• Title/Summary/Keyword: 비열 영향

Search Result 79, Processing Time 0.029 seconds

Changes in Quality of Low Salt Fermented Anchovy by High Hydrostatic Pressure Treatment (초고압처리에 의한 저염 멸치젓의 품질 변화)

  • Lim, Sang-Bin;Yang, Moon-Sik;Kim, Soo-Hyun;Mok, Chul-Kyoon;Woo, Gun-Jo
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.111-116
    • /
    • 2000
  • Effects of ultra-high pressure treatment on viable cell count and quality characteristics of low salt fermented anchovy under different operating conditions such as pressure$(200{\sim}500\;MPa)$, temperature$(20{\sim}50^{\circ}C)$ and treatment time$(5{\sim}20\;min)$ were investigated. Viable cell count decreased gradually with the increase of pressure and suddenly at 400 MPa. It also decreased by seven folds at $50^{\circ}C$ and logarithmically with the increase of treatment time. Peroxide value increased with the increase of pressure, temperature and treatment time, and temperature played a major role. Thiobarbituric acid value was higher by two folds in samples treated than in the untreated regardless of any conditions investigated. Volatile basic nitrogen was almost the same in all samples except the one at $50^{\circ}C$. The sample treated at greater than $30^{\circ}C$ under high hydrostatic pressure indicated higher value in amino nitrogen. Treatment at $20^{\circ}C/300$ MPa/15 min showed greater reductions in viable cell counts, remaining better quality of low salt fermented anchovy.

  • PDF

A Numerical Study of the Effects of Land Characteristics on the Air Cooling (지표면 특성에 따른 대기 냉각 효과에 관한 수치적 연구)

  • An, Jae-Ho;Kim, Tae-Wan;Lee, Sang-Eun
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.4
    • /
    • pp.264-271
    • /
    • 2004
  • A three-dimensional numerical mesoscale model by Pielke's estimation (University of Virginia Mesoscale Model, UVMM) was applied to investigate the effects of land characteristics including land-humidity, land-roughness and land-albedo on some micro-climatic coefficients and the air cooling capacity. The results indicated that land-characteristics exposed a significant effect on air cooling. Air cooling effects between in urban and agricultural areas were compared and the effects were much higher in agricultural area. Air cooling effects of weed species were different and when converted into economic values by diesel oil price the effects were ranged from 411 to 816 Won/plant.

GIS spatial D/B formation of geothermal data and Distribution of Heat Flow of Korea (한국의 지열자료 GIS 공간 D/B 구축과 지열류량 분포)

