• Title/Summary/Keyword: 비 접촉 측정

Search Result 923, Processing Time 0.032 seconds

Dealumination of $NH_4Y$-Zeolite to Convert to the Hydrophobic Zeolite by High-Temperature Steam Treatment (소수성 제올라이트로의 변환을 위한 고온 수증기처리에 의한 $NH_4Y$-제올라이트의 탈알루미늄)

  • Kim, Jin-Young;Jeon, Dong-Hwan;Chung, Byung-Hwan;Mo, Se-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.420-430
    • /
    • 2005
  • This study was performed to change the hydrophilic $NH_4Y$-zeolite to the hydrophobic one for removal of VOCs by removing the $Al^{3+}$ in the zeolite-structure to increase the Si/Al ratio, for which the three pelleted $NH_4Y$-zeolite samples were contacted separately with the steam of $400^{\circ}C$, $500^{\circ}C$ and $600^{\circ}C$, respectively, in a stainless steel column for 4 hours. Then extraction of the ex-structure aluminum of the hydrolyzed zeolites with the nitric acids of 0.25, 0.50, 0.75, and 0.10 M at $90^{\circ}C$ in 500 mL-flasks, respectively, according to steam temperature were followed. XRD analysises of the dealuminated zeolites showed that the peaks of the zeolites that had been hydrolyzed with the steams of both $500^{\circ}C$ and $600^{\circ}C$ are distorted more with the increase of the concentration of nitric acid used for extraction of the ex-structure aluminums, however, those hydrolyzed with steam of $400^{\circ}C$ became amorphous phase when treated with the all nitric acids of four concentrations. Also the EDX analysises showed that the BET surface areas and TPVS of the zeolites that had been hydrolyzed with the steam of $600^{\circ}C$ were increased with the concentration of the nitric acid when the nitric acids of 0.25 M and 0.5 M had been used but decreased when the nitric acids of 0.75 M and 1.0 M had been used. These results led to the conclusion that both the $600^{\circ}C$ and $500^{\circ}C$-steam and the 0.5 M-nitric acid are appropriate to change the hydrophilic $NH_4Y$-zeolites to the hydrophobic one, which were proven by the measurement of the benzene and tolune-adsorbing capacities showing the same trend as the BET surface area and TPV The Si/Al ratios and water-adsorbing capacities of the dealuminated zeolites were increased and decreased, respectively, with the concentration of the nitric acids so that it showed that the hydrophobicity is increased.

Effect of Surface Area of Soybean Oil and Lard on the Thermooxidative Stability (대두유와 돈지의 가열산화 안정성에 미치는 표면적의 영향)

  • Kim, In-Hwan;Kim, Young-Soon;Choi, Yang-Moon
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.781-786
    • /
    • 1998
  • To assess effect of surface area on the oxidative stability in thermooxidative system, soybean oil and lard with different surface area $(0.04{\;}cm^2/g,{\;}0.08{\;}cm^2/g,{\;}0.12{\;}cm^2/g{\;}and{\;}0.16{\;}cm^2/g)$ were heated 8 hrs/day at $185^{\circ}C$. The iodine values of soybean oil heated for 64 hrs with surface area of $0.12{\;}cm^2/g$ and $0.16{\;}cm^2/g$ were 113.1 and 116.9, while those of the oil heated for the same length time with surface area of $0.04{\;}cm^2/g$ and $0.08{\;}cm^2/g$ were 126.4 and 125.9, respectively. The same trend was observed in lard, but less markedly than in soybean oil. The polar lipid content, dielectric constant and refractive index of soybean oil and lard heated with surface area above $0.12{\;}cm^2/g$ significantly increased as the heating time increased, while those of the oil heated with surface area below $0.08{\;}cm^2/g$ slowly increased as the heating time increased. On the other hand, the conjugated diene content of soybean oil heated with surface area above $0.12{\;}cm^2/g$ oil increased as the heating time increased while ratio of linoleic acid to palmitic acid decreased as the heating time increased. However, the conjugated diene content and ratio of linoleic acid to palmitic acid of lard were not significantly different depending on the surface area. The results obtained from this investigation indicated that the thermooxidative stability of oil heated with surface area below $0.08\;}cm^2/g$ was better than that of oil heated with surface area above $0.12{\;}cm^2/g$ (P<0.05).

