• Title/Summary/Keyword: 산업용 보일러

Search Result 75, Processing Time 0.02 seconds

산업용 보일러 연료전환에 따른 효율 향상 적용사례

  • 유현석;이현찬;이중성
    • Environmental engineer
    • /
    • s.175
    • /
    • pp.70-75
    • /
    • 2001
  • 산업용 보일러에 대해 오일버노에서 가스버너로 설비교체를 하면서 폐열회수, 저공기비 운전 등을 통해 열효율이 6$\~$8$\%$ 정도 향상되었으며 fuel NO의 제거로 질소산화물질은 1/3정도 배출되었다. 지구온난화 물질인 이산화탄소의 배출도 에너지 절감을 통해 6$\~$8$\%$ 정도 절감되었다. 이러한 결과는 국내 산업용 보일러의 효율향상 및 성능개선에 대한 분석적인 적용

  • PDF

Analysis of Safety and Performance Vulnerabilities Using Heat-Using Equipment(Industrial Boiler) Inspection Results (열사용기자재 검사대상기기(산업용 보일러) 검사결과를 활용한 안전 및 성능 취약점 분석)

  • Kim, Hyung-Jun;Oh, Choong-Hyeon
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.4
    • /
    • pp.18-26
    • /
    • 2022
  • The Korean government is conducting heat-using equipment(industrial boiler) inspection in accordance with the Energy Use Rationalization Act because of the heat-using equipment(industrial boiler)'s risks such as explosion and fire, and safe use and management. This paper aimed to setup the safe and performance vulnerabilities from database based on the inspection results for heat-using equipment(industrial boiler). This study surveyed the inspection results of 1,249 heat-using equipment(industrial boiler) which were failed inspection of heat-using equipment(industrial boiler) from january 2016 to december 2020. And the analysis method is to inform safety and performance vulnerability categories of heat-using equipment(industrial boiler) by statistically analyzing the failure reasons of boiler type and inspection type which are high variance in failure rate. The safety and performance vulnerability categories was abbreviated into 18 cases. And each catagory's main reason for failure was suggested by additional analyzing the opinions of inspectors. This paper would be the basic source and the comprehensive information dealing with the safety and performance vulnerability of heat-using equipment(industrial boiler).

Study of SNCR Application to Industrial Boiler for NOx Control (산업용 보일러의 질소산화물 제어를 위한 SNCR 적용 연구)

  • Shin, Mi-Soo;Kim, Hey-Suk;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.3
    • /
    • pp.286-292
    • /
    • 2005
  • This study is to investigate the industrial boiler which can be significantly affected by the restriction of NOx. Note that the application of SNCR method to industrial boiler is usually blown as not feasible due to the insufficient residence time for proper mixing. The purpose of this study is to investigate the applicability of the SNCR system application to the industrial boiler, which produces 40 tons of steam per hour using heavy oil. For the industrial boiler with 3-D rectangular coordinate, the general coding are made fur various turbulence modeling such as turbulent flow, turbulent fuel combustion, thermal NO formation and destruction together with the NO reaction with reducing agents. Further, the incorporation of drop trajectory model is successfully made in 3-D rectangular coordinate with Lagrangian frame and the main swirl burner effect on the characteristics of flame is considered. As expected a short flame was created and thereby NOx is removed more efficiently by increasing the proper region of temperature for NO reduction reaction. The validation of program was made successfully by the comparison of experimental data. Based on the reliable calculation results, the SNCR method in a industrial boiler shows the possibility as one of viable NO reduction method by the use of well designed mixing air of reducing agent.

산업용 보일러 효율개선을 위한 자동제어

  • 윤양균;박귀태;김석진
    • 전기의세계
    • /
    • v.37 no.6
    • /
    • pp.25-31
    • /
    • 1988
  • 본고에서는 에너지 효율개선의 측면에서 운전효율향상 뿐만 아니라 안전 및 수명연장에 기여할 수 있는 산업용 보일러의 자동제어장치에 대하여 그 개요 및 동향을 알아보기로 한다.

  • PDF

The high temperature oxidation behavior of X20CrMoV12.1 high-chromium steel (X20CrMoV12.1 고크롬강의 고온산화거동)

  • 정진성;김두수;김범수;김의현;하정수
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.46-46
    • /
    • 2003
  • 고크롬강은 산업용 발전설비의 효율적인 열교환을 위해 수천개의 튜브로 구성된 보일러에 적용되고 있다. 이러한 보일러 튜브는 고온에 노출되어 있으며, 튜브 내면에는 고온의 증기가 고압으로 존재하고 있다. 따라서 보일러 튜브는 장기간 고온의 환경에서 사용되기 때문에 고온강도와 고온내산화 및 내부식 특성이 요구된다. 보일러 튜브의 열화는 이세조직 변화에 따른 고온강도의 저하를 재료내부의 열화와 고온산화 및 부식 등 외부환경에 의 한 열화로 크게 두 가지로 대별된다. 이러한 보일러 튜브의 수명평가는 튜브의 수명을 미리 예측하여 적절한 시점에 교체함으로서 운전 중 손상에 따른 발전정지 등을 방지하여 막대한 비용을 절감할 수 있기 때문에 현장에서는 중요한 의미를 갖는다. 본 연구에서는 보일러 튜브의 여러 가지 수명평가 방법 중 현재 산업용 발전설비의 보일러에 적용되고 있는 X-20 고크롬강의 고온산화 거동을 조사하여 향후 보일러 튜브의 수명평가 방법 중 산화스케일을 이용한 방법에 활용하는데 있어 기초 자료로 이용하고자 한다.

  • PDF

'콘덴싱 가스보일러 소비효율 높다'

  • Korea Boiler Engineering Association
    • 보일러설비
    • /
    • no.3 s.170
    • /
    • pp.100-102
    • /
    • 2008
  • 콘덴싱 가스보일러의 열 효율이 일반 가스보일러에 비해 최고 9%까지 높은 것으로 조사됐다. 에너지 관리공단의 의뢰를 받아 '가정용 가스보일러 열효율 측정 및 효율등급 기준'을 연구해 온 가스안전공사는 최근 최종 결과를 발표했다. 지난 22일 가스안전공사 대회의실에서 개최된 연구결과 발표 공청회에는 산업지원부, 에너지관리공단, 가스안전공사 및 6개 보일러 제조업체 관계자가 참석해 연구용역 결과를 두고 뜨거운 논쟁이 벌어졌다. 콘덴싱 보일러와 일반 보일러간 난방효율 차이를 밝혀 내는 이번 연구 결과에 따라 국내 대표적인 6개 제조업체들의 시장 점유 판도가 달라질 수 있기 때문이다. 또한 가정용 가스보일러를 고효율 에너지기자재 인증대상에서 제외시킨다는 계획에 대해서도 상당한 이견이 제기됐다.

  • PDF