• Title/Summary/Keyword: 빔 차폐

Search Result 40, Processing Time 0.03 seconds

Development of Manual Multi-Leaf Collimator for Proton Therapy in National Cancer Center (국립암센터의 양성자 치료를 위한 수동형 다엽 콜리메이터 개발)

  • Lee, Nuri;Kim, Tae Yoon;Kang, Dong Yun;Choi, Jae Hyock;Jeong, Jong Hwi;Shin, Dongho;Lim, Young Kyung;Park, Jeonghoon;Kim, Tae Hyun;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.250-257
    • /
    • 2015
  • Multi-leaf collimator (MLC) systems are frequently used to deliver photon-based radiation, and allow conformal shaping of treatment beams. Many proton beam centers currently make use of aperture and snout systems, which involve use of a snout to shape and focus the proton beam, a brass aperture to modify field shape, and an acrylic compensator to modulate depth. However, it needs a lot of time and cost of preparing treatment, therefore, we developed the manual MLC for solving this problem. This study was carried out with the intent of designing an MLC system as an alternative to an aperture block system. Radio-activation and dose due to primary proton beam leakage and the presence of secondary neutrons were taken into account during these iterations. Analytical calculations were used to study the effects of leaf material on activation. We have fabricated tray model for adoption with a wobbling snout ($30{\times}40cm^2$) system which used uniform scanning beam. We designed the manual MLC and tray and can reduce the cost and time for treatment. After leakage test of new tray, we upgrade the tray with brass and made the safety tool. First, we have tested the radio-activation with usually brass and new brass for new manual MLC. It shows similar behavior and decay trend. In addition, we have measured the leakage test of a gantry with new tray and MLC tray, while we exposed the high energy with full modulation process on film dosimetry. The radiation leakage is less than 1%. From these results, we have developed the design of the tray and upgrade for safety. Through the radio-activation behavior, we figure out the proton beam leakage level of safety, where there detects the secondary particle, including neutron. After developing new design of the tray, it will be able to reduce the time and cost of proton treatment. Finally, we have applied in clinic test with original brass aperture and manual MLC and calculated the gamma index, 99.74% between them.

Application of the Radar Rainfall Estimates Using the Hybrid Scan Reflectivity Technique to the Hydrologic Model (Hybrid Scan Reflectivity 기법을 이용한 레이더 강우량의 수문모형 적용)

  • Lee, Jae-Kyoung;Lee, Min-Ho;Suk, Mi-Kyung;Park, Hye-Sook
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.10
    • /
    • pp.867-878
    • /
    • 2014
  • Due to the nature of weather radar, blank areas occur due to impediments to observation, such as the ground clutter. Radar beam blockages have resulted in the underestimation rainfall amounts. To overcome these limitations, this study developed the Hybrid Scan Reflectivity (HSR) technique and compared the HSR results with existing methods. As a result, the HSR technique was able to estimate rainfalls in areas from which no reflectivity information was observable using existing methods. In case of estimating rainfalls depending on reflectivity scan techniques and beam-blockage/non beam-blockage, the HSR accuracy is superior. Furthermore, rainfall amounts derived from each method was inputted to the HEC-HMS to examine the accuracy of the flood simulations. The accuracy of the results using the HSR technique in contrast to the RAR calculation system and M-P relation was improved by 7% and 10%(based on correlation coefficients), and 18% and 34%(based on Nash-Sutcliffe Efficiency), on average, respectively. Therefore, it is advised that the HSR technique be utilized in the hydrology field to estimate flood discharge more accurately.

The Assessment of Scattered Ray According to the Beam Thickness of Z-axis in MDCT(Multi Detector Computed Tomography) (MDCT(다배열검출기 전산화단층촬영장치)에서 Z-축의 빔 두께에 따른 산란선의 평가)

  • Ryu, Gwi-Bok;Kim, Hyun-Soo;Lyu, Kwang-Yeul;Dong, Kyung-Rae;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.127-132
    • /
    • 2010
  • The purpose of this study is to measure scattered ray which is occurred except for Z-axis range of the detector in MDCT's iso-center and present the basic data about the standard for reduction of scattered ray. The development of MDCT brings out the enlargement of beam thickness to the patient's Z-axis, which distributes to the increase in exposure dose according to the rise of scattered ray. Also MDCT brings out the increase of scattered ray about 4times more than SDCT. To evaluate scattered ray according to the change of beam thickness on MDCT, we measured scattered ray of MDCT's Z-axis beam thickness by using one 16-slice CTs and two 64-slice CTs. We used the ionization chamber 60ml 2026C as the equipment of measurement. In our results, we found out that the change of scattered ray according to the beam thickness in the same kVp has increase of scattered ray. Secondly we found out the increase of scattered ray according to the increase of kVp. Lastly we found out the decrease of scattered ray according to the increase of the distance from the ionization chamber.

