• Title/Summary/Keyword: 사방향 검사

Search Result 14, Processing Time 0.018 seconds

The Study of Effectiveness in a Modified Rib Oblique Projection View Using a Chest Phantom (흉부팬텀을 이용한 변형된 늑골 사방향 검사의 유용성에 관한 연구)

  • Um, Ki-Tae;Lee, Min-Su;Kang, Sung-Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.525-532
    • /
    • 2018
  • This study is filmed by applying the axial angle variation of the X-ray tube instead of the patient's position change during the perimetric examination of the ribs. A Reference image with the rib oblique examination using a chest phantom and experimental images applied with a six-phase variation in the axial angle by increasing $5^{\circ}$ tube angle each from $5^{\circ}{\sim}30^{\circ}$ from the vertical incident direction of the chest phantom to the right horizontal axis were obtained. For the quantitative comparative evaluation of the images, SNR and CNR were calculated for regions of interest in the experimental images based on the reference image. Also, the left-right rib ratio in the reference image and the left-right rib ratio in the experimental images are measured and compared. As a result of the study, the experimental images with a tube angle of $25^{\circ}$ were best shown in the measurements of the SNR, CNR and left-right rib ratio compared to the reference image with a standard examination method. The modified rib examinations will consider useful, if it is difficult to maintain the patient's examination position.

Comparison of the Surface Dose of the Thyroid according to AP versus PA Positioning in Cervical Spine Oblique View (경추 사방향 검사에서 전후면과 후전면 자세에 따른 갑상선 표면선량 비교)

  • Park, Jeong-Ho;Yang, Sung-Gyu;Kim, Ki-Jeong;Joo, Young-Cheol;Hong, Dong-Hee;Lim, Woo-Taek
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.543-548
    • /
    • 2017
  • The aim of this study was to evaluate anteroposterior oblique(RPO, LPO) and posteroanterior oblique(LAO, RAO) projections of the cervical spine, at various kVp and mA s increments, in order to compare thyroid surface dose. Using Rando phantom, dosimeter was attached to the Cervical spine 4~5 to measure the surface dose in the same thyroid position. As a result, the surface dose was $595.08{\pm}215.01{\mu}Gy$ for anteroposterior oblique(RPO, LPO) projections and $64.21{\pm}33.49{\mu}Gy$ for posteroanterior oblique(LAO, RAO) projections by changing kVp increment. The surface dose was $445.20{\pm}230.90{\mu}Gy$ for anteroposterior oblique(RPO, LPO) projections and $44.51{\pm}22.77{\mu}Gy$ for posteroanterior oblique(LAO, RAO) projections by changing mAs increment. The posteroanterior oblique method could reduce about 90% the surface dose than the anteroposterior oblique method. There were statistically significant differences among the examinations(p<0.001). Change the direction of position to reduce the surface dose at oblique projection of cervical spine. Therefore, we consider posteroanterior oblique projections than anteroposterior oblique projections of cervical spine examination in other to reduce patient surface dose.

Evaluation of the Clinical Usefulness of an Assistive Device Fabricated by 3D Printing in an Oblique X-ray Examination of the Lumbar Vertebrae (허리뼈 사방향 X-선 검사에서 3D 프린팅으로 제작된 보조기구의 임상적 유용성 평가)

  • Kim, Hyeong-Gyun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.505-512
    • /
    • 2022
  • In this study, a 3D printed assistive device was applied to X-ray examinations to diagnose human diseases. Based on the results of evaluating the device, statistical and regression analyses were conducted to evaluate its clinical utility and purchase intention, respectively. In the experiment, 90 radiologists performed X-ray examinations on patients who agreed with the use of the assistive device in oblique view X-rays of the lumbar spine, and then statistical analyses were undertaken with a traditional aid and factor analysis. The non-standardized coefficient values of the multiple regression analysis performed by setting the purchase intention of the 3D printed device as the dependent variable and the 3D printed device and traditional aid calculated by factor analysis as independent variables were 0.893 (p<0.001) and 0.269 (p<0.001), indicating statistically significant results. The results show that the 3D printed assistive device proposed in this study has higher clinical utility than traditional aids used in oblique view X-rays of the lumbar spine.

