• Title/Summary/Keyword: 비선형도

Search Result 12,686, Processing Time 0.054 seconds

Distributions of 137Cs and 90Sr in the Soil of Uljin, South Korea (울진토양에서의 137Cs 및 90Sr 분포)

  • Song, JiYeon;Kim, Wan;Maeng, Seongjin;Lee, Sang Hoon
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.1
    • /
    • pp.49-55
    • /
    • 2016
  • Background: For the purpose of baseline data collection and enhancement of environmental monitoring the distribution studies of $^{137}Cs$ and $^{90}Sr$ in the soil of Uljin province was performed and the relation between surface soil activities and soil properties (pH, TOC and median of the surface soil) was analyzed. Materials and Methods: For 14 spots within 10 km from the NPP surface soil samples were collected and soils for depth profile were sampled for 3 spots in April 2011. Using ${\gamma}$-ray spectrometry with HPGe detector, the concentrations of $^{137}Cs$ were determined and the concentrations of $^{90}Sr$ were measured by counting ${\beta}$-activity of $^{90}Y$ (in equilibrium with $^{90}Sr$) in a gas flow proportional counter. Results and Discussion: The concentration ranges of $^{137}Cs$ and $^{90}Sr$ were $<0.479-39.6Bq{\cdot}(kg-dry)^{-1}$ (avg. $7.51Bq{\cdot}(kg-dry)^{-1}$) and $0.209-1.85Bq{\cdot}(kg-dry)^{-1}$ (avg. $0.74Bq{\cdot}(kg-dry)^{-1}$) which were similar to the reported values from other regions in Korea. The activity ratio of $^{137}Cs$ to $^{90}Sr$ in surface soils was around 9.67, which is much bigger than the initial value of 1.75 for worldwide fallouts because of faster downward movement of $^{90}Sr$ after fallout than that of $^{137}Cs$. For depth profile studies soils were collected down to 40 cm depth for the locations of Deokgu, Hujeong and Maehwa. The $^{137}Cs$ concentration distribution of the first two showed maximum values at top soils and decreased rapidly in exponential manner, while $^{90}Sr$ showed two local maximum values for soils near top and about 30 cm depth. Through linear fittings between the $^{137}Cs$ and $^{90}Sr$ concentrations of surface soil and pH, TOC and median of the surface soil, the only probable relationship obtained was between $^{137}Cs$ and TOC (determination coefficient $R^2=0.6$). Conclusion: The concentration ranges of $^{137}Cs$ and $^{90}Sr$ in Uljin were similar to the reported values from other regions in Korea. The only probable relationship obtained between activities and soil properties was between $^{137}Cs$ and TOC.

Normal Predictive Values of Spirometry in Korean Population (한국인의 정상 폐활량 예측치)

  • Choi, Jung Keun;Paek, Domyung;Lee, Jeoung Oh
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.3
    • /
    • pp.230-242
    • /
    • 2005
  • Background : Spirometry should be compared with the normal predictive values obtained from the same population using the same procedures, because different ethnicity and different procedures are known to influence the spirometry results. This study was performed to obtain the normal predictive values of the Forced Vital Capacity(FVC), Forced Expiratory Volume in 1 Second($FEV_1$), Forced Expiratory Volume in 6 Seconds($FEV_6$), and $FEV_1/FVC$ for a representative Korean population. Methods : Based on the 2000 Population Census of the National Statistical Office of Korea, stratified random sampling was carried out to obtain representative samples of the Korean population. This study was performed as a part of the National Health and Nutrition Survey of Korea in 2001. The lung function was measured using the standardized methods and protocols recommended by the American Thoracic Society. Among those 4,816 subjects who had performed spirometry performed, there was a total of 1,212 nonsmokers (206 males and 1,006 females) with no significant history of respiratory diseases and symptoms, with clear chest X-rays, and with no significant exposure to respiratory hazards subjects. Their residence and age distribution was representative of the whole nation. Mixed effect models were examined based on the Akaike's information criteria in statistical analysis, and those variables common to both genders were analyzed by regression analysis to obtain the final equations. Results : The variables affecting the normal predicted values of the FVC and $FEV_6$ for males and females were $age^2$, height, and weight. The variables affecting the normal predicted values of the $FEV_1$ for males and females were $age^2$, and height. The variables affecting the normal predicted values of the $FEV_1/FVC$ for male and female were age and height. Conclusion : The predicted values of the FVC and $FEV_1$ was higher in this study than in other Korean or foreign studies, even though the difference was < 10%. When compared with those predicted values for Caucasian populations, the study results were actually comparable or higher, which might be due to the stricter criteria of the normal population and the systemic quality controls applied to the whole study procedures together with the rapid physical growth of the younger generations in Korea.

