났다. 2. 임플랜트 고정체에서는 고정체 상방 2/3, 그리고 지대주와 접촉하는 고정체 상면에서 응력의 집중이 관찰되었다. 3. 골에서는 상부 피질골에 응력의 집중이 관찰되었으며, 해면골에서는 두드러진 응력의 집중을 보인 부위는 없었으나 고정체의 근단부 주위 해면골에서의 응력값이 비교적 높았다. 4. 5mm 직경의 고정체를 사용하지 않은 모델 중에서, 표준 지대주를 사용한 경우가 가장 응력분산에 유리하였으며 마이러스콘 지대주를 사용한 경우가 가장 불리하였다. 5. 3가지 하중 조건하에서 수평하중과 경사하중의 경우가 수직하중의 경우보다 더 높은 응력값이 관찰되었다. 6. 응력값은 골에서보다 임플랜트 내부에서 훨씬 높았다.

  • PDF