• Title/Summary/Keyword: 사고로부터 안전

Search Result 671, Processing Time 0.03 seconds

A Study on Software Implementation for Validation of Electronic Navigational Chart Regarding Standard Check for S-10X Data (S-10X 데이터 표준 검사를 위한 전자해도 검증 소프트웨어 구현에 관한 연구)

  • LEE, Ha-Dong;KIM, Ki-Su;CHOI, Yun-Su;KIM, Ji-Yoon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.21 no.1
    • /
    • pp.83-95
    • /
    • 2018
  • With recent technological advances in the shipbuilding industry, vessels have been improved in size and performance. As a result, an accident such as grounding, caused by a single ship-to-ship collision, could lead to a large-scale maritime disaster. Considering the seriousness of the situation, the international community has been consistently updating the standards for Electronic Navigational Chart(ENC) to improve the maritime safety. S-57, the existing ENC standard governed by the International Hydrographic Organization(IHO), includes standards for generating conventional binary-type ENC data sets. The S-57 standard, however, has not been updated since the release of Version 3.1 in December 2000. Since then, the standard has failed to reflect technological development regarding maritime spacial information, which has been consistently improving. In an effort to address this concern, the IHO designated S-100, i.e., the next-generation ENC production standard. S-100 differs from S-57 in data exchange type. Contrary to the conventional ENC standards, which use binary-type data, S-10X, based on the next-generation ENC standards, uses ENC data composed of Feature Catalogue, Portrayal Catalogue, and GML. Considering this fact, it is necessary to update S-58, the ENC validation check standard, or designate a new standard for ENC validation checks. This study is developed own software to implement validation checks for new types of data, and identified improvement points based on the test results.

Analysis of Contentment of Residential Environment among the Downtown Residents, the Aged: Taking Cheonan City for example (도심거주 고령자의 주거환경 만족도 분석: 천안시를 사례로)

  • Im, Jun-Hong
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.3
    • /
    • pp.114-122
    • /
    • 2015
  • This study aims to analyze the satisfaction of seniors living in Cheonan City downtown as to their residential environment. Also, this study intends to identify which factors should be improved first to make downtown a favorable residential area. To that end, 'social indicators of Chungnam' was used. The collected data was analyzed through a statistical analysis method using ANOVA (analysis of variance) and a cluster analysis. It led to the following findings. First, 6.9% of the elderly residents expressed their wish to move from their downtown residence. Thus, the majority of the residents do not want to move. Second, the satisfaction of the elderly residents in their downtown residence scored 6.09. The score is higher than those of other regions. Thus, it is highly possible to develop downtown into a senior-friendly area. Third, as for satisfaction in downtown residence, it was higher among the following groups: men; those with high school or higher level of education; those earning at least a million won a month; family of one generation. Fourth, satisfaction in the following factors was relatively low: culture and education; interaction with neighbors and trust in them; car accidents. Thus, those factors should be improved for downtown residents. Above all, community-faced facilities should be expanded to increase exchanges with neighbors and trust in them. To attract women dissatisfied with downtown residence. it is imperative to increase daily safety by reducing car accidents and crime.

A Study for Preventing Secondary Incident Caused by Incoincidence of Individual Flights PID values or Sensor or Telecommunication Defects During Formation Flying (쿼드콥터 편대비행 중 PID값 불일치 및 센서, 모듈 고장진단을 통해 2차사고 발생 방지를 위한 연구)

  • Kim, Hyo-jin;Lee, Kang-whan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.487-489
    • /
    • 2016
  • In this paper, quad copter provides a method for preventing the possibility of accident in the air during a formation flight. The existing studies had a few studies upon the falls because quad copter formation flight was generally implemented indoors. Therefore, in this paper, we provide a self-diagnosis system to prevent a secondary accident for mismatching the Proportional-Integral-Derivative(PID) and detecting an abnormal communication modules each others in formation flying system. Scheme to be proposed, a system is that when one of the node meets a problem, the header node is sending the information of the current state to the server in the first and making a diagnosis itself in order to avoid the problems caused by dropping from the air. Therefore, if the difference between PID value of header node and slave node is greater than specified values or if it detects a defective sensors and communication modules, the proposed system is set to provide for moving toward a safe place. As a result, we expect that this proposed system is possible to minimize additional incidents by self adjusting the height through a self-diagnosis discovering flawed the acceleration sensor, gyro sensor and various attached sensors.

