• Title/Summary/Keyword: 비침습

Search Result 710, Processing Time 0.034 seconds

A Correlational Study between Auditory Evoked Potential and Subdural Hematoma for the Diveloprnent of a Noninvasive ICP Monitoring System (비침습적 뇌내압 측정 시스템의 개발을 위한 청각유발전위와 경막혈종간의 상관관계 분석에 관한 연구)

  • ;C.S. Lessard
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.167-174
    • /
    • 1995
  • Development of a noninvasive intensive care system calls for the use of evoked potentials (EPs) as a means of diagnosing traumatic head-injured patients. The experiment entails surgically placing two subarachnoid bolts and a subdural balloon through the skull to simulate a subdural hematoma. Using various levels of intracranial pressure (ICP) and/or different sizes of balloons, auditory evoked potentials (AEPs) were recorded from a rabbit. Six positive peak latencies ($P_1 - P_6$) and five negative peak latencies ($N_l- N_5$) were extracted from an averaged AEP waveform. Multiple regression analyses were performed for determining. a relationship between the ICP and AEP peak latencies. The results indicate that a major correlation of ch, mges on AEP peak latencies is due to mechanical forces of a mass (inflated balloon simulating a hematoma) in the distortion of the brain matter rather than increased ICP itself.

  • PDF

A development of measuring system for Autonomic Nervous Activity (자율신경계 활성도 측정 시스템 개발)

  • 이준하
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.141-146
    • /
    • 2000
  • Power spectrum analysis is a powerful noninvasive tool for quantifying autonomic nervous system activity. In this paper, We developed a measuring system for Autonomic Nervous Activity by using power spectrum analysis method to obtain the activities of autonomic nervous system. This system adopt a isolated power for patient's safety. In this system, Two output signal is obtained - R-R interval time variability and Respiration time variability. Time variability is use to find out some disease related to Autonomic Nervous System. Experimental tested range is 30 ~ 240 BPM for ECG and 15~80 BPM for Respiration.

  • PDF

상후두운동과 경부외후두근의 근전도검사에 관한 연구

  • An, Chul-Min;Jang, Hoon
    • Proceedings of the KSLP Conference
    • /
    • 1997.11a
    • /
    • pp.265-265
    • /
    • 1997
  • 음성이란 성대내근과 성대외근의 운동에 의해 진성대에서 규칙적이고 조화로운 진동이 이루어져 나타나는 것으로, 이러한 운동 등에 이상이 생기거나 진성대에 기질적인 변화가 왔을 때 음성이 변하게 된다. 그러나 이런 환자들의 진단을 위하여 후두소견을 관찰해 보면 진성대 뿐만 아니라, 상후두에서도 여러 가지 양상의 다른 움직임을 확인할 수가 있는데, 상후두는 진성대와는 달리 특별한 자체를 움직일 만한 근육들이 발달되어 있지 않은 구조물임에도 불구하고 여러 다른 발성에 따라 다양한 움직임을 나타내게 된다. 이러한 것들은 진성대와 연결되어 있는 성대내근이나 후두의 외부에 붙어있는 성대외근의 영향에 의해 나타날 수가 있다고 생각이 되고, 이러한 것들은 일차적으로 또는 이차적으로 성대의 진동에 영향을 줄 수 있을 것으로 생각된다. 이에 저자들은 발성시 상후두의 움직임과 성대외근과의 관계를 확인하기 위하여 상후두의 움직임을 여러 가지 모양으로 만들도록 훈련한 후 스트로보스 3102;을 이용하여 상후두의 움직임을 확인하면서, 각각의 경우에 따라 근육의 수축정도를 비교할 수 있고 비침습적인 표면전극을 이용한 근전도 검사를 시행하여 이들에 관한 연구를 하였다.다.