  • PDF

Feasibility Test on Automatic Control of Soil Water Potential Using a Portable Irrigation Controller with an Electrical Resistance-based Watermark Sensor (전기저항식 워터마크센서기반 소형 관수장치의 토양 수분퍼텐셜 자동제어 효용성 평가)

  • Kim, Hak-Jin;Roh, Mi-Young;Lee, Dong-Hoon;Jeon, Sang-Ho;Hur, Seung-Oh;Choi, Jin-Yong;Chung, Sun-Ok;Rhee, Joong-Yong
    • Journal of Bio-Environment Control
    • /
    • v.20 no.2
    • /
    • pp.93-100
    • /
    • 2011
  • Maintenance of adequate soil water potential during the period of crop growth is necessary to support optimum plant growth and yields. A better understanding of soil water movement within and below the rooting zone can facilitate optimal irrigation scheduling aimed at minimizing the adverse effects of water stress on crop growth and development and the leaching of water below the root zone which can have adverse environmental effects. The objective of this study was to evaluate the feasibility of using a portable irrigation controller with an Watermark sensor for the cultivation of drip-irrigated vegetable crops in a greenhouse. The control capability of the irrigation controller for a soil water potential of -20 kPa was evaluated under summer conditions by cultivating 45-day-old tomato plants grown in three differently textured soils (sandy loam, loam, and loamy sands). Water contents through each soil profile were continuously monitored using three Sentek probes, each consisting of three capacitance sensors at 10, 20, and 30 cm depths. Even though a repeatable cycling of soil water potential occurred for the potential treatment, the lower limit of the Watermark (about 0 kPa) obtained in this study presented a limitation of using the Watermark sensor for optimal irrigation of tomato plants where -20 kPa was used as a point for triggering irrigations. This problem might be related to the slow response time and inadequate soil-sensor interface of the Watermark sensor as compared to a porous and ceramic cup-based tensiometer with a sensitive pressure transducer. In addition, the irrigation time of 50 to 60 min at each of the irrigation operation gave a rapid drop of the potential to zero, resulting in over irrigation of tomatoes. There were differences in water content among the three different soil types under the variable rate irrigation, showing a range of water contents of 16 to 24%, 17 to 28%, and 24 to 32% for loamy sand, sandy loam, and loam soils, respectively. The greatest rate increase in water content was observed in the top of 10 cm depth of sandy loam soil within almost 60 min from the start of irrigation.

A STUDY ON WEAR RESISTANCE OF FLOWABLE COMPOSITE RESINS (유동성 복합레진의 마모저항성에 관한 연구)

  • Yun, Yeon-Hee;Kim, Jung-Wook;Lee, Sang-Hoon;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.2
    • /
    • pp.217-225
    • /
    • 2002
  • When we use the flowable resin on the primary molars for quick handling, one of the most important property is the wear resistance. This study was performed to compare the wear resistance characteristics of four flowable composite resins [Arabesk flow (group 1), Tetric flow (group 2), Aeliteflow (group 3), Filtek flow (group 4)] to that of one control composite resin [Z100 (group 5)]. Specimen discs(n=10), 10mm wide and 2mm thick, were stored in distilled water at $37^{\circ}C$ for 7 days prior to testing. The specimens were subjected to 50,000 strokes at 2 Hz on the MTS system. During the test, the following parameters were maintained: the lateral excursion at 0.4mm, occlusal force at 2-100N with a force profile in the form of a half sine wave. The measurements of volume loss, depth of wear, and Vicker's hardness number of composite resins, and SEM observations of the polished and abraded surfaces were established. One-way ANOVA and Scheffe's multiple comparison test were employed to detect statistically significant differences among the flowable composite resin groups and the control composite group at P<.05. The following results were obtained: 1. Group 3 showed the least volume loss, while group 4 showed the greatest. The mean volume loss increased in the following order: group 3

