• Title/Summary/Keyword: 비교 연구 방법론

Search Result 2,674, Processing Time 0.04 seconds

Influence of Parotid from Various Dose Rate in Intensity Modulated Radiation Therapy Planning for Head and Neck Cancer (두경부암 세기변조방사선치료 계획 시 선량율 변화가 이하선에 미치는 영향)

  • Hong, Joo-Wan;Jeong, Yun-Ju;Won, Hui-Su;Chang, Nam-Jun;Choi, Ji-Hun;Seok, Jin-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.105-111
    • /
    • 2010
  • Purpose: There are various beam parameter in intensity modulated radiation therapy (IMRT). The aim of this study is to investigate how various dose rate affect the parotid in treatment plan of IMRT. Materials and Methods: The study was performed on 10 nasopharyngeal carcinoma patients who have undergone IMRT. CT images were scanned 3 mm of thickness in the same condition and the treatment plan was performed by Eclipse (Ver.7.1, Varian, Palo Alto, USA). The parameters for planning used 6 MV energy and 8 beams under the same dose volume constraint. The variation of dose rates were used 300, 400, 500 MU/min. The mean dose of both parotid was accessed from the calculated planning among the 10 patients. The mean dose of parotid was verificated by 2D diode array (Mapcheck from Sun Nuclear Corporation, Melbourne, Florida). Also, Total monitor unit (MU) and beam-on time was analysed. Results: According to the dose rate, the mean dose of parotid was increased by 0.8%, 2.0% each, when dose rate was changed from 300 MU/min to 400, 500 MU/min, moreover Total MU was increased by 5.4% and 10.6% each. There was also a dose upward trend in the dose measurement of parotid by 2D diode array. However, beam - on time difference of 1~2 minutes was no signigicant in the dose rate increases. Conclusion: From this study, when the dose rates increase, there was a signigicant increase of Total MU and the parotid dose accordingly, however the shortened treatment time was not significant. Hence, it is considered that there is a significant decrease of late side effect in parotid radiation therapy, if the precise dose rate in IMRT is used.

  • PDF

Evaluation of Setup Error Correction for Patients Using On Board Imager in Image Guided Radiation Therapy (Image Guided Radiation Therapy (IGRT) 시 On Board Imager를 이용한 환자 Setup Error 보정평가)

  • Kang, Soo-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.69-81
    • /
    • 2008
  • Purpose: To reduce side effects in image guided radiation therapy (IGRT) and to improve the quality of life of patients, also to meet accurate SETUP condition for patients, the various SETUP correction conditions were compared and evaluated by using on board imager (OBI) during the SETUP. Materials and Methods: Each 30 cases of the head, the neck, the chest, the belly, and the pelvis in 150 cases of IGRT patients was corrected after confirmation by using OBI at every 2∼3 day. Also, the difference of the SETUP through the skin-marker and the anatomic SETUP through the OBI was evaluated. Results: General SETUP errors (Transverse, Coronal, Sagittal) through the OBI at original SETUP position were Head & Neck: 1.3 mm, Brain: 2 mm, Chest: 3 mm, Abdoman: 3.7 mm, Pelvis: 4 mm. The patients with more that 3 mm in the error range were observed in the correction devices and the patient motions by confirming in treatment room. Moreover, in the case of female patients, the result came from the position of hairs during the Head & Neck, Brain tumor. Therefore, after another SETUP in each cases of over 3 mm in the error range, the treatment was carried out. Mean error values of each parts estimated after the correction were 1 mm for the head, 1.2 mm for the neck, 2.5 mm for the chest, 2.5 mm for the belly, and 2.6 mm for the pelvis. Conclusion: The result showed the correction of SETUP for each treatment through OBI is extremely difficult because of the importance of SETUP in radiation treatment. However, by establishing the average standard of the patients from this research result, the better patient satisfaction and treatment results could be obtained.

