• Title/Summary/Keyword: 산란감쇠

Search Result 118, Processing Time 0.033 seconds

Seismic Analysis of the Korean Peninsula Using Multiple Lapse Time Window Method (다중지연시간창법(MLTW)의 한반도 지진자료 적용성 분석)

  • Chung, Tae-Woong;Yoon, Suk-Yung
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.2
    • /
    • pp.199-207
    • /
    • 2009
  • From 329 earthquake data in the Korean Peninsula, we separated the intrinsic and scattering quality factor ($Q_i^{-1}$ and $Q_s^{-1}$) using the Multiple Lapse Time Window Analysis (MLTW) method. For the homogeneous velocity structure, $Q_i^{-1}$ reduces the amplitudes of both direct and coda waves; $Q_s^{-1}$ diminishes the direct wave amplitude but enlarges the coda wave amplitude. Based on this phenomenon, MLTW method analytically derives theoretical curves and obtains $Q_i^{-1}$ and $Q_s^{-1}$ by least square fit with observation curves. This study is the first approach for the seismic stable region by MLTW method, and show that $Q_i^{-1}$ and $Q_s^{-1}$ in the Korean Peninsula are very low at lower than frequencies of 5 Hz. This low value seems to be related to the inactive tectonism of the Korean Peninsula.

A study on the debelopment of the Ultrasonic imaging system for tissue characterization (조직의 정량화를 위한 초음파 영상시스템의 개발에 관한 연구)

  • Choe, Jong-Ho;Choe, Jong-Su
    • The Journal of the Acoustical Society of Korea
    • /
    • v.6 no.3
    • /
    • pp.31-42
    • /
    • 1987
  • An ultrasonic pulse-echo diagnostic system for tissue characterization with the estimation of attenuation coefficients is developed and its performance has been examined by system implementation. The system divided into the ultrasonic generator, A/D converter, data communication, computer for signal processing. The methods for estimating the spatial distribution of acoustic attenuation coefficients using the moment analysis are proposed. The experimental results indicate the potential of the methods for tissue characterization.

  • PDF

Iterative Teconstruction of a Cylinder Buried in the Lossy Half Space (손실 반공간에 묻힌 원통형 산란체의 검출 및 영상제구성에 의한 식별)

  • 김정석;나정웅
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.6
    • /
    • pp.939-945
    • /
    • 2000
  • A cylindrical object buried in the lossy half space is reconstructed from the measured scattered fields above the lossy half space. The position, the size and the medium parameters i.e. relative dielectric constants and conductivity of the buried object as well as the medium parameters of the background lossy half space are obtained from the scattered fields by using the iterative inversion method and the optimization hybrid algorithm combining the genetic algorithm and the Levenberg-Marquardt algorithm. Illposedness of the inversion due to the measurement errors in the scattered fields are regularized by filtering out the evanescent modes in the spatial frequency spectrum domain.

  • PDF

Effects of Attenuation and Scatter Corrections in Cat Brain PET Images Using microPET R4 Scanner (MicroPET R4 스캐너에서 획득한 고양이 뇌 PET 영상의 감쇠 및 산란보정 효과)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Jong-Jin;Lee, Byeong-Il;Park, Min-Hyun;Lee, Hyo-Jeong;Oh, Seung-Ha;Kim, Kyeong-Min;Cheon, Gi-Jeong;Lim, Sang-Moo;Chung, June-Key;Lee, Myung-Chul;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.40-47
    • /
    • 2006
  • Purpose: The aim of this study was to examine the effects of attenuation correction (AC) and scatter correction (SC) on the quantification of PET count rates. Materials and Methods: To assess the effects of AC and SC $^{18}F$-FDG PET images of phantom and cat brain were acquired using microPET R4 scanner. Thirty-minute transmission images using $^{68}Ge$ source and emission images after injection of FDG were acquired. PET images were reconstructed using 2D OSEM. AC and SC were applied. Regional count rates were measured using ROIs drawn on cerebral cortex including frontal, parietal, and latral temporal lobes and deep gray matter including head of caudate nucleus, putamen and thalamus for pre- and post-AC and SC images. The count rates were then normalized with the injected dose per body weight. To assess the effects of AC, count ratio of "deep gray matter/cerebral cortex" was calculated. To assess the effects of SC, ROIs were also drawn on the gray matter (GM) and white matter (WM), and contrast between them ((GM-WM)/GM was measured. Results: After the AC, count ratio of "deep gray matter/cerebral cortex" was increased by $17{\pm}7%$. After the SC, contrast was also increased by $12{\pm}3%$. Conclusion: Relative count of deep gray matter and contrast between gray and white matters were increased after AC and SC, suggesting that the AC would be critical for the quantitative analysis of cat brain PET data.

Relationship between the Distribution of Space doses in X-ray Rooms and the "Inverse Square Law of Distance" (X선 촬영실 내 공간선량의 분포와 거리 역자승 법칙과의 관련성)

  • Choi, Seong-Kwan
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.301-307
    • /
    • 2013
  • In the present study, space doses generated during X-ray radiography of hand, head, and abdomen, etc. were examined and whether the intensity of space doses of scattering rays is attenuated by the "inverse square law of distance" was figured out. First, the space doses of X-ray with small amounts of generated scattering rays such as hand radiography were mostly attenuated by the "inverse square law of distance" and were not detected at all at a distance of 2m. Second, the space doses of X-ray with large amounts of generated scattering rays such as head or abdomen radiography attenuated in higher rates than the rates under the "inverse square law of distance" at distances ranging from 30cm to 1m from the center of the irradiation field and were attenuated by the "inverse square law of distance" at distances ranging from 1m to 2m. Therefore, in X-ray rooms, the subject should be at least 2m away from the center of the irradiation field in the case of hand radiography and X-ray exposure prevention actions using protective devices are required in the entire spaces of the X-ray rooms in the case of head or abdomen radiography.

