• Title/Summary/Keyword: 비파괴 손상평가

Search Result 186, Processing Time 0.028 seconds

Linkage of Damage Evaluation to Structural System Reliability (손상평가와 구조물 신뢰성과의 연계)

  • Park, Soo Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.1
    • /
    • pp.41-50
    • /
    • 2003
  • Nondestructive Damage Evaluation (NDE) techniques yield the damage location and its size from the modal characteristics of pre-damaged and post-damaged structures. To predict the system reliability of the aging structure, results from the NDE are integrated into the element/component failure probabilities. The element/component failure probabilities can be calculated from failure functions for each element/component with the aid of techniques from a structural reliability analysis. In this paper, a method to estimate the system reliability of a structure that is based on the reliabilities of elements/components in a given structure is presented. The efficacy of the combination of the nondestructive damage detection and the structural reliability evaluation is demonstrated using pre-damaged and post-damaged modal data obtained from numerical simulations of a rigid frame.

Nondestructive Evaluation of Fatigue Damage (피로손상과 비파괴평가)

  • Kwon, Oh-Yang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.54-61
    • /
    • 2000
  • In order to determine the mode I stress intensity factor ($K_I$) by means of the alternating current potential drop(ACPD) technique, the change in potential drop due to load for a paramagnetic material containing a two-dimensional surface crack was examined. The cause of the change in potential drop and the effects of the magnetic flux and the demagnetization on the change in potential drop were clarified by using the measuring systems with and without removing the magnetic flux from the circumference of the specimen. The change in potential drop was linearly decreased with increasing the tensile load and was caused by the change in conductivity near the crack tip. The reason of decreasing the change in potential drop with increasing the tensile load was that the increase of the conductivity near the crack tip due to the tensile load caused the decreases of the resistance and internal inductance of the specimen. The relationship between the change in potential drop and the change in $K_I$ was not affected by demagnetization and was independent of the crack length.

  • PDF

복합재 압력용기의 비파괴 시험과 평가

  • Jeong, Hyeon-Jo
    • Defense and Technology
    • /
    • no.10 s.164
    • /
    • pp.38-42
    • /
    • 1992
  • 복합재 압력용기의 제작 및 사용중에 발생하는 결함(손상)의 비파괴검사를 통해 구조물의 건전성을 평가하는 것은 제품의 품질보증 관점에서 아주 중요합니다. 복합재에서는 여러 종류의 결함이 동시에 존재할수 있으며, 결함-기계적 성질-비파괴특성 사이의 상호관계는 완전히 알려져 있지 않습니다. 이글에서는 복합재 연소관에 존재하는 결함의 위험도와 결함 탐지를 위한 비파괴 검사 기법에 대해 먼저 살펴보았습니다. Filament Winding으로 제조한 복합재 연소관의 Proof Testing과 관련해 음향방출(AE)법에 의한 최근의 연구결과를 살펴본 다음, 연소관의 신뢰도 확보를 위한 비파괴 평가 방법에 대해 앞으로의 연구 방향을 제시하였습니다

  • PDF

Application of Laser Ultrasonic Technique for Nondestructive Evaluation of Wall Thinning in Pipe (배관부 감육 손상의 비파괴 평가를 위한 레이저 초음파 기술 적용)

  • Hong, Kyung-Min;Kang, Young-June;Park, Nak-Kyu;Yoon, Suk-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.4
    • /
    • pp.361-367
    • /
    • 2013
  • Many of the nuclear power plant pipe is used in high temperature and high pressure environment. Wall thinning frequently caused by the corrosion. These wall thinning in pipe is expected gradually increase as nuclear power become superannuated. Therefore there is need to evaluate wall thinning in pipe and corrosion defect by non-destructive method to prevent the accident of the nuclear power facility due to pipe corrosion. Especially for real-time assessment of the wall thinning that occurs in nuclear power plant pipe, the laser ultrasonic technology can be measured even in hard-to-reach areas, beyond the limits of earlier existing contact methods. In this study, the optical method using laser was applied for non-destructive and non-contact evaluation. Ultrasonic signals was acquired through generating ultrasonic by pulse laser and using laser interferometer. First the ultrasonic signal was detected in no wall thinning in pipe, then a longitudinal wave velocity was measured inside of pipe. Artificial wall thinning specimen compared to 20, 30, 40 and 50% of thickness of the pipe was produced and the longitudinal wave velocity was measured. It was possible to evaluate quantitatively the wall thinning area(internal defect depth) cause it was able to calculate the thickness of each specimen using measured longitudinal wave velocity.

Designing a Highly Sensitive Eddy Current Sensor for Evaluating Damage on Thermal Barrier Coating (열차폐코팅의 비파괴적 손상 평가를 위한 고감도 와전류 센서 설계)

  • Kim, Jong Min;Lee, Seul-Gi;Kim, Hak Joon;Song, Sung Jin;Seok, Chang Seong;Lee, Yeong-Ze
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.3
    • /
    • pp.202-210
    • /
    • 2016
  • A thermal barrier coating (TBC) has been widely applied to machine components working under high temperature as a thermal insulator owing to its critical financial and safety benefits to the industry. However, the nondestructive evaluation of TBC damage is not easy since sensing of the microscopic change that occurs on the TBC is required during an evaluation. We designed an eddy current probe for evaluating damage on a TBC based on the finite element method (FEM) and validated its performance through an experiment. An FEM analysis predicted the sensitivity of the probe, showing that impedance change increases as the TBC thermally degrades. In addition, the effect of the magnetic shield concentrating magnetic flux density was also observed. Finally, experimental validation showed good agreement with the simulation result.