  • PDF

Internal Mammary Lymph Node Irradiation after Breast Conservation Surgery: Radiation Pneumonitis versus Dose-Volume Histogram Parameters (유방보존술 후 내유림프절 방사선 조사: 방사선 폐렴과 체적-선량 히스토그램 변수들)

  • Kim, Joo-Young;Lee, Ik-Jae;Keum, Ki-Chang;Kim, Yong-Bae;Shim, Su-Jung;Jeong, Kyoung-Keun;Kim, Jong-Dae;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.261-267
    • /
    • 2007
  • Purpose: To evaluate the association between radiation pneumonitis and dose-volume histogram parameters and to provide practical guidelines to prevent radiation pneumonitis following radiotherapy administered for breast cancer including internal mammary lymph nodes. Materials and Methods: Twenty patients with early breast cancer who underwent a partial mastectomy were involved in this study. The entire breast, supraclavicular lymph nodes, and internal mammary lymph nodes were irradiated with a dose of 50.4 Gy in 28 fractions. Radiation pneumonitis was assessed by both radiological pulmonary change (RPC) and by evaluation of symptomatic radiation pneumonitis. Dose-volume histogram parameters were compared between patients with grade <2 RPC and those with grade ${\geq}$2 RPC. The parameters were the mean lung dose, V10 (percent lung volume receiving equal to and more than 10 Gy), V20, V30, V40, and normal tissue complication probability (NTCP). Results: Of the 20 patients, 9 (45%) developed grade 2 RPC and 11 (55%) did not develop RPC (grade 0). Only one patient developed grade 1 symptomatic radiation pneumonitis. Univariate analysis showed that among the dose-volume histogram parameters, NTCP was significantly different between the two RPC grade groups (p<0.05). Fisher's exact test indicated that an NTCP value of 45% was appropriate as an RPC threshold level. Conclusion: This study shows that NTCP can be used as a predictor of RPC after radiotherapy of the internal mammary lymph nodes in breast cancer. Clinically, it indicates that an RPC is likely to develop when the NTCP is greater than 45%.

Application of Radiological Study by Small Bowel Disease - Comparison of Diagnostic Results of Small Bowel Series and Abdominal Pelvic Computed Tomography - (소장 질환별 방사선학적 검사의 적용에 관한 연구 - 소장조영술과 복부골반전산화단층촬영의 결과 분석을 중심으로 -)

  • Lee, Hee-Jung;Son, Soon-Yong;Lee, Won-Hong
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.279-286
    • /
    • 2005
  • Purpose : There are two modalities, those are small bowel series(SBS) and abdominal pelvic computed tomography(CT), for diagnosis of small bowel disease. The aim of this study is to lend radiological technologists who are doing the two modalities assistance in the understanding characteristic of disease by comparing the two results. Meterials and method : 284 patients were examined the two SBS and abdominal pelvic CT together from 1999 to 2003. 250 ml $BaSO_4$ suspension 40 w/v% and 600ml carboxy methyl cellulose 0.5 w/v% were used for SBS. Abdominal Pelvic CT was examined in one hour before taking 450 ml $BaSO_4$ suspension 1.5 w/v%. The CT scan was done in 72 sec after 150 ml contrast media injection. the used protocol was helical mode 5:5 mm pitch 1.375:1, speed 27.50, exposure 120 kv, 240 mA, tube rotation time 0.5 sec. the statistic analysis was conducted with statistical program SPSS 10 version with frequency and crossing analysis. P-value less than 0.05 were considered significant. Results : In the results of SBS, normal findings were 131 patients(46.1%), inflammatory bowel disease(IBD) 64(22.9%), ischemia+ileocolitis+vasculitis 22(7.7%), Obstruction+stricture 21(7.7%) and Others 45(15.9%). In the results of abdominal pelvic CT, normal findings were 103 patients(36.3%), inflammatory bowel disease 65(22.9%), wall thickening+lymphadenopathy 42(14.8%), Fluid collection 17(6%), and Others 57case(20%). The same results of the two were 130patients(45.8%). 30patients(10.6%) of normal finding in SBS were diagnosed as wall thickening+lymphadenopathy and IBD in CT, and 15patients(5.3%) of normal finding in CT were diagnosed as ischemia+ileocolitis+vasculitis, mass and IBD in SBS(p<0.05). Transit time delay was diagnosed in 10patients(3.5%) on only SBS, wall thickening+lymphadenopathy was diagnosed in 20patients(7%) in only CT(p<0.05). Conclusion : We think that proper examination method will be selected in the small bowel disease, if we understand the characteristics of the disease and method.

