• Title/Summary/Keyword: 비접촉 변위센서

Search Result 46, Processing Time 0.03 seconds

A Study of Noncontact Heartbeat and Respiration Detection Using the Doppler Radar (도플러 레이더를 이용한 비접촉 방식의 심박 및 호흡 검출에 관한 연구)

  • Shin, Jae-Yeon;Cho, Sung-Pil;Jang, Byung-Jun;Park, Ho-Dong;Lee, Yun-Soo;Lee, Kyoung-Joung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • In this paper, a 2.4 GHz doppler radar system consisting of a doppler radar sensor and a baseband module were designed to detect heart beat and respiration signal without direct skin contact. The doppler radar system emits RF signal of 2.4 GHz toward human chest, and then detects phase modulation of the reflected signal so as to investigate cardiopulmonary activities. The heartbeat and respiration signals acquired from I/Q channels of the doppler radar system are applied to the pre-processing circuit, the amplification circuit, and the offset circuit of the baseband module. The designed system was tested on mouse, rabbit and mankind, which have different range of heart rates and respiration signals, to evaluate detection accuracy of the system. ECG acquisition system and respiration transducer were used to generate the reference signal. In our experiments, a performance of detection were found to be high in the case that the subject stays still. In this paper, we confirmed that non-contact heart beat and respiration detection using the doppler radar has the possibility and limitation according to distance, cardiopulmonary activities, range of heart rates and respiration.

Development of a Non-contacting Capacitive Sensor for Measurement of ${\mu}{\textrm}{m}$-order Displacements (마이크로미터 변위 측정을 위한 비접촉식 전기용량 센서 개발)

  • 김한준;이래덕;강전홍;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.768-771
    • /
    • 2001
  • Non-contacting capacitive sensor, based on principle of the cross capacitor, for measuring of $\mu\textrm{m}$-order displacements have been fabricated and characterized. To overcome disadvantages of the existed capacitive sensors of parallel type with 2-electrodes and 3-electrodes, the developed new sensor was designed to have 4-electrodes, two of them used high and low electrode the other two used as guard electrodes, on a sapphire plate with diameter 17 mm and thickness 0.7 mm, and are symmetrically situated with a constant gap of 0.2 mm between the electrodes. This sensor can be used for measuring the distance between sensor and target not only the metallic but also non-metallic target without ground connection.

  • PDF

Development of a Non-contacting Capacitive Sensor Based on Thompson-Lampard Theorem for Measurement of ${\mu}m-order$ Displacements (Thompson-Lampard 정리를 적용한 마이크로미터 변위 측정을 위한 비접촉식 전기용량 센서 개발)

  • Kim, Han-Jun;Kang, Jeon-Hong;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.9
    • /
    • pp.443-448
    • /
    • 2006
  • Non-contacting capacitive sensor based on Thompson-Lampard theorem have been fabricated and characterized for measuring of 때 order displacements. To overcome disadvantages of the existed capacitive sensors of parallel plate type with 2-electrodes and 3-electrodes, the developed new sensor was designed to have 4-electrodes with a constant gap of 0.2mm between the electrodes. Two of the electrodes were used as a high potential electrode and a low one, the other two electrodes were used as guard electrodes. These electrodes were made from copper using RF sputtering system on a sapphire plate with diameter 17 mm and thickness 0.7 mm. This sensor can be used for measuring the distance not only between the sensor and metallic target connected to ground potential but also non-metallic target without ground connection.

Experimental Verification of Compressor Blade Aeromechanics (압축기 블레이드 Aeromechanics의 시험적 검증)

  • Choi, Yun Hyuk;Park, Hee Yong;Kim, Jee Soo;Shin, Dong Ick;Choi, Jae Ho;Kim, Yeong Ryeon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.240-244
    • /
    • 2017
  • Experimental verification in the rig test stage for component development is a vital link between the aeromechanical design and structural integrity validation process. Based on this premise, Non-Intrusive Stress Measuring System was adopted on the axial compressor test rig to measure the static and dynamic tip deflection of all blades by using tip-timing sensors. Through analyzing vibration characteristics, we evaluated the vibratory stresses seen on the blades fatigue critical location; detected synchronous resonances which are the source of High Cycle Fatigue (HCF) in blades; presented non-synchronous vibration response by aerodynamic excitation and individual blade mis-tuning patterns.

