• Title/Summary/Keyword: 비열 영향

Search Result 79, Processing Time 0.025 seconds

Characteristics of Non-thermal Plasma Generation by Duty Ratio and Frequency of Pulse Voltage (펄스고전압의 시비율과 주파수에 따른 비열플라즈마 발생특성)

  • Park, Seung-Lok;Kim, Jin-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.146-150
    • /
    • 2004
  • The effects on non-thermal plasma generation by duty Ratio and frequency of pulse voltage were investigated experimentally. For these, a new type of non-thermal plasma generator with mesh electrode was manufactured and it was possible to generate the surface and silent discharge simultaneously by new type of non-thermal plasma generator. Duty ratio and frequency were selected as main parameters to control the movement of electron which is mainly related to the non-thermal plasma generation. The characteristics of non-thermal plasma generation were investigated indirectly by measuring the I-V curve and quantity of ozone generation. The most effective condition of duty ratio and frequency to generate the non-thermal plasma was identified by experiments with manufactured non-thermal plasma generator.

The effects of primary gas physical properties on the performance of annular injection type supersonic ejector (주유동 기체의 물리적 특성이 환형 분사 초음속 이젝터의 성능에 미치는 영향)

  • Jin, Jung-Kun;Kim, Se-Hoon;Park, Geun-Hong;Kwon, Se-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.12
    • /
    • pp.68-75
    • /
    • 2005
  • The effects of the physical properties of primary flow on the performance of a supersonic ejector were investigated. Axisymmetric annular injection type supersonic ejector was used for the study of the effects of molecular weight and the specific heat at constant pressure on the ejection performance. Test gases include; air, $CO_{2}$, Ar, $C_{3}H_{8}$, and $CCl_{2}F_{2}$ for different values of gas properties. As the molecular weight and CP of the primary gas increase, the secondary flow pressure increases at the same primary stagnation pressure and this behavior results from the combined effects of molar specific heat or specific heat ratio.

Self-Sustained Tone Simulations using the Finite Difference Lattice Boltzmann Method with Flexible Specific Heat Ratio (조정 가능한 비열비를 갖는 FDLBM에 의한 자려발생 음의 시뮬레이션)

  • Oh, S.K.;Ahn, S.W.;Kim, J.W.;Kang, H.K.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.82-91
    • /
    • 2007
  • 기존의 2차원 FDLB 모델(D2Q21)에서 비열비 ${\gamma}$는 공간의 차원수(D)에 의존한다. 즉, 2차원 공간의 계산에서는 ${\gamma}=(D+2)/D=2.0$밖에 취할 수 없으며, 공기와 같은 실체기체를 전산모사 하기에는 여러 어려움이 있다. 이러한 이유 때문에 문헌[1]의 LBM에서 제안된 조정 가능한 비열비 모델을 2차원 FDLB모델에 적용하여 자려발생 에지톤(edgetone)의 수치계산이 수행되었다. wedge의 선단각도가 ${\alpha}=23^{\circ}$(Case I) 및 $20^{\circ}$(Case II)를 갖는 2가지 모델이 설정되었으며, 노즐출구에서 wedge선단까지의 거리 w/d는 $3d{\sim}12d$사이에서 주어졌다. edgetone은 노즐로부터 나온 분류와 edge의 상호작용으로 이난 음압(sound pressure)의 차에 의해서 소음이 발생하며, 이 음압은 다시 상류의 분류에 영향을 미쳐 분류의 변동을 가져온다. w/d가 ??9d이하인 경우, 피드백(feedback) 메커니즘에 기인한 주기적인 운동이 발생하지만, w/d가 큰 ??9d이상인 경우에는 분류의 불안정성 때문에 규칙적인 분류의 운동은 보이질 않으며, 이는 기존의 연구결과들과 잘 일치함을 보였다. 본 연구에서 적용된 모델을 이용하여 공기와 같은 2원자 기체의 비열비 ??${\gamma}=1.4$를 갖는 유체에 있어서 공력 소음의 수치예측이 가능하다는 것을 확인하였다.

