• 제목/요약/키워드: 비저항이

Search Result 5,041, Processing Time 0.038 seconds

Optimum Monitoring Parameters for the Safety of Mechanical Seals (미캐니컬 씰의 안전운용 감시를 위한 최적 계측인자)

  • Soon-Jae Lim;Man-Yong Choi
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.4
    • /
    • pp.214-219
    • /
    • 1997
  • The mechanical seals, which are installed in rotating machines like pump and compressor, are generally used as sealing devices in the many fields of industries. The failure of mechanical seals such as leakage, crack, breakage, fast and severe wear, excessive torque, and squeaking results in big problems. To identify abnormal phenomena on mechanical seals and to propose the proper monitoring parameter for the failure of mechanical seals, sliding wear experiments were conducted. Acoustic emission, torque, and temperature were measured during experiments. Optical microstructure was observed for the wear processing after every 10 minute sliding at rotation speed of 1750 rpm and scanning electron microscopy was also observed. Except for the initial part of every experiment, the variation of acoustic emission was well coincided with torque variation during the experiments. This study concludes that acoustic emission and torque are proper monitoring parameters for the failure of mechanical seals. The intensity of acoustic emission signals is measured in root mean square voltage. Temperature of sealing face will be used as a parallel parameter for increasing the reliability of monitoring system.

  • PDF

Design of a Stainless Steel Insert for Mechanical Joining of Long Fiber-reinforced Composite Structures (장섬유강화 복합재료 구조물의 기계적 접합을 위한 스테인레스 강 인서트 설계)

  • Lee, Sung-Woo;Chang, Seung-Hwan
    • Composites Research
    • /
    • v.31 no.4
    • /
    • pp.139-144
    • /
    • 2018
  • Long Fiber-reinforced composites have advantages of excellent production efficiency and formability of complex shapes compared to conventional continuous fiber reinforced composite materials. However, if we need to make complicated composite shapes or to assemble parts made of different materials, a variety of joining methods are needed. In general, long fiber prepreg sheet (LFPS) contains mold release agent to facilitate demolding after thermoforming. Therefore, mechanical fastening is required in addition to the adhesive bonding to get proper joining strength. In this study, we proposed a stainless steel insert for co-cure bonding which cures LFPS and bonds the stainless steel insert through thermoforming process. The wing of the insert which is spread during the thermoforming process induces adhesion and mechanical wedging effect and serves as a hook to resist the pulling force. The burn-out method was used to confirm the unfolded state of the stainless steel insert wings inserted into the composite material. The static pull-out test was performed to quantitatively evaluate the joining strength. From these experimental results, the condition which guarantees the most appropriate joining strength was derived.

An Analysis on the Bleeding Effect of SCW Ground Heat Exchanger using Thermal Response Test Data (열응답시험 데이터를 이용한 SCW형 지중열교환기 블리딩 효과 분석)

  • Chang, Keun-Sun;Kim, Min-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.512-520
    • /
    • 2020
  • Recently, the applications of the standing column well (SCW) ground heat exchanger (GHX) have increased significantly in Korea as a heat transfer mechanism of ground source heat pump systems (GSHP) because of its high heat capacity and efficiency. Among the various design and operating parameters, bleeding was found to be the most important parameter for improving the thermal performance, such as ground thermal conductivity and borehole thermal resistance. In this study, a bleeding analysis model was developed using the thermal response test data, and the effects of bleeding rates and bleeding locations on the thermal performance of anSCW were investigated. The results show that, when the ground water flows into the top of anSCW, the time variation of circulating water temperature decreased with increasing bleeding rate, and the ground thermal conductivity increases by as much as 179% with a 30% bleeding rate. When the ground water flows into the bottom of the SCW, the circulating water temperatures become almost constant after the increase in the beginning time because the circulating water exchanges heat with the ground structure before mixing with the ground water at the bottom.

Impedance-matching Method Improving the Performance of the SAW Filter (탄성표면파 필터의 성능 개선을 위한 임피던스 정합의 해석적 방법)

  • 이영진;이승희;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.69-75
    • /
    • 2001
  • In this paper, a fast and easy impedance matching method, which could give the impedance matching component for the general 1 or 2-port network was introduced. First, the entire network structure was defined which consists of the network part to be matched and the impedance matching part composed of inductors and capacitors. Next, the transmission matrix and input and output impedances of the entire network from the terminal impedance conditions were calculated, then the exact solutions for the matching components were obtained. To verify the efficiency of this method, this method was applied to the CDMA If band withdrawal weighted SAW transversal filter, and investigated the effects of the impedance matching before and after, through the simulation and experiment. As the result, the performance of a fractional bandwidth of 1.2%, insertion loss of 29 dB, and VSWR of 80 have improved to a factional bandwidth of 1.8%, insertion loss of 9 dB, VSWR of 3 at 85.38 MHz center frequency. The result shows that this impedance matching method could be used in the SAW devices and other types of 1 or 2-port network.