  • Kim, Hyoung-Chan;Lee, Young-Min;Park, Jeong-Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.459-460
    • /
    • 2006
  • 현재 남한의 지열류량 측정값으로는 총 363개 지점의 자료가 측정 및 수집되어 있다. 이것은 Mizutani et at. (1970), 장정진 외(1970), 그리고 서정희(1976) 등의 자료, 총 35개의 자료도 추가된 것이다. 1989년 이후부터 측정된 지열류량 자료는 217개 자료이며(임정웅 외, 1989; 임정웅 외, 1996; Lim and Kim, 1997; 염병우 외, 1997), 모두 직접 측정한 것이나, 1989년 이후 보고된 지열류량 자료에 약간의 오류가 있어 이번 연구에서 수정 보완하였다. 또한 과거의 자료 35개 자료는 이미 지열류량 측정치가 논문화 되어 있는 것으로 암석시료는 없다 1989년 이후 2004년까지 자료 217개 2005년도 추가 자료 111개의 지열류량 자료는 암석시료도 있으며, 측정기기가 서로 달라 오차가 있을 수 있어 서로 보정을 해야 할 필요가 있어 시추공 주변 암석을 새로 수집해서 신장비로 다시 측정 보정하였다. 지열류량 D/B 구축은 각 자료의 일련번호, 고유번호 (Sn.), 위경도 좌표 (longitude, lattitude), 암석의 열전도도(thermal conductivity), 지온경사 (thermal gradient), 지열류량 (heat flow)등으로 구성되어 있다. 지열류량 자료 공간 데이터베이스는 점 속성을 가지며 자료형태는 각종 소프트웨어와 호환성이 좋은 shape 파일 형태로 작성하였다. 또만 최근 천부 토양 및 암석 열물성을 이용한 냉난방시스템 즉, Heat Pump System 설계를 위하여 반드시 들어가야 하는 요소인 열확산율, 공극율, 밀도, 비열 등 열물성 특성을 추가하여 GIS 공간 D/B구축하였다. 대륙붕 자료 4개 자료를 제외하고 359개의 지열류량 자료를 이용하여 한반도 남부, 즉 남한의 지열류량 분포도를 작성 분석해 본 결과(그림 1), 우리나라의 지열류량 이상대는 아산만 주변, 보령, 유성, 진안, 울진, 포항, 부산 지역과 포천, 속초, 충주, 수안보 등 지역에서 나타난다 이러한 이상대 주변에는 대개 온천이 발달되어 있었거나 새로 개발되어 있는 곳이다. 온천에 이용하고 있는 시추공의 자료는 배제하였으나 온천이응으로 직접적으로 영향을 받지 않은 시추공의 자료는 사용하였다 이러한 온천 주변 지역이라 하더라도 실제는 온천의 pumping 으로 인한 대류현상으로 주변 일대의 온도를 올려놓았기 때문에 비교적 높은 지열류량 값을 보인다. 한편 한반도 남동부 일대는 이번 추가된 자료에 의해 새로운 지열류량 분포 변화가 나타났다 강원 북부 오색온천지역 부근에서 높은 지열류량 분포를 보이며 또한 우리나라 대단층 중의 하나인 양산단층과 같은 방향으로 발달한 밀양단층, 모량단층, 동래단층 등 주변부로 NNE-SSW 방향의 지열류량 이상대가 발달한다. 이것으로 볼 때 지열류량은 지질구조와 무관하지 않음을 파악할 수 있다. 특히 이러한 단층대 주변은 지열수의 순환이 깊은 심도까지 가능하므로 이러한 대류현상으로 지표부근까지 높은 지온 전달이 되어 나타나는 것으로 판단된다.

  • PDF

Nonthermal Pasteurization of Lactic acid bacteria by High Intensity Light Pulse (광 펄스에 의한 젖산균의 비열 살균)

  • Cho, Hyung-Yong;Shin, Jung-Kue;Song, Young-Ae;Yoon, Seon-Joo;Kim, Joong-Man;Pyun, Yu-Ryang
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.631-636
    • /
    • 2002
  • Lethality of high intensity light pulse on the pre-determined microbial populations has been investigated. Prior to the treatment, Lactobacillus plantarum, Lactobacillus brevis, Leuconostoc mesenteroides and Pediococcus pentosaceus were cultivated separately onto the surface of Lactobacilli MRS agar. Pre-determined microbial populations were applied to the test media and these sample were exposed to high intense light source with an exposure time ranging from 1 to $2500\;{\mu}s$. Results showed that at least 200 light pulses of $1\;{\mu}s$ duration were required to reduce L. Plantarum cells by 90% at 25 kV, the greater the number of light pulses, the larger the reduction in viable cell numbers. Viable cells of L. plantarum and the others were reduced by more than 5 and 6 log cycles at the upper exposure level of $750\;{\mu}s$, respectively. These study shows that pulsed light emissions can significantly reduce populations of lactic acid bacteria on exposed surface with exposure times. Killing efficiency for L. plantarum significantly increased with decreasing the distance between the lamp and the surface of samples.