  • PDF

Assessment of the MELCOR 1.8.6 condensation heat transfer model under the presence of noncondensable gases (중대사고 해석코드 MELCOR 1.8.6의 비응축성기체 존재 시 응축열전달 모델 평가)

  • Yoo, Ji Min;Lee, Dong Hun;Yun, Byong Jo;Jeong, Jae Jun
    • Journal of Energy Engineering
    • /
    • v.25 no.2
    • /
    • pp.1-20
    • /
    • 2016
  • A condensation heat transfer model is very important for the safety analysis of nuclear power plants. Especially, condensation under the presence of noncondensable gases (NCGs) is an important issue in nuclear safety because the presence of even a small quantity of NCGs in the vapor largely reduces the condensation rate. In this study, the condensation heat transfer model of the severe accident analysis code MELCOR 1.8.6 has been assessed using a set of condensation experiments performed under the thermal-hydraulic conditions similar to those inside a containment during design-basis accidents or severe accidents. Experiment conditions are categorized into 4 types according to the shape of the condensation surface: vertical flat plates, outer surface of vertical pipes, inner surface of vertical pipes, the inner surface of horizontal pipes. The results of the calculations show that the MELCOR code generally under-predicts the condensation heat transfer except the condensation on inner surface of vertical pipes.

Detection of The Real-time Weather Information from a Vehicle Black Box (차량용 블랙박스 영상에서의 실시간 기상정보 검지)

  • Kang, Ju-mi;Lee, Jaesung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.320-323
    • /
    • 2014
  • Today is going with the advancement of intelligent transportation systems and traffic environment and helping to provide safe and convenient service through a mobile device work with the popularization of the vehicle black box. The traffic flow by a variety of causes is constantly changing, it is often unable to prepare the driver, depending on external factors can not be controlled by the power of the public, leading to a major accident. The system needs to pass the real-time weather data in the inter-operator to prevent this. The proposed detection algorithm weather information delivered real-time weather information for this paper. The weather condition is detected by using the contrast between the histogram of the motion of the wiper and the clear day algorithm. In general, the wiper is worked in extreme weather conditions that will have a value different contrast due to rain or snow. Situation was considered clear, snowy conditions, such as using it on a rainy situation. First, designated as ROI (Region Of Interest) of the minimum area that can be detected in order to reduce the amount of calculation for the wiper, the wiper, which was detected through the operation of the threshold Thresholding the brightness of the vehicle wiper. In addition, we distinguish the value of each meteorological situation by using contrast. Results was obtained to 80% for the snow conditions, a rainy situation.

  • PDF

Learning from the USA's Single Emergency Number 911: Policy Implications for Korea (미국 긴급번호 911 운영시스템에 관한 연구: 긴급번호 실질적 통합을 위한 정책 시사점 제시 중심으로)