Study of Optical Tomography for Measurement of Spray Characteristics at High Ambient Pressure (고압 환경에서의 분무 특성 계측을 위한 광학 토모그래피 기법 연구)

  • Cho, Seong-Ho;Im, Ji-Hyuk;Choi, Ho-Yeon;Yoon, Young-Bin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.4
    • /
    • pp.36-44
    • /
    • 2009
  • Spray cross-section was measured by the Optical Line Patternator (OLP) and Optical Tomography at high ambient pressure. The laser line beam passed through the spray region, then Mie scattered signal and transmitted light were captured. The measured signal was processed to obtain a distribution of attenuation coefficient in spray cross-section. Beer-Lambert's law and mathematical reconstruction methods were used to reconstruct the distribution of attenuation coefficient. Spray became dense at high pressure and attenuation of scattered signal occurred seriously. OLP method, which uses Mie scattered signal, showed limit in compensating attenuation problem in dense spray region. Optical tomography reconstructed spray cross-section well, from transmission rate of light penetrating spray region.

Fatty Liver Analysis through Quantitative Measurement Study of Ultrasonography Images (초음파 검사 영상의 정량적인 측정 연구를 통한 지방간 분석)

  • Hye-Ri, Chun;Hyon-Chol, Jang
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.927-934
    • /
    • 2022
  • This study attempted to find out the degree of agreement between ultrasound image findings along with analysis of attenuation index and scatter distribution index values within tissues through quantitative measurement analysis using liver ultrasound images. From August 2022 to October 2022, liver ultrasound was performed on 45 patients who were suspected of having fatty liver and who received a prescription for liver ultrasound. As a result of the study, as a result of analyzing the agreement between the ultrasound image findings and the tissue attenuation index, the Kappa value was 0.82 (p<0.05), showing a very high agreement between the two examination methods. In addition, as a result of the agreement analysis between the ultrasound image findings and the scatter distribution index in the tissue, the Kappa value was 0.642 (p<0.05), showing high agreement between the two examination methods. At the time of fat liver prediction, the use of liver ultrasound findings and quantitative ultrasonography techniques, such as intra-tissue attenuation index and intra-tissue scatter distribution index, may be helpful in determining the degree of progression of fatty liver patients.

The effects of physical factors in SPECT (물리적 요소가 SPECT 영상에 미치는 영향)

  • 손혜경;김희중;나상균;이희경
    • Progress in Medical Physics
    • /
    • v.7 no.1
    • /
    • pp.65-77
    • /
    • 1996
  • Using the 2-D and 3-D Hoffman brain phantom, 3-D Jaszczak phantom and Single Photon Emission Computed Tomography, the effects of data acquisition parameter, attenuation, noise, scatter and reconstruction algorithm on image quantitation as well as image quality were studied. For the data acquisition parameters, the images were acquired by changing the increment angle of rotation and the radius. The less increment angle of rotation resulted in superior image quality. Smaller radius from the center of rotation gave better image quality, since the resolution degraded as increasing the distance from detector to object increased. Using the flood data in Jaszczak phantom, the optimal attenuation coefficients were derived as 0.12cm$\^$-1/ for all collimators. Consequently, the all images were corrected for attenuation using the derived attenuation coefficients. It showed concave line profile without attenuation correction and flat line profile with attenuation correction in flood data obtained with jaszczak phantom. And the attenuation correction improved both image qulity and image quantitation. To study the effects of noise, the images were acquired for 1min, 2min, 5min, 10min, and 20min. The 20min image showed much better noise characteristics than 1min image indicating that increasing the counting time reduces the noise characteristics which follow the Poisson distribution. The images were also acquired using dual-energy windows, one for main photopeak and another one for scatter peak. The images were then compared with and without scatter correction. Scatter correction improved image quality so that the cold sphere and bar pattern in Jaszczak phantom were clearly visualized. Scatter correction was also applied to 3-D Hoffman brain phantom and resulted in better image quality. In conclusion, the SPECT images were significantly affected by the factors of data acquisition parameter, attenuation, noise, scatter, and reconstruction algorithm and these factors must be optimized or corrected to obtain the useful SPECT data in clinical applications.

  • PDF

The Antenna Coating Compound Performance Test for Rainfall Decrease Reduction (강우감쇠 저감을 위한 안테나 코팅제 성능 시험)

  • Hong, Sung-Taek;Shin, Gang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1777_1778
    • /
    • 2009
  • 한국수자원공사에서는 1998년부터 단계적으로 12~14 GHz의 Ku-band 대역을 사용하고 있는 무궁화위성을 이용하여 우량 및 수위, 경보 등의 데이터를 송수신하고 있으며, 특히 강우가 집중되는 기간 동안에는 그 데이터의 필요성이 더욱 큰 실정이다. 사용하고 있는 위성통신망 주파수의 파장은 2~2.5 cm 이므로 물방울 입자에 의해 산란되는 특징을 가지고 있으며, 이로 인해 안테나 및 휘드혼의 표면에 물방울이 묻어 있으면 전파가 산란되어 신호가 감쇠되는 특성을 가지고 있다. 따라서 본 연구에서는 강우시 안테나 및 휘드혼 표면에 발생하는 물방울 맺힘 현상에 대해 물방울과 전파신호간의 상관관계를 분석하고, 위성안테나 성능을 개선방안을 시험하여, 강우로 인한 위성신호의 감쇠를 최소화하여, 최적화된 안테나 성능 구현으로 강우 영향을 최소화하여 안정적인 위성단말국을 운영하고자 한다.

  • PDF