Dosimetric Characteristics of Edge $Detector^{TM}$ in Small Beam Dosimetry (소조사면 선량 계측을 위한 엣지검출기의 특성 분석)

  • Chang, Kyung-Hwan;Lee, Bo-Ram;Kim, You-Hyun;Choi, Kyoung-Sik;Lee, Jung-Seok;Park, Byung-Moon;Bae, Yong-Ki;Hong, Se-Mie;Lee, Jeong-Woo
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.191-198
    • /
    • 2009
  • In this study, we evaluated an edge detector for small-beam dosimetry. We measured the dose linearity, dose rate dependence, output factor, beam profiles, and percentage depth dose using an edge detector (Model 1118 Edge) for 6-MV photon beams at different field sizes and depths. The obtained values were compared with those obtained using a standard volume ionization chamber (CC13) and photon diode detector (PFD). The dose linearity results for the three detectors showed good agreement within 1%. The edge detector had the best linearity of ${\pm}0.08%$. The edge detector and PFD showed little dose rate dependency throughout the range of 100~600 MU/min, while CC13 showed a significant discrepancy of approximately -5% at 100 MU/min. The output factors of the three detectors showed good agreement within 1% for the tested field sizes. However, the output factor of CC13 compared to the other two detectors had a maximum difference of 21% for small field sizes (${\sim}4{\times}4\;cm^2$). When analyzing the 20~80% penumbra, the penumbra measured using CC13 was approximately two times wider than that using the edge detector for all field sizes. The width measured using PFD was approximately 30% wider for all field sizes. Compared to the edge detector, the 10~90% penumbras measured using the CC13 and PFD were approximately 55% and 19% wider, respectively. The full width at half maximum (FWHM) of the edge detector was close to the real field size, while the other two detectors measured values that were 8~10% greater for all field sizes. Percentage depth doses measured by the three detectors corresponded to each other for small beams. Based on the results, we consider the edge detector as an appropriate small-beam detector, while CC13 and PFD can lead to some errors when used for small beam fields under $4{\times}4\;cm^2$.

  • PDF

Structural Characteristics and Anti-inflammatory Activities of Chemically Sulfated-hyaluronic Acid from Streptococcus dysgalactiae (Streptococcus dysgalactiae로부터 분리된 히알루론산과 황화된 유도체의 구조와 항염증 활성)

  • Hong, Chang-Il;Jung, Eui-Gil;Han, Kook-Il;Kim, Yong Hyun;Lee, Sung Hee;Lee, Hong Sub;Han, Man-Deuk
    • Journal of Life Science
    • /
    • v.26 no.5
    • /
    • pp.545-554
    • /
    • 2016
  • Hyaluronic acid (HA) is an important macromolecule in medical and pharmaceutical fields. HA is a natural and linear polymer composed of repeating disaccharide units of β-1, 3-N-acetyl glucosamine and β-1, 4-glucuronic acid. This work aimed to confirm the structural characteristics and anti-inflammatory activities of HA and its chemically sulfated-HA. HA was produced from a fed-batch fermentation process using Streptococcus dysgalactiae in a 5 l bioreactor. HA was isolated water-soluble form (HA-WS) and water-insoluble form (HA-WI) from culture medium, and was obtained chemically sulfated-derivative (S-HA) that resulted in a 90% yield from HA-WI. The structural features of the sulfated- HA (S-HA) were investigated by FT-IR and 1H-NMR spectroscopy. The FT-IR and NMR patterns revealed the similarity in both the FTIR spectrum as well as NMR spectrum of both reference standard and purified HA from S. dysgalactiae. The anti-inflammatory activities of HA and S-HA were examined on LPS-induced RAW 264.7 cells. S-HA was significantly inhibited production of pro-inflammatory mediators such as nitric oxide (NO) and PGE2 and the gene levels of iNOS and COX-2, which are responsible for the production of NO and PGE2, respectively. Furthermore, S-HA also suppressed the overproduction of pro-inflammatory cytokine TNF-α (<80 pg/ml) and IL-6 (<100 pg/ml) compared to that of HA-WI. The present study clearly demonstrates that HA-S exhibits anti-inflammatory activities in RAW 264.7 macrophage cells.