Constructing Topographies of EMF Risks from Underground Power Lines (전자파 위험 지형도의 상이한 구성: 지중 송전선로 위험 논쟁을 중심으로)

  • Kim, JooHui
    • Journal of Science and Technology Studies
    • /
    • v.19 no.3
    • /
    • pp.119-166
    • /
    • 2019
  • The risk of electromagnetic field(EMF) from power lines has been heavily disputed whenever high-voltage power line towers were built in South Korea. Local communities and civic groups had regarded burying the lines in the ground as an alternative to building power line towers. In 2014, however, when an elementary school science teacher reported the results of EMF measurements over the underground power lines to the Asian Citizens' Center for Environment and Health (ACCEH), the risk controversy over underground power lines took a whole new turn. The level of EMF from underground power lines turned out to be higher, and therefore more harmful than that from power line towers. In the debates that took place from then on over the EMF risk, ACCEH and NIER(National Institute of Environmental Research) presented conflicting topographies of EMF risk. This paper examines measuring practices of ACCEH and NIER by analyzing the measuring sites, measuring devices, and measuring heights chosen by each organization. This paper further examines how ACCEH and NIER mobilized various standards(EMF exposure limit, measurement guideline, categorization of carcinogens) differently. This controversy on the EMF from underground power lines of Seoul has raised concerns on the non-thermal effects of EMF in the long-term exposure and has led people to question whether burying the power lines is the safe alternative to building power line towers. Furthermore, this suggests conflicting answers on whether Seoul, where 90 % of transmission lines were already buried, is a safely managed place or not.

Applying Rosen-type PZT plasma generation device for medical applications (로젠형 압전변압기를 적용한 의료융합 플라즈마기기)

  • Lee, Kang-yeon;Jung, Byung-Geun;Park, Jeong-sook;Park, Ju-Hoon;Jeong, Byeong-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.1
    • /
    • pp.243-250
    • /
    • 2021
  • In the medical field, applications of plasma are applied sterilize instruments mainly but with the advent of bio-plasma technology, the scope of application is expanding. Recently, In addition, high-density miniaturization with handheld is required for sophisticated procedures when irradiated directly or treated with non-standard conditions. Rosen-type PZT is a device with a structure that generates high voltage plasma by achieving voltage transformation through electro-mechanical coupling using piezoelectric effect.and is used in portable plasma generating devices as an advantage to increase energy density relatively. In this paper, Rosen-type PZT was modeled using equivalent circuits and was carried out and a plasma generating device for medical application was designed and prototype tested. Prototype plasma generating device generates an output voltage of 5.8 kV with 12V input power and is designed to operate at high voltage by applying the half-bridge topology power converter. The results of the study confirmed the availability of various medical devices, such as plasma jets or direct exposure equipment.

An Experimental Study for Characteristics Evaluation of Cement Mortar Using Infrared Thermography Technique (적외선 화상기법을 이용한 시멘트 모르타르 특성의 실험적 평가)

  • Kwon, Seung-Jun;Maria, Q. Feng
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1A
    • /
    • pp.53-59
    • /
    • 2010
  • Recently, NDTs (Non-Destructive Techniques) using infrared camera are widely studied for detection of damage and void in RC (reinforced concrete) structures and they are also considered as an effective techniques for maintenance of infrastructures. The temperature on concrete surface depends on material and thermal properties such as specific heat, thermal conductivity, and thermal diffusion coefficient. Different porosity on cement mortar due to different mixture proportions can show different heat behavior in cooling stage. The porosity can affect physical and durability properties like strength and chloride diffusion coefficient as well. In this paper, active thermography which uses flash for heat induction is utilized and thermal characteristics on surface are evaluated. Samples of cement mortar with W/C (water to cement ratio) of 0.55 and 0.65 are prepared and physical properties like porosity, compressive strength, and chloride diffusion coefficient are evaluated. Then infrared thermography technique is carried out in a constant room condition (temperature $20{\sim}22^{\circ}C$ and relative humidity 55-60%). The mortar samples with higher porosity shows higher residual temperature at the cooling stage and also shows reduced critical time which shows constant temperature due to back wall effect. Furthermore, simple equation for critical time of back wall effect is suggested with porosity and experimental constants. These characteristics indicate the applicability of infrared thermography as an NDT for quality assessment of cement based composite like concrete. Physical properties and thermal behavior in cement mortar with different porosity are analyzed in discussed in this paper.