  • PDF

Hot Tolerance Assessment of Sedum spp. for Extensive Green Roof System (저관리·경량형 옥상녹화를 위한 세덤류의 내서성 평가)

  • Zhao, Hong-Xia;Son, Hee-Jun;Kang, Tai-Ho
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.6
    • /
    • pp.180-189
    • /
    • 2012
  • This study was carried out to suggest an experiment based for selecting Sedum, which can adapt well with heat tolerance in extensive green roof system. The heat tolerance of Sedum subject to laboratory high temperature treatment and heat processing time were evaluated using electrolyte leakage, chlorophyll content and regrowth test, and the relation between soil water content and heat tolerance were researched. Logistic model of nonlinear regression analysis was used to evaluate the lethal temperatures that were predicted with the range of $45.0{\sim}48.1^{\circ}C$(soil water content 5%), $47.5{\sim}49.3^{\circ}C$(10%), $48.6{\sim}52.8^{\circ}C$(15%) in 6-hours high-temperature treatment. The higher the soil water content, the stronger the heat resistance property of Sedum. there is. The higher the treatment temperature, the lower the chlorophyll content, and the less the soil water content, the faster the chlorophyll decomposition. The order of hot-temperature resistance was S. reflexum>S. takevimense>S. middendorffianum>S. album>S. sieboldii>S. spurium when soil water content was 5%. The order of hot-temperature resistance was S. album>S. reflexum>S. spurium>S. takevimense>S. middendorffianum>S. sieboldii when soil water content was 15%. The more of soil water content, S. album, S. reflexum, S. spurium had stronger tolerant of hot temperature. These results were consistent with those from the regrowth test and the heat tolerance tested by electrolyte leakage evaluation.

Study on Wet chemical Etching Characterization of Zinc Oxide Film for Transparency Conductive Oxide Application (투명 전도성 산화물 전극으로의 응용을 위한 산화아연(ZnO) 코팅막의 습식 식각 특성연구)

  • Yoo, Dong-Geun;Kim, Myoung-Hwa;Jeong, Seong-Hun;Boo, Jin-Hyo
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.1
    • /
    • pp.73-79
    • /
    • 2008
  • In order to apply for transparent conductive oxide(TCO), we deposited ZnO thin films on the glass at room temperature by RF magnetron sputtering method. Deposition conditions for high transmittance and low resistivity were optimized in our previous studies. Under the deposition condition with the RF power of 200 W, target to substrate distance of 30 mm and working pressure of 5 mTorr, highly conductive($7.4{\times}10^{-3}{\Omega}cm$) and transparent(over 85%) ZnO films were prepared. Highly oriented ZnO film in the [002] direction were obtained with specifically designed ZnO targets. Systematic study on dependence of deposition parameters on electrical and optical properties of the as-grown ZnO films were mainly investigated in this work. And for application tests using these films as transparent conductive oxide anodes, wet chemical etching behaviors of ZnO films were also investigated using various chemicals. Wet-chemical etching behavior of ZnO films were investigated using various acid solutions. The concentrations of these different acid solutions were controlled to study the etching shapes and etching rate. ZnO films were anisotropically etched at various concentrations and wet etching led to crater-like surface structure. Also we firstly found that the etching rate and etching shapes of ZnO films strongly depended on the etchant concentrations (i.e. pH) and the etching rate is exponentially decreased with increasing pH values regardless of the acid etchants.

Thermoelectric Properties of the Hot-Pressed ($Pb_{1-x}Sn_x$)Te Fabricated by Mechanical Alloying (기계적 합금화 공정으로 제조한($Pb_{1-x}Sn_x$)Te 가압소결체의 열전특성)

  • Lee, Jun-Su;Choe, Jae-Sik;Lee, Gwang-Eung;Hyeon, Do-Bin;Lee, Hui-Ung;O, Tae-Seong
    • Korean Journal of Materials Research
    • /
    • v.8 no.11
    • /
    • pp.1055-1060
    • /
    • 1998
  • Thermoelectric properties of ($Pb_{1-x}Sn_x$)Te ($0\leq{x}\leq{0.4}$) alloys, fabricated by mechanical alloying and hot pressing, were investigated with variation of the SnTe content. For the hot-pressed PbTe and ($Pb_{0.9}Sn_{0.1}$)Te. transition from p-type to n-type occurred at $200^{\circ}C$ and $300^{\circ}C$, respectively. However, the specimens containing SnTe more than 0.2mole exhibited p-type conduction up to 450'C. In extrinsic conduction region, the Seebeck coefficient and electrical resistivity of the hot-pressed ($Pb_{1-x}Sn_x$)Te decreased with increasing the SnTe content. The temperature at which the hot-pressed (Pbl-,Sn,)Te exhibited a maximum figure-of-merit was shifted to higher temperature with increasing the SnTe content The hot-pressed (Pbo ,Sno dTe exhibited a maximum figure-of-merit of $0.68\times10_{-3}/K$ at $200^{\circ}C$.

