• Title/Summary/Keyword: 비정상열유동

Search Result 64, Processing Time 0.02 seconds

Influence of a isolator in supersonic nozzle on thermal choking (초음속 노즐의 분리부가 열폐색에 미치는 영향)

  • Kim, Sangwoo;Kim, Youngcheol;Kim, Jangwoo
    • Journal of Energy Engineering
    • /
    • v.21 no.3
    • /
    • pp.237-242
    • /
    • 2012
  • This study presents numerical solutions of the two-dimensional Navier-Stokes equations for supersonic unsteady flow in a convergent-divergent nozzle with a isolator. The TVD scheme in generalized coordinates is employed in order to calculate the moving shock waves caused by thermal choking. We discuss on transient characteristics, unstart phenomena, fluctuations of specific thrust caused by thermal choking and effects of isolator. The adverse pressure gradient caused by heat addition brings about separation of the wall boundary layers and formation of the oblique shock wave that proceed to upstream. The proceeding speed of the oblique shock wave to upstream direction for the convergent-divergent nozzle with isolator is lower than that for the nozzle without isolator.

The Unsteady 2-D Numerical Analysis in a Horizontal Pipe with Thermal Stratification Phenomena (열성층현상이 존재하는 수평배관내에서의 비정상 2차원 수치해석)

  • Youm, Hag-Ki;Park, Man-Heung;Kim, Sang-Nung
    • Nuclear Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.27-35
    • /
    • 1996
  • In this paper, an unsteady analytical model for the thermal stratification in the pressurizer surge line of PWR plant has been proposed to investigate the temperature profile, flow characteristics, and thermal stress in the pipe. In this model, the interface level, between hot and cold fluid, is assumed to be a function of time while the other models had developed for time independent or steady state. The dimensionless governing equations are solved by using a SIMPLE (Semi-Implicit Method for Pressure Linked Equations) algorithm. The analysis result for an example shows that the maximum dimensionless temperature difference is about 0.78 between hot and cold sections of pipe wall and the maximum thermal stress by thermal stratification is calculated about 276 MPa at the dimensionless time 27.0 under given conditions.

  • PDF

A Study of Transonic Premixed Combustion in a Diverging Channel Using Asymptotic Analysis (점근해석을 이용한 확대형 채널 내의 천음속 예혼합 연소에 관한 연구)

  • Lee, Jang-Chang
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.8
    • /
    • pp.75-83
    • /
    • 2005
  • A steady transonic dilute premixed combustion in a diverging channel is investigated by using asymptotic analysis. This model explores the nonlinear interactions between the near-sonic speed of the flow, the small changes in geometry from a straight channel, and the small heat release due to the one-step first-order Arrhenius chemical reaction. The reactive flow is described by a nonhomogeneous transonic small-disturbance (TSD) equation coupled with an ordinary differential equation for the calculation of the reactant mass fraction in the combustible gas. Also the asymptotic analysis reveals the similarity parameters that govern the reacting flow problem. The results show the complicated nonlinear interaction between the convection, reaction, and geometry effects and its effect on the flow behavior.

가스 발생기를 이용한 수직발사 사출 시스템에 관한 해석적 연구

  • 변종렬;오종윤;황용석
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.28-28
    • /
    • 1999
  • 본 연구에서는 가스 발생기에서 발생되는 고온, 고압의 가스를 이용하여 유도탄을 수직 발사하는 사출 시스템에 대해 해석적 연구를 수행하였다. 사출 시스템에 의한 수직발사 방식은 발사관내에 설치된 가스 발생기에 의해 생성된 가스가 사출 실린더의 피스톤을 구동시켜, 피스톤에 연결된 유도탄을 요구되는 높이로 사출 시킨 후 유도탄이 점화되는 발사방식이다. 이러한 발사방식은 유도탄 자체의 부스터 발사방식에 비해 유도탄의 화염에 의한 영향이 적다. 현재 사출 시스템은 가스발생기, 가스 튜브, 사출 실린더와 피스톤으로 구성되어있다. 본 논문은 가스 발생기에서 사출 실린더까지의 내부 유동장을 일차원적으로 모델링하였고, 가스발생기, 가스튜브, 실런더 내의 유동과 열전달 과정 및 유도탄의 동적거동에 대한 미분방정식을 연립하여 4th-order Runge-Kutta 방법으로 계산하였다. 또한 가스튜브와 사출 실린더의 열전달 손실에 대하여 1차원 비정상 열전도 방정식의 수치적 계산을 통해 에너지 손실을 계산하였다. 특히 해석에 사용된 작동유체인 추진제 가스의 열학적 상태량은 온도 함수의 5차 다항식으로 표현하여 사용하였다. 이론적인 해석을 통해 사출 장치 시스템의 성능 요구조건과 신뢰성을 만족시키기 위한 가스발생기의 추진제 그레인 및 사출 시스템 설 계 조건을 도출하였다.