  • Kim, Hak-Kyong;Lee, Sung-Yong
    • Korean Security Journal
    • /
    • no.43
    • /
    • pp.67-97
    • /
    • 2015
  • In Korea, a single emergency number, such as 911 of the USA and 999 of the UK, does not exist. This issue became highly controversial, when the Sewol Ferry Sinking disaster occurred last year. So, the Korean government has planned to adopt a single emergency number, integrating 112 of the Police, 119 of the Fire and Ambulance, 122 of the Korean Coast Guard, and many other emergency numbers. However, the integration plan recently proposed by the Ministry of Public Safety Security seems to be, what is called, a "partial integration model" which repeals the 122 number, but still maintains 112, 119, and 110 respectively. In this context, the study looks into USA's (diverse) 911 operating system, and subsequently tries to draw general features or characteristics. Further, the research attempts to derive policy implication from the general features. If the proposed partial integration model reflects the policy implications, the model can virtually operate like the 911 system -i.e. a single emergency number system - creating inter-operability between responding agencies such as police, fire, and ambulance, even though it is not a perfect integration model. The features drawn are (1) integration of emergency call-taking, (2) functional separation of call-taking and dispatching, (3) integration of physical facilities for call-taking and dispatching, and (4) professional call-takers and dispatchers. Moreover, the policy implications derived from the characteristics are (1) a user-friendly system - fast but accurate responses, (2) integrated responses to accidents, (3) professional call-taking and dispatching & objective and comprehensive risk assessment, and finally (4) active organizational learning in emergency call centers. Considering the policy implications, the following suggestions need to be applied to the current proposed plan: 1. Emergency services' systems should be tightly linked and connected in a systemic way so that they can communicate and exchange intelligence with one another. 2. Public safety answering points (call centers) of each emergency service should share their education and training modules, manuals, etc. Common training and manuals are also needed for inter-operability. 3. Personal management to enable-long term service in public safety answering points (call centers) should be established as one of the ways to promote professionalism.

  • PDF

Assessment of Sanitary Management Practices of School Foodservice Operations in Seoul (서울지역 학교급식 위생관리 실태평가)

  • Kwak, Tong-Kyung;Hong, Wan-Soo;Moon, Hye-Kyung;Ryu, Kyung;Chang, Hye-Ja
    • Journal of Food Hygiene and Safety
    • /
    • v.16 no.3
    • /
    • pp.168-177
    • /
    • 2001
  • Sanitary management practices were assessed to insure the safety of school foodservice, to prevent the outbreak of foodborne illness, and to improve the quality of school foodservice. To accomplish these objectives, a survey was conducted and analyzed on elementary and high school foodservice operations located in Seoul area. A Questionnaire from based on HACCP standards was developed and used for self-reported evaluation of the school foodservice managers on their sanitary management practices. The results were analysed by examining their activities and identifying weaknesses in those activities. The questionnaire was composed of three sectors with all 53 questions; 33 questions for time-temperature management, 5 for personal hygiene and 15 for equipment/facility sanitation. Five-point-scale was used on the questionnaire answers. Among the schools responded,253 (98.4% of the total) were elementary schools and 19 (1.6%) were high schools. Among the three sectors, personal hygiene performance was mostly well conducted by marking average 4.06$\pm$0.57. Equipment/facility sanitation came next by marking average 3.84$\pm$0.53. Time-temperature marked average 3.45$\pm$0.46. “Storage after cooking (2.03$\pm$0.94)”was identified as the least managed activities because the school foodservice operations were not equipped well with hot holding and/or cold holding. “Separate use of sink per usage (3.03$\pm$1.10)” and “proper location of hand washing facility (3.07$\pm$1.13))” were identified as the least practiced activities in equipment/facility sanitation sector. To enhance these practices, proper number of sinks and hand washing facilities should be equipped first within the kitchen area.

  • PDF

A Study on Radiation Safety Evaluation for Spent Fuel Transportation Cask (사용후핵연료 운반용기 방사선적 안전성평가에 관한 연구)

