• Title/Summary/Keyword: 사용종료매립지

Search Result 33, Processing Time 0.025 seconds

Reclamation of Closed Non-Sanitary Landfills by Sorting Transfer Control (선별이적처리를 통한 사용종료 비위생매립지 정비방안 연구)

  • Kim, Dongoh;Kim, Taekyoung;Kim, Mihwa;Kim, Moonil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.1
    • /
    • pp.15-23
    • /
    • 2009
  • The aim of this study was an evaluation of closed non-sanitary landfill's stabilization degree and a determination of its an optimal reclamation method. In order to evaluate the stabilization degree, physical compositions of landfill wastes in 21 closed non-sanitary landfills were analyzed. There were 4 major items such as cover soils, organics, combustibles and incombustibles. With respect to the results of physical compositions, it was determined that the waste in 9 sampling sites of closed non-sanitary landfills after 10years of the relief time was not fully stabilized. The closed non-sanitary landfills must be reclaimed as soon as possible. The main material in closed non-sanitary landfills was cover soils and the highest content was 89.96%. Otherwise, the contents in sanitary landfills was small and 9.89~11.12%. Therefore, it was evaluated that the recovered soil by sorting transfer treatment could be reused as on-site cover soils of the reclamating non-sanitary landfills and/or constructing materials.

  • PDF

Filter Clogging of Leachate Collection and Removal System at Waste Landfill (불량폐기물 매립지 및 주변토양 오염도에 관한 연구)

  • 김동우;한영수;이재영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.310-313
    • /
    • 2000
  • 본 연구에서는 현재 사용 종료된 매립지 재사용을 위해 정비를 실시 중인 전국 매립지 중에서 충남 공주시 금홍동에 위치한 사용 종료된 매립지를 대상으로 하여 사업 지구 및 그 주변지역의 환경질 평가를 위하여 토양에 관한 오염도 조사를 실시하였다. 시료는 매립지 내 1개 지점과 주변 논 2개 지점, 밭 1지점으로 총 4개 지점에서 채취하였다. 토양시료의 분석항목은 토양환경보전법에서 제시하는 총 11개 항목으로 하였으며, 실험방법은 토양오염공정시힘방법에 준하여 실시하였다. 실험결과 토양환경보전법상 농경지에 대한 우려기준과 비교하여 전 항목이 기준에 크게 미치지 못하는 것으로 나타났다. 토양질의 면에서 된다면 이 매립지 부지는 일반적인 용도의 토지로써 사용이 가능하다고 사료된다.

  • PDF

Assessment of Stabilization of An Open-dumping Landfill - A Case Study of Noeun Landfill - (비위생매립지의 안정화 평가 - 노은 매립지 사례연구 -)

  • Hong, Sang-Pyo;Kim, Kwang-Yul
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.2
    • /
    • pp.47-53
    • /
    • 2005
  • 노은 매립지는 사용종료된지 5년이 경과된 비위생매립지로 최종복토는 되어 있으나 침출수 차집시설 및 매립가스 포집설비가 제대로 갖추어지지 않은 상태이다. 환경부의 사용종료 매립 지 정비지침에 의하면 침출수의 BOD/CODcr 비율이 1/10 수준임으로 침출수의 안정화 과정이 거의 완결상태로 진행되고 있는 것으로 판단된다. 매립지 가스의 안정화 측면에서는 CH4의 비 율이 5%정도이기 때문에 안정화가 거의 이루어진 것으로 볼 수 있다. 매립된 쓰레기 중에서 플 라스틱을 제외한 가연물 함량이 3.97 - 9.34%이기 때문에 매립폐기물은 안정화 기준에 미흡한 상태이다. 그리고 지하수는 대장균 항목이 지하수 수질기준 생활용수 기준에 미흡하여 안정화 기준을 충족시키지 못하고 있다. 노은매립지는 매립지 안정화의 속도가 평가 대상별로 상이하 게 진행되는 것으로 평가된다.