  • PDF

The Accuracy of Barr, Blethyn and Leech Scoring Systems on Plain Abdominal Radiographs in Childhood Constipation (소아에서 단순 복부 X-선 사진으로 변비를 진단하는데 있어 Barr, Blethyn과 Leech 점수체계의 정확도)

  • Moon, Ji-Young;Moon, Kyung-Rye
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.10 no.1
    • /
    • pp.44-50
    • /
    • 2007
  • Purpose: The role of plain, abdominal radiography in childhood constipation has not been fully evaluated. The aim of this study was to determine the accuracy and reliability of scoring systems assessing a fecal load on plain, abdominal radiographs in children with functional constipation. Methods: Plain, abdominal radiographs from 38 constipated children and 39 control children were examined by four independent inspectors, pediatric residents. Four inspectors independently scored the radiographs according to three different scoring systems Barr, Blethyn, and Leech. No clinical information about the patients was available to the inspectors. Each abdominal radiograph was evaluated on two separate occasions, one week apart. Kappa coefficients were calculated as indicators of inter-and intra-inspector variability, coefficients <0.20, 0.21~0.40, 0.40~0.60, 0.61~0.80 and 0.81~1.00 were considered to indicate poor, fair, moderate, good, and very good agreement, respectively. Results: The Leech score showed the highest reproducibility: the inter-inspector agreement was uniformly very good on two separate occasions (${\kappa}$ values of 0.88, 0.91, 0.92, 0.86 in the first time and 0.81, 0.88, 0.89, 0.84 in the second time). Agreement using the Barr score was good (${\kappa}$ values of 0.66, 0.67, 0.69, 0.66 in the first time and 0.68, 0.65, 0.71, 0.68 in the second time). However, agreement for the Blethyn score was the lowest of the three scoring systems. The Leech scoring system had the highest sensitivity and specificity compared to the Barr scoring system for the diagnosis of functional constipation by plain, abdominal radiographs. Conclusion: The Leech score appeared to be a more accurate and reliable method because of its high sensitivity and specificity for evaluating the fecal load on plain, abdominal radiographs in children with functional constipation. Therefore, the Leech scoring system was found to be the most useful for assessment for the degree of constipation on plain, abdominal radiographs in children.

  • PDF

Comparison of Clinical Outcome According to the Duration of Corticosteroid Therapy in Childhood Henoch-$Sch{\ddot{o}}nlein$ Purpura: a Bicentric Study (소아 Henoch-$Sch{\ddot{o}}nlein$ purpura에서 스테로이드 치료 기간에 따른 임상적 결과의 비교)

  • Lee, Su-Jin;Shin, Jae-Il;Lee, Chong-Guk;Kim, Kee-Hyuck
    • Childhood Kidney Diseases
    • /
    • v.12 no.2
    • /
    • pp.170-177
    • /
    • 2008
  • Purpose : The aim of this study was to evaluate whether the incidence of relapse or nephritis might be influenced by the duration of corticosteroid therapy in children with Henoch-Schonlein purpura(HSP). Methods : We retrospectively analyzed 186 children with a diagnosis of HSP in two major hospitals in Ilsan, Korea from the years 2000 to 2003. To evaluate whether renal involvement or relapse might be influenced by the duration of corticosteroid therapy in children with HSP, one pediatric nephrologist from hospital A, maintained corticosteroid therapy for at least 2 weeks(Group A, n=94). The other from hospital B used only during the symptomatic period(Group B, n=92). Results : There were no significant differences in age, sex, body weight, white blood cell count, hemoglobin, hematocrit, platelet count, serum protein and albumin levels between the two groups. The incidence of abdominal pain or arthralgia also did not differ between two groups. However, the duration of steroid therapy was significantly longer in Group A than in Group B and the cumulative dose of prednisolone was also higher in Group A than in Group B. The development of nephritis was more frequent in Group A. Conclusion : The longer duration of steroid use was not associated with the decreased rate of nephritis. Therefore, corticosteroids should be used carefully in a selected group of HSP children, and be tapered rapidly after control of the acute symptoms.

