• Title/Summary/Keyword: 산업폐열

Search Result 68, Processing Time 0.028 seconds

An Assessment of the Alternative Selection of Energy System using AHP (AHP를 이용한 에너지시스템 대안 선정 평가)

  • Lee, Deok Ki;Park, Soo Uk;Yang, Jong Tack;Gim, Bong Jin
    • Environmental and Resource Economics Review
    • /
    • v.12 no.4
    • /
    • pp.611-635
    • /
    • 2003
  • This study deals with the "Dissemination Stage", the final step in the R&D process consisting of R&DDD($R&D^3$ : Research & Development, Demonstration, Dissemination). At the "Dissemination Stage", the newly configured technical design is compared with other alternatives to come up with the most desirable selection. The assessment conducted at this stage is not a simple procedure. It goes through the complex evaluation process in which various elements including economic effects and technical characteristics are considered. The reason for taking such a complex procedure is that the assessment, selection and application of the desirable technical alternative is critical for the company's competitive edge in every field of industrial sectors, thus influencing its survival and continuous growth. This study reviews the AHP method for assessing technical alternatives of the heat supply system design. And, to show the practical validity of the AHP method, it is applied to the evaluation of waste heat system alternatives in the field of energy supply system technology.

  • PDF

The Effect of Mass Transfer on the Cure Properties of the Urea Resin Moulding Compounds Under the Drying Process (건조 공정 중 요소 수지 성형재료의 경화 특성에 대한 물질전달 효과)

  • Kim, Sang Yeul;Choi, Il Gon;Kim, Byoung Chul
    • Korean Chemical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.681-686
    • /
    • 2002
  • In the industrial field, the theory of drying process is different from the practical application, and it is effective to reduce energy by recirculation of the heat of exhausting gas. But the study of this field may not be performed still. The cure properties of the urea resin moulding compounds was investigated according to drying temperature, drying time, recycle rate of exhausting gas and moulding temperature in the process of drying and moulding. We obtained the following results; water content of material decreases with increasing drying time and drying temperature, and the rate of drying also decreases with increasing recycle rate of exhausting gas. Specially, The cure fluidity of the urea resin moulding compounds decreases, with increasing drying temperature, recycle rate of exhausting gas and moulding temperature. And the correlation equations on water content and cure fluidity of the urea resin moulding material were obtained through a regression analysis of experimental data.

Fabrication of Thermoelectric Module and Analysis of its Power Generation Characteristics (열전발전소자 제작 및 발전특성 분석)

  • Choi, Taeho;Kim, Tae Young
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.2
    • /
    • pp.90-97
    • /
    • 2021
  • In this study, a Bi2Te3 thermoelectric generator (TEG) was fabricated to convert unused thermal energy into useful electrical energy. For the performance test, a dedicated experiment device consisting of a heating block operating with cartridge heaters and a cooling block through which a refrigerant flows was constructed. A 3×3 array of thermocouples was mounted on the heating block and the cooling block, respectively, to derive the temperature fields and heat transfer rate onto both sides of the TEG. Experiments were conducted for a total of 9 temperature differences, obtaining V-I and P-R curves. The results of 7 variables including Seebeck coefficients that have a major effect on performance were presented as a function of the temperature difference. The feasibility of the energy recovery performance of the developed TEG was verified from the maximum power output of 7.5W and conversion efficiency of 11.3%.

Effects of Construction and Operation of Nuclear Power Plants on Benthic Marine Algae (원자력발전소의 건설과 가동이 저서 해조류에 미치는 영향)

  • 김영환
    • Korean Journal of Environmental Biology
    • /
    • v.17 no.4
    • /
    • pp.379-387
    • /
    • 1999
  • During the past several decades, electricity generating plant increased with remarkable rapidity in Korea. Recently the increase has been much more rapid as the rate of industrialization has accelerated. Construction of nuclear power plants in coastal areas inevitably caused the perturbation of critical coastal habitats and thus influenced marine algal species composition. Particularly, an increase in the building of nuclear power plants led the amounts of heat discharged to increase exponentially. As far as the effects of cooling water and thermal discharges are concerned, benthic marine algae are likely to be vulnerable to a discharge. Heated effluents from nuclear power plants, with the temperature rises of 7~12$^{\circ}C$ under normal operating and design conditions, are discharged through the discharge canal and into natural water bodies. It is clear that the characteristic marine algal community is developed in the area affected by the thermal discharges; i.e. low species richness and low species diversity. Nevertheless, it is worthwhile to note that elevated temperatures exert differential effects depending on the algal populations. Benthic marine algae grown at the discharge canal can be regarded as warm tolerant species. 35 species (4 blue-green, 9 green, 8 brown and 14 red algae) of marine algae occurred more than 20eye frequency at discharge canal of three nuclear power plants in the east coast during 1992 ~ 1998 and thus can be categorized as warm tolerant species in Korea. To minimize the ecological impacts of waste heat on benthic marine algae, it is recommended that, in the future, nuclear power plants will have to employ some form of closed-cycle cooling for the condensers.