The Analysis and Development of Electron Beam Filament (전자빔 필라멘트의 해석 및 개발)

  • Lee, Jeong-Ick;Lee, Eung-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2008.05a
    • /
    • pp.43-45
    • /
    • 2008
  • 박막 제작공정은 반도체 제작 공정, 고정밀도의 하드디스크 및 레이저 디스크 기술, LCD/P에 DML평판 디스크 플레이어 제작 공정에 있어 중요한 기술이다. 더욱이, 이 공정은 이동 전화 커버의 증착 및 전자 차폐의 일반기술, 램프의 반사판, 화장품 용기, 몇몇 상품에 있어 카메라 렌즈의 광학 표면 코팅과 코팅 필름 제작에 사용된다. 본 연구의 주요목적은 반도체 제작 공정과 많은 산업 분야에서 기본 재료로 사용되는 전영저항의 개발에 있다. 개발 공정은 다음과 같다. 전자빔이 최상의 진공 분위기에서 텅스텐 필라멘트의 열에 의해 방출된다. 그때 전자는 높은 전압에서 가속화된다. 전자들은 반대 재료에 충돌되고, 반대편 재료는 발생 열에 의해 코팅된다. 1차년도 연구목적은 고성능 전열 저항체 개발을 위한 지름 당 필라멘트 선의 기계적 특성을 조사하고 CAE 해석을 수행하며, 2차 년도에는 대량 생산 라인 구축을 위한 자동검사 라인 개발에 초점이 맞추어져 있다. 만일, 본 연구를 통해 전열 저항체가 개발된다면, 그 제품은 고효율, 외국제품 대비 가격 경쟁력을 가지므로 제품 경쟁력을 가질 수 있을 것으로 생각된다.

  • PDF

Research on Radiation Shielding Film for Replacement of Lead(Pb) through Roll-to-Roll Sputtering Deposition (롤투롤 스퍼터링 증착을 통한 납(Pb) 대체용 방사선 차폐필름 개발)

  • Sung-Hun Kim;Jung-Sup Byun;Young-Bin Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.441-447
    • /
    • 2023
  • Lead(Pb), which is currently mainly used for shielding purposes in the medical radiation, has excellent radiation shielding functions, but is continuously exposed to radiation directly or indirectly due to the harmfulness of lead itself to the human body and the inconvenience caused by its heavy weight. Research on shielding materials that are human-friendly, lightweight, and convenient to use that can block risks and replace lead is continuously being conducted. In this study, based on the commonly used polyethylene terephthalate (PET) film and the fabric material used in actual radiation protective clothing, a multi-layer thin film was realized through sputtering and vacuum deposition of bismuth, tungsten, and tin, which are metal materials that can shield radiation. Thus, a shielding film was produced and its applicability as a radiation shielding material was evaluated. The radiation shielding film was manufactured by establishing the optimized conditions for each shielding material while controlling the applied voltage, roll driving speed, and gas supply amount to manufacture the shielding film. The adhesion between the parent material and the shielding metal thin film was confirmed by Cross-cut 100/100, and the stability of the thin film was confirmed through a hot water test for 1 hour to measure the change of the thin film over time. The shielding performance of the finally realized shielding film was measured by the Korea association for radiation application (KARA), and the test conditions (inverse wide beam, tube voltage 50 kV, half layer 1.828 mmAl) were set to obtain an attenuation ratio of 16.4 (initial value 0.300 mGy/s, measured value 0.018 mGy/s) and damping ratio 4.31 (initial value 0.300 mGy/s, measured value 0.069 mGy/s) were obtained. by securing process efficiency for future commercialization, light and shielding films and fabrics were used to lay the foundation for the application of films to radiation protective clothing or construction materials with shielding functions.

A Study on the Lead(Pb) Shield Thickness per Electron Beam Energy in Radiotherapy (방사선 치료용 전자선의 에너지별 납(Pb) 차폐체 두께 측정)

  • Gha-Jung, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.719-725
    • /
    • 2022
  • This study aimed to measure, quantitatively evaluate, and set the criteria for the minimum lead(Pb) shield thickness per level of clinically applied electron beam energy. The lead shield thickness per electron beam energy was measured using the primary field 95% reduction based on the open field at the depth of maximum dose (dmax) and depth from the surface as the reference depth of tissue dose(10 mm). The measured values were 1.906 mmPb and 1.992 mmPb at the dmax and 10 mm, respectively, regarding the lead shield thickness for 6 MeV electron beam; 2.746 mmPb and 3.743 mmPb for 9 MeV electron beam, 3.718 mmPb and 6.093 mmPb for 12 MeV electron beam, 7.300 mmPb and 15.270 mmPb for 16 MeV electron beam, and 16.825 mmPb and 25.090 mmPb for 20 MeV electron beam. Consequently, a thicker lead shield was required if the measurement was at 10 mm. The required lead shield thickness was also higher than that of the theoretical formula for electron beams of ≥ 16 MeV.