Immunohistochemical Analysis for the Expression of p27, CDK4, and Uteroglobin in Resected Non-small Cell Lung Cancer (수술로 절제된 비소세포폐암에서 세포주기와 관련된 p27, CDK4, Uteroglobin의 발현에 관한 면역조직학적 분석)

  • Baek, Man-Sun;Hong, Seok-Gyun;Hong, Hyun-Ju;Um, Sang-Won;Lee, Kye-Young;Kim, Woo-Ho;Lee, Choon-Taek;Yoo, Chul-Gyu;Han, Sung-Koo;Shim, Young-Soo;Kim, Young-Whan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.3
    • /
    • pp.253-264
    • /
    • 2002
  • Background : It has been reported that the expression of protein which influences on the cell cycle is significantly involved in the development, progress, treatment response, and survival of cancer, and also that the degree of expression of p27 and CDK4 is related to the prognosis. Recent research has revealed that uteroglobin, tumor suppressor gene, is related to cell cycle. This study is focused on the relations between expression of proteins related to cell cycle and clinical index of and survival of NSCLC. Methods : We examined immunohistochemically specimens of 110 surgically resected NSCLCs for expression of p27, CDK, Uteroglobin. Tissue array slide were obtained from 110 surgically resected NSCLCs. Immunohistochemical staining was performed by immuno-peroxidase technique using avidin-biotinylated horseradish peroxidase complex. Results : In 110 patients with resected NSCLCs, the ratio of male to female was 87:13, the median age was $56.43{\pm}9.41$ yrs. The positive staining of p27 was detected in 75% of the cases. A non-statistically significant trend toward increased p27 expression was observed in smoker and squamous cell cancer. The positive staining of CDK4 was detected in 89%, which was the highest expression of protein among 3 types. The survival ratio of CDK4 negative staining group was higher than that of positive staining group, which was significant diffrernce(P<0.05). There was no association between p27 or uteroglobin expression and survival. Conclusion : The expression degree of CDK4 is related to the prognosis. This findings suggests that the measurement of CDK4 may be useful in identifying patient at high risk for disease recurrence and survival.

Measurement of Nitric Oxide in the Differential Diagnosis of Lymphocytic Pleural Effusion (림프구성 흉막염의 감별 진단에서 NO(nitric oxide)의 측정)

  • Kim, Tae-Hyung;Sohn, Jang Won;Yoon, Ho Joo;Shin, Dong Ho;Park, Sung Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.4
    • /
    • pp.361-367
    • /
    • 2005
  • Background : Differential diagnosis of lymphocytic pleural effusion is difficult even with many laboratory findings. Nitric oxide(NO) level is higher in the sputum or exhaled breath of patients with active pulmonary tuberculosis than in those without tuberculosis. In addition, there are some reports about the increased level of NO metabolites in body fluids of cancer patients. However, there is no data on the NO levels in the pleural fluid of patients with tuberculous pleurisy. Method : The serum and pleural fluid NO in the patients with acute lymphocytic pleural effusion were analyzed. Results : Of total 27 patients, there were 14 males and average age of patients was 48 years. The final diagnosis was tuberculous pleurisy in 17 cases and malignant pleural effusion in 10. The pleural fluid NO level was $540.1{\pm}116.4{\mu}mol$ in the tuberculous pleurisy patients and $383.7{\pm}71.0{\mu}mol$ in the malignant pleural effusion patients. The serum NO level was $624.7{\pm}142.0{\mu}mol$ in tuberculous pleurisy patients and $394.4{\pm}90.4{\mu}mol$ in malignant pleural effusion patients. There was no significant difference in the serum and pleural fluid NO level between the two groups. The NO level in the pleural fluid showed a significant correlations with the pleural fluid neutrophil count, the pleural fluid/serum protein ratio, and pleural fluid/serum albumin ratio (p<0.05 in each). The protein concentration, leukocyte and lymphocyte count in the pleural fluid were significantly higher in the tuberculous pleurisy patients than the malignant pleural effusion patients (p<0.05 in each). Conclusion : NO is not a suitable marker for a differential diagnosis of lymphocytic pleural effusion. However, the NO level in the pleural fluid might be associated with the neutrophil recruitment and protein leakage in the pleural space.

