• Title/Summary/Keyword: 비대칭 단면

Search Result 123, Processing Time 0.017 seconds

Preparation of Polyethersulfone Ultrafiltration Membranes Containing $ZrO_2$ Nanoparticles by Combining Phase-inversion Method/Sol-gel Technique (상변환/졸-겔법에 의한 $ZrO_2$ 나노입자 함유 Polyethersulfone 한외여과 막의 제조)

  • Youm, Kyung-Ho;Lee, Yun-Jae
    • Membrane Journal
    • /
    • v.16 no.4
    • /
    • pp.303-312
    • /
    • 2006
  • The asymmetric hybrid membranes of polyethersulfone (PES) and $ZrO_2$ nanoparticles were prepared via new one-step procedure combining simultaneously the phase-inversion method and the sol-gel technique. The optimum contents of $Zr(PrO)_4\;and\;HNO_3$ catalyst were determined by the adsorption experiments of phosphate anion onto the resulting hybrid membranes. The maximum adsorption of phosphate anion is obtained at the conditions of 0.15 mL $Zr(PrO)_4$ addition per 1 mL PES and 30 mL $HNO_3$ addition per 1 mL $Zr(PrO)_4$. Variation of morphology, performance and incorporated $ZrO_2$ amount of the resulting hybrid membranes were discussed and determined using SEM, pure water flux, TGA, ICP, XRD and contact angle measurements. Increasing $Zr(PrO)_4$ addition into casting solution, pure water flux is increased and $ZrO_2$ amount in the hybrid membrane is maximized at the conditions 0.15 mL $Zr(PrO)_4$ addition per 1 mL PES. The prephosphatation of PES-$ZrO_2$ hybrid membrane was studied to modify the surface characteristics of membrane. Ultrafiltration of bovine serum albumin (BSA) solution was performed in a dead-end cell using both a bare (non-phosphated) and a phosphated hybrid membrane. It is revealed that both the permeate flux and BSA rejection were increased as about 40% by prephosphatation of hybrid membrane. These results may be explained on the basis of the increase of membrane hydrophilicity, which was determined from contact angle measurements.

Effect of Oxygen Incorporation in the Fabrication of TiN Thin Film for Frame by UBM Sputtering System (UBM Sputtering System에 의한 안경테용 TiN막 제작에 있어 Oxygen 영향 연구)

  • Park, Moon Chan;Lee, Jong Geun;Joo, Kyung Bok;Lee, Wha Ja;Kim, Eung Soon;Choi, Kwang Ho
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.63-68
    • /
    • 2009
  • Purpose: TiN films were deposited on sus304 by unbalanced magnetron sputtering system which was designed and developed as unbalancing the strength of the magnets in the magnetron electrode. The effect of oxygen incorporation in the fabrication of deposited films was investigated. Methods: The cross sections of deposited films on Silicon wafer were observed by SEM to measure the thickness of the films, the components of the surface of the films were identified by XPS survey spectra, the compositional depth-profile of deposited films was examined by an XPS apparatus. Results: From the data of XPS depth profile of films, it could be seen that the element O as well as the elements Ti and N present in the surface of the film and the relative percentage of the element O was constant at 65 at.% with respect to the depth of film. Conclusions: The color change with thickness of the films had something to do with the change of Ti $ 2p_{3/2}$ peak intensity and shape mixed of $ TiO_2$, TiN, $ TiO_{x}N_{y}$ compound.

  • PDF

Connection Performance of Steel Moment Frame with Out-of-Plane Beam Skew (면외방향 어긋난 보를 갖는 철골모멘트골조의 접합부 성능)

  • Hong, Jong-Kook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.2
    • /
    • pp.84-91
    • /
    • 2022
  • This study investigated the behavior of out-of-plane skewed moment connections that were designed as IMFs, as per the Korean standards. A total of 14 finite element models were constructed with the consideration of two types (single- and double-sided connections) and four levels of skew angle (0°, 10°, 20°, and 30°). The results indicated that the skewed connections considered in this study met the acceptance criteria for IMFs given by the codes. However, the load-carrying capacities of skewed connections were decreased as the skew angle increased. For the connection with a skew angle of 30°, the peak load was noted to be 13% less and the energy dissipation capacity could be 26% less than that of non-skewed connection. In addition, because of the skewed nature, the stress distribution in the skewed beam flange near the connection was asymmetric and the stresses were concentrated on the beam inner flange. Column twisting induced by the skewed configuration was very small and negligible in the beam and column combination considered in this study.