A Study on the Usefulness of the New Foot Oblique Projection (새로운 발 사방향 검사법의 유용성에 관한 연구)

  • Kim, Min-Suk;Joo, Young-Cheol;Lee, Seung-Keun
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.443-449
    • /
    • 2021
  • In this study, the purpose is to present the foot inclination angle for realizing an image similar to that of the existing examination method and to present the clinical usefulness of the new examination method through comparison between the existing examination method and the newly designed standing foot oblique projection. A foot phantom was used, and the magnification of the image according to the angle was quantitatively evaluated by attaching a nut to the position of the cuboid of the phantom. The internal oblique image acquired using a 30° wedge was set as the standard image. And that image was compared with the images acquired by changing the angle of the foot from 20° to 65° at intervals of 5°. Image evaluation was performed by 3 radiological technologists, and qualitative evaluation using a Likert 5-point scale for evaluation items of true oblique view and quantitative evaluation of the value obtained by measuring the diameter of a nut in each image were performed as image evaluation. For data analysis, reliability analysis between the measure and comparative analysis of the average value for each angle were performed. The qualitative evaluation score for each image was 4.5 to 5 points for most questions in the case of the standard image. And 4 points or less for most questions in the images with a foot angle of 45° or less, and an evaluation score close to the standard image was obtained in the image of 50° or more. And in the quantitative evaluation, the diameter of the nut was measured to be 9.28~9.56 mm. The qualitative evaluation showed a reliability of 0.95~1.0 and the quantitative evaluation was 0.62. As a result of comparing and analyzing the average of the quantitative and qualitative average values for each angle image, the group with the average value most similar to the standard image was images obtained at 55° and 60°, and in the post-analysis, the images of both groups were the same group as the standard image(p<0.01). As a result of this study, it was found that the angle of inclination of the foot for realizing the image most similar to the existing image in the standing foot oblique projection is 55°~60°. In addition, if this test method is applied to the clinic, it is believed that it will help prevent safety accidents such as falls during the test and improve test efficiency by minimizing the movement of patients for the test.

A Study on the Optimization of Exposure condition at Lumbar projection Using Blind Test (블라인드 테스트를 통한 요추 검사 시 조사 조건의 최적화 연구)

  • Park, Jikoon;Kim, Kyotae;Yoon, Inchan;Choi, Ilhong;Jung, Hyungjin;Kang, Sangsik;Noh, Sicheul;Jung, Bongjae
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.389-395
    • /
    • 2013
  • This study intended to investigate the optimum conditions for lumbar test that has the highest level of irradiation conditions among general test sites. To to this, the most widely used irradiation conditions in terms of statistics were set as standards; test groups applied with DMF were selected; tests groups suitable for clinical trials were selected by using suggested patient dose. Blind tests were conducted by 10 specialists and radiologists. The results suggested that under the optimum conditions, the radiation dose reduction of 2.09 mGy, 4.42 mGy and 3.65 mGy can be achieved in forward-backward test, lateral test and 4-direction test, respectively. There is a need of further studies on the optimization of irradiation conditions in accordance with the conditions of patients.

Technical Details Imaging Axillary Lymph Nodes in Breast-Specific Gamma Imaging (유방특이감마영상검사에서 액와부 영상 획득 방법에 대한 연구)