  • Choi, Young-Hwan;Ko, Jae-Hun;Lee, Dong-Gyu;Jung, In-Su
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.4
    • /
    • pp.375-387
    • /
    • 2019
  • In this study, the radiation dose rates for the design basis fuel of 360 assemblies CANDU spent nuclear fuel transportation cask were evaluated, by measuring radiation source terms for the design basis fuel of a pressurized heavy water reactor. Additionally, radiological safety evaluation was carried out and the validity of the results was determined by radiological technical standards. To select the design basis fuel, which was the radiation source term for the spent fuel transportation cask, the design basis fuels from two spent fuel storage facilities were stored in a spent fuel transportation cask operating in Wolsung NPP. The design basis fuel for each transportation and storage system was based on the burnup of spent fuel, minimum cooling period, and time of transportation to the intermediate storage facility. A burnup of 7,800 MWD/MTU and a minimum cooling period of 6 years were set as the design basis fuel. The radiation source terms of the design basis fuel were evaluated using the ORIGEN-ARP computer module of SCALE computer code. The radiation shielding of the cask was evaluated using the MCNP6 computer code. In addition, the evaluation of the radiation dose rate outside the transport cask required by the technical standard was classified into normal and accident conditions. Thus, the maximum radiation dose rates calculated at the surface of the cask and at a point 2 m from the surface of the cask under normal transportation conditions were respectively 0.330 mSv·h-1 and 0.065 mSv·h-1. The maximum radiation dose rate 1 m from the surface of the cask under accident conditions was calculated as 0.321 mSv·h-1. Thus, it was confirmed that the spent fuel cask of the large capacity heavy water reactor had secured the radiation safety.

Simulation Analysis on Passengers' Normal Evacuation Scenarios Considering the Changes of Heeling Angle during MV Sewol's Sinking (세월호 침몰시의 힐링각변화 조건에서 승객의 정상적인 탈출시나리오에 관한 시뮬레이션 분석)

  • Hwang, Kwang-Il
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.1
    • /
    • pp.47-56
    • /
    • 2015
  • Under the conditions of invested actual changes of heeling angles during MV Sewol's sinking, this study proposes passengers' evacuation scenarios, which are based on the assumption of normal orders of evacuation being given to the passengers, and evaluates using a marine-specialized human evacuation simulation tool. As results, when the heeling angle is set as 0 degree or 30 degree, it is found out that almost every passengers can success to evacuate to the musterstations, even though the evacuation times are different depending on the scenarios and the walking speeds. Meanwhile, when the heeling angle is varied as the Sewol incident, 3.1 %(Scenario Sc-Va which set chutes on port side as evacuation routes), 11.1 %(Sc-Vb, every open decks of port side as evacuation routes) and 20.0 %(Sc-Vc, every open decks of port and AFT sides as evacuation routes) among 476 passengers can successfully reach to the musterstations from their cabins with the condition of average walking speed as 2.04 m/s on flat. And only 0.8 %(Sc-Va), 3.8 %(Sc-Vb) and 10.7 %(Sc-Vc) can success to evacuate with the condition of average walking speed as 1.48 m/s on flat.

Excess Flow Valves for Underground Gas Pipeline and their Performance Testing Equipment Development (연료가스 매몰배관용 과류차단밸브와 성능시험 장치 개발)

  • Lee, Ugwiyeon;Joo, Yukyung;Lee, Jinhan
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.74-81
    • /
    • 2018
  • The Korean Government has proceeded petroleum gas pipeline construction business since 2014 for rural districts. The operating pressure of petroleum gas pipeline are from 25kPa to 75kPa which are different from that of natural gas pipeline. Petroleum gas pipeline pressure is ten or forty times higher than natural gas operating pressure. For this reason, petroleum gas pipeline has higher probability of accident occurrence from massive gas leakage. Korea Gas Safety Corporation begins to development excess flow valves and their performance testing equipment since 2017. The excess flow valves stop the gas flow when a overflow happened in gas pipeline. The excess flow valves are generally not installed in main pipeline, because that may block massive gas supply. So, the valves are installed in starting points of branch pipes. According to the number of house and amount of gas use, a shut-off point of exxcess flow valve is determined called as Trip Flow. The trip point is the most important thing of excess flow valve, so, it is required a equipment testing the performances of excess flow valve as trip point.