  • PDF

Effect of Cementitious Composite on the Thermal and Mechanical Properties of Fiber-Reinforced Mortars for Thermal Energy Storage (열에너지 저장을 위한 시멘트 복합재료의 섬유보강 모르타르의 열역학 특성에 관한 영향)

  • Yang, In-Hwan;Kim, Kyoung-Chul;Choi, Young-Cheol
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.4
    • /
    • pp.395-405
    • /
    • 2016
  • The thermal and mechanical properties of fiber-reinforced mortars for thermal energy storage were investigated in this paper. The effect of the combination of different cementitious composite on the thermal and mechanical characteristics of fiber-reinforced mortars was investigated. Experiments were performed to measure mechanical properties including compressive strength before and after thermal cycling and split tensile strength, and to measure thermal properties including thermal conductivity and specific heat. The results showed that the residual compressive strength of mixtures with OPC and graphite was greatest among the mixtures. Thermal conductivity of mixtures with alumina cement was greater than that of mixtures with OPC, indicating favor of alumina cement for charging and discharging in thermal energy storage system. The addition of zirconium into alumina cement increased specific heat of mixtures. Test results of this study could be used to provide information of material properties for thermal energy storage concrete.

Influence of Post Heat Treatment on Corrosion Resistance of Al-Mg coating Films (Al-Mg 코팅막의 내식특성에 대한 열처리의 영향)

  • Gang, Jae-Uk;Park, Jun-Mu;Gang, Jun;Jeong, Jae-In;Yang, Ji-Hun;Lee, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.308-308
    • /
    • 2014
  • 본 연구에서 PVD법중 하나인 스퍼터링(sputtering)법에 의해 제작된 Al-Mg 코팅막은 SEM, GDS, XRD를 통해 표면 및 단면의 조성분포를 분석하였으며, 내식성을 평가하기 위하여 함량별, 열처리 조건별 Al-Mg 막을 각각 5% NaCl 염수분무 환경 및 3% NaCl 자연침지 환경에 노출시켰다. 막의 내식 특성에 영향을 미치는 열처리의 영향을 알아보기 위하여 열처리-비열처리간 재료 특성 및 내식성평가 결과의 연관성을 비교-분석하였다. 열처리 결과 Al-Mg계 금속간 화합물 $Al_3Mg_2$$Al_{12}Mg_{17}$이 관찰되었으며 내식성 평가 결과, 열처리 Al-Mg 막은 비열처리 Al-Mg 막과 비교하여 양호한 내식성을 나타냈었다. 열처리를 통해 마그네슘(Mg) 성분이 대부분 금속간 화합물상으로 존재함에 따라 균일하게 분포하여 치밀한 부식생성물을 형성하게 되고, 이에 따라 Al-Mg 막 내식성에 기여한 것으로 사료된다.

  • PDF

The Effects of Pressure and Specific Heat on the Performance of Thermal Mass Flowmeter (열량형 질량유량계에 대한 압력과 비열 영향)

  • Choi, Y. M,;Park, K. A.;Choi, H. M.;Lee, K. S.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.109-113
    • /
    • 1999
  • Thermal mass flow meter (TMF) is used measuring the small mass flow rate of gases. Generally, flow rate measuring accuracy of TMF is $\pm2{\%}$ of full scale. TMF is manufactured for specified working pressure and specified working gas by customer. If it were applied for different working pressure and gases, flow rate measurement accuracy decreased dramatically. In this study, a TMF tested with three different gases and pressure range of 0.2 MPa to 1.0 MPa. Effect of specific heat cause to increase flow measurement error as much as ratio of specific heat compare with reference gas. Pressure change cause to increase flowrate measurement deviation about $-0.2{\%}$ as the working pressure decreased 0.1 MPa.

  • PDF

A Study on Physicochemical Characteristics of Hydrogen Gas Explosion (수소가스 폭발의 물리화학적 특성 연구)

  • Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.1
    • /
    • pp.8-14
    • /
    • 2012
  • Hydrogen is considered to be the most important future energy carrier in many applications reducing significantly greenhouse gas emissions, but the explosion safety issues associated with hydrogen applications need to be investigated and fully understood to be applicable as the carrier. The risk associated with a explosion depends on an understanding of the impacts of the explosion, particularly the pressure-time history during the explosion. This work provides the effects of explosion parameters, such as specific heat ratio of burned and unburned gas, equilibrium maximum explosion pressure, and burning velocity, on the pressure-time history with flame growth model. The pressure-time history is dominantly depending on the burning velocity and equilibrium maximum explosion pressure of hydrogen-air mixture. The pressure rise rate increase with the burning velocity and equilibrium maximum explosion pressure. The specific heat ratio of unburned gas has more effect on the final explosion pressure increase rate than initial explosion pressure increase rate. However, the specific heat ratio of burned gas has more influence on initial explosion pressure increase rate. The flame speeds are obtained by fitting the experimental data sets. The flame speeds for hydrogen in air based on our experimental data is very low, making a transition from deflagration to detonation in a confined space unlikely under these conditions.