  • PDF

Comparison and evaluation between 3D-bolus and step-bolus, the assistive radiotherapy devices for the patients who had undergone modified radical mastectomy surgery (변형 근치적 유방절제술 시행 환자의 방사선 치료 시 3D-bolus와 step-bolus의 비교 평가)

  • Jang, Wonseok;Park, Kwangwoo;Shin, Dongbong;Kim, Jongdae;Kim, Seijoon;Ha, Jinsook;Jeon, Mijin;Cho, Yoonjin;Jung, Inho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.7-16
    • /
    • 2016
  • Purpose : This study aimed to compare and evaluate between the efficiency of two respective devices, 3D-bolus and step-bolus when the devices were used for the treatment of patients whose chest walls were required to undergo the electron beam therapy after the surgical procedure of modified radical mastectomy, MRM. Materials and Methods : The treatment plan of reverse hockey stick method, using the photon beam and electron beam, had been set for six breast cancer patients and these 6 breast cancer patients were selected to be the subjects for this study. The prescribed dose of electron beam for anterior chest wall was set to be 180 cGy per treatment and both the 3D-bolus, produced using 3D printer(CubeX, 3D systems, USA) and the self-made conventional step-bolus were used respectively. The surface dose under 3D-bolus and step-bolus was measured at 5 measurement spots of iso-center, lateral, medial, superior and inferior point, using GAFCHROMIC EBT3 film (International specialty products, USA) and the measured value of dose at 5 spots was compared and analyzed. Also the respective treatment plan was devised, considering the adoption of 3D-bolus and stepbolus and the separate treatment results were compared to each other. Results : The average surface dose was 179.17 cGy when the device of 3D-bolus was adopted and 172.02 cGy when step-bolus was adopted. The average error rate against the prescribed dose of 180 cGy was -(minus) 0.47% when the device of 3D-bolus was adopted and it was -(minus) 4.43% when step-bolus was adopted. It was turned out that the maximum error rate at the point of iso-center was 2.69%, in case of 3D-bolus adoption and it was 5,54% in case of step-bolus adoption. The maximum discrepancy in terms of treatment accuracy was revealed to be about 6% when step-bolus was adopted and to be about 3% when 3D-bolus was adopted. The difference in average target dose on chest wall between 3D-bolus treatment plan and step-bolus treatment plan was shown to be insignificant as the difference was only 0.3%. However, to mention the average prescribed dose for the part of lung and heart, that of 3D-bolus was decreased by 11% for lung and by 8% for heart, compared to that of step-bolus. Conclusion : It was confirmed through this research that the dose uniformity could be improved better through the device of 3D-bolus than through the device of step-bolus, as the device of 3D-bolus, produced in consideration of the contact condition of skin surface of chest wall, could be attached to patients' skin more nicely and the thickness of chest wall can be guaranteed more accurately by the device of 3D-bolus. It is considered that 3D-bolus device can be highly appreciated clinically because 3D-bolus reduces the dose on the adjacent organs and make the normal tissues protected, while that gives no reduction of dose on chest wall.

  • PDF

Estimation of Fresh Weight and Leaf Area Index of Soybean (Glycine max) Using Multi-year Spectral Data (다년도 분광 데이터를 이용한 콩의 생체중, 엽면적 지수 추정)