  • PDF

A study on the risk and settlement evaluation of a shield TBM excavated in soft marine sedimentary soils (해저 연약 퇴적층 지반 쉴드 TBM 위험요인 평가 및 장비 침하에 관한 연구)

  • You, Kwang-Ho;Park, Chi-Myeon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.4
    • /
    • pp.355-364
    • /
    • 2016
  • Recently, a 3,250 meter-long tunnel was constructed beneath the sea bed formed of composite sedimentary soils to transport reusable waste heat gas of industrial complex in the west coast of Korea. Some risks such as machine settlement always exist due to the uncertainties of geological and construction factors during the subsea shield TBM tunnelling. In this construction site, the deviation of tunnel alignment caused by shield TBM settlement was occurred during excavation. It was examined that the lack of bearing capacity of soft clay was a main cause. This paper evaluates the risk of shield TBM tunnelling considering the ground conditions. Correlation between machine settlement and its advance rate was evaluated through the analytical equation in which bearing capacity is considered and a 3-D numerical analysis which can simulate the TBM advance condition (in other words, the dynamic condition). It was found out that a shield TBM could settle due to the insufficient bearing capacity of soft clay layers. In order to prevent such the problem, the best advance rate proper to the ground characteristics is needed to be applied. In the ground conditions of the section of interest, it was turned out that if the shield TBM advance rate was maintained between 35 mm/min and 40 mm/min, the machine settlement could be avoided.

곶감의 고품질화 기술개발

  • 오상룡
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2002.04a
    • /
    • pp.41-47
    • /
    • 2002
  • 감 과실(Diospyros kaki folium)은 아열대로부터 온대에 이르는 넓은 지역에서 재배되고 우리나라에서는 고래로부터 중요한 과실의 하나이다. 감은 예로부터 화상, 동상, 해독 및 지혈 등의 치료에 널리 이용되어져 왔으며 특히 곶감꼭지는 시체(枾滯)라 하여 달여서 먹으면 딸꾹질을 멎게 하는데 특효가 있다고 알려져 있다. $\ulcorner$본초비효$\lrcorner$ 에서는 생감을 깍아 말린 곶감은 숙혈을 없애고, 폐열, 혈토, 구역질, 장풍과 치질을 다스리는데 쓰인다고 하였다. 또한 감은 비타민 C의 함량이 많아 감을 먹으면 감기 예방에 좋다고 알려져 왔으며 주로 생식용으로 이용되어져 왔으나 최근 감을 이용한 다양한 가공제품 및 새로운 기능성 식품의 개발을 위한 연구가 활발히 이루어지고 있다. 감의 국내 총 생산량의 약60% 이상이 영남 지방에서 집중되어 재배 생산되고 잇으며 감과실의 비중은 다른 어느 지방보다 크다고 하겠다. 감은 단감과 떫은감이 있는데 단감은 주로 생과로 이용되고 있으며 떫은감은 떫은 맛을 가지기 때문에 생과로서 이용하는데 어려움이 있다. 상주는 백미, 누애고치, 곶감 등 희게 보이는 특산물이 유명한 삼백(三白)의 고장으로 미곡 생산량 전국 9위, 떫은감 2위, 곶감은 저눅 1위, 배는 2위, 사과 5위, 포도 4위를 점유하는 농업의 비중이 매우 높은 지역으로 농산물 시장 개방 확대와 과잉생산에 따른 가격하락의 피해를 예상된다. 종래 곶감의 위생적 문제점을 보완하고 공장 규모로 생산된, 품질이 규격화되고 유통기한이 설정된 고품질 전통 곶감의 제조 및 이에 따른 기술개발이 시급히 요구된다.idin C-1-3'-3" -3/'S _0-trigallate 즉, gallate가 붙은 호합물에서100rM의 농도에서 66%와 63%의 강한 저해효과를 나타났다. Tyrosinase 저해활성을 측정한 결과는pocyanidin C-1-3'-3" -3.'S _0-trigallate는 100rM에서 70%의 강한 저해효과를 나타냈으며,epigallocatechin-(4$\beta$$\longrightarrow$8)-epigallo-catechin-(4$\beta$$\longrightarrow$8)-catechin는 51%의 저해효과를 나타내었다. 산업적응용을 위해 분획한 폴리페놀군은 미백효과 검증실험인 tyrosinase 저해율 측정평가에서 폴리페놀 함량이 가장 높은 Fraction 111의 경우 Sooppm에서 74.2%의 높은 저해율을 나타내었다. 항산화력 실험에서는500pw1이상에서 강한 활성능을 보인 SOD 유사활성능을 제외한 나머지 DPPH와 xanthine oxidase 저해효과에서는 Fraction II와III 모두가50ppm이상에서 80% 이상의 높은 유리라디칼 소거능력을 나타내었다. 그리고 각 Fraction별 항균력 측정 결과 Fraction 르와 111이 우수하게 나타났고 항균활성은 그람음성균보다 그람양성균에서 효과적이었으며, 농도별 항균력시험 결과 농도가 증가할수록 비례하여 저해율도 증가함을 알 수 있었다. 첨가농도를 달리하여 미생물의 생육도를 측정한 결과, fraction II磎꼭\ulcorner경우 그람양성균에 대해 500 ppm 이상에서 뚜렷한 증식억제효과를 나타내었다.

