• Title/Summary/Keyword: 사진측정기

Search Result 28, Processing Time 0.026 seconds

Current status and application of Photogrammetry (사진측정기의 동향 및 응용사례)

  • Choi, Jung-Su;Park, Eung-Sik;Kim, Hyung-Wan;Yoon, Yong-Sik
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.6 no.2
    • /
    • pp.80-89
    • /
    • 2008
  • Photogrammetry is a non-direct 3-dimensional coordinate measurement technique using 2-dimensional photographic images. For reconstruction 3-dimensional data from the 2-dimensional photos, photogrammetry uses the fundamental principle of triangulation. Digital photogrammetry solve for the camera location and coordinates simultaneously through the mapping, scaling and bundle processing in software processing. In this paper, several applications for photogrammetry measurement are introduced, such as 'photogrammetric measurement of the gravity deformation of a cassegrain type antenna', 'analysis of photogrammetry data from ISIM mockup', 'underwater photogrammetric verification of nuclear fuel assemblies', 'spacecraft optical bench measurement' and 'spacecraft ground support equipment measurement'.

  • PDF

The Application of Line Measurement Method for 3D Modeling of Construction (구조물의 3차원 모델링을 위한 직선측정기법의 적용)

  • 강준묵;김위현;강기석
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2002.10a
    • /
    • pp.117-120
    • /
    • 2002
  • 일반적으로 많은 건축물들은 형태의 규칙성에 기인된 일련의 정의된 규칙을 이용하여 축조된다. 하지만, 기존 사진실측으로 건축물에 대한 3차원 모델링을 수행하기 위해서는 많은 기준점의 배치, 영상의 피복범위에 따른 촬영점 선점, 중복도 고려 등 다소 복잡한 절차가 수반된다. 본 연구에서는 평행, 수직성, 평면과 같은 대상물에 대한 사전정보가 유용하게 적용될 수 있는 건축물의 3차원 재건분야에 직선측정기법을 적용함으로써, 기존의 까다로운 조건을 탈피하여 보다 효율적으로 3차원 모델을 재현해 본 후, 정확도 검증을 통해 건축물 사진측량 분야에 이러한 기법의 효용 가능성을 제시하고자 하였다.

  • PDF

The Behavior Measurement of Simulated Ground by Digital Close-Range Photogrammetry (수치근접사진측량을 이용한 모형지반 거동량 측정)

  • Lee, Hyo-Seong;Ju, Jae-Woo;Jung, Jae-Sung;Ahn, Ki-Won
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.2
    • /
    • pp.59-65
    • /
    • 2008
  • Digital close-range photogrammetric technique can measure and describe 3D geometric farm from 2D image. This technique is increasingly applied in the field of sciences. In the fields of civil and mechanical engineering, which need precise measurements for design, expensive measuring equipments are widely used. In occasions where visual inspection is required in addition to other forms of measurements, appropriate measuring equipments have not been yet available. This study utilizes digital close-range photogrammetric technique to quantitatively analyze behavior patterns before and after destruction from test model of reinforced-soil wall. Then the results are compared with the measurements obtained using digital theodolite to verify the reliability of the proposed method.

Effective Application of Close-Range Photogrammetry with Digital Images in Industrial Precise Measurement (산업정밀측정에서 수치영상을 이용한 근접사진측량의 효율적 응용)

  • 이진덕
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.14 no.1
    • /
    • pp.17-25
    • /
    • 1996
  • The development of still video CCD cameras has simplified dramatically the digital imaging process. Still video cameras have flexibility that allows digital image acquisition and on-board image storage without being connected to a computer. The objective of this paper is to evaluate the performance of digital close-range photogrammetric system using the still video camera for dimensional inspection and structural monitoring being required in various industries. Some sub-pixel measurement techniques, which is indispensable for digital image measurement, were suggested. The author carried out the self-calibration of a high resolution DCS420 still video camera and then test application of a structure. The self-calibrating bundle adjustments resulted in object space accuracies which exceed 1 :46,000. It is ascertained that this digital close-range photogrammetric system has high accuracy potential and task effectiveness for industrial applications.

  • PDF

Determination of Surface Energy by Means of Home-Made Goniometer and Image Analyzing Software for Contact Angle Measurement (수제 접촉각 측정기와 영상 분석 프로그램을 이용한 표면에너지의 측정)

  • Cho, Seo-Rin;Cho, Han-Gook
    • Journal of the Korean Chemical Society
    • /
    • v.57 no.4
    • /
    • pp.432-438
    • /
    • 2013
  • We report a contact angle goniometer that can be easily assembled and used in high school and general chemistry experiments. It consists of an LED flash, a sample stand, and a camera fixed on an optical bread board, and the sample area is covered to block light from outside with a box with holes on both sides. ImageJ, free image analyzing software and a JAVA plugin (Drop_analysis) were used to determine the contact angle of liquid drop resting on solid surface. The contact angles of various liquids were successfully measured on various surfaces. The solid surface energies have also been determined using the Owen-Wendt method from the contact angles of $H_2O$ and $CH_2I_2$. The results reasonably agree with the previously reported values, showing the surface characteristics and modification as well as the dispersive and polar contributions. These contact angle goniometer and method for determination of the contact angle and surface energy can be applied to observation of various surface properties including wettability, hydrophilicity, and water repelling. Students can learn how the surface properties are related to the intermolecular interactions and gain experience about the equilibrium between the related forces, optics, and mathematical derivations.