Case Study of Remidation and Investigation of Closed Unsanitary Landfill for Prevention of Leachate (비위생매립지 정밀조사 및 침출수 방지를 위한 정비방안 연구)

  • Kim, Sangkeun;Lee, Yongsoo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.1
    • /
    • pp.5-13
    • /
    • 2012
  • For the last decade the amount of waste has rapidly been increased in South Korea and many waste landfills have been built according to government guidelines specifying required systems such as landfill liner, leachate collecting facilities, final cover system, etc. This effort has led the recently constructed landfills to be under well managed sanitary condition. In a meanwhile closed waste-landfill sites in the past before the adoption of the government guidelines exits under unsanitary condition. In these cases untreated leachate flew out to the surroundings due to the absence of liner and leachate collecting facilities and caused groundwater and soils to be contaminated. Waste generated odor and gas also brought civil complaints. Because environmental influences bring serious problems nearby sites, it is required to have unsanitary waste-landfills to be appropriately treated and managed. A study to evaluate environmental influence and contamination level of surroundings nearby and on the unsanitary landfills is necessary before the establishment of "Management guide of closed landfill site." This paper presents an environmental evaluation for the closed site, Doil-dong landfill, according to "Closed landfill management regulation" by Ministry of Environment. "D" landfill, located in Pyeongtaek city, has possobility to contaminate surrounding surfacewater and groundwater by leakage of leachate. The in-situ stabilization carried out to build the DMW(deep soil mixing cutoff wall) wall and drainage systems.

Characteristics of Leachate with Passed Time in Expired Landfill (사용종료매립지에서 시간경과에 따른 침출수의 특성)

  • Kim, Eun-Ho;Kim, Hyeong-Seok;Sung, Nak-Chang;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.2
    • /
    • pp.136-141
    • /
    • 1997
  • In this study, we can be obtained the following conclusions about the characteristics of leachate with passed time in the expired landfill. Compared with the expired landfilling H. and S., pH shows a tendency to increase in E., because $NH_3$ is created by anaerobic degradation and dissolved in leachate. The initial BOD and COD of E. and S. are high in similar concentration but H. is low, Since the organics of waste in H. are lower than in E. and S. during landfilling. SS of E. in concentration is increased and very altered, because food of combustible in E. is higher than it in H. and S.. According to passed time, T-N is high in concentration but T-P shows a similar tendency. Heavy metals of leachate is lower than threshold concentrations. If leachate is treated biologically, microbes are not inibitory.

  • PDF

The Effect of Final Cover Installation on the Waste Landfill Stabilization (차단형 최종복토층 설치가 폐기물 매립지 안정화에 미치는 영향)

  • Yoon, Seok-Pyo;Jung, Jinmo;Wei, Jieling
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.25 no.2
    • /
    • pp.33-40
    • /
    • 2017
  • In Korea, it is required to install the final cover layer immediately after the end of use of the waste landfill, and to conduct aftercare for 30 years. However, the installation of the final cover layer minimizing the penetration of the rainfall will delay the decomposition of the buried organic wastes and reduce the amount of pollutants released into the leachate. Therefore, at the end of the aftercare period, pollutants might be discharged and cause the pollution of the surrounding environment. In this study, using lab-scale lysimeters, the amount of pollutants discharged into the leachate was observed. At the initial stage, same artificial rainfall was injected, and after 7 months later, different reduced artificial rainfall was injected for 8.4 months assuming as the final soil layer was installed. From the results, it was advantageous in terms of environmental management after the end of the aftercare period to install a temporary cover layer that permits the infiltration of rainfall to some extent rather than to install the final cover layer immediately after the end of use of the waste landfill.

Estimation of Landfill Gas Utilization in Old Landfill (사용 종료 매립지의 가스 활용 방안 평가)

  • Lee, Cheol-hyo;Jeon, Yeon-ho;Lee, Chae-young;Kim, Kyung;Lee, Hwan;Lee, Nam-hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.2
    • /
    • pp.154-160
    • /
    • 2000
  • Landfill gas (LFG) utilization in old landfill was estimated using LFG models. The results showed that Scholl Canyon model best described the LFG generation. LFG was extracted more than the amount of natural production which caused air inflow from outside that resulted in dilution of methane concentration and increase of oxygen concentration. It was negative for the LFG utilization. Therefore, to use LFG, the plan of stabilization by LFG extraction should be ineffective. The use of LFG will have no problem if LFG is extracted less than the amount of natural production which was estimated based on modeling. At 8 years elapsed from landfill, now, the amount of natural landfill gas production was decreased sharply. The plan for using LFG from old landfill is feasible if LFG is used for the less than the amount of natural production as a small scale even though for the aspect of efficiency, it was less economic than use of LFG just after closing landfilling and it was helpful for stabilization of landfill by LFG extraction.