Environmental and Physiological Factors on Milk Yields and Compositions of Holstein Cows in Korea (Holstein 젖소에 있어서 유량 및 유성분에 미치는 환경 및 생리적 요인)

  • Han, K.J.;Ahn, J.H.;Lee, D.H.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.3
    • /
    • pp.335-346
    • /
    • 2004
  • Factors associated with milk urea nitrogen on milk yield and milk composition were investigated in this study regarding feeding management and Physiological status of lactating cows. The data for 3 years between 1999 and 2002 for this study were collected from 129,645 cows by Korean Agricultural Cooperatives Federation. The objectives of this study were to describe the relationships between milk urea concentrations and seasonal factors, cow factors and production of milk, milk fat, protein and somatic cell score(SCS). Milk urea was highest in summer and it also showed a nonlinear association with milk yield. Milk yield was higher at milk urea concentrations of 21 ${\sim}$ 24mg/dl, however it decreased at higher level of milk urea concentrations than 24mg/dl. Milk urea was higher with increased parities of cows and in particular, at 3 to 4 parities. There was a negative association between milk urea and SCS in milk. SCS in milk was lowest at milk urea concentrations of 2l${\sim}$24mg/dl. Milk fat and milk protein were greatly affected by days in milk(DIM), year of birth, season and milk urea concentrations, respectively. While milk urea increased in summer, milk fat and protein were decreased. Milk protein decreased according to longer days in milk. With regard to the influences of parity, milk protein in overall was negatively correlated to milk urea in all lactations, however the extent of decrease of milk protein at high concentrations of milk urea was bigger at third lactation. The balanced supply of energy and protein to the animals might have greatly affected the urea concentrations and protein content of milk.

Development and Evaluation of Traffic Conflict Criteria at an intersection (교차로 교통상충기준 개발 및 평가에 관한 연구)

  • 하태준;박형규;박제진;박찬모
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.2
    • /
    • pp.105-115
    • /
    • 2002
  • For many rears, traffic accident statistics are the most direct measure of safety for a signalized intersection. However it takes more than 2 or 3 yearn to collect certain accident data for adequate sample sizes. And the accident data itself is unreliable because of the difference between accident data recorded and accident that is actually occurred. Therefore, it is rather difficult to evaluate safety for a intersection by using accident data. For these reasons, traffic conflict technique(TCT) was developed as a buick and accurate counter-measure of safety for a intersection. However, the collected conflict data is not always reliable because there is absence of clear criteria for conflict. This study developed objective and accurate conflict criteria, which is shown below based on traffic engineering theory. Frist, the rear-end conflict is regarded, when the following vehicle takes evasive maneuver against the first vehicle within a certain distance, according to car-following theory. Second, lane-change conflict is regarded when the following vehicle takes evasive maneuver against first vehicle which is changing its lane within the minimum stopping distance of the following vehicle. Third, cross and opposing-left turn conflicts are regarded when the vehicle which receives green sign takes evasive maneuver against the vehicle which lost its right-of-way crossing a intersection. As a result of correlation analysis between conflict and accident, it is verified that the suggested conflict criteria in this study ave applicable. And it is proven that estimating safety evaluation for a intersection with conflict data is possible, according to the regression analysis preformed between accident and conflict, EPDO accident and conflict. Adopting the conflict criteria suggested in this study would be both quick and accurate method for diagnosing safety and operational deficiencies and for evaluation improvements at intersections. Further research is required to refine the suggested conflict criteria to extend its application. In addition, it is necessary to develope other types of conflict criteria, not included in this study, in later study.

