• Title/Summary/Keyword: 비상차단시스템

Search Result 29, Processing Time 0.024 seconds

Remote Monitoring Panel and Control System for Chemical, Biological and Radiological Facilities (화생방 방호시설을 위한 원격감시 패널 및 제어시스템)

  • Park, Hyoung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.464-469
    • /
    • 2019
  • A remote monitoring panel and control system was developed to control various valves and access control chambers, including gas shutoff valves used in CBR(Chemical, Biological and Radiological) facilities. The remote monitoring panel consisted of a main panel installed in the NBC (Nuclear, Biological and Chemical) control room and auxiliary panel installed in the clean room, and the size was divided into pure control and control including CCTV. This system can be monitored and controlled remotely according to the situation where an explosion door and gas barrier door can occur during war and during normal times. This system is divided into normal mode and war mode. In particular, it periodically senses the operation status of various valves, sensors, and filters in the CBR facilities to determine if each apparatus and equipment is in normal operation, and remotely alerts situation workers when repair or replacement is necessary. Damage due to the abnormal operation of each device in the situation can be prevented. This enables control of the blower, supply and exhaust damper, emergency generator, and coolant pump according to the state of shutoff valve and positive pressure valve in the occurrence of NBC, and prevents damage caused by abrupt inflow of conventional weapons and nuclear explosions.

Development of Door Control Unit for the Electric Plug-in Door of Subway Train (전동차 전기식 플러그도어 출입문 제어 장치 개발)

  • Joung, Eui-Jin
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.4
    • /
    • pp.47-53
    • /
    • 2011
  • The Electric Multiple Unit (EMU) has many types of door system such as sliding door, plug door etc.al. according to customer's requirements. The sliding door is widely used in Korea but has weak point in the noise problem. In the low operation speed, the noise coming from outer side of the EMU is not an important factor. As the speed is higher than before, noise is increased and make a problem. The main cause of noise is the imperfect air tightness in the EMU. The plug door system has advantages for the noise reduction characteristic in the high speed area. We have been developing electric plug-in door. The door is controlled by Door Control Unit(DCU) following the order of Automatic Train Protection (ATP) that is a kind of train signalling system. DCU has to simultaneously open and close the doors and the operation of it is related to the passengers safety. So DCU is a safety device that is important to reliability and safety. DCU is composed of several devices of control, motor driving, Input/Output, communication and power. In this paper, we will describe the functions, characteristic, requirement, subsystem and test results of DCU used for the electric plug-in door.

A Study on Institutional Foundation on the Korea Counter-Terrorism System (한국 테러대응 시스템의 제도적 구축방안)

  • Kwon, Jeong-Hoon
    • Korean Security Journal
    • /
    • no.25
    • /
    • pp.27-61
    • /
    • 2010
  • This study looks at plans for the efficient functions of the current terror response system in Korea. The results are derived from by comparing and analyzing American, British, German, Japanese, and Korean terror response systems. It focuses especially on addressing some problems with Korea's terror response system and how to operate it effectively. The study will systematically compare and analyze each nation's terror countermeasure studying organizational, functional, and legal aspects as standards. This study shows that there is not an exclusive terror response center in Korea compared with other nations such as America, the United Kingdom, Germany, and Japan. Also it is difficult to expect effective and vigorous operations due to weak cooperation across the relevant organizations. The presidential directive of the state's anti-terrorism action guidelines is legally ineffective. This means that on legal grounds, it is difficult to take actions to prevent the terrorism. Therefore, keys to counteracting terrorism derived from this study are summarized below. In the first place, an integrated terror response system should be set up for expansion of information sharing which leads to emergence effect. In the second place, the superior legislative systems should be made for the cleardefinition and extent of what the terror is, rigid enforcement of investigation, immigration, and keeping an eye on the funds raised by terrorists and tracking down the terrorists, the plan for eco-terrorism. In the third place, to augment security of vital facilities and peoples' awareness of terrorism safety should be emphasized and a cooperative system between civil and government organizations need to be built. In the fourth place, system for crisis management must be provided in an effort to maximize management system of terrorism and unify a decentralized emergency countermeasures effectively.