  • Jang, Si-Hyeong;Ryu, Chan-Seok;Kang, Ye-Seong;Park, Jun-Woo;Kim, Tae-Yang;Kang, Kyung-Suk;Park, Min-Jun;Baek, Hyun-Chan;Park, Yu-hyeon;Kang, Dong-woo;Zou, Kunyan;Kim, Min-Cheol;Kwon, Yeon-Ju;Han, Seung-ah;Jun, Tae-Hwan
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.23 no.4
    • /
    • pp.329-339
    • /
    • 2021
  • Soybeans (Glycine max), one of major upland crops, require precise management of environmental conditions, such as temperature, water, and soil, during cultivation since they are sensitive to environmental changes. Application of spectral technologies that measure the physiological state of crops remotely has great potential for improving quality and productivity of the soybean by estimating yields, physiological stresses, and diseases. In this study, we developed and validated a soybean growth prediction model using multispectral imagery. We conducted a linear regression analysis between vegetation indices and soybean growth data (fresh weight and LAI) obtained at Miryang fields. The linear regression model was validated at Goesan fields. It was found that the model based on green ratio vegetation index (GRVI) had the greatest performance in prediction of fresh weight at the calibration stage (R2=0.74, RMSE=246 g/m2, RE=34.2%). In the validation stage, RMSE and RE of the model were 392 g/m2 and 32%, respectively. The errors of the model differed by cropping system, For example, RMSE and RE of model in single crop fields were 315 g/m2 and 26%, respectively. On the other hand, the model had greater values of RMSE (381 g/m2) and RE (31%) in double crop fields. As a result of developing models for predicting a fresh weight into two years (2018+2020) with similar accumulated temperature (AT) in three years and a single year (2019) that was different from that AT, the prediction performance of a single year model was better than a two years model. Consequently, compared with those models divided by AT and a three years model, RMSE of a single crop fields were improved by about 29.1%. However, those of double crop fields decreased by about 19.6%. When environmental factors are used along with, spectral data, the reliability of soybean growth prediction can be achieved various environmental conditions.

Improved Photoelectric Conversion Efficiency of Perovskite Solar Cells with TiO2:TiCl4 Electron Transfer Layer (TiO2:TiCl4 전자수송층을 도입한 페로브스카이트 태양전지의 광전변환효율 향상)

  • Ahn, Joon-sub;Kang, Seung-gu;Song, Jae-gwan;Kim, Jin-bong;Han, Eun-mi
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.4
    • /
    • pp.85-90
    • /
    • 2017
  • The $TiCl_4$ as a blocking material is adsorbed in the mesoporous $TiO_2$ electron transfer layer(ETL) of the Perovskite solar cell to prevent the direct contact between the FTO electrode and the photoactive layer(AL), and facilitate the movement of the electrons between $TiO_2:TiCl_4$ ETL and Perovskite AL to improve the photoelectric conversion efficiency(PCE). The structure of the perovskite solar cell is FTO/$TiO_2:TiCl_4$/Perovskite($CH_3NH_3PbI_3$)/spiro-OMeTAD/Ag. It was investigated that the dipping time of the $TiO_2$ into $TiCl_4$ aqueous solution affects on the photoelectric characteristics of the device. By the dipping for 30 minutes, the PCE of the perovskite solar cell with the $TiO_2:TiCl_4$ ETL was the highest 10.46%, which is 27% higher than the cell with $TiO_2$ ETL. From SEM, EDS, and XRD characterization on the $TiO_2:TiCl_4$ ETL and the perovskite AL, it was measured that the decrease of the porosity of the $TiO_2$ layer, the detection of the Cl component by the $TiCl_4$ adsorption, the cube-type morphology of perovskite AL, and shift of the $PbI_2$ peak of the perovskite AL. From these results, it was confirmed that the $TiO_2:TiCl_4$ ETL and the perovskite AL were formed.

INHIBITORY EFFECT OF DENTAL LASERS ON THE GROWTH AND THE FUNCTION OF STREPTOCOCCUS MUTANS (각종 치과레이저의 Streptococcus mutans에 대한 증식 및 기능억제 효과)

  • Han, Kang-Seog;Kook, Joong-Ki;You, So-Young;Kim, Hwa-Sook;Park, Jong-Whi;Park, Heon-Dong;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.439-447
    • /
    • 2003
  • This was performed to evaluate the inhibitory effect of laser on the growth of S. mutans. The bacterial pallets containing S. mutans KCTC 3065 were irradiated with Er:YAG laser and Nd :YAG laser by non-contact method at an intensity of 50mJ for 5 sec with the pulse repetition rates of 10Hz and 30Hz, respectively. The following results were obtained on colony count, acid producing ability, and the amount of insoluble extracellular polysaccharide synthesis. 1. The irradiation of Nd:YAG laser after photosensitization with Chinese ink inhibited the proliferation of S. mutans the most, and the irradiation of Er:YAG also inhibited the proliferation. However, the irradiation of Nd:YAG laser alone could not inhibited the proliferation of S. mutans. The pulse repetition rate did not affect significantly on the proliferation of bacteria in overall. 2. The irradiation of Nd:YAG laser after the photosensitization with Chinese ink inhibited the acid production of S. mutans the most for a certain period of time. Er:YAG laser also inhibited acid production. When Nd:YAG laser was used alone, the acid production of S. mutans was not been inhibited. The irradiation of Nd:YAG laser after photosensitization with Chinese ink inhibited the acid production ability of bacteria the most as the pulse repetition rate increased. 3. Laser irradiation did not inhibited the synthesis of insoluble extracellular polysaccharide of S. mutans. From these results, we conclude that the irradiation of Er:YAG laser and Nd:YAG laser after photosensitization with Chinese ink would inhibit the proliferation and acid production by S. mutans, which may prevent dental caries. However, this effect does not last long time so that the laser irradiation should be repeated frequently in order to obtain clinical effect; thus, this laser irradiation would not have a clinical usefulness in preventing dental caries when used solely.