A Numerical and Experimental Study for Fry-drying of Various Sludge (슬러지 유중 건조에 대한 전산 해석 및 실험적 연구)

  • Shin, Mi-Soo;Kim, Hey-Suk;Kim, Byeong-Gap;Hwang, Min-Jeong;Jang, Dong-Soon;Ohm, Tae-In
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.4
    • /
    • pp.341-348
    • /
    • 2010
  • The basic principle of fry drying process of sludge lies in the rapid pressure change of sludge material caused by the change of temperature between oil and moisture due to the difference of specific heat. Therefore, the rapid increase of pressure in drying sludge induces the efficient moisture escape through sludge pores toward heating oil media. The object of this study is to carry out a systematic investigation of the influence of various parameters associated with the sludge fry drying processes on the drying efficiency. To this end, a series of parametric experimental investigation has been made together with the numerical calculation in order to obtain typical drying curves as function of important parameters such as drying temperature, sludge diameter, oil type and sludge type. In the aspect of frying temperature, especially it is found that the operation higher than $140^{\circ}C$ was favorable in drying efficiency regardless of type of waste oil employed in this study. The same result was also noted consistently in the investigation of numerical calculation, that is, in that the sludge particle drying was efficiently made over $140^{\circ}C$ irrespective of the change of particle diameter. As expected, in general, the decrease of diameter in sludge was found efficient both experiment and numerical calculation in drying due to the increased surface area per unit volume. In the investigation of oil type and property, the effect of the viscosity of waste oil was found to be more influential in drying performance. In particular, when the oil with high viscosity, a visible time delay was noticed in moisture evaporation especially in the early stage of drying. However, the effect of high viscosity decreased significantly over the temperature of $140^{\circ}C$. There was no visible difference observed in the study of sludge type but the sewage sludge with a slightly better efficiency. The numerical study is considered to be a quite useful tool to assist in experiment with more detailed empirical modeling as further work.

Thermal Properties of Granite from the Central Part of Korea (한국 중부 지역의 화강암 열물성)

  • Kim, Jongchan;Lee, Youngmin;Koo, Min-Ho
    • Economic and Environmental Geology
    • /
    • v.47 no.4
    • /
    • pp.441-453
    • /
    • 2014
  • Thermal and physical properties were measured on 206 Jurassic granite samples obtained from three boreholes in the central part of Korea. Thermal conductivity(${\lambda}$), thermal diffusivity(${\alpha}$), and specific heat(Cp) were measured in a laboratory; the average values are ${\lambda}$=2.813 W/mK, ${\alpha}=1.296mm^2/sec$, and Cp=0.816 J/gK, respectively. In addition, porosity(${\phi}$), and dry and saturated density(${\rho}$) were measured in the laboratory; the average values are ${\phi}$=0.01, ${\rho}(dry)=2.662g/cm^3$ and ${\rho}(saturated)=2.67g/cm^3$, respectively. Thermal diffusivity of 10 granite samples were measured with increasing temperature from $25^{\circ}C$ to $200^{\circ}C$. In this study, we found that thermal diffusivity at $200^{\circ}C$ is about 30% lower than thermal diffusivity at $25^{\circ}C$. In correlation analysis, thermal conductivity increases with increasing thermal diffusivity. However, thermal conductivity does not show good correlation with porosity and density. Consequently, we know that thermal conductivity of granite would be more influenced by mineral composition than by porosity. We also derived ${\rho}=-2.393{\times}{\phi}+2.705$ from density and porosity data. XRD and XRF analysis were performed to investigate effects of mineral and chemical composition on thermal conductivity. From those results, we found that thermal conductivity increases with increasing quartz and $SiO_2$, and decreases with increasing albite and $Al_2O_3$. Regression analysis using those mineral and chemical composition were carried out ; we found $K=0.0294V_{Quartz}+1.93$ for quartz, $K=0.237W_{SiO_2}-14.09$ for $SiO_2$, and $K=0.053W_{SiO_2}-0.476W_{Al_2O_3}+6.52$ for $SiO_2$ and $Al_2O_3$. Specific gravities were measured on 10 granite samples in the laboratory. The measured specific gravity depends on chemical compositions of granite. Therefore, specific gravity can be estimated by the felsic-mafic index(F) that is calculated from chemical composition. The estimated specific gravity ranges from 2.643 to 2.658. The average relative error between measured and estimated specific gravities is 0.677%.