  • PDF

Estimation of Effect Zone for the Establishment of Damage-Minimizing Plan of Chemical Plants (화학공장의 사고피해 최소화 대책수립을 위한 영향범위 평가)

  • Lee, Hern-Chang;Han, Seong-Hwan;Cho, Ji-Hoon;Shin, Dong-Il;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.2
    • /
    • pp.69-74
    • /
    • 2011
  • As a way to propose a method for the establishment of practical damage-minimizing plan for chemical plants, the release scenario was established by using API-581 BRD and the effect zone was estimated by the KS-RBI program supporting the quantitative cause analysis. And the risk assessment was performed. As a result, we found that to minimize the damage of a chemical plant, it is effective to use four release hole diameters (small, medium, large and rupture) and release time estimated according to the classes of detection and isolation systems. In addition, it can be safely said that through appling the damage areas considering weighted average by failure frequency and worst-case simultaneously, industrial sites can come up with the effective emergency response plan.

A Study on Security Plans At Large-Scale International Event Halls: Focusing on Assessment of Escape Safety of K Stadium for The Incheon Asian Games (대규모 국제행사장의 경호경비계획에 관한 연구: 인천 아시안게임 K경기장의 피난안전성 평가를 중심으로)

  • Park, Nam-Kwun;Lee, Young-Ju;Yoon, Myong-O
    • Korean Security Journal
    • /
    • no.30
    • /
    • pp.7-32
    • /
    • 2012
  • Korea faces The 2014 Incheon Asian Games and 2018 Pyungchang Winter Olympics. It is imperative to hold a safe event for the economic benefits, enhancing Korea's image, social integration, national harmony and unity in order to be evaluated as a successful international event. Furthermore, since the international event tends to draw many spectators, the host country must be ready to accommodate a large number of injured people in the event of an accident or terror attack. As stadiums for international events are where a large number of spectators gather in, a large refuge is essential, when dangerous situations happen. In this study, evacuation simulation was conducted using three scenarios in order to predict escape behaviors of spectators during the large escape by destruction of safety systems of stadiums and assess escape safety. As the result, the following results and proposals were extracted. Firstly, it is considered that dangerous situations during the security of stadiums should be predicted in advance and concrete plans for a large refuge of spectators have to be established to minimize damage. Secondly, it was found that the reduction in evacuation exits has an important impact on evacuation in an emergency situation. It implies that securing escape exits are quite important. Thirdly, there were areas where spectators stayed, due to blocked escape exits, while they were dispersed and concentrated at once. It demonstrates that security plans considering properties of facilities are required to solve these problems.

  • PDF

A Study on the System for Improving the Safety Device of the Hydrogen Fluoride ISO Tank (AHF ISO Tank의 안전성 향상을 위한 안전장치에 관한 연구)

  • Park, Sang Bae;Lee, Chang Jun
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.3
    • /
    • pp.54-62
    • /
    • 2020
  • Watching the leakage accident of the Gumi Hube Global AHF(Anhydrous fluoric Acid), I experienced how much chemical accidents affect on our society. Since then, many studies have been conducted on chemical accident in many fields. The use department wanted to find improvement plans for the process system and apply them to the field. The safety field wanted to study improvement of safety through the analysis of damage effects and apply them to emergency response to reduce damage effects. In this study, Mechanical safe devices have been applied which can respond quickly to chemical accidents occurring during the charging operation to enhance the safety of the AFH ISO Tank(Anhydrous fluoric Acid International Organization for Standardization Tank). Investigation of similar tanks confirmed that other chlorine tanks with the same working procedure as AHF ISO Tank have a mechanical safety device, EFV(Excess Flow Valve). Applicability and performance for emergency shutdown when EFV is introduced in AHF ISO Tank can be verified by comparing and examining the accident situation of Hube Global Accident and the accident in Ulsan 2018. Comparing accident cases, expected performance and applicability, It is suggested that EFV, a mechanical safety device that can reduce damage from chemical accidents to the tank and handle accidents early, should be introduced to the tank.

Analysis of Building Characteristics and Temporal Changes of Fire Alarms (건물 특성과 시간적 변화가 소방시설관리시스템의 화재알람에 미치는 영향 분석 연구)

  • Lim, Gwanmuk;Ko, Seoltae;Kim, Yoosin;Park, Keon Chul
    • Journal of Internet Computing and Services
    • /
    • v.22 no.4
    • /
    • pp.83-98
    • /
    • 2021
  • The purpose of this study to find the factors influencing the fire alarms using IoT firefighting facility management system data of Seoul Fire & Disaster Headquarters, and to present academic implications for establishing an effective prevention system of fire situation. As the number of high and complex buildings increases and former bulidings are advanced, the fire detection facilities that can quickly respond to emergency situations are also increasing. However, if the accuracy of the fire situation is incorrectly detected and the accuracy is lowered, the inconvenience of the residents increases and the reliability decreases. Therefore, it is necessary to improve accuracy of the system through efficient inspection and the internal environment investigation of buildings. The purpose of this study is to find out that false detection may occur due to building characteristics such as usage or time, and to aim of emphasizing the need for efficient system inspection and controlling the internal environment. As a result, it is found that the size(total area) of the building had the greatest effect on the fire alarms, and the fire alarms increased as private buildings, R-type receivers, and a large number of failure or shutoff days. In addition, factors that influencing fire alarms were different depending on the main usage of the building. In terms of time, it was found to follow people's daily patterns during weekdays(9 am to 6 pm), and each peaked around 10 am and 2 pm. This study was claimed that it is necessary to investigate the building environment that caused the fire alarms, along with the system internal inspection. Also, it propose additional recording of building environment data in real-time for follow-up research and system enhancement.