  • PDF

Multi-point Dynamic Displacement Measurements of Structures Using Digital Image Correlation Technique (Digital Image Correlation기법을 이용한 구조물의 다중 동적변위응답 측정)

  • Kim, Sung-Wan;Kim, Nam-Sik
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.11-19
    • /
    • 2009
  • Recently, concerns relating to the maintenance of large structures have been increased. In addition, the number of large structures that need to be evaluated for their structural safety due to natural disasters and structural deterioration has been rapidly increasing. It is common for the structural characteristics of an older large structure to differ from the characteristics in the initial design stage, and changes in dynamic characteristics may result from a reduction in stiffness due to cracks on the materials. The process of deterioration of such structures enables the detection of damaged locations, as well as a quantitative evaluation. One of the typical measuring instruments used for the monitoring of bridges and buildings is the dynamic measurement system. Conventional dynamic measurement systems require considerable cabling to facilitate a direct connection between sensor and DAQ logger. For this reason, a method of measuring structural responses from a remote distance without the mounted sensors is needed. In terms of non-contact methods that are applicable to dynamic response measurement, the methods using the doppler effect of a laser or a GPS are commonly used. However, such methods could not be generally applied to bridge structures because of their costs and inaccuracies. Alternatively, a method using a visual image can be economical as well as feasible for measuring vibration signals of inaccessible bridge structures and extracting their dynamic characteristics. Many studies have been conducted using camera visual signals instead of conventional mounted sensors. However, these studies have been focused on measuring displacement response by an image processing technique after recording a position of the target mounted on the structure, in which the number of measurement targets may be limited. Therefore, in this study, a model experiment was carried out to verify the measurement algorithm for measuring multi-point displacement responses by using a DIC (Digital Image Correlation) technique.

Evaluation of Fracture Behaviours of Cementitious Composites by High-velocity Projectile Impact (고속 비상체 충격에 의한 시멘트 복합체의 파괴거동 평가)

  • Min, Ji-Young;Cho, Hyun-Woo;Lee, Jang-Hwa;Kim, Sung-Wook;Moon, Jae-Heum
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.55-62
    • /
    • 2015
  • An importance of infrastructures' protection against crash or blast loading has been an emerging issue as structures are becoming much bigger and population densities in downtown are growing up. However, there exists no such a standard to evaluate the protection performance of construction material itself. Prior to building standards for protection assessment techniques, this study performed gas-gun propelled projectile impact tests with series of contact-type monitoring systems to investigate the applicability of each sensing type. Through the impact tests, failure modes and protection performances of both normal concrete and UHPC (Ultra High Performance Concrete) reinforced by steel fibers were also evaluated. The results showed that LVDT could be applicable for the impact test among contact-type sensors and UHPC with fibers had a remarkable potential to improve protection against impact loading.

Non-contacting OMM (On Machine Measurement) based on CAD Model (CAD 모델 기반 비접촉 기상 측정에 관한 연구)

  • 권세진;이정근;박정환;고태조;김선호
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.11
    • /
    • pp.134-141
    • /
    • 2003
  • An industrial product is designed and fabricated, followed by the inspection process in order to check whether it is dimensionally tolerable or not. The machining process produces a part such as a mold or die, in which the three-dimensional coordinate might be measured by a CMM (Coordinate Measuring Machine) for assessment of its dimension. It is not ignorable, however, that a CMM measurement requires a lot of operating time and cost, which has led to many studies on the OMM system. The OMM system can be categorized into contact and non-contact types, and each of which has its own strengths and weaknesses. Non-contacting types generally utilize structured lights, sounds or magnetic fields. Though they show rather poor performance in positional accuracy, the measuring speed is faster than the contacting probes. This paper presents the development of an OMM system based on a non-contacting laser displacement sensing apparatus and CAD model. The system is composed of software modules of center-aligning and measuring, which has been operated and verified on a NC machining center on a shop floor.

초고속 터보 분자펌프의 자기부상 회전 특성 해석

  • No, Seung-Guk;Gyeong, Jin-Ho;Park, Yong-Tae;Go, Deuk-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.97-97
    • /
    • 2012
  • 반도체 및 디스플레이 공정등에서 고진공 및 급 배기 환경을 제공하기 위하여 사용되는 터보분자펌프 (Turbomolecular Pump, TMP)는 다층의 회전깃을 갖는 로터를 회전시켜 분자를 배출시키는 방식을 사용하는 진공펌프이다. 또한 최근에는 디스플레이 및 반도체 공정에서 높은 진공도뿐만 아니라, 높은 배기속도를 요구하는 추세에 따라, 터보 펌프와 드래그 펌프부분을 동시에 가지고 있어 상대적으로 작동 진공도 영역이 넓은 복합 분자펌프(Compound Turbomolecular Pump, CMP)의 활용도가 넓어지고 있다. 이러한 분자펌프가 장시간의 고속회전에 적합하고, 베어링에서의 오염을 없앨 수 있는 비접촉 방식인 자기부상 방식이 주로 적용된다. 자기베어링 시스템은 하드웨어와 소프트웨어로 나누어질 수 있는데, 하드웨어는 회전하게 되는 블레이드 로터 및 자기베어링 로터, 모터 로터 등이 포함된 축과 고정되어 있는 자기베어링 코어와 코일, 변위센서 등의 펌프 하우징 부분, 또한 이를 제어하기 위한 전력 증폭 시스템 등의 기전적인 요소들이 이루어져 있다. 소프트웨어라 할 수 있는 제어시스템에 있어서 자기 베어링이 불안정한 특성을 갖는 개루프계를 갖고 있으므로 안정화를 위한 능동제어 시스템이 필수적이며 진동제어 등의 기능을 갖도록 적용된다. 따라서 이러한 복합분자펌프의 성능은 이러한 시스템을 구성하는 개별 요소의 성능과 이를 통합한 제어시스템의 성능이 결정한다고 할 수 있다. 본 논문에서는 현재 개발중인 2,500 l/s급의 자기부상형 고진공 복합분자펌프의 시작품에 대하여 고속회전의 안정성에 대한 연구를 수행한 내용을 보고하고 있다. 디지털 제어시스템을 적용한 시작품의 최대 26,000 rpm까지의 고속회전시의 회전 응답 및 진동 특성을 측정 분석하였으며, 로터의 고유진동수 및 진동 모우드를 분석하였다. 또한 연속 작동시의 발열특성과 각 부분의 온도와 회전 안정성과의 관계를 평가하였다.

