• Title/Summary/Keyword: 비정상 열전도

Search Result 181, Processing Time 0.028 seconds

Transient Heat Conduction Through the Ondol Floor and Beat toss to the Ground (온돌의 구들장과 땅바닥의 비정상 열전도 해석)

  • Bae, Soon-Hoon;Kim, Doo-Chun
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.4 no.1
    • /
    • pp.6-17
    • /
    • 1975
  • For a periodic variation of the flue gas temperature the heat conduction through the Ondol floor was analysized. Also the heat loss to the ground was estimated. The floor thermal capacity, as a function of the floor thickness, has strong influence on the time lag of the temperature variation. It is an important design parameter for intermittent heating. Even for the steady periodic variation, there was significant heat loss to the ground below the Ondol floor.

  • PDF

열량계 채널에 대한 3차원 열전달 해석

  • Park, Tae-Seon;Seol, Woo-Seok
    • Aerospace Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.142-150
    • /
    • 2003
  • Turbulent flows and related heat transfer in a square heated duct is investigated by a turbulence model and a large eddy simulation. The cooling channel of calorimeter is modeled to the square duct. The nonlinear k-ε-fμ model of Park et al. [3] is slightly modified and their explicit heat flux model is employed. The Reynolds number is varied in the range 4000≤Reb≤20000. The heat transfer is closely linked to the secondary flows which driven by the turbulent motion. Its magnitude is 1~3% of the mean streamwise velocity. The relation of Nu~Re0.8Pr0.34 is validated by comparing with the predicted Nu of k-ε-fμ model. Finally, the coherent structures and thermal fluctuations are scrutinized.

  • PDF

A Comparative Study on Characteristics of Nanofluids Using Carbon NanoTubes (탄소 나노튜브를 이용한 나노유체의 특성 비교 연구)

  • An, Eoung-Jin;Park, Sung-Seek;Kim, Nam-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.74.1-74.1
    • /
    • 2011
  • 탄소나노튜브는 높은 전기 전도성과 열 전도성을 가지며, 이러한 특성 때문에 21세기를 주도해 나갈 수 있는 차세대 첨단 소재로서 각광을 받고 있다. 또한 최근에는 나노공학기술의 발달로 인하여 획기적으로 높은 열전도도를 나타내는 다중벽 탄소나노튜브(Multi-walled Carbon Nanotubes, MWCNTs)의 대량 생산이 가능하게 되면서 다중벽 탄소나노튜브의 높은 열전도도 특성을 이용하여 탄소나노튜브를 기본 유체 및 기능성 유체에 안정하게 분산 시킨 후 이를 이용하고자 하는 연구가 활발히 진행되고 있으며, 탄소나노튜브를 유체에 안정하게 분산시키기 위한 방법으로는 기계적 분산법, 물리적 흡착에 의한 분산법, 화학적 개질에 의한 분산법이 있다. 따라서 본 연구에서는 이들 분산 방법과 탄소나노튜브 입자의 물성치에 따른 나노유체의 특성을 알아보기 위하여 나노유체의 열전도도와 점도 특성을 비교 분석하였다. 모든 물성치는 같지만 탄소나노튜브의 길이만 다른 두 종류의 다중벽 탄소나노튜브에 각각 계면 활성제(Sodium Dodecyl Sulfate, SDS) 100 wt%와 고분자 화합물(Polyvinyl Pyrrolidone, PVP) 300 wt%를 첨가하여 나노유체를 제조하였으며, 산화처리 된 다중벽 탄소나노튜브(Oxidized Multi-Walled Carbon Nanotubes, OMWCNTs)를 증류수에 초음파 분산하여 산화나노유체를 제조하였다. 나노유체의 열전도도는 전기 전도성 유체의 비정상 열선법(Transient Hot-wire Method)을 이용하여 측정하였고, 나노유체의 점도는 회전형 디지털 점도계를 이용하여 측정하였다. 실험 결과, 상온에서 동일 혼합비의 나노유체를 비교했을 때, 산화나노유체가 SDS 100 wt%, PVP 300 wt%를 혼합한 다른 나노유체보다 높은 열전도도 특성을 보였으며 점도 특성 또한 가장 낮은 것으로 측정되었다. 특히 상온에서 0.1vol%의 산화 CM-100 나노유체는 증류수보다 열전도도가 8.34%가 증가하였고, $10^{\circ}C$의 저온에서는 상온에서 증류수와 비교하여 측정된 열전도도 값보다 0.36%가 감소한 7.98%가 증가함을 보였다. 본 연구를 통하여 얻어진 결과는 높은 열전도도를 필요로 하는 열교환기의 작동유체나 기타 활용 분야에 대한 기초 자료로써 유용한 정보를 제공할 것이라 판단된다.