  • PDF

PlV Measurement of Channel Cavity Flow with Bottom Heat surface of Constant Heat Flux (일정 열유속의 하부 가열면을 갖는 채널캐비티 내부유동의 PIV 계측)

  • 조대환;김진구
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.4
    • /
    • pp.437-442
    • /
    • 1997
  • An experimental study was carried out in a channel cavity with square heat surface by visual¬ization equipment with Mach - Zehnder interferometer and laser apparatus. The image processing system consists of one commercial image board slit into a personal computer and 2-dimensional sheet light by Argon-Ion Laser with cylindrical lens and flow picture recording system. Instant simultaneous velocity vectors at whole field were measured by 2-D PIV system which adopted two¬frame grey-level cross correlation algorithm. Heat source was uniform heat flux(o.4W/cm$^2$, , O.8W/cm$^2$, 1.2W/cm$^2$). Obtained result showed various flow patterns such as kinetic energy distribution. Severe unsteady flow fluctuation within the cavity are remarkable and sheared mixing layer phenomena are also found at the region where inlet flow is collided with the counter-clockwise rotating main primary vortex. Photographs of Mach ~ Zehnder are also compared in terms of constant heat flux.

  • PDF

Numerical Analysis of Unsteady Heat Transfer for Location Selection of CPVC Piping (CPVC 배관 동파방지용 열선의 위치 선정을 위한 비정상 열전달 수치해석)

  • Choi, Myoung-Young;Choi, Hyoung-Gwon
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.33-39
    • /
    • 2015
  • In this paper, a numerical experiment was conducted to find out the optimal location of electrical heat trace for anti-freeze of water inside the CPVC pipe for fire protection. The unsteady incompressible Navier-Stokes equations coupled with energy equation were solved. Since the conduction equation of pipe was coupled with the natural convection of water, the analysis of conjugate heat transfer was conducted. A commercial code (ANSYS-FLUENT) based on SIMPLE-type algorithm was used for investigating the unsteady flows and temperature distributions in water region. From the present numerical experiment, it has been found that the vector field of water inside the PVC pipe is opposite to the case of steel because of the huge difference of material properties of the two pipes. Furthermore, it was found that the lowest part of the pipe was an optimal position for electrical heat trace since the minimum water temperature of the case was higher than those of the other cases.

표준원전 모의 열수력 종합실험장치의 개념설계 및 저온관 소형냉각재상실사고 예비해석

  • 배규환;문상기;박춘경;권태순;송철화;양선규;정문기
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.699-706
    • /
    • 1998
  • 한국원자력연구소에서는 원자력중장기연구의 일환으로 한국형 표준원전을 모의하는 종합열수력실증실험을 계획하고 있으며, 현재 실험장치에 대한 척도해석(Scaling Analysis), 예비해석(Scoping Analysis) 및 개념설계를 수행하고 있다. 본 논문에서는 영광 3/4호기를 대상으로 척도해석을 통하여 실험장치를 개념설계하고, 저온관 6인치 소형냉각재 상실사고에 대하여 예비해석을 수행한 결과를 보여준다. 개념설계된 실험장치는 높이비가 참조원자로와 동일하고, 체적비가 1/200이다. 실험장치의 개념설계는 이상유동에 대한 3단계 척도법을 적용하였으며, 개념설계의 타당성을 입증하기 위해 RELAP5/MOD3.1 코드를 사용하여 정상상태 및 저온관 6인치 소형냉각재 상실사고시 계통의 거동을 예비 계산하였다. 실험장치에 대한 예비해석결과 사고 거동이 참조원자로와 잘 일치하는 것으로 나타났다. 또한 수평관 및 주냉각재펌프의 척도기준이 사고의 진행과정에 영향을 미치는 중요한 인자로 밝혀졌다