  • Jang, Ji Yeon;Jung, Eun Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.115-119
    • /
    • 2012
  • Purpose : The initial Breast-Specific Gamma Imaging (BSGI) protocol included bilateral breast imaging with 2 views of each breast-craniocaudal (CC) and mediolateral oblique (MLO). Furthermore, Axillary lymph nodes view can be acquired easily. The most meaningful prognosis factor for prediction of breast cancer is whether or not the breast cancer has metastasized to the lymph nodes. However, axillary view doesn't conduct in clinical. This article collates a diverse data of BSGI and describes technical details to acquire optimal imaging. Materials and Methods : A retrospective review was performed on 343 patients who had undergone BSGI between May 2011 and March 2012. Patients who had undergone BSGI received intravenous injection of 740 MBq (20 mCi) $^{99m}Tc$-sestamibi. Results : The following contents are the technical details for optimal axillary imaging. $^{99m}Tc$-sestamibi should be administered using an indwelling venous catheter or scalp needle followed by 10 cc of saline to flush to reduce extravasation and vascular trapping. After administration, patients raise their arm over their head and exercise with stress ball for 1 full minute. A lead shield attached to the gamma camera is removed and patients axilla is placed as close as possible to the camera at a $90^{\circ}$ angle. A lead apron is placed across the shoulder to reduce background from other organs. Acquisition time is enough for 120 sec~180 sec. Conclusion : If patients undergo bilateral axillary imaging as a standard with CC, MLO views, it could improve cancer treatment. Result of this study could maximize efficiency axillary imaging of breast cancer patients.

  • PDF

Study on the Breast Tissue Uptake according to Body Temperature on Molecular Breast Imaging (Molecular Breast Imaging 검사 시 체온 변화에 따른 유방 섭취율에 관한 고찰)

  • Kim, Ji Hyun;Baek, Song Ee;Oh, Shin Hyun;Ham, Jun Cheol;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.20-24
    • /
    • 2019
  • Purpose Molecular Breast Imaging (MBI) scan is used in nuclear medicine, for which $^{99m}Tc-sestaMIBI$ is administered by intravenous injection. However, the breast uptake rate of $^{99m}Tc-sestaMIBI$ is less than 1% of the total dose administered, relying on blood flow conditions of organs. The purpose of this study is to evaluate the impact of changes to body temperature on the uptake of $^{99m}Tc-sestaMIBI$ in breast tissue. Materials and Methods We investigated 30 breast cancer patients who performed more than one follow-up MBI scan. All scans were acquired by Discovery 750B (Genral Electric Healthcare, USA). $^{99m}Tc-sestaMIBI$ injected with 740 MBq (20 mCi), after 60 minutes, gained bilateral breast CC (CranioCaudal), MLO (Medio Lateral Oblique) View. The follow-up examination was then classified into 15 body temperature control group and 15 body temperature non-control group, and gained breast image in the same way as before. The breast uptake rate was analyzed in the MLO View of the opposite side of the lesion, and blind images were evaluated. Results The breast uptake rate increased by 30.31% in the body temperature control group and it was statistically significant(P<0.05), and 0.96% in the body temperature non-control group, and it was not statistically significant(P=0.955). There was a significant difference in the uptake rate between the body temperature control and the non-control group of P value of 0.01. Evaluation of blind images showed significant results in terms of the quality of the images. Conclusion Increased breast tissue uptake was observed when the subject was kept warm. When the body temperature was raised after injection, dilation of the peripheral blood vessels can be achieved. As a result, the blood flow became smooth and the breast uptake rate increased. In addition, an increase in breast tissue uptake will improve the quality of images.

The shoulder diagnosis Scapula study of patients who visited the hospital (병원 내원한 환자 견갑골(scapula) 진단을 위한 연구)