  • PDF

A study of blood disturbance by an eccentric stenosis under pulsatile flow using ultrasound imaging (초음파 영상을 이용한 박동흐름하의 편심협착에 의한 혈류 교란 연구)

  • Paeng Dong-Guk;Choi Min Joo
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.179-182
    • /
    • 2004
  • 혈관의 협착으로 인만 혈류의 교란과 그로 인한 초음파 반향의 영향을 튜브에 편심 협착 (eccentric stenosis)을 부착하고 돼지 혈액을 이용해 실험실에서 연구했다. 상용화된 GE LOGIQ 700 Expert 시스템과 M12L 의 선형 트랜스듀서를 이용해 B-모드 영상을 얻은 후 편심 협착 상류 지점과 하류 지점의 초음파 영상을 비교하여 분석하였다. 분당 20 회와 40 회의 박동율과 혈류속도를 바꿔가며 혈류의 교란에 따른 혈액에서의 초음파 영상을 분석한 결과, 편심 협착으로 인한 혈류의 교란으로 적혈구 응집현상이 달라져 복잡한 초음파 반향 분포가 형성되었다. 비침습적 실시간 초음파 영상은 편심 협착으로 인한 혈류의 교란과 그로 인한 혈액의 적혈구 응집 현상을 이해하고 연구하는데 도움이 된다.

  • PDF

The Separation Method using Color Information for Tongue Diagnosis (혀 영역에서 컬러 정보 분할을 위한 방법)

  • Kim, Keun-Ho;Do, Jun-Hyung;Kim, Jong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1970_1971
    • /
    • 2009
  • 한의학에서 혀는 장부의 건강 상태를 표면적으로 보여주는 중요한 요소 중의 하나이다. 특히 장부가 혀의 영역에 연결이 되어 각 장부의 특성을 파악하는데 매우 요긴하게 사용되고 있다. 이 연구에서는 비침습적으로 카메라와 조명 장치를 이용한 설진기를 이용하여 객관적으로 혀 영역을 촬영하고 진단을 위한 혀 영역의 객관적인 지표를 자동으로 찾는 방법을 개발하는 것을 목표로 한다. 이를 위해서 가장 중요한 일은 혀의 컬러 요소를 파악하여 정확한 위치를 찾아내는 것이다. 컬러를 색상, 채도, 명암으로 분해하고 지역 영역의 히스토그램을 분석하여 분할 임계값을 선택, 전체 영역을 분할한다. 결론적으로 이 방법은 설태가 있는 영역을 찾아내고 설태의 종류를 구분하는 방법을 제안하였다.

  • PDF

Pressure Sensor Packaging for Non-invasive Pulse Wave Measurement (비침습적 맥파 측정을 위한 압력센서 패키징에 관한 연구)

  • Kim, Eun-Geun;Nam, Ki-Chang;Heo, Hyun;Huh, Young
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1978.1_1979.1
    • /
    • 2009
  • In this paper, we have proposed and demonstrated a tonometry sensor array for measuring arterial pulse pressure. A sensor module consists of 7 piezoresistive pressure sensor array. Wire-bonded connection was provided between silicon chip and lead frame. PDMS(poly-dimethylsiloxane) was coated on the sensor array to protect fragile sensor while faithfully transmitting the pressure of radial artery to the sensor. Tonometric pulse pressure can be measured by this packaged sensor array that provides the pressure value versus the output voltage.

  • PDF

Surgical Management of Petus Excavatum with Using Pectus Bar (Pectus Bar를 이용한 누두흉에서 수술적 치료)