Accuracy Evaluation of Composite Hybrid Surface Rainfall (HSR) Using KMA Weather Radar Network (기상청 기상레이더 관측망을 이용한 합성 하이브리드 고도면 강우량(HSR)의 정확도 검증)

  • Lyu, Geunsu;Jung, Sung-Hwa;Oh, Young-a;Park, Hong-Mok;Lee, GyuWon
    • Journal of the Korean earth science society
    • /
    • v.38 no.7
    • /
    • pp.496-510
    • /
    • 2017
  • This study presents a new nationwide quantitative precipitation estimation (QPE) based on the hybrid surface rainfall (HSR) technique using the weather radar network of Korea Meteorological Administration (KMA). This new nationwide HSR is characterized by the synthesis of reflectivity at the hybrid surface that is not affected by ground clutter, beam blockage, non-meteorological echoes, and bright band. The nationwide HSR is classified into static (STATIC) and dynamic HSR (DYNAMIC) mosaic depending on employing a quality control process, which is based on the fuzzy logic approach for single-polarization radar and the spatial texture technique for dual-polarization radar. The STATIC and DYNAMIC were evaluated by comparing with official and operational radar rainfall mosaic (MOSAIC) of KMA for 10 rainfall events from May to October 2014. The correlation coefficients within the block region of STATIC, DYNAMIC and MOSAIC are 0.52, 0.78, and 0.69, respectively, and their mean relative errors are 34.08, 30.08, and 40.71%.

Spinal Cord Partial Block Technique Using Dynamic MLC (동적 다엽콜리메이터를 이용한 척수의 부분 차폐 기법)

  • 조삼주;이병용;이상욱;안승도;김종훈;권수일;최은경
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.8-14
    • /
    • 2003
  • The spinal cord dose is the one of the limiting factor for the radiation treatment of the head & neck or the thorax region. It is not an easy task to maintain the spinal cord dose below tolerance and to keep the clinically acceptable dose to the PTV in this region. To overcome this problem, the spinal cord partial block technique (PBT) with the dynamic Multi-Leaf Collimator (dMLC) has been developed. This technique is an extension of the conventional treatment planning. In the beginning the beam directions are selected as same as the conventional treatment planning to encompass the PTV, then the partial block are designed to shield the spinal cord. The plan comparisons between the conventional therapy plan and the PTB plan were performed to evaluate the validity of this technique. The mean dose and the dose volume histogram (DVH) were used as the plan comparison indices. A series of quality assurance (QA) was performed to guarantee the reliable treatment. The QA consisted of the film dosimetry for the verification of the dose distribution and the point measurements. The PBT plan generated better results than the conventional treatment plan and it was proved to be useful for the H&N region.

  • PDF

Design of a 1 × 2 Array Microstrip Antenna for Active Beam Compensation at X-band (X-밴드 능동적 빔 보상 1 × 2 배열 마이크로스트립 안테나 설계)

  • Choi, Yoon-Seon;Woo, Jong-Myung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.2
    • /
    • pp.111-118
    • /
    • 2016
  • This paper presents an X-band (9.375 GHz) $1{\times}2$ array microstrip antenna which is capable of active beam compensation for installation of an unmanned aerial vehicle (UAV). First of all, a basic $1{\times}2$ array microstrip antenna incorporated with wilkinson power divider was designed and performance of the array antenna was verified. Next, to verify beam steering performance of the designed array microstrip antenna, we fabricated a phase shifter, and the wilkinson power divider as module structure and measured characteristics of beam steering according to phase shifting. The main lobe is 0.6 dBi at $0^{\circ}$, and the side lobe decreased 18.8 dB. The reliable radiation pattern was achieved. Finally, an active beam steering microstrip array antenna attached with the phase shifter and the power divider on the back side of the antenna was designed and fabricated to install wing of UAV for compactness. The maximum gain is 0.1 dBi. Therefore, we obtained a basic antenna technology for compensating beam error according to wing deformation of an UAV installed array antennas.

Selective Beam Shielding Method of Gamma-Knife Unit Using Various Plugging Patterns (다양한 Plugging 형태를 이용한 감마나이프의 선택적 빔 차폐 방법)

  • Jang Geon Ho;Lim Young Jin;Shin Dong Oh;Choi Doo Ho;Hong Seong Eon;Leem Won
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.439-448
    • /
    • 1993
  • The B-type gamma knife unit was installed at Kyung-Hee University Hospital in March 1992. The selective beam plugging method can be used to reduce the low percentage isodose profiles of normal sensitive organ and to modify the isodose curves of treatment volume for better shaping of the target volume. For representing the changes of the low percentage isodose profiles, the variations of dose distribution for several cases were discussed in this paper. The film dosimetry was peformed for the evaluation of calculated isodose profiles predicted by KULA dose planning system. The results were verified by RFA-3 automatic densitometry. The clinical application of selective beam shielding method was peformed in 17 patients in 100 patients who have undergone gamma knife radiosurgery for a year. The calculated and the measured isodose profiles for the high percentage regions were well consistent with each other. When the target of pituitary tumor is macro-size, the selective beam shielding method is the most applicable method. When the target size, however, is small, the correct selection of the proper helmet size is very important. All patients were exposed almost about 3~12 Gy for brain stem, and 3~11.2 Gy for optic apparatus. It is recommended that the same or other plugging patterns with multiple isocenters should be used for protection of the radiosensitive normal structures with precise treatment of CNS lesions.

  • PDF