  • PDF

Study on the control technique for the heat transportation system using metal hydride (수소저장합금을 이용한 열수송시스템 제어기술 연구)

  • Sim, K.S.;Kim, J.W.;Kim, J.D.;Myung, K.S.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.11 no.1
    • /
    • pp.43-49
    • /
    • 2000
  • The heat transportation from a complex of industry to a rural area needs more efficient method because the distance between them is usually more than 10km. Conventional heat transportation using steam or hot water via pipe line has limits in transportation distance (about 3~5 km) because of the heat loss and frictional loss in the pipe line. Metal hydride can absorb or discharge hydrogen through exothermic or endothermic reaction. After releasing hydrogen from metal hydride by means of the waste heat from industry, we can transport this hydrogen to urban area via pipe line. In urban areas, other metal alloy reacts with this hydrogen to form metal hydride and produces heat for heating. Cool heat is also obtained if it is possible to use metal hydride with low reaction temperature. Therefore, metal hydride can be used as a media for transportation and storage of heat. $MmNi_{4.5}Al_{0.5}Zr_{0.003}$, $LaNi_5$, $Zr_{0.9}Ti_{0.1}Cr_{0.6}Fe_{1.4}$, $MmNi_{4.7}Al_{0.1}Fe_{0.1}V_{0.1}$ alloys were selected for this purpose and the properties of those metal hydrides were discussed. The design and control techniques were proposed and discussed for this heat transportation system using metal hydride.

  • PDF

Development of High Efficiency Dehumidifiers in low temperature (저온에서 고효율 제습기 개발)

  • Kim, Jong-Ryeol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.206-211
    • /
    • 2016
  • Various applications require dry air at low temperature, such automation equipment, semiconductor manufacturing, chemical production lines, and coating processes for the shipbuilding industry. Four evaporators for low temperature (below $0^{\circ}C$) were installed for a dehumidification system. Moist air is cooled sequentially over three evaporators. The first evaporator has an evaporation temperature of $13^{\circ}C$, that of the second evaporator is $5^{\circ}C$, and that of the third evaporator is maintained at $-1.3^{\circ}C$. In the fourth evaporator implantation thereby the moisture contained in the moisture air. A pressure regulator (CPCE 12) is used at this point and is defrosted when the vapor pressure is below a set value. The non-implantation moisture of the air is a heating system that uses the waste heat of a condenser with high temperature. It develops the cooling type's dehumidifier, which is important equipment that prevents the destruction of protein and measures the temperature and humidity at each interval by changing the front air velocity from 1.0 m/s to 4.0 m/s. The cooling capacity was also calculated. The greatest cooling capacity was 1.77 kcal/h for a front air velocity of 2.0 m/s