An Experimental Study on the Thermal Characteristics of Ice Storage Tank - Focusing on the Adiabatic Effects of Ice Storage Tank - (직접접촉식 빙축열조의 전열특성에 관한 연구 - 빙축열조의 단열영향을 중심으로 -)

  • Lee, Chae-Moon;Park, Jung-Won;Cho, Nam-Chul;Park, Sang-Rok;Kim, Il-Gyoum;Kim, Dong-Chun;Kim, Young-Ki;Yim, Chang-Soon
    • Solar Energy
    • /
    • v.17 no.2
    • /
    • pp.75-89
    • /
    • 1997
  • In this paper, the operating thermal characterictics of liquid-ice was expeimentally investigated in an adiabatic and a non-adiabatic direct contact liquid-ice heat exchanger. Experiments were carried out varing inlet temperature, Ice Packing Factor, and the flow rate of heat transfer fluid. The higher inlet temperature and the more much inlet flow rate, thermal stratification in liquid-ice heat exchanger was established faster. In the case of adiabatic ice storage tank, temperature distribution was a little higher at all conditions than that of non-adiabatic one. The ratio of latent energy to total discharge energy($E_{\lambda}/E_[tot}$) was about 80%, and the discharge of latent heat energy was appeared rapidly as inlet temperature and flow rate were higher.

  • PDF

An Experimental Study on the Thermal Characteristics of Direct Contact Liquid-Ice Heat Exchanger (직접접촉식 액-빙 열교환기의 전열특성에 관한 실험적 연구)

  • Lee, Chae-Moon;Park, Jung-Won;Kim, Dong-Hun
    • Solar Energy
    • /
    • v.16 no.2
    • /
    • pp.65-77
    • /
    • 1996
  • The operating thermal chracteristics of direct contact liquid-ice heat exchanger was experimentally investigated. In this paper, The effects of Ice Packing Factor(IPF), the inlet temperature and the flow rate of Heat Transfer Fluid(HTF) were stuided in the liquid-ice heat exchanger. Thermal stratification in liquid-ice heat exchanger was established clearly and faster at the higher inlet temperature and flow rate of HTF. At the end of melting of the lower flow rate is cleared the thermal stratification in liquid-ice heat exchanger. The temperature stratification is long with higher value of IPF of liquid-ice heat exchanger. The mean temperature of liquid-ice storage was changed rapidly with increasing flow rate and inlet temperature of HTF. The gradiant of ratio of total energy to latent energy was found higher with increasing inlet temperature and flow rate.

  • PDF

A Study on the Effect of Surfactant on the Freezing of Aqueous Solution (수용액의 동결에 영향을 미치는 계면활성제의 효과에 관한 연구)

  • Kim, Myoung-Jun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.694-698
    • /
    • 2007
  • This present study has dealt with the effect of surfactant on the freezing of aqueous solution Sodium chloride aqueous solution was used to measure the effect of surfactant and the main parameters of this experiment were temperature of bath, revolution of stirrer. and the radial velocity of NaCl solution. The acquired main conclusions are as follows; 1) the lower super-cooling temperature make hardly to attach the ice on beaker, 2) the size of ice become smaller to add the surfactant, 3) the ice packing factor increase with increasing of stirrer revolution.

A study on formation of slurry ice by the reversing flow (역전 유동층에 의한 슬러리아이스 생성에 관한 연구)

  • Oh, C.;Mun, S.B.;Choi, Y.G.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.3
    • /
    • pp.376-381
    • /
    • 2006
  • This study is experimented to observe an influence of experimental conditions on production characteristics of slurry ice by putting ball into test section to disturb ice adhesion. And at this experiment it used ethylene glycol-water solution and the concentration is 20wt%. The experimental apparatus was constructed of ethylene glycol-water solution and slurry ice storage tank. brine tank, pumps for ethylene glycol-water solution and brine circulating, a mass flow-meter data logger for fluid temperature measuring and a vertical circular tube with two copper tubes as test section. The experiments were carried out under various conditions, with mean velocity of fluid at the entry ranging from 0.07 to 0.13m/s and ball diameter is 10mm, 15mm. Also ball filling rate is 33%, 50%.

An experimental study on ice slurry fluid and pressure drop characteristics in along a horizontal circular tube around the valve (배관 내 밸브 주위의 아이스슬러리의 유동현상 및 압력강하특성에 관한 연구)

  • Oh, C.;Mun, S.B.;Son, Y.G.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.3
    • /
    • pp.382-388
    • /
    • 2006
  • This study experimented to understand the effect of transporting ice slurry through in pipe with valve. And at this experiment it used ethylene glycol-water solution and a concentration is 30wt%. The experimental apparatus was constructed of ice slurry generation tank, turbo flow meter, manometers for differential pressure measuring, PIV system for flow pattern measuring. illumination and along a horizontal circular tube with valve as test section. The experiments were carried out under various conditions, with velocity of fluid at the entry ranging from 0.5 to 1.5 m/s and concentration of IPF is 30%. Also valve open rate is 50%, 75%, 100%.