Quantitative Evaluation of Delamination Inside of Composite Materials by ESPI (ESPI를 이용한 복합재료 박리결함의 정량평가)

  • Kim, Koung-Suk;Yang, Kwang-Young;Kang, Ki-Soo;Ji, Chang-June
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.3
    • /
    • pp.246-252
    • /
    • 2004
  • Electronic speckle pattern interferometry (ESPI) for quantitative evaluation of delaminations inside of a composite material plate is described. Delaminations caused by the impact on composite materials are difficult to detect visual inspection and ultrasonic testing due to non-homeogenous structure. This paper proposes the quantitative evaluation technique of the defects made in the composite plates by impact load. Artificial defects are introduced inside of the composite plate for the development of a reliable ESPI inspection technique. Real defects produced by impact tester are inspected and compared with the results of visual inspection which shows a good agreement within 5% error.

Quantitative Nondestructive Evaluation in Composite Beam Using Piezoelectric Transducers (압전 변환기를 이용한 복합재료 보의 비파괴 평가)

  • Lee, Sang-Hyoup;Choi, Young-Geun;Kim, Sang-Tae
    • Composites Research
    • /
    • v.20 no.3
    • /
    • pp.31-36
    • /
    • 2007
  • A quantitative prediction method for initial crack length in a carbon/epoxy (CF/EP) composite beam using active piezoelectric transducers was established in this study. Wavelet Transform (WT)-based signal processing and identification technique in time-frequency domain was developed to facilitate the determination of damage presence and severity. Dynamic response of a CF/EP composites beam containing a continuously expanding crack, coupled with a pair of active piezoelectric disks, was examined under a narrow band excitation, and then applied with the proposed signal processing technique.

Material Degradation and Life Assessment in Mechanical Equipment and Structure (기계.구조물의 경년열화와 수명평가기술)

  • Kim, K.Y.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.2
    • /
    • pp.129-144
    • /
    • 1999
  • 플랜트와 같은 장치산업은 내구성 구조물이므로 사용중에 열화가 발생하는 것은 필연적이다. 특히 고온, 고압의 부식환경하에서 사용되는 설비는 손상이 심하므로 가동중에 돌발적인 고장이 발생하여 플랜트의 가동을 중지하거나 파손사고가 일어나 생산손실은 물론 경우에 따라서는 안전사고의 발생, 환경오염 등 사회적인 문제를 일으키므로 이들 설비의 경년열화 실체를 충분히 이해하고 대책을 수립하는 것은 대단히 중요하다. 따라서 본고에서는 장치산업에서 발생하는 열화현상(재료의 연화, 경화 및 취화, 크리프, 피로, 부식, 마모 등)중 손상의 주류를 이루는 연화, 경화 및 취화, 크리프 피로에 대하여 기본적인 손상기구(damage mechanism)와 비파괴적 진단 및 평가 방법에 주안점을 두어, 현재 국내의 각종 플랜트 진단에 실용화된 기술을 해설하여 이 분야에 종사하는 관계자 여러분의 이해에 조금이라도 기여코자 한다.

  • PDF

Detection and Evaluation Technique of Hydrogen Attack (수소손상 검출과 평가기술)

  • Won, Soon-Ho;Hyun, Yang-Ki;Lee, Jong-O;Cho, Kyung-Shik;Lee, Jae-Do
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.1
    • /
    • pp.32-37
    • /
    • 2002
  • The presence of hydrogen in industrial plants is a source of damage. Hydrogen attack is one such form of degradation and often causing large tube ruptures that necessitate an immediate shutdown. Hydrogen attack may reduce the fracture toughness as well as the strength of steels. This reduction is caused partially by the presence of cavities and microcracks at the grain boundaries. In the past several techniques have been used with limited results. This paper describes the application of an ultrasonic velocity and attenuation in hydrogen damage. Ultrasonic tests showed a decrease in wave velocity and an increase in attenuation. Such results demonstrate the potential for ultrasonic nondestructive testing to quantify damage. Based on this study, reliable recommendation is suggested to detect hydrogen attack.

A Study on Electrochemical Polarization Test for Embrittlement Damage Evaluation of Aged Cr-Mo Steel (Cr-Mo강 시효재의 취화손상 평가를 위한 전기화학적 분극시험에 관한 연구)

  • Yu, Hyo-Sun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.6
    • /
    • pp.411-419
    • /
    • 1999
  • It has been well recognized that a long term service at elevated temperature of $350^{\circ}C{\sim}550^{\circ}C$ induces embrittlement damage due to carbide precipitation and/or P, Sb and Sn segregation at grain boundaries and thereby deteriorates the grain boundary strength of heat resisting components in the energy-related plants. Therefore, it is very important to assess quantitatively the extent of embrittlement damage of heat resisting components to secure the reliable and efficient service condition and to prevent brittle failure in service. However, because fracture tests are limited in size and number of specimen obtained from the structural components, nondestructive test method is required. In this study, the optimum electrochemical parameters are investigated and discussed to evaluate nondestructive embrittlement damage for aged 2.25Cr-1Mo steels by means of electrochemical polarization test method (ECPTM) in proper corrosive environment. In addition, the electrochemical test results are compared with embrittlement degree evaluated by semi-nondestructive SP test.

  • PDF