  • PDF

Quasi-Transient Method for Thermal Response of Blunt Body in a Supersonic Flow (준-비정상해석 기법을 통한 초음속 유동 내 무딘 물체의 열응답 예측)

  • Bae, Hyung Mo;Kim, Jihyuk;Bae, Ji-Yeul;Jung, Daeyoon;Cho, Hyung Hee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.6
    • /
    • pp.495-500
    • /
    • 2017
  • In the boundary layer of supersonic or hypersonic vehicles, there is the conversion from kinetic energy to thermal energy, called aerodynamic heating. Aerodynamic heating has to be considered to design supersonic vehicles, because it induces severe heat flux to surface. Transient heat transfer analysis with CFD is used to predict thermal response of vehicles, however transient heat transfer analysis needs excessive computing powers. Loosely coupled method is widely used for evaluating thermal response, however it needs to be revised for overestimated heat flux. In this research, quasi-transient method, which is combined loosely coupled method and conjugate heat transfer analysis, is proposed for evaluating thermal response with efficiency and reliability. Defining reference time of splitting flight scenario for transient simulation is important on accuracy of quasi-transient method, however there is no algorithm to determine. Therefore the research suggests the algorithm with various flow conditions to define reference time. Supersonic flow field of blunt body with constant acceleration is calculated to evaluate quasi-transient method. Temperature difference between transient and quasi-transient method is about 11.4%, and calculation time reduces 28 times for using quasi-transient method.

A study on the flow induced vibration on a heat exchanger circular cylinder (열교환 단일 원관의 유동 유발 진동 특성에 관한 연구)

  • Ha, Ji Soo;Lee, Boo Youn;Shim, Sung Hun
    • Journal of Energy Engineering
    • /
    • v.24 no.3
    • /
    • pp.109-114
    • /
    • 2015
  • Heat exchanger tube array in a heat recovery steam generator is exposed to the hot exhaust gas flow and it could cause the flow induced vibration, which could damage the heat exchanger tube array. It is needed for the structural safe operation of the heat exchanger to establish the characteristics of flow induced vibration in the tube array. The researches for the flow induced vibration of typical heat exchangers have been conducted and the nondimensional PSD(Power Spectral Density) function with the Strouhal number, fD/U, had been derived by experimental method. The present study examined the results of the previous experimental researches for the nondimensional PSD characteristics by CFD analysis and the basis for the application of flow induced vibration to the heat recovery steam generator tube array would be prepared from the present CFD analysis. For the previous mentioned purpose, the present CFD analysis introduced a single circular cylinder and calculated with the unsteady laminar flow over the cylinder. The characteristics of vortex shedding and lift fluctuation over the cylinder was investigated. The derived nondimensional PSD was compared with the results of the previous experimental researches and the characteristics of lift PSD over a single circular cylinder was established from the present CFD study.

The Effect of Inferior Turbinectomy on Heat/Humidity Transfer Ability of the Nose (하비갑개수술이 비강의 열/습도 전달 특성에 미친 영향)

  • Chung, Kang-Soo;Chang, Ji-Won;Kim, Sung-Kyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.4
    • /
    • pp.419-424
    • /
    • 2012
  • In addition to respiration, the nose performs three other major physiological functions-air-conditioning, filtering, and smelling. On the basis of our experience in experimental investigations of nasal airflows in normal and abnormal nasal cavity models, airflows in the normal model and three artificially deformed models, which simulate the results of surgical treatments (inferior turbinectomy), are investigated by PIV and CFD. The left cavities of all three models are normal, and the right cavities are modified as follows: (1) excision of the head of the inferior turbinate, (2) resection of the lower fifth of the inferior turbinate, and (3) resection of almost the entire inferior turbinate. The use of high-resolution CT data and careful surface rendering of three-dimensional computer models with the help of an ENT doctor provide more sophisticated nasal cavity models. Nasal airflows for both normal and deformed cases are also compared.