  • Ahn, Byeong-Ju;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.2
    • /
    • pp.13-20
    • /
    • 2010
  • True lateral scapula image was very important to diagnosis the scapula fracture and dislocation induced by traumatic injury. The aim of this study was to know the patient rotation angle to be showing the scapula true lateral in korean. d Materials Thirty patients(22men, 8 women, mean ages 53.4)with scapular pain, had supine Anteroposterior projection taken with $30^{\circ}$, $40^{\circ}$, $45^{\circ}$ trunk rotation angle changing the manual angulation material. Radiographs were evaluated independently by 5 experienced observers(1 orthopedics surgery specialist, 1 diagnostic radiology specialist, 3 radiological technologist) They assessed overlap of vertebral border and axillary border of scapula as follows; Totally overlapping of vertebral border and axillary border is 4, partially overlapping is 3, not overlapping is 2 and oblique location with two borders is 1. All observers scored using by PACS monitor.$30^{\circ}$ trunk rotation was scored $1.53{\pm}0.39$, $40^{\circ}$ trunk rotation was scored $3.83{\pm}0.15$ and $45^{\circ}$ trunk rotation was scored $2.17{\pm}0.43$. There was no difference(p<0.05) between group of more than 100cm of the girth of the chest and group of less than 100cm. Similarly, men and women group showed no difference(p<0.05) with trunk rotation statistically. There was no result of trunk rotation angle to radiograph the true scapula lateral image up to date. This studies were summarized as follows; Adaptation of $40^{\circ}$ trunk rotation was the best to show the true scapula lateral image in korean. Our results were very useful to get the true scapula lateral images in clinic.

Evaluation of usefulness of multi directional angles oblique scan method in optic nerve MRI (시각신경 MR 검사 시 다중 각도 스캔 기법의 유용성 평가)

  • Cho, Moo-Seong;Cho, Jae-Hwan;Bae, Jae-Yeong;Kim, Jeong-Soo;Kim, Kyeong-Keun
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.4
    • /
    • pp.161-169
    • /
    • 2011
  • This research experimented on the change of the multiple colleague scan angle facing one scan object facet to many directions of the form of 3D about the visual angle nervous system forming the cubic distribution with the gradient magnetic field of the mri system and considered the existing basic angle oblique direction test coverage and comparison. MR system can freely select various pulse sequence and image slice. To oblique imaging for optic nerve viewing, we have studied the variation of scan angle between typical oblique scan method (sagittal-coronal plane) and multi directional angles oblique scan method (sagittal-coronal-axial plane) using gradient of MR system. In this study, the subjects of the experiment were normal adults in our country. As a result, we confirmed that multi directional angles oblique scan method can display anatomical information of more wider area than typical oblique scan method. In addition, to clearly display optic nerve, we also confirmed that image slice thickness and pulse sequence have effect on it.

Introduction of Hindfoot Coronal Alignment View (후족부 관상면 배열 영상에 대한 고안)

  • Moon, Il-Bong;Jeon, Ju-Seob;Yoon, Kang-Cheol;Choi, Nam-Kil;Kim, Seung-Kook
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.225-228
    • /
    • 2006
  • Purpose: Accurate clinical evaluation of the alignment of the calcaneus relative to the tibia in the coronal plane is essential in the evaluation and treatment of hindfoot pathologic condition. Previously described standard anteroposterior, lateral, and oblique radiographic methods of the foot or ankle do not demonstrate alignment of the tibia relation to the calcaneus in the coronal plane. The purpose of this study was to introduce hindfoot coronal alignment view. Material : 1) Both feet were imaged simultaneously on an elevated, radiolucent foot stand equipment. 2) Both feet stood on a radiolucent platform with equal weight on both feet. 3) Both feet are located foot axis longitudinal perpendicular to the platform. 4) Silhouette tracing around both feet are made, and line is then drawn to bisect the silhouette of the second toe and the outline of the heel. 5) The x-ray beam is angled down approximately $15^{\circ} to $20^{\circ} Result : 1) This image described tibial axis and medial, lateral tuberosity of calcaneus. 2) Calcaneus do not rotated. 3) The view is showed by talotibial joint space. Conclusion: Although computed tomographic and magnetic resonance imaging techniques are capable of demonstrating coronal hindfoot alignment, they lack usefulness in most clinical situations because the foot is imaged in a non-weight bearing position. But hindfoot coronal alignment view is obtained for evaluating position changing of inversion, eversion of the hindfoot and varus, valgus deformity of calcaneus.

  • PDF