• Title/Summary/Keyword: 비선형도

Search Result 12,666, Processing Time 0.045 seconds

Static and Dynamic Analysis for Railway Tunnel according to Filling Materials for overbroken tunnel bottom (철도터널 하부 여굴처리 방법에 대한 정적 및 동적 안정성 검토)

  • Seo, Jae-Won;Cho, Kook-Hwan
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.5
    • /
    • pp.668-682
    • /
    • 2017
  • Alignments of railways recently constructed in Korea have been straightened due to the advent of high-speed rail, which means increasing the numbers of tunnels and bridges. Overbreak during tunnel construction may be unavoidable, and is very influential on overall stability. Over-excavation in tunneling is also one of the most important factors in construction costs. Overbreak problems around crown areas have decreased with improvements of excavation methods, but overbreak problems around bottom areas have not decreased because those areas are not very influential on tunnel stability compared with crown areas. The filling costs of 10 cm thickness of overbreak at the bottom of a tunnel are covered under construction costs by Korea Railway Authority regulations, but filling costs for more than the covered thickness are considered losses of construction cost. The filling material for overbreak bottoms of tunnels should be concrete, but concrete and mixed granular materials with fractured rock are also used for some sites. Tunnels in which granular materials with fractured rock are used may have a discontinuous section under the concrete slab track. The discontinuous section influences the propagation of waves generated from train operation. When the bottom of a tunnel is filled with only concrete material, the bottom of the tunnel can be considered as a continuous section, in which the waves generated from a train may propagate without reflection waves. However, a discontinuous section filled with mixed granular materials may reflect waves, which can cause resonance of vibration. The filled materials and vibration propagation characteristics are studied in this research. Tunnel bottom filling materials that have ratios of granular material to concrete of 5.0 %, 11.5 %, and 18.0 % are investigated. Samples were made and tested to determine their material properties. Static numerical analyses were performed using the FEM program under train operation load; test results were found to satisfy the stability requirements. However, dynamic analysis results show that some mixed ratios may generate resonance vibration from train operation at certain speeds.

Study on the Impact of Roadside Forests on Particulate Matter between Road and Public Openspace in front of Building Site - Case of Openspace of Busan City hall in Korea - (도심 도로변 가로녹지가 주변 오픈스페이스의 미세먼지농도에 미치는 영향 연구 - 부산시청 광장을 대상으로 -)

  • Hong, Suk-Hwan;Kang, Rae-Yeol;An, Mi-Yeon;Kim, Ji-Suk;Jung, Eun-Sang
    • Korean Journal of Environment and Ecology
    • /
    • v.32 no.3
    • /
    • pp.323-331
    • /
    • 2018
  • This study was conducted to examine the effects of constructing streetside urban forests on particulate matter (PM) content in pedestrian paths and open spaces created between the main streets and buildings in a high-rise, high-density urban area. The study site is a 70m-wide open space between Busan City Hall and Jungang-street in Busan, Korea. The results showed that the density of PM differences between the open space and the adjacent main street were small in regions without linear trees and shrub rows during both the weekdays and weekend. On the other hand, the areas with linear trees and shrub rows were found to have significantly higher concentrations of PM compared to the roadway. In particular, sections with linear trees and shrub rows had higher PM levels both on roads and in adjacent open space, indicating that the composition of linear trees and shrub rows increased the concentration of PM in the off-street open space in areas with wide space between the roadway and building. The impact was more significant in the open space than the roadway. This phenomenon can be explained by the fact that PM generated by vehicles flows through the roadside shrubs by rapid wind flow but does not disperse widely in the pedestrian paths where the wind flow was reduced. In this study, we found that the roadside tree and shrub walls slowed the flow of wind, causing vehicle-emitted PM to accumulate if a wide open space was created between the road and building, resulting in higher concentration of PM in the open space. We confirmed that the distance between the road and building was a critical factor for constructing linear trees and shrub rows to reduce PM generated by vehicle traffic.

The Effected Factors on Customer Satisfaction of Medical Service and Willingness to Revisit among Selected Hospital Users in a Local City (일 지방 도시의 종합병원 이용자들의 의료서비스 만족도와 재이용 의사에 미치는 요인)

