• Title/Summary/Keyword: 비열플라즈마

Search Result 42, Processing Time 0.027 seconds

Effect of Non-thermal plasma Reactor construction by $CF_4$ decomposition ($CF_4$ 분해에 미치는 비열플라즈마 반응기 구조의 영향)

  • Kim, Sun-Ho;Park, Jae-Yun;Ha, Hyun-Jin;Hwang, Bo-Guk;Kim, Kwang-Soo;Rim, Geun-Hie
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.912-916
    • /
    • 2002
  • In this paper, the $CF_4$ decomposition rate and by-product were investigated for a simulated two plasma reactors which are metal particle reactor and spiral wire reactor as function of mixed gases. The $CF_4$ decomposition rate by plasma reactor with metal particle electrode had a gain of 20~25[%] over that by plasma reactor with spiral wire electrode. The $CF_4$ decomposition efficiency increases with increasing applied voltage up to the critical voltage for spark formation. The $CF_4$ decomposition efficiency of metal particle reactor was about 80[%] at AC 24[kV]. The $CF_4$ decomposition rate used $Ar-N_2$ as base gas was the highest among three base gases of $N_2$, $Ar-N_2$, air. The by-products of the $N_2$, $Ar-N_2$ base as were similar, but in case of air base they were different.

  • PDF

NO Oxidation using Non-Thermal Plasma and NOx removal by NaOH-Water Solution Shower (비열플라즈마에 의한 NO의 산화와 NaOH 샤워해 의한 NOx의 제거특성)

  • Park, Jae-Yoon;Koh, Yong-Sul;Kim, Ick-Kewn;Park, Sang-Hyun;Koh, Hee-Seok;Lee, Duck-Chool
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.947-949
    • /
    • 1998
  • In this paper, the NO was oxidized $NO_2$ by using the non-thermal plasma and NOx removal characteristics were measured by showering NaOH water-solution to $NO_2$. The NO oxidation increased in the order of DC, AC, and Pulse. NOx oxidation for two stage with applied voltage was better than that for one stage with applied voltage. NO oxidation didn't depend on applied voltage. While NO oxidation was going on, NOx removal efficiency was 20-25%, however, significantly depended on the injection method of air and $H_2O$ + air. When NaOH water-solution density of 20% was showered to flue gases, NOx removal efficiency increased to 64%.

  • PDF

Removal Characteristics of Soot and NO by Nonthermal Plasma and Radical in a Diesel Engine (비열플라즈마와 라디칼을 이용한 디젤엔진의 매연 및 NO 제거 특성)

  • Jang, Yeong-Jun;Choe, Seung-Hwan;Kim, Gyu-Bo;Jeon, Chung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.4
    • /
    • pp.547-554
    • /
    • 2002
  • We are facing the serious environmental pollution difficulties such as acid rain, green house effects, etc. The gaseous matter NOx, SOx, VOCs which are regarded as main factors for these current pollutions are mainly emitted from power plants and vehicles. Therefore several leading countries are regulating the emissions strictly, especially the exhaust emissions from a Diesel engine without an aftertreatment device. The objective of this study is to find out soot and NO removal characteristics focused on the emissions of a Diesel engine by using nonthermal plasma for each engine speeds and loads. Electrostatic precipitator(wire-to-plate type reactor) is used for soot removal. Radicals generated from outer air and put into a mixing chamber in the end of exhaust line are used for NO removal. Concentration of exhaust emissions is analyzed from the gas analyzer(KaneMay) and FTIR to estimate by-products.

A study on the hydrogen generation's characteristics via non-thermal plasma and carrier gas (비열플라즈마에 의한 수소발생에 미치는 캐리어가스의 영향)

  • Kim, Jong-Seog;Park, Jae-Yoon;Jung, Jang-Gun;Kim, Tae-Yong;Koh, Hee-Seog;Lee, Hyun-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.215-219
    • /
    • 2004
  • This paper is investigated about the effect of carrier gas and humidity for generating hydrogen gas. In the experimental result of generating hydrogen gas by non-thermal plasma reactor, the rate of generating hydrogen gas is different with what kind of carrier gas is. We used two types of carrier gas, such as $N_2$ and He. $N_2$ as carrier gas is more efficient to generate hydrogen gas than He because $N_2$ is reacted with $O_2$, which is made from water dissociation. In comparison with no humidity and humidity 45[%], the generation of hydrogen gas is decreased with increasing the humidity. That is the result that the energy for water dissociation is reduced on water surface because a part of plasma energy is absorbed at the small particle produced from humidifier.

