• Title/Summary/Keyword: 블리스터 측정

Search Result 6, Processing Time 0.022 seconds

Detection of Hydride Blisters in Zirconium Pressure Tubes using Ultrasonic Mode Conversion and Velocity Ratio Method (초음파 모드 변환 및 속도비 방법에 의한 지르코늄 압력관의 수소화물 블리스터 탐지)

  • Cheong, Yong-Moo;Lee, Dong-Hoon;Kim, Young-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.4
    • /
    • pp.334-341
    • /
    • 2003
  • When the pressure tubes(f are in contact with the calandria tube(CT) in the pressurized heavy water reactor(PHWR), the temperature difference between inner and outer wall of W results in a thermal diffusion of hydrogen (deuterium) and hydride blisters are formed on the outer surface of PT. Because the hydride blisters and zirconium matrix are acoustically continuous, it is not easy to distinguish the blisters from the matrix with conventional ultrasonic method. An ultrasonic velocity ratio method was developed to detect small hydride blisters on the zirconium pressure tube. Hydride blisters were grown in the PT specimen using a steady state thermal diffusion device. The flight times of longitudinal echo and reflected shear echo from the outer surface were measured accurately. The velocity ratio of the longitudinal wave to the shear wave was calculated and displayed using contour plot. Compared to the conventional flight time method of longitudinal wave, the velocity ratio method shows superior sensitivity to detect smaller blisters as well as better images for the blister shapes. Detectable limit of the outer shape of the hydride blisters was conservatively estimated as $500{\mu}m$, with the same specifications of ultrasonic transducer used in the actual PHWR pressure tube inspection.

Measurement of Mechanical Properties of a Thermally Evaporated Gold Film Using Blister Test (블리스터 시험법을 이용한 열증착 금박막의 기계적 성질 측정)

  • Moon, Ho-Jeong;Ham, Soon-Sik;Earmme, Yun-Young;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.3
    • /
    • pp.882-890
    • /
    • 1996
  • Mechanical properties, including Young's modulus, residual stress and rupture strength, of a thermally evaporated gold film have been measured form a blister test. In a theoretical study, the priniple of minimum potential energy and that of virtual work have been applied to the pressurized circular membrane problem, and load-deflection relations have been derived for typical membrane deflection mode of spheroidal shape. In an experimental study, circular gold membranes of 4800 A-thickness and 3.5mm diameter were fabricated by the silicon electropolishing technique. Mecahnical properties of the thin gold films were deduced from the load-deflection curves obtained by the blister test, Young's moduli, obtianed from blister test, have been in the range of 45-70 GPa, while those of bulk gold have been in the range of 78-80 GPa. Residual stresses in the evaporated gold films have been measured as 28-110MPa in tension, The rupture strength of the gold film has turned out to be almost equal to that of dental gold alloy (310-380MPa). It has been demonstrated that the present specimen fabrication method and blister test apparatus have been effective for simultaneous measurement of Young's modulus, residual stress and repture strength of thin solid films. Especially, the electropolishing technique employed here has provided a simple and practical way to fabricate thin membranes in a circular or an arbitrary shape, which could not be obtained by the conventional anisotropic silicon mecromachining technique.

Measurements of Adhesion Strength Using Scratch Test (스크래치 시험을 통한 접합력 측정)

  • Lee, Chang-Myeon;Heo, Jin-Yeong;Lee, Hong-Gi
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.354-354
    • /
    • 2015
  • 코팅 층과 소지 사이의 접합력 평가를 위하여 박리 시험법(Peel Off Test), 블리스터 시험법(Blister Test), 압입균열 시험법(Indentation Test), 직접 인장 시험법(Direct Full Off Test), 스카치 테이프 시험법(Scotch Tape Test), 그리고 스크래치 시험법(Scratch Test) 등이 사용되어 왔다. 이 중 박리 시험법과 스카치 테이프 시험법이 산업계에서 일반적으로 사용되고 있다. 전자 산업계에서 많이 사용되고 있는 박리시험법은 금속박막과 절연체 기판 사이의 접합력을 간단하게 측정할 수 있으며, 실험값의 재현성이 뛰어난 장점이 있다. 또한, 측정하는 동안 만들어지는 박리 곡선(Peel Curve)로부터 분석의 신뢰성 여부를 확인할 수 있다. 이러한 장점에도 불구하고 박리 시험법 특성 상 금속 코팅층의 강도가 금속 피막/기판간 접합 강도를 초과하여야 하기 때문에 수백 nm 이하의 박막의 접합력 측정에는 적용하기가 어렵다. 이에 반하여, 스카치 테이프 분석법은 일정길이의 접착 테이프를 박막 표면에 붙인 후 다시 떼어내면서 접착력을 평가하는 방법으로, 박막의 접합력 평가에 적용이 가능하다. 그러나 이 방법은 합격 불합격 여부를 판정하는 정성적인 방법으로 정량평가가 어렵다. 또한, 박막에 접착 테이프를 붙일때의 압력, 테이프를 박리할 때의 각도 및 속도를 일정하게 제어하기가 쉽지 않아 결과의 신뢰성이 높지 않다. 스크래치 테스트는 탐사침(Stylus)을 이용하여 박막의 표면에 하중을 증가시키면서 기판을 이동하여, 피막의 균열이나 박리될 때의 임계 하중값 (Critical Load; Lc)을 측정하는 방법이다. 이 방법은 시편 준비가 쉽고 간단하여 빠른 분석이 가능하고, 수백 nm 이하의 박막에도 적용 가능하다. 또한, 접합력을 정량화 할 수 있기 때문에 변수에 따른 접합력 비교가 용이하다는 장점이 있다. 이와 같은 분석적 장점에도 불구하고, 스크래치 시험을 통한 접합력 측정 방법은 아직까진 산업적으로 널리 활용되지 못하고 있다. 따라서, 본 연구에서는 스크래치 테스트의 원리 및 이론에 대하여 간략히 알아보고, 스크래치 분석을 이용한 접합력 비교에 대한 실제 사례들을 소개하고자 하였다.

