• Title/Summary/Keyword: 비 파괴 검사

Search Result 110, Processing Time 0.022 seconds

Comparison of Yield, Physico-chemical and Sensory Characteristics for Chicken Surimi Manufactured by Alkaline Adjustment with Different Raw Materials (원료육 종류에 따라 알칼리 조절법으로 제조한 계육 수리미의 수율, 이화학적 및 관능적 특성 비교)

  • Jin, Sang-Keun;Kim, Il-Suk;Kim, Dong-Hoon;Jeong, Ki-Jong;Choi, Yeung-Joon
    • Food Science of Animal Resources
    • /
    • v.26 no.4
    • /
    • pp.431-440
    • /
    • 2006
  • This study was carried out to compare of yield, physico-chemical and sensory characteristics for chicken surimi manufactured by alkaline (pH 11) adjustment with different raw materials. Four experimental groups were surimi with chicken breast (T1) and chicken leg (T2) by spent hen, SF-MDCM (T3) and JY-MDCM (T4). Yield was higher in order of T1>T2>T3>T4 (p<0.05). The yield, physico-chemical and sensory characteristics of T1 were significantly higher than those of other treatments. Especially, $L^*$ and W value, shear force, textural properties, folding test, breaking force, gel strength, breaking $force{\times}deformation$, flavor, color and overall acceptability were higher in T1 but ar value, cooking loss, collagen and myoglobin content of T1 were lower than those of other treatments (p<0.05). Deformation, aroma, juiciness, tenderness were higher but met-myoglobin and yield of T4 were lower than those of T2 and T3 (p<0.05). Crude fat cooking loss and met-myoglobin content were higher in T2 but $b^*$ value, brittleness, hardness, gumminess, chewiness, folding test, breaking $force{\times}deformation$ and aroma of T2 were lower than those of other treatments (p<0.05). pH, collagen and moisture content and br value were higher but crude protein, folding test, $L^*$ and W value, cohesiveness, tenderness of T3 were lower than those of other treatmene (p<0.05). Correlation coefficients (r>0.8) between folding test and other items was positive in crude protein $L^*$ value, shear force and cohesiveness but negative in moisture content (p<0.05).

Survey of Unexpected Antibodies Identified at a General Hospital in Jeju (제주지역 일개 종합병원에서 동정된 비예기항체의 실태조사)

  • Chong, Moosang;Lee, Kyu-taeg;Cho, Young-Kuk
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.390-394
    • /
    • 2017
  • Unexpected antibody screening and identification tests are highly important in the prevention of hemolytic transfusion reactions. Therefore, it is highly recommended to perform unexpected antibody screening test in all transfusion candidates. Here, the frequency and distribution of unexpected antibodies identified in Jeju for the past 3 years were evaluated. Between Jan 2014 and Dec 2016, unexpected antibody screening test was performed for 10,360 sera of transfusion candidates in Jeju general hospital using a column agglutination method with the Ortho BioVue system (Ortho-clinical Diagnostics, Raritan, NJ, USA). Eighty-seven (0.84%) of 10,360 cases that underwent unexpected antibiotics screening showed positive results. Among them, unexpected antibodies were identified in 41 cases (0.40%). Unidentified antibodies were detected in 8 cases (19.51%) and autoantibodies were detected in 3 cases (7.32%). The anti-E antibody included in warm antibodies were detected most frequently in 8 cases (19.51%); 6 cases (14.63%) of anti-E + anti-c antibody and 3 cases (7.32%) of $anti-Le^a+anti-Le^b$. $Anti-Le^a$ and $anti-Le^b$ antibodies were detected in 2 cases (4.88%), respectively. The anti-D, $anti-Di^a$, $anti-Fy^b$, $anti-Jk^a$, $anti-Jk^b$, anti-M and anti-P1 were detected in 1 case (2.44%). Complex antibodies were detected in 1 case (2.44%) in anti-C+anti-D and anti-E+anti-c+$anti-Jk^b$, respectively. In this study, we analyzed the frequency and distribution of unexpected antibodies in one general hospital for the past 3 years. However, there has been a general increase in multicultural families and foreign workers in Jeju, and it would be a meaningful study to compare the frequency and distribution of unexpected antibodies.

Residual Stress Measurement of Flat Welded Specimen by Electronic Speckle Pattern Interferometry (전자처리스페클패턴 간섭법을 이용한 평판 용접시험편의 잔류응력 측정)

  • Chang, Ho-Seob;Kim, Dong-Soo;Jung, Hyun-Chul;Kim, Kyung-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.149-154
    • /
    • 2012
  • The size and distribution of welding residual stress and welding deformation in welding structures have an effect on various sorts of damage like brittle failure, fatigue failure and stress corrosion cracking. So, research for this problem is necessary continuously. In this study, non-destructive technique using laser electronic speckle pattern interferometry, plate of welding specimen according to the external load on the entire behavior of residual stress are presented measurement techniques. Once, welding specimen force tensile loading, using electronic speckle pattern interferometry is measured. welding specimen of base metal and weld zone measure strain from measured result, this using measure elastic modulus. In this study, electronic speckle pattern interferometry use weld zone and base metal parts of the strain differences using were presented in residual stress calculated value, This residual stress value were calculated by numerical calculation. Consequently, weld zone of modulus high approximately 3.7 fold beside base metal and this measured approximately 8.46 MPa.