  • PDF

A Study for improving Decomposition Efficiency of Trichloroethylene using Atmospheric Plasma Reactor and Ozone Decomposing Catalyst (대기압플라즈마 및 오존 분해촉매를 이용한 트리클로로에틸렌의 분해효율 증진 연구)

  • Han, Sang-Bo;Park, Jae-Youn;Park, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.142-149
    • /
    • 2008
  • This paper proposes an effective decomposition method of trichloroethylene using pellet packed-bed non-thermal plasma reactor and catalyst. For that, two types of reactors filled with manganese dioxide and alumina pellets are designed. When $MnO_2$ packed reactor is used, TCE decomposition rate is high due to the generation of oxygen atom radicals at the surface of catalyst during ozone decomposition. In addition, When $Al_2O_3$ packed reactor is used, TCE is oxidized into DCAC and it did not decomposed into small molecules such as COx and $Cl_2$. However, the plasma processed gas using $Al_2O_3$ packed reactor is passed through the $MnO_2$ catalyst reactor, which is placed at the downstream of plasma reactor, the decomposition rate increased as well due to oxygen atom radicals through ozone decomposition. Therefore, the adequate use of $MnO_2$ catalyst in the plasma process is very promising way to increase the decomposition efficiency.

Simultaneous Removal Characteristics of NOx, SOx from Combustion Gases using Pulse Corona induced Plasma Chemical Processing (PPCP에 의한 연소가스 중 NOx, SOx 동시제거 특성)

  • Park, Jae-Yoon;Koh, Yong-Sul;Jung, Jang-Gun;Kim, Jung-Dal
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.211-216
    • /
    • 2000
  • In this paper, experimental investigations were carried out to remove NOx, SOx simultaneously from a simulated combustion flue gas [$NO(0.02%)-SO_2(0.08%)-CO_2-Air-N_2$] by using a pulse corona induced plasma chemical processing. Discharge domain of wire-cylindrical plasma reactor was separated from a gas flow duct to avoid unstable discharge by aerosol particle deposited on discharge electrode and grounded electrode. The NOx, SOx removal was experimentally investigated by a reaction induced to ammonium nitrate, ammonium sulfate using a low price of aqueous NaOH solution and a small quantity of ammonia. Volume percentage of aqueous NaOH solution used was 20% and $N_2$ flow rate was $2.5{\ell}/min$ for bubbling aqueous NaOH solution. Ammonia gas(l4.82%) balanced by argon was diluted by air and was introduced to a main simulated flue gas duct through $NH_3$ injection system which was in downstream of reactor. The $NH_3$ molecular ratio(MR) was determined based on [$NH_3$] and [$NO+SO_2$]. MR is 1.5. The NOx removal rates increased in the order of DC, AC and pulse, but SOx removal rates was not significantly effected by source of electricity. The NOx removal rate slightly decreased with increasing initial concentration. but SOx removal rate was not significantly affected by initial concentration. The NOx, SOx removal rates decreased with increasing gas flow rate.