  • Seo, Seung-Hee;Park, Jong-Young;Han, Sung-Hyun
    • Journal of agricultural medicine and community health
    • /
    • v.30 no.1
    • /
    • pp.89-100
    • /
    • 2005
  • Objectives: This study was to find the effected factors on customer satisfaction for medical service and the willingness to revisit among hospital users Methods: The data was collected by a questionnaire survey from February 1 to April 30, 2004, and 600 samples have been analysed among users of university hospital, private hospital and public hospital in a local city. Results and Conclusions: The satisfaction total score to use hospital was 113.54 points(out of 175 point), these scores were constituted 39.10 points(out of 55 point) on satisfaction score for kindness of hospital employee, 36.28 points(out of 60 point) for equipment utilization and service formality, 18.59 points(out of 30 point) for environmental status and 19.57 points(out of 30 points) for reliability in medical examination and treatment service. The factors effected on satisfaction total score to use hospital were type of visiting hospital, age of customer, convenience to visit the hospital, experience of using other hospitals(R2=0.171). The effected factors of willingness to revisit scores were such as satisfaction score in medical examination and treatment service, satisfaction score of kindness hospital employee, experience of health examination and age of customer($R^2=0.370$). In conclusion, to raise the response's willingness to revisit. This must be reinforced by employee's kindness education and medical service quality.

  • PDF

Carbon Fiber as Material for Radiation Fixation on Device : A comparative study with acrylic (고정기구 재질로써 탄소 섬유와 아크릴의 방사선량 감쇄 영향 비교)

  • Chie, Eui-Kyu;Park, Jang-Pil;Huh, Soon-Nyung;Hong, Se-Mie;Park, Suk-Won;Kim, In-Ah;Wu, Hong-Gyun;Kim, Jae-Sung;Kang, Wee-Saing;Kim, Il-Han;Ha, Sung-Whan;Park, Charn-Il
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • Radiation absorption parameters of carbon fiber panel were measured in comparison to acrylic panel. $30{\times}30cm$ sized 2mm thick carbon fiber panel and identical sized 6mm thick acrylic panel were placed in tray holder position and 0cm, 5cm, 10cm from surface of phantom. Radiation field size was $10{\times}10cm$. 50MU of 4MV photon was irradiated to the phantom with dose rate of 300MU/min. Source-to-phantom distance was 120cm. Radiation dose was measured with 0.6cc Farmer-type ionization chamber with 1cm build-up. Measurement was repeated thrice and normalization was done to the dose of the open field. Radiation transmission rate of carbon fiber panel is approximately 1% lower than acrylic panel of equivalent thickness. However, considering the strength of the material, transmission rate is higher for carbon fiber panel. Although carbon fiber panel increases the radiation dose when attached to the surface for about 2%, it normalizes the radiation dose to 97-99% of irradiated dose which could have been lowered to as much as 5-7.5% with acrylic panel. As carbon fiber panel is stronger than acrylic panel, radiation fixation device could be made thinner and thus lighter and furthermore, with increased radiation transmission. This in turn makes carbon fiber more ideal material for radiation fixation device over conventionally used acrylic.

Analysis of Hydrological Impact Using Climate Change Scenarios and the CA-Markov Technique on Soyanggang-dam Watershed (CA-Markov 기법을 이용한 기후변화에 따른 소양강댐 유역의 수문분석)

  • Lim, Hyuk-Jin;Kwon, Hyung-Joong;Bae, Deg-Hyo;Kim, Seong-Joon
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.5 s.166
    • /
    • pp.453-466
    • /
    • 2006
  • The objective of this study was to analyze the changes in the hydrological environment in Soyanggang-dam watershed due to climate change results (in yews 2050 and 2100) which were simulated using CCCma CGCM2 based on SRES A2 and B2. The SRES A2 and B2 were used to estimate NDVI values for selected land use using the relation of NDVI-Temperature using linear regression of observed data (in years 1998$\sim$2002). Land use change based on SRES A2 and B2 was estimated every 5- and 10-year period using the CA-Markov technique based on the 1985, 1990, 1995 and 2000 land cover map classified by Landsat TM satellite images. As a result, the trend in land use change in each land class was reflected. When land use changes in years 2050 and 2100 were simulated using the CA-Markov method, the forest class area declined while the urban, bareground and grassland classes increased. When simulation was done further for future scenarios, the transition change converged and no increasing trend was reflected. The impact assessment of evapotranspiration was conducted by comparing the observed data with the computed results based on three cases supposition scenarios of meteorological data (temperature, global radiation and wind speed) using the FAO Penman-Monteith method. The results showed that the runoff was reduced by about 50% compared with the present hydrologic condition when each SRES and periods were compared. If there was no land use change, the runoff would decline further to about 3$\sim$5%.