Acoustic Emission Signal Analysis for Damage Assessment of the Reinforced Concrete Slab Structures (철근 콘크리트 슬래브 구조 손상 평가를 위한 음향방출 신호분석)

  • Kim, Jeong-Hee;Han, Byeong-Hee;Seo, Dae-Cheol;Yoon, Dong-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.360-367
    • /
    • 2009
  • The acoustic emission(AE) behavior of reinforced concrete slab under flexural loading was investigated to assess the integrity. This study was aimed at identifying the characteristics of AE response associated with damage development. By applying cyclic loading in various load steps, it was able to differentiate each AE source such as distributed micro crack initiation, friction, flexural crack and localized diagonal tension crack. The secondary peak and the change of AE hit rate gave valuable criteria fur assessment. From the analysis of the felicity ratio, furthermore, it was shown that this values can be used for evaluating the degree of concrete damage. Based on the experimental results, this approach for practical AE application may provide a promising method for estimating the level of damage and distress in concrete structures.

Investigation on Guided Wave Dispersion Characteristics for Metal Thin Films (금속 박막의 유도초음파 분산 특성 연구)

  • Kim, Miso;Cho, Seung Hyun;Jang, Gang-Won;Lee, Seung-Seok;Park, Ik-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.3
    • /
    • pp.233-240
    • /
    • 2014
  • In this study, we investigated the dispersion characteristics of guided waves in thin films. Dispersion curves are essential for understanding not only the behavior of ultrasonic waves, but also the mechanical properties of thin films. Matrix techniques are presented for modeling ultrasonic waves in multilayered structures before being used to calculate the dispersion curves for Al-steel and Al-composite specimens. When compared with the dispersion curves obtained using the commercial program (Disperse), the dispersion curves generated from the transfer matrix method show its validity. These developed methods are used to obtain dispersion curves for Al thin films deposited on a Si substrate. The resulting dispersion curves enable observation of both dispersive and non-dispersive behavior for the guided waves, depending on the thickness of the thin films.

A study on a Integrated analysis for survey of the cavity behind the Concrete (콘크리트 배면 공동탐사를 위한 복합적 해석 연구)

  • Noh, Myung-Gun;Oh, Seok-Hoon;Suh, Baek-Soo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.185-189
    • /
    • 2009
  • Integrated analysis of GPR, impact echo and impulse response for detection of the rear cavity of concrete was performed on the test-bed which was made in the same scale and component ratio to the real concrete structure. GPR survey may roughly delineate the location of the cavity, but applying the IE and IR technique to the test-bed, the location was clearly identified.

  • PDF

Design of Partial Discharge Sensor using Transmission Line Theory in Rotating Machine (전송선로 이론을 이용한 회전기내 부분방전 검출 센서 해석 및 설계)

  • Heo, Chang-Geun;Kang, Dong-Sik;Jung, Hyun-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.49-51
    • /
    • 2004
  • 고전압 기기의 절연물 내부에서 부분방전 현상이 발생되면 절연파괴로 진전된다. 회전기기가 운전중인 상태에서 on-line 부분방전시험은 고정자 권선의 절연상태를 검사, 평가 할 수 있는 중요한 수단으로서 이러한 부분방전시험을 통하여 회전기기 시스템의 사고예방을 위한 진단을 할 수 있다. 부분방전 펄스는 10MHz $\sim$ 1GHz의 대역폭을 갖는 것으로 알려져 있으며, 이러한 고주파 대역의 전자파 에너지의 효과적인 검출을 위한 센서 중 하나로 웨이브가이드 구조의 고주파 검출센서가 존재한다. 기존의 전자기적 에너지를 검출하는 SSC (Stator Slot Coupler)센서를 한쪽 포트를 가지는 마이크로스트립센서 형태로 사용할 경우 접지면이 도체전체로 씌워져 있고 임피던스 정합을 위한 50옴의 칩저항이 신호라인과 접지사이 루프를 형성하여 기기 운전시 기기의 성능에 영향을 미칠 수 있는 단점을 가지고 있다. 이 단점을 보완하기 위해서 본 논문에서는 회전기내 부분방전 펄스의 전자기적 에너지를 검출할 수 있는 2선 평행 전송선로 라인을 응용한 부분방전 검출 센서를 제안하였고 시뮬레이션을 통해 성능을 입증하였다. 제안된 센서의 성능을 입증하기 위하여 2선 평행 전송선로 타입의 센서와 기존의 SSC (Stator Slot Coupler) 센서를 약간 변형시킨 마이크로 스트립 센서를 고정자 슬롯의 Wedge 부착한 후 두 센서 비교 분석하였다. 결과적으로 제안된 센서는 기존 SSC 타입의 마이크로스트립 센서에 비하여 더 간단한 형상을 가지며 운전 중 기기의 성능에 영향을 덜 미치는 효과를 얻을 수 있었다.