  • PDF

Applying Rosen-type PZT plasma generation device for medical applications (로젠형 압전변압기를 적용한 의료융합 플라즈마기기)

  • Lee, Kang-yeon;Jung, Byung-Geun;Park, Jeong-sook;Park, Ju-Hoon;Jeong, Byeong-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.1
    • /
    • pp.243-250
    • /
    • 2021
  • In the medical field, applications of plasma are applied sterilize instruments mainly but with the advent of bio-plasma technology, the scope of application is expanding. Recently, In addition, high-density miniaturization with handheld is required for sophisticated procedures when irradiated directly or treated with non-standard conditions. Rosen-type PZT is a device with a structure that generates high voltage plasma by achieving voltage transformation through electro-mechanical coupling using piezoelectric effect.and is used in portable plasma generating devices as an advantage to increase energy density relatively. In this paper, Rosen-type PZT was modeled using equivalent circuits and was carried out and a plasma generating device for medical application was designed and prototype tested. Prototype plasma generating device generates an output voltage of 5.8 kV with 12V input power and is designed to operate at high voltage by applying the half-bridge topology power converter. The results of the study confirmed the availability of various medical devices, such as plasma jets or direct exposure equipment.

Experiment on the Sterilization Performance of Airborne Bacteria in Indoor Spaces using the Variation of Ozone Concentration Generated According to the Discharge Time of a Plasma Module with a Dielectric Barrier Discharge Technology (유전체 장벽방전 플라즈마 방전시간에 따른 오존 발생 농도변화의 값을 통한 실내 공간 내 부유세균 살균성능에 대한 실험)

  • Su Yeon Lee;Chang Soo Kim;Gyu Ri Kim;Jong Eon Im
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.2
    • /
    • pp.344-351
    • /
    • 2023
  • Purpose: This study aimed to evaluate the effectiveness of a dielectric barrier discharge (DBD) plasma module for sterilizing airborne bacteria in indoor spaces and measure the concentration of ozone generated during plasma discharge. Method: The DBD plasma module was installed in a 76m3 space, and air samples were collected under various discharge times to compare the reduction of airborne bacteria. Result: The results showed a significant decrease in airborne bacteria, ranging from 92.057% to 99.999%, with an average ozone concentration of 0.04 ppm, below the reference value. Conclusion: The study suggests that plasma discharge can be used as a means of preventing the spread of airborne bacteria and viruses, while ensuring safety for human exposure.

Study on the Indoor Air Purification Technology by Using Nonthermal Plasma (비열 방전 플라즈마에 의한 실내 공기 청정기술 연구)

  • Jung, Jae-Seung;Lee, Heon-Gyeong;Kim, Jin-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.2
    • /
    • pp.31-36
    • /
    • 2016
  • For the purpose of indoor air purification, air conditioner or purifier is generally used, but the long operating time induced the contamination by cumulation of bacteria in the air filter. The ozone sterilization method can be one of the effective sterilization method for this case. Ozone has not leave a secondary residual contaminants, as well as a strong sterilization power. In this study, nonthermal plasma technology is investigated as an ozone generator for the air filter sterilization. Additionally, nonthermal plasma technology is possible to obtain the generation of negative ions and electrostatic force by simply adjusting the applied voltage.

NO Removal Characteristics in $N_2$ for a Dielectric Barrier Discharge Reactor with the Variation of a Discharge Gap (유전체 장벽 방전 반응기에서 방전 간극의 변화에 따른 질소 분위기하의 NO 제거 특성)

  • 차민석;이재옥;신완호;송영훈;김석준
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.407-408
    • /
    • 2000
  • 유전체 장벽 방전 반응기 (Dielectric Barrier Discharge (DBD) Reactor)를 이용한 비열 플라즈마(Non-thermal plasma) 공정에서 NO 제거 특성을 실험적으로 연구하였다. 질소 분위기에서 전자에 의한 NO 의 제거는 $N_2$ + e $\longrightarrow$ N + N + e 반응에 의한 질소의 전자충돌해리 (electron-impact dissociation)와 이 반응에 의하여 생성된 질소원자에 의한 NO 의 환원반응 N + NO $\longrightarrow$ $N_2$ + O 으로 설명될 수 있으며, 이로 인하여 $O_2$$H_2O$ 의 첨가에 따른 부산물(O, $O_3$, OH 등)에 의한 산화반응이 주로 일어나는 경우 (XO + NO $\longrightarrow$ X + NO$_2$) 와는 달리 NO 제거에 소모된 에너지를 평가하기에 용이한 장점이 있다(Penetrante et al., 1995). (중략)

  • PDF