A Study on Visitor Motivation and Satisfaction of Urban Open Space - In the Case of Waterfront Open Space in Seoul - (도시 오픈스페이스 방문동기 및 만족도 연구 - 서울시 하천변 오픈스페이스를 중심으로 -)

  • Zoh, Kyung-Jin;Kim, Yong-Gook;Kim, Young-Hyun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.1
    • /
    • pp.27-40
    • /
    • 2014
  • The functions of urban open space, which embraces community revitalization, are diverse. It is the means of public healthcare, learning centers for children, hub of arts and cultural programs, as well as promoter of urban tourism. However, in-depth discourse and research on the topic of urban open spaces has been limited so far. Hence, this study aims to investigate the motivations and satisfaction of visitation based on four representative waterfront open space in Seoul; Cheongyecheon Waterfront, Seoul Forest Park, Seonyudo Park and Banpo Hangang Park. The methods of study are literature review, observation investigation, and questionnaire survey. The findings are analyzed through the Exploratory Factor Analysis, Reliability Analysis, ANOVA Analysis and Regression Analysis by SPSS 18.0. The results of the study are as follows. First, urban waterfront open spaces in Seoul has 5 factors of visitor motivation; community amenity, nature access, cultural and educational assets, aesthetic enjoyment, and lastly means of escape. Second, factors of recognizing urban waterfront open spaces as community amenity and nature access indicate meaningful differences in visitor's perception by spatial characteristics. Third, distances between the destination and the visitor's residence influence significantly their perceived motivation. Close-range visitors perceived nature access as a principal factor, whilst medium to long-range visitors perceived visitation for aesthetic purposes more importantly. Lastly, the will to escape was shown as the influential factor in visitor satisfaction. Visiting open spaces for the enjoyment of nature and aesthetic purposes were factors that also closely relate to visitor satisfaction. In addition, it was found that there are different visitor motivations that influence visitor satisfaction in accordance with the spatial characteristics of each open space. In summary, it can be said that urban waterfront open space is a hybrid space connected to various types of urban contents beyond daily experiences. It was found that several visitor motivations including community development, design aesthetics, education and culture, entertainment, enjoyment of natural landscape, and relaxation, affect the overall satisfaction of the visiting experience. It is anticipated that the results of the study will be used by the local government in setting up strategies for the creation and management of successful urban waterfront open space, and for those involved in planning and design act as a starting point for spatial programming and amenities arrangement in accordance to the city's tourism and urban marketing approach.

Tibial Torsion in Children of the Jeju Area (제주지역 소아의 경골 염전)

  • Song, Dong Ho;Eun, Baik-Lin;Park, Sang Hee;Lee, Joon Young;Tockgo, Young Chang
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.1
    • /
    • pp.75-80
    • /
    • 2005
  • Purpose : Internal tibial torsion is prevalent in East Asian countries such as Korea and Japan, where sitting on the floor is common behavior. Internal tibial torsion or excessive lateral tibial torsion may cause esthetical, functional, or psychological problems and also may induce degenerative arthritis in older age. The purpose of this study is to measure the tibial torsion in children of the Jeju area. Methods : Tibial torsion was measured in 1,042 lower extremities of 521 children from one to 12 years of age. The values of transmalleolar angles were analyzed for each age group divided by 6 months. Quadratic and linear regression models were used to fit patterns of changes in mean values of transmalleolar angles. The age at seven, which provides the highest coefficient of determination for quadratic regression analysis, was used as a cut-off point to fit different statistical models. Results : The mean transmalleolar angle was $0.10{\pm}5.79^{\circ}$ in all children,$ 0.90{\pm}5.49^{\circ}$ in males, and $-0.80{\pm}5.97^{\circ}$ in females. The value was $4.25{\pm}4.04$ in 1 year of age, gradually decreased to the lowest level of $-1.98^{\circ}$ in four years and seven months of age, increased again with age until it reached $0.67{\pm}1.10^{\circ}$ at seven years of age, and stayed at that level thereafter. Conclusion : Internal tibial torsion in infancy is known to correct spontaneously in the normal developing process. But in this study, the mean transmalleolar angle in children of Jeju area annually decreased after one year of age; to the lowest angle at four years and seven months of age; increased again gradually to the age of seven; and persisted in that level, about $10^{\circ}$ less than western children, not correcting further thereafter. These findings suggest tibial torsion might be caused by lifestyle, especially sitting on feet. To prevent abnormalities of joints and gaits, early diagnosis of tibial torsion in childhood and posture correction or early treatment when needed, seems to be necessary.