A Study of Quality Control of Nuclear Medicine Counting System and Gamma Camera (핵의학 계측기기 및 감마카메라의 정도관리 연구)

  • 손혜경;김희중;정해조;정하규;이종두;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.103-112
    • /
    • 2001
  • Purpose: The purpose of this study was to investigate the current status of performing nuclear medicine quality control in korea and to test selected protocols of quality control of nuclear medicine counting system and gamma camera. Materials and Methods: Fifty three hospitals were included to investigate the current status of nuclear medicine quality control in korea. The precision of dose calibrator and thyroid uptake system was measured with Tc-99m 35.52 MBq for 2 minuets and Tc-99m 5.14 MBq for 10 sec every one minute, respectively. The sensitivity of CeraSPECT$^{TM}$ with low energy high resolution parallel hole collimator was measured using two cylindrical phantoms with 15 cm in diameter and 12 cm and 30 cm in heights containing Tc-99m. The correction factor for sensitivity of CeraSPECT$^{TM}$ was calculated using phantom data. The system planar sensitivity, uniformity, count rate and spatial resolution were measured for Varicam gamma camera with low energy high resolution parallel hole collimator using 140 keV centered 20% energy window, 256$\times$256 or 512$\times$512 matrix sizes. Results: The quality control of dose calibrator and well counter were showed poor performance status. On the other hand, The quality control of gamma camera and other systems were showed relatively good performance status. The results of precision of dose calibrator and thyroid uptake system was $\pm$1.4%(<$\pm$5%) and chi^2=29.7(>16.92), respectively. It showed that the sensitivity of CeraSPECT$^{TM}$ was higher in center slices compared with the edge slices. After correction of nonuniform sensitivities for patient data, it showed better results compare with prior to correction. System planar sensitivity of Varicam gamma camera was 4.39 CPM/MBq. The observed count rate at 20% loss was 102,407 counts/sec (head 1), 113,427 counts/sec (head 2), when input count rate was 81,926 counts/sec (head 1), 90,741 counts/sec (head 2). The spatial resolution without scatter medium were 8.16 mm of FWHM and 14.85 mm of FWTM. The spatial resolution with scatter medium were 8.87 mm of FWHM and 18.87 mm of FWTM. Conclusion: It is necessary to understand the importance of quality control and to perform quality control of nuclear medicine devices.vices.

  • PDF

A study to 3D dose measurement and evaluation for Respiratory Motion in Lung Cancer Stereotactic Body Radiotherapy Treatment (폐암의 정위적체부방사선치료시 호흡 움직임에 따른 3D 선량 측정평가)

  • Choi, Byeong-Geol;Choi, Chang-Heon;Yun, Il-Gyu;Yang, Jin-Seong;Lee, Dong-Myeong;Park, Ju-Mi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.59-67
    • /
    • 2014
  • Purpose : This study aims to evaluate 3D dosimetric impact for MIP image and each phase image in stereotactic body radiotherapy (SBRT) for lung cancer using volumetric modulated arc therapy (VMAT). Materials and Methods : For each of 5 patients with non-small-cell pulmonary tumors, a respiration-correlated four-dimensional computed tomography (4DCT) study was performed. We obtain ten 3D CT images corresponding to phases of a breathing cycle. Treatment plans were generated using MIP CT image and each phases 3D CT. We performed the dose verification of the TPS with use of the Ion chamber and COMPASS. The dose distribution that were 3D reconstructed using MIP CT image compared with dose distribution on the corresponding phase of the 4D CT data. Results : Gamma evaluation was performed to evaluate the accuracy of dose delivery for MIP CT data and 4D CT data of 5 patients. The average percentage of points passing the gamma criteria of 2 mm/2% about 99%. The average Homogeneity Index difference between MIP and each 3D data of patient dose was 0.03~0.04. The average difference between PTV maximum dose was 3.30 cGy, The average different Spinal Coad dose was 3.30 cGy, The average of difference with $V_{20}$, $V_{10}$, $V_5$ of Lung was -0.04%~2.32%. The average Homogeneity Index difference between MIP and each phase 3d data of all patient was -0.03~0.03. The average PTV maximum dose difference was minimum for 10% phase and maximum for 70% phase. The average Spain cord maximum dose difference was minimum for 0% phase and maximum for 50% phase. The average difference of $V_{20}$, $V_{10}$, $V_5$ of Lung show bo certain trend. Conclusion : There is no tendency of dose difference between MIP with 3D CT data of each phase. But there are appreciable difference for specific phase. It is need to study about patient group which has similar tumor location and breathing motion. Then we compare with dose distribution for each phase 3D image data or MIP image data. we will determine appropriate image data for treatment plan.