  • PDF

Design, Fabrication and tTsting of a Microswitch Using Snap-through Buckling Phenomenon (스냅스루 좌굴을 이용한 미소스위치의 설계, 제작 및 실험)

  • Go, Jeung-Sang;Cho, Young-Ho;Kwak, Byung-Man;Park, Kwan-Hum
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.2
    • /
    • pp.481-487
    • /
    • 1996
  • A snapping-beam microswitch has been designed, fabricated and tested. From a design analysis, necessary and sufficient conditions for a snap-through switching fouction have been derived for a clamped shallow beam. The necessary condition has resulted in a geometric relation, in which the ratio of beam thickness to initial beam deflection plays a key role in the snapping ability. The sufficient condition for the snapping action has been obtained as a function of the inertia force due to applied acceleration, and the electrostatic force, adjustable by an inter-electrode voltage. For experimental investigations, a set of microbeams of silicon dioxide/$P^+$silicon bimorphs have been fabricated. Geometric size and mechanical behavior of each material film have been measured from on-chip test structures. Estimated and measured characteristics of the fabricated devices are compared.

A Study of The Effect of Corrosion on Heat Transfer in a Heat Exchanger (열교환기에서 부식이 열전달에 미치는 영향에 관한 연구)

  • Kwon, Hyun-Min;Kwon, Jeong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.227-232
    • /
    • 2019
  • Heat pump systems based on ocean thermal energy conversion (OTEC) systems use the temperature difference between deep ocean water and surface ocean water to operate. However, they may have heat transfer degradation due to corrosion on the heat exchanger surface due to the salinity of sea water. This study presents experimental results for the heat transfer decrease of corroded metal tubes with respect to corrosion time. In order to replace high-priced titanium, electro-deposition (ED) coating was performed on aluminum tubes. Aluminum tubes with ED coating thicknesses of 10, 15, and $20{\mu}m$ were tested for double-tube heat exchangers after performing accelerated corrosion for 6, 12, and 18 weeks. The effects of the coating thickness and the corrosion time on the heat transfer degradation were investigated. From the results, the aluminum tube with an ED coating of $20{\mu}m$ thickness can be suggested as a candidate for replacing titanium tubes.

Evaluation of Deterioration of Epoxy Primer for Steel Bridge Coating using Image Processing and Electrochemical Impedance Spectroscopy (화상처리 기법과 전기화학적 임피던스 분광법을 이용한 강교 도장용 에폭시 하도 도료의 열화 평가)

  • Lee, Chan Young;Lee, Sang Hun;Park, Jin Hwan
    • Corrosion Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.53-61
    • /
    • 2009
  • In this study, both evaluations by visual imaging for exterior view of coating and by EIS were executed for epoxy primer coated specimens deteriorated by accelerated test, and comparison and analysis were carried out for 2 evaluation methods. In the comparison between total damaged area ratio acquired by image processing method and deterioration point, higher deterioration points were appeared for rusted specimens than for non-rusted specimens. It is attributed that deterioration point per unit area ratio given for rust is higher than for peeling. In the comparison between total damaged area ratio and EIS result, impedance of coating was largely decreased as about TEX>$10^4{\Omega}{\cdot}cm^2$ or less when rust area ratio is more than about 0.1%, and blistering area ratio is more than about 3%. Charge transfer resistance ($R_{ct}$) and double layer capacitance ($C_{dl}$) values were appeared for all specimens except 2 ones, which shows that water is accumulated and steel substrate is corroded at coated film-steel interface. In the comparison between deterioration point and EIS result, more than 10 points as deterioration point were given for specimens of below $10^6{\Omega}{\cdot}cm^2$ of impedance at low frequency. For specimens deteriorated by NORSOK cyclic test, impedance was lowest of all, though deterioration point was not high. It is thought to be attributed that coating system and accelerated deterioration condition of cyclic tested specimens were different from those of main specimens. From the result, it is thought that coating resistance can be relatively more decreased than deterioration degree estimated from exterior view under more severe corrosion environment or in the present of more complex deterioration factors.