Adiabatic property of plywood wall panel (합판 벽체의 단열성능)

  • 박준철;홍순일
    • Journal of Korea Foresty Energy
    • /
    • v.21 no.2
    • /
    • pp.62-68
    • /
    • 2002
  • Adiabatic property of plywood wall panel was examined to evaluate their thermal conductivities. The amount of heat loss was investigated through overall heat transmission experiment. Styroform and grass wool showed less heat loss. However, yellowsoil board and laminated lumber showed high volume specific heat capacity. When the changes of indoor and outdoor temperature were checked in model house, wall manufactured with styroform and grass wool was affected easily by the changes of outdoor temperature. Yellowsoil, the mixed board of yellowsoil and sawdust, and laminated lumber, which have high volume specific heat capacity, were not affected much. The rates of overall heat transmission were much better in styroform and grasswool, but the adiabatic properties were much higher in yellowsoil board and the mixed board of yellowsoil and sawdust. The results showed that the insulating material can be developed using yellowsoil and wood, which are nature friendly materials.

  • PDF

Study on the Specific Heat of Rough Rice and Barley (미맥(米麥)의 비열(比熱)에 관한 연구(硏究))

  • Kim, Man Soo;Chang, Kyu Seop
    • Korean Journal of Agricultural Science
    • /
    • v.7 no.2
    • /
    • pp.145-155
    • /
    • 1980
  • An engineering design of the machines and equipment for processing grain as well as an understanding of processing itself need the knowledge of thermal properties of grain. Thermal properties of grain are thermal conductivity, thermal diffusivity and specific heat. Knowledge of any two and the bulk density of grain enables the third to be calculated. Several workers have investigated these properties, with special emphasis on thermal conductivity and diffusivity. However, some information is available on the specific heat of rough rice and barley but it is available only for a foreign variety of grain and for as a function of moisture content only. The objectives of this study were to develop a model for the specific heat of rough rice and barley which were a staple products in Korea as a function of initial temperature, moisture content and porosity of grain with cooling curve method, and to analyze the effect of these factors on the specific heat of rough rice and barley. The results of this study are summarized as follows; 1. The specific heat was $1.8209-2.7041kJ/kg\;^{\circ}K$ for Naked barley, 1.8862-2.5625 k.l/kg K for Covered barley, $1.5167-2.3779kJ/kg\;^{\circ}K$ for Japonica rice and $1.5260-2.3981kJ/kg\;^{\circ}K$ for Indica rice. 2. The model for the specific heat of rough rice and barley as a function of initial temperature, moisture content and porosity of grain was developed. 3. Specific heat of rough rice was decreased with initial temperature, but specific heat of barley was increased with initial temperature. 4. On the whole specific heat of sample grain was increased with moisture content of grain. 5. Specific heat of the grain was found to decrease with porosity except Indica rice.

  • PDF

A Study on the Method of Evaluating Optical-system Performance and an Athermal Structure through Thermal Analysis of the Korsch Telescope (Korsch 망원경의 열분석을 통한 광학계 성능 평가 방법 및 비열화 구조 연구)

  • Kim, Kyu-Ho;Park, Seong-Woo;Park, Seung-Han;Lee, Kyoung-Mook;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.6
    • /
    • pp.266-275
    • /
    • 2021
  • In this paper, a method for evaluating optical-system performance and an athermal structure through thermal analysis of the Korsch telescope was studied. In the case of an optical system having a complex asymmetrical structure, there is a limit to implementing the satellite structure by applying the coefficient of thermal expansion (CTE) in the optical-design software, so it is difficult to evaluate the performance of the optical system against temperature changes. To solve this problem, using mechanical design software all length changes were implemented in all structures that affect the optical system according to temperature, and the value of the change in distance between optical components due to temperature change was organized. Also, the values of changes in shape and thickness of the optical components against temperature changes are organized in the optical-design software. All changes derived from both software packages were applied in the optical software to evaluate the performance of the optical system. As a result, it was found that the MTF for a spatial resolution of 71.4 cycles/mm was maintained at more than 25% in the range from 9 ℃ to 33 ℃. In addition, the performance of the optical system applying the improved structure was evaluated, by finding the structure that had the most influence on the optical system's performance change, and deriving an athermal structure to reduce the effect. As a result, it was found that the MTF for a resolution of 71.4 cycles/mm was maintained at over 67% in the range from 9 ℃ to 33 ℃.