Construction of an ideal set-up model for lingual orthodontic treatment (설측 교정치료를 위한 셋업 모형 제작의 정밀도)

  • Bae, Gi-Sun;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.35 no.6 s.113
    • /
    • pp.459-474
    • /
    • 2005
  • Making a precise and ideal set-up model is an essential part in the indirect bonding procedure for lingual orthodontic treatment. To evaluate the accuracy of the making a set-up model, 22 adult patients who received lingual orthodontic treatment with 4 bicuspid extractions were selected, and 3 sets of dental models (before, set-up, and after treatment) were measured using the set-up model gauge, an instrument for measuring the inclination and angulation of the clinical crowns on the dental model. Two sets of lateral cephalograms (before and after) from each patient were also evaluated. The mean difference between the before treatment model and the set-up model was $-3.93{\pm}6.98^{\circ}$ for the inclination and $1.87{\pm}5.79^{\circ}$ for the angulation. And the mean difference between the set-up model and the after treatment model was $-4.31{\pm}5.91^{\circ}$ labiolingually and $-2.16{\pm}3.27^{\circ}$ mesiodistally, The after treatment model differed from the before treatment model about $-8.24{\pm}5.39^{\circ}$ in inclination. There were no significant difference between the measured gauge that measured from the dental model using the set-up model gauge and the calculated gauge angle measured from the lateral cephalogram using constructed points and lines. Using the set-up model gauge, it is possible to evaluate the study model 3-dimensionally in relation with the patient's lateral cephalogram and establish whether the doctor's prescription or overcorrection is built in the set-up model precisely.

AN ACCURACY OF THE SEVERAL ELECTRONIC APEX LOCATORS ON THE MESIAL ROOT CANAL OF THE MANDIBULAR MOLAR (하악 대구치 근심근관에 대한 전자근관장 측정기의 정확도)

  • Cho, Young-Lin;Son, Wook-Hee;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.6
    • /
    • pp.477-485
    • /
    • 2005
  • The aim of this study was to compare the length between the mesio-buccal and mesio-lingual canal of the mandibular molars before and after early coronal flaring at the different measuring time using several electronic apex locators. Fifty mandibular molars with complete apical formation and patent foramens were selected. After establishing the initial working length of the buccal and lingual canal of the mesial root using a surgical microscope (Carl Zeiss Co Germany) at 25X with #15 K-fle tip just visible at the foramen, radiographs were taken for the working length. After measuring the length of mesio-buccal and mesio-lingual canal (control group), the electronic lengths were measured at different times using several electronic apex locators (experimental groups; I-Root ZX, II-Bingo, III-Propex, IV-Diagnostic). After early coronal flaring using the $K^3$ file, the additional electronic lengths were measured using the same manner The results were as follows: One canal has a correct working length for the mesial root of the mandibular molar, it can be used effectively for measuring the electronic working length of another canal when the files are superimposed or encountered at the apex. In addition, the accuracy of the electronic apex locators was increased as the measurement was accomplished after the early coronal flaring of the root canal and the measuring time was repeated.

3D Modeling of Automobile Part Using Pattern Scanner and Efficiency Analysis (패턴스캐너를 이용한 자동차부품의 3차원모델링 및 효용성분석)

  • Han Seung-Hee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.24 no.1
    • /
    • pp.1-8
    • /
    • 2006
  • Effective three dimensional modeling becomes essential in a wide range of drawings, such as construction, machinery and design. In particular, it has been developed as the tool enabling reverse design. Three dimensional modeling requires rapidity, accuracy and tangibility. Data acquisition methods for modeling including contact type coordinate measurement machine, LASER scanner, pattern scanner and digital photogrammetry. In this study, we try to analyze modeling techniques as well as introduce three dimensional modeling using pattern scanner. In addition, this study conducts three dimensional modeling using OPTO-Top pattern scanner with distinguished accuracy and rapidity, and then compare efficiency with digital photogrammetry. And, this study attempts to form environment that enables to turn around models on web in three dimensional ways.

A Study on Measurement Error Factors of Theodolite System (데오도라이트 시스템의 측정 오차 요인에 대한 연구)

  • 윤용식;이동주
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.4
    • /
    • pp.36-42
    • /
    • 2003
  • Theodolite measurement system is non-contacted 3-dimensional measurement system. The system accuracy is ${\pm}0.5mm$or better for distance 0~100m. And the system is used for the measurement of a product of middle and large scale. This study is performed for the measurement error factors of the system. We could know that the main measurement error factors are temperature, illumination and skill. Also, we performed the study for the effect according to the height difference of scale bar.

An Application and Evaluation of a Water Level Detection Method by Correlation Analysis for Successive Watermark Images (시차가 있는 수위표 이미지의 상관분석을 통한 수면측정기법의 적용성 검토)

  • Seo, Myoung-Bae;Lee, Chan-Joo;Kwon, Sung-Il;Kim, Dong-Gu
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2012.06b
    • /
    • pp.43-45
    • /
    • 2012
  • 본 논문은 목자판과 수면이 포함된 시차가 있는 연속적인 두 영상을 이용하여 수면위치를 탐색하는 방법과 그 적용성을 평가한 결과를 기술한다. 수위표 상단으로부터 특정 크기의 직사각형 검사영역을 설정하고 짧은 시차를 가진 두 영상의 동일한 위치의 검사영역에 대해 상관계수를 산정한다. 이렇게 함으로써 물의 흐름으로 픽셀 농도가 변화하는 수역과 픽셀 농도가 고정되어 있는 육역을 구분한다. 제안한 기법을 검증하기 위해 실험실에서 촬영한 사진을 분석하였다. 검사영역의 크기에 따라 상관계수 특성이 달라짐을 확인하였으며, 검사영역이 수위표 전체 폭에 걸쳐 있는 경우에 상관계수에 따른 수면특성이 뚜렷이 나타나 제안된 기법이 수면을 찾는데 활용될 수 있음을 확인하였다.