Comparison of Experimental and Radiation Therapy Planning (RTP) Dose Distributions on Air Cavity (공동(air cavity)의 존재 시 실험적 선량분포와 치료계획상의 선량분포 비교)

  • Kim, Yon-Lae;Suh, Tae-Suk;Ko, Shin-Gwan;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.261-268
    • /
    • 2010
  • This study is compared that the dose distribution by experimentation and radiation therapy planning (RTP) when the air cavity region was treated high energy photon. The dose measurements were performed with a 6 MV photon beam of linear accelerator. The polystyrene and self made acyl phantom were similar to tissue density of the human body. A parallel plate chamber was connected to an electrometer. The measurement setup was SCD (Source Chamber Distance) 100 cm and the distance of surface from air cavity was 3 cm. Absorbed dose of interface were measured by area and height. The percent depth dose were measured presence and absence of air cavity, depth according to a ratio of field size and air cavity size. The dose distribution on planning was expressed to do the inhomogeneity correction. As the area of air cavity was increased, the absorbed dose were gradually reduced. It was slightly increased, when the height of air cavity was changed from 0 cm to 0.5 cm. After the point, dose was decreased. In case of presence of air cavity, dose after distal air cavity interface was more great than absence of air cavity. The rebuild up by field size and area of air cavity occurred for field size, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$ and $6{\times}6\;cm^2$, with fixed on area of air cavity, $5{\times}5\;cm^2$. But it didn't occur at $10{\times}10\;cm^2$ field size. On the contrary, the field size was fixed on $5{\times}5\;cm^2$, rebuild up occurred in area of air cavity, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$. but, it did not occur for air cavity, $2{\times}2\;cm^2$, $3{\times}3\;cm^2$. All of the radiation therapy planning were not occurred rebuild up. It was required to pay attention to treat tumor in air cavity because the dose distribution of planning was different from the dose distribution of patient.

The Utility of Measurement of Plasma N-terminal Pro-brain Natriuretic Peptide in Diagnosis of Pulmonary Hypertension (폐동맥고혈압 진단에 있어 N-terminal Pro-brain Natriuretic Peptide 측정의 유용성)

  • Hahn, Chang Hoon;Kang, Seok Min;Moon, Jin Wook;Cho, Jae Hee;Hwang, Sang Yon;Lee, Jung Min;Park, Moo Suk;Chung, Jae Ho;Kim, Young Sam;Kim, Se Kyu;Chang, Joon;Shim, Won Heum;Kim, Sung Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.1
    • /
    • pp.67-76
    • /
    • 2004
  • Background : Pulmonary hypertension is a poor prognostic factor in patients with chronic respiratory disease. However, diagnosing pulmonary hypertension is a difficult procedure which often requires an invasive test. Thus new alternative biochemical markers would be useful in clinical field and are in search. We sought to assess the role of plasma N-terminal pro-brain natriuretic peptide(NT-proBNP) in patients with pulmonary hypertension. Method : We measured plasma NT-proBNP level in twenty nine patients suspected for pulmonary hypertension. Pulmonary hypertension was defined as being right ventricular systolic pressure more than 35 mm Hg estimated by Doppler echocardiography. Plasma NT-proBNP level was measured by electrochemiluminescence sandwich immunoassay. Results : The log-transformed values for plasma NT-proBNP levels showed a linear correlation (correlation coefficiency: 0.783, p-value <0.001) with right ventricular systolic pressure. Plasma NT-proBNP levels closely correlated with right ventricular systolic pressure, right ventricular hypertrophy, interventricular septal flattening and right ventricular dilatation. Conclusion : Our results suggest that the measurement of plasma NT-proBNP level is an useful marker of the presence of pulmonary hypertension.

Comparative Analysis of Catechins and Antioxidant Capacity in Various Grades of Organic Green Teas Grown in Boseong, Korea (보성산 유기농 녹차의 품질에 따른 카테킨 함량과 항산화능 비교 분석)

  • Park, Kyung-Ryun;Lee, Sang-Gil;Nam, Tae-Gyu;Kim, Young-Jun;Kim, Young-Rok;Kim, Dae-Ok
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.1
    • /
    • pp.82-86
    • /
    • 2009
  • The objective of this study was to evaluate the effect of various solvents on extraction of bioactive phenolics and to analyze the antioxidant capacity and contents of individual catechins in various grades of green teas organically grown in Boseong, Korea. The organic green teas, based on their harvest seasons, were categorized into five grades such as Woo-Jeon, Se-Jak, Jung-Jak, Dae-Jak, and coarse tea. Solvents used to extract phenolics from these teas included water at $23^{\circ}C$ and $70^{\circ}C$ as well as 80% (v/v) aqueous methanol and ethanol. In general, aqueous organic solvents of methanol and ethanol led to higher extraction yields of phenolics than water at $23^{\circ}C$ and $70^{\circ}C$. Total phenolics and antioxidant capacity of the teas extracted with the aqueous organic solvents were approximately 1.5 to 3.2 and 1.8 to 3.8 times higher than those with water at $23^{\circ}C$ and $70^{\circ}C$, respectively. Coarse tea, the lowest grade of green tea, showed approximately 30-60% lower total phenolics and antioxidant capacity compared with the higher grade ones. Reversed-phase HPLC analysis was performed quantitatively to identify individual catechins, gallic acid, and caffeine in teas extracted with 80% (v/v) aqueous methanol. Based on their dry weights, the organic green teas contained about 1.7 to 2.9% of caffeine. Content (mg/g dry weight) of tea catechins decreased in the following order: Woo-Jeon (155.4) > Se-Jak (147.7) > Jung-Jak (143.2) > coarse tea (135.1) > Dae-Jak (130.5). (-)-Epigallocatechin gallate was the most abundant among the catechins analyzed. The highest grade of green tea, Woo-Jeon, had the highest amount of (-)-epigallocatechin gallate at 77.4 mg/g dry weight. Overall, the higher grade of organic green teas tended to have the higher level of antioxidant capacity and catechins.