A Study Security Measures for Protection of VIP in the G20 Summit (G20 정상회의 시 주(主)행사장에서의 VIP 안전대책 방안에 관한 연구)

  • Lee, Sun-Ki;Lee, Choong-Soo
    • Korean Security Journal
    • /
    • no.24
    • /
    • pp.91-123
    • /
    • 2010
  • The threat factors available for occurrence given G20 Summit Meeting are expected leader terrorism, hostage terrorism, bomb terrorism, public facilities terrorism, and aircraft terrorism. As for the threat groups, which are expected in Korea, the North Korea, Islam extremist group, and the group such as NGO organization of being opposed to international meeting are regarded as having possibility of causing hazard. Thus, the purpose of this study is to suggest VIP Security-measure plans in the main site in preparation for G20 Summit Meeting. Accordingly, each country in the world is adopting 'the principle of Triple Ring' in common. Thus, it elicited a coping plan by 1st line(inner ring) 2nd line(middle ring) 3rd line(outer ring) based on this principle, and proposed even an opinion together that will need to be reflected in light of policy for the VIP security measures. In conclusion, as for the VIP Security-measure plans in the main site in preparation for G20 Summit Meeting, In the inner ring(safety sector), first, an intercepting measure needs to be devised for a spot of getting into and out of vehicles given the Straight Street. Second, the Walking Formation needs to be reinforced boldly in the exposed area. In the middle ring(security sector), first, the control plan needs to be devised by considering particularity of the main site. Second, there is necessity for adopting the efficient security badge operation plan that is included RFID function within security badge. In the outer ring(aid protective sector), first, there is necessity of preparing for several VIP terrorisms, of collecting information and intelligence, and of reinforcing the information collection system against terrorism under the cooperation with the overseas information agency. Second, the urgent measure training in time of emergency needs to be carried out toward security agent event manpower. Third, to maintain the certain pace in VIP motorcade, the efficient traffic control system needs to be operated. Finally, as for what will need to be reflected in light of policy for VIP security measures, first, there is necessity for allowing VIP residence to be efficiently dispersed to be distributed and controlled. Second, there is necessity for allowing impure element to misjudge or attack to be failed by utilizing diverse deception operations. Third, according to the reorganization in North Korea's Organization of the South Directed Operations, the powerful 'military-support measure' needs to be driven from this G20 Summit Meeting. For this, the necessity was proposed for further reinforcing the front back defense posture under the supervision of the Ministry of National Defense and for positively coping even with detecting and removing poison in preparation for CBR (chemical, biological, and radio-logical) terrorism.

  • PDF

A Study on Effect of B/L's Exemption Clauses Relating to the Governing Law of English Law (영국법의 준거법과 관련한 선하증권 면책약관의 효력에 관한 연구)

  • Han, Nak-Hyun;Jung, Jun-Sik
    • Journal of Korea Port Economic Association
    • /
    • v.22 no.4
    • /
    • pp.1-17
    • /
    • 2006
  • In the Bill of Lading of The Irbenskiy Proliv is not subject to the Hague-Visby Rules in accordance with paragraphs (A) and/or (E) of cl.1 or to the Hague Rules in accordance with paragraphs (B) and/or (D) of cl.1. The Irbenskiy Proliv is very rare case that is effective to exempt the carrier as literal words of Bill of Lading. The action concerns cargoes of perishable goods shipped from Brazil to Japan, under Bills of Lading each of which contained an extensive carrier's exemption clause. A preliminary issue was ordered to be determined on the question whether c1.4 is effective to exempt the ralliers from any potential liability for the claims in this case. The court held that there is no reason to reject c1.4 as part of each of the contracts contained in or evidenced by the bills of lading; and it protects the carrier where damage to the goods shipped results from such causes. It is therefore effective to exempt the carriers from any potential liability for those claims.

  • PDF