• Title/Summary/Keyword: 사각주 후류

Search Result 10, Processing Time 0.018 seconds

Passive Control of the Vortex Shedding behind a Rectangular Cylinder Near a Wall (벽면에 근접한 사각주 후면의 와류 유동장 수동제어)

  • Lee, Bo-Sung;Kim, Tae-Yoon;Lee, Do-Hyung;Lee, Dong-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.6
    • /
    • pp.16-22
    • /
    • 2004
  • Unsteady vortex shedding behind a rectangular cylinder near a wall influences both increasing of drag and dynamic stability of heavy vehicle, bridge or building. Incompressible Averaged Navier-Stokes equation with modified ${\varepsilon}-SST$ turbulence model is adapted for investigating the flow field between the rectangular cylinder and the wall. In case the vortex shedding happens, not only the averaged maximum velocity is higher than other cases, but the position of the maximum velocity is closer to the lower surface of rectangular cylinder. On this study, it is confirmed that the vortex shedding behind a rectangular cylinder can be suppressed by the passive control method added by horizontal and vertical fences to the lower surface of rectangular cylinder.

Influence of the Wake Behind Rectangular Bars on the Flow and Heat Transfer in the Linear Turbine Cascade (사각주 후류가 선형터빈익렬의 유동 및 열전달에 미치는 영향에 관한 연구)

  • Yoon, Soon Hyun;Sim, Jae Kyung;Woo, Chang Soo;Lee, Dae Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.7
    • /
    • pp.864-870
    • /
    • 1999
  • An experimental study Is conducted in a four-vane linear cascade in order to examine the influence of the wake behind rectangular bars on the flow and heat transfer characteristics. Flow and heat transfer measurements are made for the inlet Reynolds number of 66000(based on chord length and free-stream velocity). Turbulent intensity and stress are measured using a hot-wire anemometer, and to measure the convective heat transfer coefficients on the blade surface liquid crystal/gold film Intrex technique is used. Each of experimental cases is characterized by the unsteadiness measured at the entrance of the cascade. The wake behind the rectangular bars enhances the turbulent motion of the flow in the cascade passage. It also promotes the boundary layer development and transition. The results show that heat transfer coefficients on the blade surface increase with increasing unsteadiness.

A Study on Wake Flow Characteristics of vertical Plate with Various Coner Shape (모서리 형상에 따른 수직벽 후류특성에 관한 연구)

  • Lee, Cheol-Jae;Cho, Dae-Hwan
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.2
    • /
    • pp.101-106
    • /
    • 2011
  • In this study, the velocity distribution according to upper side coner shape of underwater construction with rectangular cylinder was measured with PIV method and the wake flow characteristics was considered. According to the coner shape, the flow pattern of wake flow was also differed greatly and the step-shaped coner of cut-off ratio B/H=0.06 was similar in the slope shape in result.

Passive Control of the Vortex Shedding past a Square Cylinder with Moving Ground Part II Study of Passive Control Technique (지면 운동에 따른 정사각주 후류의 와류 유동장 수치 해석 Part II. 수동 제어 기법 연구)

  • Kim, Tae-Yoon;Lee, Bo-Sung;Lee, Dong-Ho;Kohama, Y.
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.6
    • /
    • pp.8-14
    • /
    • 2005
  • Understanding of the flow past a bluff body close to a moving ground is very important in automobile and aeronautical fields because of aerodynamic characteristic and instability induced by unsteady vortex shedding. The passive control method that mounted the vertical and horizontal plates at the lower surface of the cylinder is studied to suppress the unsteady oscillation motion. When the grounds moves, the diminish of the shear layer on the ground promotes the interaction between the lower and the upper separated shear layers of the cylinder, hence vortex shedding occurs at the lower gap height than the stationary ground.

A Study on the Flow Control in a Wide Angle Diffuser by Installation of a Rectangular Prism (광각디퓨저의 내부에 설치된 장방형 각주를 이용한 유동제어에 관한 연구)

  • Lee, Cheol-Jae;Cho, Dae-Hwan
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.57-62
    • /
    • 2011
  • In this study, a experimental work to investigate the influence of a turbulent wake flow on the velocity distribution of a diffuser with PIV method. The turbulent wake is generated by a rectangular prism, which is installed at the inlet of a diffuser. The results show that the velocity recovery of the subsonic diffuser is dependent on the height and location of rectangular prism. It is found that a certain height of the rectangular prism to generate the turbulent wake give a better velocity recovery, compared with no rectangular prism.