Discounted Cost Model of Condition-Based Maintenance Regarding Cumulative Damage of Armor Units of Rubble-Mound Breakwaters as a Discrete-Time Stochastic Process (경사제 피복재의 누적피해를 이산시간 확률과정으로 고려한 조건기반 유지관리의 할인비용모형)

  • Lee, Cheol-Eung;Park, Dong-Heon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.29 no.2
    • /
    • pp.109-120
    • /
    • 2017
  • A discounted cost model for preventive maintenance of armor units of rubble-mound breakwaters is mathematically derived by combining the deterioration model based on a discrete-time stochastic process of shock occurrence with the cost model of renewal process together. The discounted cost model of condition-based maintenance proposed in this paper can take into account the nonlinearity of cumulative damage process as well as the discounting effect of cost. By comparing the present results with the previous other results, the verification is carried out satisfactorily. In addition, it is known from the sensitivity analysis on variables related to the model that the more often preventive maintenance should be implemented, the more crucial the level of importance of system is. However, the tendency is shown in reverse as the interest rate is increased. Meanwhile, the present model has been applied to the armor units of rubble-mound breakwaters. The parameters of damage intensity function have been estimated through the time-dependent prediction of the expected cumulative damage level obtained from the sample path method. In particular, it is confirmed that the shock occurrences can be considered to be a discrete-time stochastic process by investigating the effects of uncertainty of the shock occurrences on the expected cumulative damage level with homogeneous Poisson process and doubly stochastic Poisson process that are the continuous-time stochastic processes. It can be also seen that the stochastic process of cumulative damage would depend directly on the design conditions, thus the preventive maintenance would be varied due to those. Finally, the optimal periods and scale for the preventive maintenance of armor units of rubble-mound breakwaters can be quantitatively determined with the failure limits, the levels of importance of structure, and the interest rates.

A Study on the Geophysical Characteristics and Geological Structure of the Northeastern Part of the Ulleung Basin in the East Sea (동해 울릉분지 북동부지역의 지구물리학적 특성 및 지구조 연구)

  • Kim, Chang-Hwan;Park, Chan-Hong
    • Economic and Environmental Geology
    • /
    • v.43 no.6
    • /
    • pp.625-636
    • /
    • 2010
  • The geophysical characteristics and geological structure of the northeastern part of the Ulleung Basin were investigated from interpretation of geophysical data including gravity, magnetic, bathymetry data, and seismic data. Relative correction was applied to reduce errors between sets of gravity and magnetic data, obtained at different times and by different equipments. The northeastern margin of the Ulleung Basin is characterized by complicated morphology consisting of volcanic islands (Ulleungdo and Dokdo), the Dokdo seamounts, and a deep pathway (Korea Gap) with the maximum depth of -2500 m. Free-air anomalies generally reflect the topography effect. There are high anomalies over the volcanic islands and the Dokdo seamounts. Except local anomalous zones of volcanic edifices, the gradual increasing of the Bouguer anomalies from the Oki Bank toward the Ulleung Basin and the Korea Gap is related to higher mantle level and denser crust in the central of the Ulleung Basin. Complicated magnetic anomalies in the study area occur over volcanic islands and seamounts. The power spectrum analysis of the Bouguer anomalies indicates that the depth to the averaged Moho discontinuity is -16.1 km. The inversion of the Bouguer anomaly shows that the Moho depth under the Korea Gap is about -16~17 km and the Moho depths towards the Oki Bank and the northwestern part of Ulleung Island are gradually deeper. The inversion result suggests that the crust of the Ulleung Basin is thicker than normal oceanic crusts. The result of 20 gravity modeling is in good agreement with the results of the power spectrum analysis and the inversion of the Bouguer anomaly. Except the volcanic edifices, the main pattern of magnetization distribution shows lineation in NE-SW. The inversion results, the 2D gravity modeling, and the magnetization distribution support possible NE-SW spreading of the Ulleung Basin proposed by other papers.