  • PDF

Detection and Distribution of the Pathogenic Bioagent Aeromonas (Gamma-Proteobacteria) in Water Supplies of Seoul (서울시 상수계통에서 병원성균 Aeromonas (감마-프로테오박테리아) 분포연구)

  • Lee, Eun-Sook;Lee, Mok-Young;Han, Sun-Hee;Ka, Jong-Ok
    • Korean Journal of Microbiology
    • /
    • v.43 no.2
    • /
    • pp.106-110
    • /
    • 2007
  • The detection and distribution of Aeromonas in water supplies were investigated by using the USEPA Method 1605. Water samples were collected from the Han River, finished waters and tap waters supplied from Water Treatment Plants in Seoul monthly from July 2002 to December 2003. Aeromonas species in each water sample were quantified based on the development of yellow colonies on the surface of membrane filter using a selective medium (Ampicillin-Dextrin Agar with Vancomycin). The Quality Control (QC) for this study met the acceptance criteria of Method 1605. The concentrations of Aeromonas species in surface water samples ranged from $1.0{\times}10^{0}\;to\;9.8{\times}10^{3}\;CFU/ml$. Aeromonas species were found only in one tap water sample with concentration of 1 CFU/500 ml. No Aeromonas species were found in any finished water samples. Aeromonas species detected here were identified as A. salmonicida(51%), A. caviae(4.7%), A. schubertti(3.4%), A. sobria(3.8%), A. hydrophila(2.1%), and A. ichithiosmia(0.4%). A. salmonicida was the dominant species, which is of no significance to human health. Chlorine resistance of A. salmonicida was evaluated and as a result, 99.99% of A. salmonicida decreased after 30 seconds exposure at residual free chlorine 0.2 mg/L. These suggest that the waters supplied in Seoul may be safe against the pathogenic agent Aeromonas.

Growth and Physiological Responses of Shade Intolerant and Intermediate Tree Seedlings to Enhanced UV-B Radiation (자외선(紫外線)-B 증가조사(增加照射)에 대한 양수(陽樹)와 중성수(中性樹) 유묘(幼苗)의 생장(生長)과 생리적(生理的) 반응(反應)에 관한 연구(硏究))

  • Kim, Jong Jin;Hong, Sung Gak
    • Journal of Korean Society of Forest Science
    • /
    • v.88 no.4
    • /
    • pp.469-476
    • /
    • 1999
  • This study was carried out to investigate the growth and physiological response of shade intolerant and intermediate tree seedlings to enhanced UV-$B_{BE}$(biologically effective UV-B) radiation. The seedlings of Betula platyphylla var. japonica Hara(shade intolerant species) and Fraxinus rhynchophylla Hance(shade intermediate species) were treated with one of the three levels of UV-$B_{BE}$ dosages - ambient UV-$B_{BE}$, ambient+3.2, and ambient+$5.2\;KJ\;m^{-2}day^{-1}$) for 14 weeks in the field condition. Height and root collar diameter growth, leaf area, and biomass production of the seedlings of two species were reduced by enhanced UV-B radiation. Leaf stomatal resistance to water vapor of the F. rhynchophylla seedling was increased by the UV-B increment. The reductions in total chlorophyll and carotenoid were more apparent in the F. rhynchophylla than B. platyphylla seedling. There was no statistically significant changes in the concentration of UV-B absorbing compound($A_{300}$) in the leaves of the two species among the UV-B treatment. However the $A_{300}$ tented to be increased in F. rhynchophylla by enhanced UV-B radiation. These results indicate that the growth and the physiological and biochemical responses between B. platyphylla and F. rhynchophylla were different to enhanced UV-B environment.

  • PDF

A Study on the Standard Test Method for Thermal Resistance of Military Textile Thermal Insulator for Winter Season (방한을 목적으로 하는 군용 섬유제품 충전재의 보온성 시험방법에 대한 표준화 연구)

  • Yeo, Yong-heon;Hong, Seong-don;Lee, Min-hee;Kim, Kyung-pil;Chung, Il-han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.492-500
    • /
    • 2018
  • The performance evaluation of cold weather clothing is mainly carried out with thermal resistance. However, the results of the revised test method regarding the same specimen were decreased compare to previous one. In addition, there were deviations of the results among the authorized testing institutes according to the different interpretation of the KS test method. This makes it a considerable difficulty to the quality assurance of combat supplies. The purpose of this study is to minimize the variation of the results before and after the revision by analyzing the cause of the decrease in the heat insulation rate according to the revised test method. For this purpose, the difference between the test conditions before and after the revision of KS is analyzed and the possible results are reviewed. In addition, we want to minimize the result deviation between testing laboratories by analyzing the cause of the result deviation between test laboratories according to arbitrary interpretation of the standard. Based on this, we propose a standardized test method to prevent the decrease of the heat insulation rate by checking the pre-revision test method and the condition with the least deviation.