  • PDF

초고속 터보 분자펌프의 자기부상 회전 안정성 연구

  • No, Seung-Guk;Gyeong, Jin-Ho;Park, Yong-Tae;Go, Deuk-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.117-117
    • /
    • 2012
  • 반도체 및 디스플레이 공정등에서 고진공 및 급 배기 환경을 제공하기 위하여 사용되는 터보 분자펌프(Turbomolecular Pump, TMP)는 다층의 회전깃을 갖는 로터를 회전시켜 분자를 배출시키는 방식을 사용하는 진공펌프이다. 또한 최근에는 디스플레이 및 반도체 공정에서 높은 진공도뿐만 아니라, 높은 배기속도를 요구하는 추세에 따라, 터보 펌프와 드래그 펌프부분을 동시에 가지고 있어 상대적으로 작동 진공도 영역이 넓은 복합 분자펌프(Compound Turbomolecular Pump, CMP)의 활용도가 넓어지고 있다. 이러한 분자펌프가 장시간의 고속회전에 적합하고, 베어링에서의 오염을 없앨 수 있는 비접촉 방식인 자기부상 방식이 주로 적용된다. 자기베어링 시스템은 하드웨어와 소프트웨어로 나누어질 수 있는데, 하드웨어는 회전하게 되는 블레이드로터 및 자기베어링 로터, 모터 로터 등이 포함된 축과 고정되어 있는 자기베어링 코어와 코일, 변위센서 등의 펌프 하우징 부분, 또한 이를 제어하기 위한 전력 증폭 시스템 등의 기전적인 요소들이 이루어져 있다. 소프트웨어라 할 수 있는 제어시스템에 있어서 자기베어링이 불안정한 특성을 갖는 개루프계를 갖고 있으므로 안정화를 위한 능동제어 시스템이 필수적이며 진동 제어 등의 기능을 갖도록 적용된다. 따라서 이러한 복합분자펌프의 성능은 이러한 시스템을 구성하는 개별 요소의 성능과 이를 통합한 제어시스템의 성능이 결정한다고 할 수 있다. 본 논문에서는 현재 개발중인 2,500 l/s급의 자기부상형 고진공 복합분자펌프의 시작품에 대하여 고속회전의 안정성에 대한 연구를 수행한 내용을 보고하고 있다. 디지털 제어시스템을 적용한 시작품의 최대 26,000 rpm 까지의 고속회전시의 회전 응답 및 진동 특성을 측정 분석하였으며, 로터의 고유진동수 및 진동 모우드를 분석하였다. 또한 연속 작동시의 발열특성과 각 부분의 온도와 회전 안정성과의 관계를 평가하였다.

  • PDF

Tension Measurement of Stay Cables in Consideration with Image Including Vehicle (차량이 포함된 이미지를 고려한 사장재 케이블의 장력 측정 )

  • Sung-Wan Kim;Dong-Uk Park;Jin-Soo Kim;Seung-Su Park;Jae-Bong Park
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.2
    • /
    • pp.58-66
    • /
    • 2023
  • In this study, cable tension was measured using the vibration method, and a vision-based system was applied as a sensor to measure the displacement response of a cable in a non-contact method. In the vision-based system, the camera is installed in a location that considers the target structure and the field of view of the camera. However, it can be difficult to recognize the control points required to measure the displacement response of a structure as the target structure and other structures such as vehicles may be included in the image at the intended installation location. In this study, a distorted image including a vehicle shows inaccurate results in image analysis due to the installation position of the vision-based system. Accordingly, the image including the vehicle was eliminated by calculating the similarity between the two images. To verify the validity of the method of estimating the cable tension of cable-stayed bridges using the proposed method, the vibration method was applied to cable-stayed bridges in service to measure the tension.