  • PDF

Preparation and Characteristics of Chestnut Mooks (밤묵의 제조와 그 특성)

  • 윤광섭;김순동;신승렬
    • Food Science and Preservation
    • /
    • v.6 no.4
    • /
    • pp.429-434
    • /
    • 1999
  • This study was undertaken to investigate preparation possibility of chestnut mooks added chestnut shell. Three types of chesetnut starches which were flesh starch(FS), inside shell containing starch(ISS), and shell containing starch(SCS) and acorn starch(AS) as control were used to preparation of mook. The crude tannin contents of chestnut starches was about 25% of that in acorn starch. In the textural properies, hardness of mooks was increased in proportion to the increasing concentration of starches. Hardness md cohesiveness of mooks with chesnut starches were higher than those of acorn starch. Color properties of mooks with OSS were similar to that of AS. Sensory evaluation by 9-point method indicated that the nooks with ISS had greater intensities in all investigation items. The total scores were higher in order of ISS, AS, FS and SCS. The mook with ISS had homogeneous and porous structure by SEM.

  • PDF

Impacts of Bioactive Components Addition on Qualities of Imitation Crab Meat Containing Spent Laying Hen Meats During Storage (기능성 물질의 첨가가 폐계육이 함유된 게맛살의 저장중 품질에 미치는 영향)

  • Jin, Sang-Keun;Hur, Sun-Jin;Shin, Teak-Soon
    • Journal of Life Science
    • /
    • v.20 no.6
    • /
    • pp.861-869
    • /
    • 2010
  • Imitation crab stick samples were made from Alaska pollack with protein recovered from spent laying hens breast meat (C), Alaska pollack with spent laying hens breast recovered protein and cordyceps powder (T1), Alaska pollack with spent laying hens breast recovered protein and silkworm cocoon powder (T2), and Alaska pollack with spent laying hens breast recovered protein and conjugated linoleic acid (CLA) (T3). There were no significant differences in moisture, crude protein and crude fat among the imitation crab samples. pH was significantly higher in T2 and T3 compared with C and T1 after 4 weeks of storage. The values of $L^*$, $a^*$, $b^*$, and W (whiteness) in T3 were found to be more stable during storage and W in T3 was significantly higher than other samples. T3 was significantly lower in hardness, brittleness, gumminess and adhesiveness after 4 weeks of storage. Thiobarbituric acid reactive substance (TBA) values decreased with storage, whereas volatile basic nitron (VBN) values increased with storage periods in all samples. In sensory evaluation, there were no significant differences in color, odor, taste, tenderness, juiciness and overall acceptability among the samples. T3 was significantly lowest in quality among the treated samples.

The Clinical Evaluation of Anomalous Bronchi Arising From The Trachea and Main Bronchi (기관 및 주기관지에서 발생한 기관지기형의 임상적 고찰)

  • Kim, Jun Chul;Kim, Yeon Jae;Kang, Byung Jun;Youn, Young Deuk;Lee, Se Young;Kwon, Young Lan;Lee, Soo Ok;Jeong, Chi Yeong;Lee, Byung Ki
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.6
    • /
    • pp.664-669
    • /
    • 2005
  • Objectives : To evaluate the clinical significance of abnormal bronchi originating from the trachea or main bronchi. Methods : 21 patients (male:female ratio, 13:8; mean age, 58.2 years, range 34-77), who were diagnosed with major tracheobronchial anomalies by bronchoscopy from January 2001 to March 2005, were enrolled in this study. The anomalous bronchi consisted of 13 tracheal bronchi and 8 cardiac accessory bronchus. The clinical features, bronchoscopic findings, and outcomes were analyzed retrospectively. Results : Common symptoms, including hemoptysis, cough and dyspnea, resulted from the underlying lung disease regardless of the bronchial anomalies. In this series of 13 tracheal bronchi, 7 cases originated from the trachea within 1cm of the carina (carinal type) and 6 cases originated at a higher level(tracheal type). Most patients had favorable outcome with conservative treatment for the underlying lung disease. Conclusion : Most tracheobronchial anomalies are found incidentally in the process of diagnosing lung disease. The clinical outcome of patients with a bronchial anomaly depends on the underlying lung disease.