• 제목/요약/키워드: 삼각덕트

검색결과 4건 처리시간 0.031초

한 측에서만 거칠기가 설치된 삼각덕트의 마찰계수와 열전달 (Heat Transfer and Pressure Drop Characteristics of Triangular Ducts with One Side Rib-Roughened)

  • 안수환;이영석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권2호
    • /
    • pp.17-23
    • /
    • 2000
  • Experimental investigations were conducted to study the forced convection of fully-developed turbulent flow in horizontal equilateral duct fabricated with the same length and equivalent diameter, but different surface roughness pitch ratio(P/e) of 4, 8 and 16 on the one side wall only. The experiments were performed with the hydraulic diameter based Reynolds number ranged from 70,000 to 10,000. The entire bottom wall of the duct was heated uniformly and the other surfaces were thermally insulated. To understand the mechanisms of the heat transfer enhancement, measurements of the heat transfer were done to investigate the contributive factor of heat transfer promotion, namely, the fin effect. And the results were compared with those of previous investigations for similarly configured channels, at which they were roughened by regularly spaced transverse ribs in the rectangular and circular channels.

  • PDF

한 측에서만 거칠기가 설치된 삼각덕트의 열전달과 압력강하 특성 (Heat Transfer and Pressure Drop Characteristics of Triangular Ducts with One Side Rib-Roughened)

  • 안수환;이영식;이병창
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.65-70
    • /
    • 2000
  • Experimental investigations were conducted to study the forced convection of fully-developed turbulent f)on· in horizontal equilateral duct fabricated with the same length and equivalent diameter, but different surface roughness Pitch ratio(P/e) of 4, 8 and 16 on the one side wall only The experiments were performed with the hydraulic diameter based Reynolds number ranged from 70.000 to 10,000 The entire bottom wall of the duct was heated uniformly and the other surfaces were thermally insulated. To understand the mechanisms of the heat transfer enhancement. measurements of the heat transfer were done to investigate the contributive factor of heat transfer promotion. namely the fin effect. And the results were compared with those of Previous investigations for similarly configured channels, at which they were roughened by regularly spaced transverse ribs in the rectangular and circular channels.

  • PDF

와동 플랩 삼각날개를 이용한 관내 와류 발생장치 설계 및 수치해석 (Design and Numerical Analysis of Swirl Generator in Internal Duct using Delta Wing with Vortex Flap)

  • 김명호
    • 한국항공우주학회지
    • /
    • 제35권9호
    • /
    • pp.761-770
    • /
    • 2007
  • 본 연구에서는 압력 왜곡과 유동각 왜곡을 모사하기 위하여 삼각날개를 이용한 와류 발생장치를 설계하였다. 삼각날개는 목표한 와류코어 위치와 압력왜곡율(DC90), 와류각을 만족하기 위해 후퇴각 $65^{\circ}$를 사용하였으며, 와류의 분포 영역을 넓히기 위해 삼각날개 전단면에 $45^{\circ}$ 와동 플랩을 적용하였다. 제작된 와류 발생장치는 시뮬레이션 덕트를 적용한 유동 왜곡 시험에서 전압력 왜곡율의 설계 요구조건을 만족하였으며, 시험 결과로부터 검증된 전산유체해석 결과를 이용하여 와류코어 위치와 와류각의 목표 성능을 확인하였다.

왕복운동을 하는 사각채널에서 파형테이퍼가 열전달에 미치는 효과 (Effects of Wavy Tapers on Heat Transfer in the Reciprocating Rectangular Channel)

  • 안수환;배성택
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권5호
    • /
    • pp.600-608
    • /
    • 2003
  • This Paper describes a detailed experimental investigation of heat transfer in a reciprocating smooth rectangular duct having only the bottom wall heated with reference to the design of a piston for a marine propulsive diesel engine The Parametric test matrix involves Reynolds number and reciprocating radius, respectively, in the range of 1.280∼4.100, and 7∼15 cm with five different reciprocating frequency tested. namely. 1.7, 2.2, and 2.6 Hz. The effects of three different hemi-triangular wavy type tapers on the heat transfer in the reciprocating rectangular channel using the air as a working fluid were check out. The present work confirms that the Nusselt number in the channel with the triangular wavy type taper is lower than without the triangular wavy type taper.