  • 황정주;신화균;김도형;이두연
    • Journal of Chest Surgery
    • /
    • v.34 no.2
    • /
    • pp.167-172
    • /
    • 2001
  • 배경: 누두흉은 앞가슴 기형 중 가장 흔하며 Meyer 등이 1911년 수술적 교정을 시행한 이래로 많은 술식들이 개발되어 왔다. 이들의 대부분은 전흉벽에 상처를 내고 늑연골을 자르는 과정이 필요하였다. 그러나 Nuss 등에 의해서 상기 과정없이 작은 옆가슴의 상처와 stainless steel bar로 흉골의 기형을 교정하는 국소침습적 방법이 개발되었다. 대상 및 방법: 1999년 11월부터 2000년 7월까지 누두흉의 교정을 원하는 환자 14예를 대상으로 하였다. 수술은 15세미만에서는 pectus bar를 1개를 사용하였고 그 이상에서는 2개를 사용하여 교정하였다. 결과: 남자는 11예, 여자는 3예 였으며 나이는 2세에서 52세 사이였다. 누두흉 지표는 5.3$\pm$1.84였고 비대칭지표는 1.06$\pm$0.03이였다. 수술 후 2일째 모두 일반병실로 올라갔다. 평균 재원기간은 4.2일이였다. 술후 합병증으로 성인에서 기흉 1예, 혈흉 1예, 그리고 나중에 발생한 흉막액 1예가 있었다. 결론: 누두흉에서 Nuss 술식으로 좋은 결과를 얻었다. 성인에서도 bar 2개를 이용하여 교정이 가능하였으나 소아에 비하여 합병증이 많이 발생하였는데 이는 성인에서 근육이 발달되어 있고, 뼈의 골화가 다 진행되었기 때문이다.

  • PDF

Usefulness of USG in Rotator Cuff Disease (회전근 개 질환에 대한 초음파의 유용성)

  • Choi, Chang-Hyuk;Chang, Il-Woong
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.2
    • /
    • pp.107-112
    • /
    • 2009
  • Ultrasonographic examination for the rotator cuff disease is dynamic noninvasive study and the results is comparable to MRI on the behalf of recent development. It also can be used as a tool for guided injection and follow up study after rotator cuff repair. The development of equipment, learning curve and knowledge for the disease are the three most important factors for the critical role of the ultrasonography in the diagnosis and treatment of the rotator cuff disease.

  • PDF

The acoustical analysis of knee sound for non-invasive diagnosis of articular pathology (비침습적 관절 질환 모니터링을 위한 슬관절 음향분석)

  • Kim Keo-Sik;Park Gyung-Se;Kim Kyeong-Seop;Song Chul-Gyu
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.12
    • /
    • pp.737-740
    • /
    • 2005
  • This paper describes the possibility of evaluating and classifying arthritic pathology using the acoustical analysis of knee joint sound. Six normal subjects and 11 patients with knee problems were enrolled. Patients were divided into the 1st patient group which required an orthopeadic surgery and the 2nd patient group of osteoarthritis. During sitting and standing periods, subjects' active knee flexion and extension were monitored. Fundamental frequency, mean amplitude of pitch, jitter and shimmer were analyzed according to the position. The results demonstrate that the values of fundamental frequency, jitter and shimmer of the 2nd patient group were larger than others and changed unstably. The values of the standing position were larger than the sitting position.

Study on Vascular Compliance using Photoelectric Plethysmography (광전 용적맥파를 이용한 혈관 탄성도에 관한 연구)

  • Kim, Hong-Yeop;Kim, Kyung-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2011.01a
    • /
    • pp.111-112
    • /
    • 2011
  • 본 연구에서는 광전 용적맥파(photoelectric plethysmography, PPG)를 기반으로 이를 이용하여 혈관 탄성도를 측정 할 수 있는 시스템에 관하여 연구하였다. 광전 용적맥파는 광을 이용한 비 침습적 맥파 측정 방식으로 손가락 끝 부분에서 측정하고 혈액 내에 헤모글로빈의 빛에 대한 광 흡수도의 차이로 인해 나타나게 된다. 얻어진 신호를 2차 미분 하게 되면 가속도 맥파 (acceleration photoplethymogram, APG)를 얻을 수 있고 이는 혈관 탄성도의 추정에 응용가능하다. 본 연구에서는 혈관 탄성도를 측정하기 위한 방법으로 광전 용적맥파를 적용하여 가속도 맥파 측정기기를 설계하고, 이를 바탕으로 혈관 탄성도 추정에 적용 가능 여부를 연구하였다.

  • PDF