  • PDF

Influence of the angles and number of scans on the accuracy of 3D laser scanning (3 차원 레이저 스캔영상 채득 시 스캔각도와 횟수에 따른 정확도)

  • Lee, Kyung-Min;Song, Hyo-Young;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.41 no.2
    • /
    • pp.76-86
    • /
    • 2011
  • Objective: To investigate whether the accuracy of 3D laser scanning is influenced by the angles and number of scans. Methods: Using a 3D laser scanner, 10 manikins with facial markers were scanned at 7 horizontal angles (front view and at $20^{\circ}$, $45^{\circ}$, and $60^{\circ}$ angles on the right and left sides). Three-dimensional facial images were reconstructed by 6 methods differing in the number and angles of scans, and measurements of these images were compared to the physical measurements from the manikins. Results: The laser scan images were magnified by 0.14 - 0.26%. For images reconstructed by merging 2 scans, excluding the front view; and by merging 3 scans, including the front view and scans obtained at $20^{\circ}$ on both sides; several measurements were significantly different than the physical measurements. However, for images reconstructed by merging 3 scans, including the front view; and 5 scans, including the front view and scans obtained at $20^{\circ}$ and $60^{\circ}$ on both sides; only 1 measurement was significantly different. Conclusions: These results suggest that the number and angle of scans influence the accuracy of 3D laser scanning. A minimum of 3 scans, including the front view and scans obtained at more than $45^{\circ}$ on both sides, should be integrated to obtain accurate 3D facial images.

Prevalence of Antibodies to Hepatitis A in the Healthy Children in Inchon-Kyunggi Prefecture (경인 지역 소아의 A형 간염 항체 보유율)

  • Kwon, Young Se;Hong, Young Jin;Choe, Yon Ho;Kim, Soon Ki;Son, Byong Kwan;Kang, Moon Su;Pai, Soo Hwan;Hong, Kwang Sun
    • Pediatric Infection and Vaccine
    • /
    • v.5 no.2
    • /
    • pp.239-244
    • /
    • 1998
  • Purpose : The incidence of hepatitis A virus infection in Korea has decreased recently. However, the prevalence in children and young adults is on an increasing trend in Inchon-Kyunggi prefecture. Economic development that leads to better living conditions and improves hygiene facilities has reduced the rate of HAV infection. This study was designed to evaluate the recent seroprevalence rate of hepatitis A in children and adolescents. Methods : Study population consisted of 612 children and adolescents aged 1 to 17 years in Inchon-Kyunggi prefecture. Serum samples were collected between 1996 and 1997 and tested for anti HAV by Microparticle Enzyme Immunoassay(MEIA). Results : According to age, the seropositive rates were 10.5%(male 13%, female 6.7%) in 1 year-old group, 0% in 3, 5, 11 and 13 year-old group, 6%(male 8%, female 4%) in 15 year-old group, and 11%(male 14%, female 8%) in 17 year-old group. Conclusion : This study showed that seropositive rate of HAV infection increased with age. While it revealed extremely low incidence of HAV infection in children less than 13 years old, they are also likely 10 be exposed 10 the infection. Our findings suggest that the effective administration of vaccination is needed in selected and high risk groups.

  • PDF