The Study of Error for Analysis in Dynamic Image from the Error of Count Rates in NaI (Tl) Scintillation Camera (NaI (Tl) 신틸레이션 카메라에서 계수율 오차에 따른 동적 영상 분석치 산출 오류에 관한 연구)

  • Oh, Joo-Young;Kang, Chun-Goo;Kim, Jung-Yul;Park, Hoon-Hee;Oh, Ki-Baek;Kim, Jae-Sam
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.291-297
    • /
    • 2013
  • This study is aimed to evaluate the effect of $T_{1/2}$ upon count rates in the analysis of dynamic scan using NaI (Tl) scintillation camera, and suggest a new quality control method with this effects. We producted a point source with $^{99m}TcO_4^-$ of 18.5 to 185 MBq in the 2 mL syringes, and acquired 30 frames of dynamic images with 10 to 60 seconds each using Infinia gamma camera (GE, USA). In the second experiment, 90 frames of dynamic images were acquired from 74 MBq point source by 5 gamma cameras (Infinia 2, Forte 2, Argus 1). There were not significant differences in average count rates of the sources with 18.5 to 92.5 MBq in the analysis of 10 to 60 seconds/frame with 10 seconds interval in the first experiment (p>0.05). But there were significantly low average count rates with the sources over 111 MBq activity at 60 seconds/frame (p<0.01). According to the second analysis results of linear regression by count rates of 5 gamma cameras those were acquired during 90 minutes, counting efficiency of fourth gamma camera was most low as 0.0064%, and gradient and coefficient of variation was high as 0.0042 and 0.229 each. We could not find abnormal fluctuation in $x^2$ test with count rates (p>0.02), and we could find the homogeneity of variance in Levene's F-test among the gamma cameras (p>0.05). At the correlation analysis, there was only correlation between counting efficiency and gradient as significant negative correlation (r=-0.90, p<0.05). Lastly, according to the results of calculation of $T_{1/2}$ error from change of gradient with -0.25% to +0.25%, if $T_{1/2}$ is relatively long, or gradient is high, the error increase relationally. When estimate the value of 4th camera which has highest gradient from the above mentioned result, we could not see $T_{1/2}$ error within 60 minutes at that value. In conclusion, it is necessary for the scintillation gamma camera in medical field to manage hard for the quality of radiation measurement. Especially, we found a tendency that count rate changes over time at this study, and we proved that it can effect $T_{1/2}$. And also, there is need of appropriate phantoms and the method of quality management like this study, because there are not any advice or limitation degrees for domestic medical purpose scintillation camera.

Clinical Application Analysis of 3D-CRT Methods Using Tomotherapy (토모테라피를 이용한 3차원 입체 조형 치료의 임상적 적용 분석)

  • Cho, Kang-Chul;Kim, Joo-Ho;Kim, Hun-Kyum;Ahn, Seung-Kwon;Lee, Sang-Kyoo;Yoon, Jong-Won;Cho, Jeong-Hee;Lee, Jong-Seok;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.327-335
    • /
    • 2013
  • This study investigates the case of clinical application for TomoDirect 3D-CRT(TD-3D) and TomoHelical 3D-CRT(TH-3D) with evaluating dose distribution for clinical application in each case. Treatment plans were created for 8 patients who had 3 dimensional conformal radiation therapy using TD-3D and TH-3D mode. Each patients were treated for sarcoma, CSI(craniospinal irradiaion), breast, brain, pancreas, spine metastasis, SVC syndrome and esophagus. DVH(dose volume histogram) and isodose curve were used for comparison of each treatment modality. TD-3D shows better dose distribution over the irradiation field without junction effect because TD-3D was not influenced by target length for sarcoma and CSI case. In breast case, dosimetric results of CTV, the average value of D 99%, D 95% were $49.2{\pm}0.4$ Gy, $49.9{\pm}0.4$ Gy and V 105%, V 110% were 0%, respectively. TH-3D with the dosimetric block decreased dose of normal organ in brain, pancreas, spine metastasis case. SCV syndrome also effectively decreased dose of normal organ by using dose block to the critical organs(spinal cord <38 Gy). TH-3D combined with other treatment modalities was possible to boost irradiation and was total dose was reduced to spinal cord in esophagus case(spinal cord <45 Gy, lung V 20 <20%). 3D-CRT using Tomotherapy could overcomes some dosimetric limitations, when we faced Conventional Linac based CRT and shows clinically proper dose distribution. In conclusion, 3D-CRT using Tomotherapy will be one of the effective 3D-CRT techniques.