  • PDF

Heat Transfer Response of an Isothermal Cylinder to Fluctuating Cross Flow (맥동류에 놓인 등온 원통의 열전달 응답)

  • 권영필;이병호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.5
    • /
    • pp.706-712
    • /
    • 1986
  • The unsteay heat transfer from an isothermal circular cylinder in fluctuating cross flow is simulated numerically, for the case where the amplitude of the oscillating velocity is small compared with the mean velocity. By solving the linear perturbation equations derived from the unsteady full Navier-Stokes and the energy equations, the amplitude and the phase of heat transfer response are obtained in the range of Reynolds number R$_{3}$ < 40. The effects of the velocity, the cylinder radius and the frequency on the response are expressed graphically in terms of the normalized velocity and the cylinder radius.

A Study on the Radiation and Convection Component Separated from Surface Combined Heat Transfer Coefficient on Dynamic Heat Load Simulation (표면 열전달율의 복사.대류성분 분리와 비정상 열부하 계산에 관한 연구)

  • Kim, Young-Tag;Choi, Chang-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.3
    • /
    • pp.1-9
    • /
    • 2005
  • The purpose of this paper was to analyze the influence of radiation and convection component separated from surface heat combined transfer coefficient on dynamic Heat load simulation. In general, it was not considered the mutual radiation of walls that heat load simulation calculated by surface combined heat transfer coefficient. In order to solve this problem, we had developed new simulation program to calculate radiation heat transfer and convection heat transfer respectively, and verified the influence of radiation component with this new program, in indoor heat transfer process.

Thermal Conductivity Measurement of Grouting Materials for Ground Heat Exchanger Borehole (지중 열교환기 보어홀 그라우팅 재료의 열전도도 측정)

  • Sohn, Byong-Hu;Shin, Hyun-Joon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.6
    • /
    • pp.493-500
    • /
    • 2006
  • This paper concerns the measurement of thermal conductivity of grouting materials for ground loop heat exchanger. A thermal conductivity meter, QTM-500 based on modified transient hot wire method was used to measure the thermal conductivity of neat bentonite and mixtures of bentonite and various additives. Relative to the total mixture mass, as the percent additive was increased the mixture thermal conductivity increased. For the bentonite-silica sand mixtures, the higher density of the sand particles resulted in much higher mixture thermal conductivity. The quartzite and silica sands produced the largest increases in mixture thermal conductivity, while common masonry and limestone sands produced lower thermal conductivity increases.

Large Time Asymptotic Solution for Unsteady Heat Conduction Problem of Coated Hot-Wire Thermal Conductivity Measurement (비정상 피복열선법 열전도도 측정시 시간-온도 특성에 대한 점근해)

  • 배철호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.7
    • /
    • pp.1684-1690
    • /
    • 1995
  • A large time asymptotic solution for an unsteady heat conduction problem of a coated hot wire thermal conductivity measurement process was theoretically found. The solution revealed that the slope of wire temperature versus logarthmic time, which is used to evaluate the thermal conductivity, remains unchanged for large values of time even if a layer of coating is present on the hot wire. The significance of this result is that the thermal conductivity of an electrically conductive fluid can be measured with a coated hot wire using the same conversion relation as for a bare wire.

Predicting the Effective Thermal Conductivity of Some Sand-Water Mixtures Used for Backfilling Materials of Ground Heat Exchanger (지중열교환기 뒤채움재로 사용되는 모래-물 혼합물의 열전도도 예측)

  • Sohn, Byong-Hu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.9
    • /
    • pp.614-623
    • /
    • 2008
  • This paper presents the results of a laboratory study on the thermal conductivity of and(silica, quartzite, limestone, sandstone, granite and two masonry sands)-water mixtures used for ground heat exchanger backfilling materials. Nearly 260 tests were performed in a thermal conductivity measuring system to characterize the relationships between the thermal conductivity of mixtures and the water content. The experimental results show hat the thermal conductivity of mixtures increases with increasing dry density and with increasing water content. The most widely used empirical prediction models for thermal conductivity of soils were found inappropriate to estimate the thermal conductivity of unsaturated sand-water mixtures. An improved model using an exponential relationship to compute the thermal conductivity of dry sands and empirical relationship to assess the normalized thermal conductivity of unsaturated sand-water mixtures is presented.

Predicting the Effective Thermal Conductivity of Sand-Water Mixtures Used for Grouting Materials (그라우팅 재료로 사용되는 모래-물 혼합물의 열전도도 예측)

  • Sohn, Byong-Hu;Lim, Hyo-Jae
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.761-768
    • /
    • 2008
  • This paper presents the results of a laboratory study on the thermal conductivity of sand(silica, quartzite, limestone, sandstone, granite and masonry sand)-water mixtures used in ground heat exchanger backfilling materials. Nearly 260 tests were performed in a thermal conductivity measuring system to characterize the relationships between the thermal conductivity of mixtures and the water content. The experimental results show that the thermal conductivity of mixtures increases with increasing dry density and with increasing water content. The most widely used empirical prediction models for thermal conductivity of soils were found inappropriate to estimate the thermal conductivity of unsaturated sand-water mixtures. An improved model using a exponential relationship to compute the thermal conductivity of dry sands and empirical relationship to assess the normalized thermal conductivity of unsaturated sand-water mixtures is presented.

  • PDF