  • PDF

Evaluation of Groundwater Quality Characteristics around Uncontrolled Closed Valley Landfill (사용종료 비위생매립지 주변 지하수의 수질변화 특성)

  • Park, Joung-Ku;Kim, Tae-Dong;Choi, Dong Hyuk;Lee, Jin-Yong
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.3
    • /
    • pp.75-80
    • /
    • 2007
  • This study evaluated groundwater quality around an uncontrolled landfill in W sity, Korea, which was monitored for about two years (2005-2006). Parameters of concern include redox-sensitive indicators such as pH, DO, EC, ORP, DOC (dissolved organic carbon), NH3, NO3 and SO4. About 10 years have elapsed after closing dumping of municipal wastes in the landfill. Leachates showed widely varying concentrations in COD(136${\sim}$263 mg/L), T-N(121${\sim}$186 mg/L), and NH3-N(14${\sim}$369 mg/L). Groundwater at the immediate downgradient of the landfill showed weakly acidic pH condition but very high levels of EC (3,000-4,000 ${\mu}S/cm$), which indicated that the groundwater was largely affected by the landfill leachate. Cl, a conservative ion, showed over 200 mg/L at the landfill border, but a gradually decreasing level with distance from the landfill, representing dispersion and dilution (natural attenuation) due to mixing with surrounding groundwater and replenished rainwater. Redox potential showed negative value at the landfill border but it increased up to 350 mV at downgradient wells, which indicated conversion of redox condition from reducing oxic ones. Ammonia, was largely enriched at most of the monitoring wells and its level greatly exceeded drinking water standard. In summary, all the parameters evidenced occurrence of natural attenuation with distance and with time but further monitoring is still required.

Analysis by Environmental Factor of Similar Closed Non-sanitary Landfills (사용종료된 유사비위생 매립지들의 환경인자 분석)

  • Lee, Byungchan;Lee, Minhee;Park, Sangchan;Jeong, Seonki;Han, Yangsu;Yeon, Ikjun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.6
    • /
    • pp.27-33
    • /
    • 2009
  • In this study, it was analysed physical characteristics, TS, moisture, C/N ratio, leaching test, and element analysis in landfill wastes of 10 years old without landfill pretreatment. The Organic material content was 7.2%~23.5% and soil was the main inorganic materials which it's rate was 54.1%~71.0%, in landfill wastes. The results of TS, VS, and moisture were represented 51.5%~68.1%, 23.6%~56.1%, 32.0%~48.4%, respectively. The analysis of hazardous materials did not indicate Hg, $Cr^{+6}$, CN, Organic Phosphorus, TCE and PCE, however the Pb of leaching materials showed 0.023~0.092 mg/L, which was the highest. As the result of the element analysis, C was 47.74%~56.72%, N was 4.09%~9.92%, the C/N ratio was 5.76~12.57 and the result of soils around landfill was the highest heavy material, Pb, 2.465 mg/kg~10.251 mg/kg. The objectives of this paper are to investigate states, stabilization of these closed landfills and to gain suitable data for post-closure care using some parameters through analysis of landfill environment.

  • PDF

Reuse Alternatives Analysis of Closed Unsanitary Landfills (사용종료 비위생 매립 부지의 활용 방안 연구)

  • Kim, Taedong;Park, Jong-Woong;Choi, Donghyuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3997-4001
    • /
    • 2014
  • The aim of this study was to suggest site-specific reuse alternatives for closed unsanitary landfills (CULs) scattered in Gyeongbuk Province. The CULs were classified with the factors affecting the site reuse alternative to provide basic data for systematic site reuse. Statistical analysis showed that the site area was the main factor in site classification among the site area, distance to road, and distance to the village. The results proposed a site-specific guide flow to the reuse of the CULs.