The Flow Control by a Vertical Splitter Plate for a Square Prism near a Wall (벽면 근처에 놓인 정방형주의 수직 분할판에 의한 유동 제어)

  • Ro, Ki-Deok;Cho, Ji-Ryong;Oh, Se-Kyung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.94-100
    • /
    • 2012
  • The passive control by vertical splitter plate of fluid force acting on a square prism near a plane wall was studied by measuring of fluid force on the prism and by visualization of the flow field using PIV. The hight of the splitter plate was 10% of the square width. The experimental parameters were the attaching position of vertical splitter plate and the space ratios G/B to the prism height. Time variation of vorticity was most remarkable at 3.0B(B: prism height) position toward wake direction from the center of the prism. The point of inflection of average lift coefficient and Strouhal number on the prism were represented at the space ratio G/B=0.4~0.6 for the prism having vertical splitter plate. The drag of the prism was reduced average 5.0% with the space ratios by attaching the vertical splitter plate at the upper and rear corner on the prism. In this case, the size of the separated region on the upside of the prism was smaller than that of prism having no the splitter plate.

Numerical Analysis of the Vortex Shedding past a Square Cylinder with Moving Ground (지면 운동에 따른 정사각주 후류의 와류 유동장 수치 해석 Part I. 고정 지면과 이동 지면 비교)

  • Kim, Tae-Yoon;Lee, Bo-Sung;Lee, Dong-Ho;Kohama, Y.
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.6
    • /
    • pp.1-7
    • /
    • 2005
  • Incompressible Reynolds-averaged Navier-Stokes equations with $\varepsilon{-SST}$ turbulence model are adopted for the investigation of the flow fields between the square cylinder and the ground. When the grounds moves, the diminish of the shear layer intensity on the ground promotes the interaction between the lower and the upper separated shear layer of the cylinder. Hence vortex shedding occurs at the lower gap height than stationary ground. In the moving ground, the secondary shedding frequency disappears due to the absence of the separation bubble on the ground which exists in the stationary ground. In addition, the shedding frequency and aerodynamic coefficients in the moving ground become higher than those of the stationary ground.

The characteristic of bluff body stabilized flames for simulation of engine nacelle fires (엔진나셀화재 모사를 위한 둔각물체 안정화 화염 특성)

  • Lee, Jung-Ran;Lee, Eui-Ju
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.58-61
    • /
    • 2012
  • 엔진나셀 화재를 둔각물체에서 분사된 연료제트 화염으로 모사하여 화염안정화 및 소화특성을 조사하기 위해 실험과 수치해석을 수행하였다. 연료제트는 공기유동에 동측류인 경우와 대향류인 경우에 사각의 둔각물체에서 분사하였고, 소화약제는 이산화탄소와 질소를 사용하여 공기유동에 희석시켜주었으며 연료로는 메탄을 사용하였다. 본 실험의 결과를 해석하고 보충하기 위하여 LES(Large Eddy Simulation)을 기반으로 하는 FDS(Fire Dynamics Simulator)를 이용하여 비반응 유동장에서의 혼합특성과 둔각물체 후류의 유동특성을 살펴보았다.

  • PDF

Numerical Study on the Reacting Flow Field abound Rectangular Cross Section Bluff Body (사각 둔각물체 주위의 반응유동장에 대한 수치적 연구)

  • Lee, Jung-Ran;Lee, Eui-Ju
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.64-69
    • /
    • 2013
  • The Numerical simulation was performed on the flow field around the two-dimensional rectangular bluff body in order to simulate an engine nacelle fire and to complement the previous experimental results of the bluff body stabilized flames. Fire Dynamic Simulator (FDS) based on the Direct Numerical Simulation (DNS) was employed to clarify the characteristics of reacting flow around bluff body. The overall reaction was considered and the constant for reaction was determined from flame extinction limits of experimental results. The air used atmosphere and the fuel used methane. For both fuel ejection configurations against an oxidizer stream, the flame stability and flame mode were affected mainly by vortex structure near bluff body. In the coflow configuration, air velocity at the flame extinction limit are increased with fuel velocity, which is comparable to the experiment results. Comparing with the isothermal flow field, the reacting flow produces a weak and small recirculation zone, which is result in the reductions of density and momentum due to temperature increase by reaction in the wake zone.

The Flow Control by a Horizontal Splitter Plate for a Square Prism near a Wall (벽면에 근처에 놓인 정방형주의 수평 분리판에 의한 유동 제어)

  • Ro, Ki-Deok;Lee, Sang-Jun;Lee, Gyeong-Yun;Jang, Jae-Dong;Jung, Yong-Gil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.625-631
    • /
    • 2011
  • The passive control of fluid force acting on a square prism near a plane wall was studied by attaching horizontal splitter plate on the corner of the prism. The width of the splitter plate was 10% of the square width. The experiments were performed by measuring of fluid force on the prism and by visualization of the flow field using PIV. The experimental parameters were the attaching position and the space ratios G/B between the prism and wall. The flow between the prism and wall was remarkable and Karman vortex in the wake of the prism was considerable in the space ratio over 0.4. The point of inflection of average lift coefficient and Strouhal number on the prism were represented at the space ratio G/B=0.4 for the prototype prism and G/B=0.6 for the prism having horizontal splitter plate. The drag of the prism was reduced average 4.5% with the space ratios by attaching the horizontal splitter plate at the rear and lower corner on the prism. In this case, the size of the separated region on the upside of the prism was smaller than that of prism without the splitter plate.