• Title/Summary/Keyword: 블록 표면 계수

Search Result 10, Processing Time 0.026 seconds

Robust 3D Hashing Algorithm Using Key-dependent Block Surface Coefficient (키 기반 블록 표면 계수를 이용한 강인한 3D 모델 해싱)

  • Lee, Suk-Hwan;Kwon, Ki-Ryong
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.47 no.1
    • /
    • pp.1-14
    • /
    • 2010
  • With the rapid growth of 3D content industry fields, 3D content-based hashing (or hash function) has been required to apply to authentication, trust and retrieval of 3D content. A content hash can be a random variable for compact representation of content. But 3D content-based hashing has been not researched yet, compared with 2D content-based hashing such as image and video. This paper develops a robust 3D content-based hashing based on key-dependent 3D surface feature. The proposed hashing uses the block surface coefficient using shape coordinate of 3D SSD and curvedness for 3D surface feature and generates a binary hash by a permutation key and a random key. Experimental results verified that the proposed hashing has the robustness against geometry and topology attacks and has the uniqueness of hash in each model and key.

Evaluation of Absorbent-Pervious Alkali-Activated Block Using Recycled Aggregate (순환골재를 이용한 보투수성 알칼리 결합재 블록의 성능평가)

  • Park, Kwang-Min;Kim, Hyung-Suk;Cho, Young-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.2
    • /
    • pp.160-167
    • /
    • 2017
  • The purpose of this study is to identify the possibility of developing the 100% Recycled-resources Absorbent-Pervious Alkali-activated Blocks using both the alkalli-binder and the recycled aggregate. In addition, It established a test method such as Void ratio, compressive strength, coefficient permeability, absorption, and evaporation. As a result, an alkali-activated using recycled aggregate block was able to manufacture an 24 MPa class absorbent-pervious blocks with a liquid type sodium silicate and early high temperature curing. In this case, water-holding capacity, absorption and relative absorption were more effective than the natural aggregates. In conclusion, Absorbent-pervious alkali-activated Block Using recycled aggregate has a surface temperature reducing effect of approximately 10 % compared to ordinary concrete block.

A Study on the Development of Stability Evaluation Technique for Bed Material Using High Speed Flow Measurement Instruments (고유속 조건에서 하상재료의 안정성 평가 기법 개발에 관한 연구)

  • Jung, Dong Gyu;Kim, Kwang Soo;Kim, Young Do;Park, Jae Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.79-79
    • /
    • 2018
  • 하천시설물 설계, 시공 및 관리에 재료에 따른 호안이나 제방의 보호능력이 저하되어 설계 시 예상하지 못한 조건에서 쉽게 파손될 수 있으며, 하천환경의 변화를 야기시킬 수 있다. 제방 표면재료는 제외 비탈면의 침식 방지를 목적으로 사용되는 재료로 주로 호안블록. 식생 매트, 사석, 돌망태, 식생등이 주로 사용되며 국내에서는 2000년대 이전에는 자연 흙사면의 식생, 돌망태, 단순 돌기형 콘크리트 블록 등이 주로 사용되었으며 2000년대 이후에는 하천환경을 고려하여 식생의 생장이 가능한 친환경 호안 블록 및 식생 매트의 적용이 일반적인 실정이다. 제방의 수리적 설계를 위해서는 표면 재료의 수리 특성, 즉, 조도계수 및 한계 유속, 한계 소류력이 제시되어야 하는데 이는 실험을 통해서 결정되어야 한다. 때문에 본 연구에서는 자연형 하상재료를 이용하여 바이오 폴리머 첨가시 증가하는 방어능력에 대한 향상도를 평가하는 실험적 평가 방법을 제안하기위해 홍수시 수리조건을 반영하여 상류에서부터 사류까지 다양한 유속범위에 따른 세굴 및 침식에 대한 실험을 진행하였다. 본 연구에서는 실험연구를 통해 연구에 사용된 재료 외 추가적인 재료에 대해서도 평가방법이 적용될 수 있도록 제방 재료의 안정성 평가시스템을 개발하였고, 안정성 평가를 위한 실험진행은 기 개발된 바닥응력을 직접측정하는 장치와 PIV시스템을 이용하여 수리특성을 측정하였다.(Park J.H. et al. 2016, Flow Measurment and instrumentation.) 이러한 측정 장치를 이용하여 바이오폴리머의 첨가에 유무에 따라 세굴에 대한 방어능력의 향상정도를 측정하고자 세굴 및 침식에 대한 평가 방법을 제시하고 있다.

  • PDF

A Study on the erosion of new eco-materials by soil loss rate in slope channel (경사수로에서 토양유실율을 통한 친환경 신소재의 침식에 관한 연구)

  • Jung, Dong Gyu;Kim, Kwang Soo;Kim, Young Do;Park, Yong Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.85-85
    • /
    • 2019
  • 하천시설물 설계, 시공 및 관리에 있어서 구성재료의 보호능력에 따라 예상하지 못한 조건에서 쉽게 파손될 수 있다. 이러한 영향은 하천환경의 변화를 야기시킬 수 있다. 제방 표면 재료는 제외 비탈면의 침식 방지를 목적으로 사용되는 재료로 주로 호안블록. 식생 매트, 사석, 돌망태, 식생등이 주로 사용되고 있다. 국내에서는 2000년대 이전에는 자연 흙사면의 식생, 돌망태, 단순 돌기형 콘크리트 블록 등이 주로 사용되었으며 2000년대 이후에는 하천환경을 고려하여 식생의 생장이 가능한 친환경 호안 블록 및 식생 매트의 적용이 일반적으로 시공되고 있다. 제방의 수리적 설계를 위해서는 재료 표면의 수리 특성, 즉, 조도계수 및 한계 유속, 한계 소류력이 제시되어야 하는데 이는 실험을 통해서 결정되어야 한다. 때문에 본 연구에서는 자연형 하상재료를 이용하여 바이오 폴리머 첨가시 증가하는 방어능력에 대한 향상도를 평가하는 실험적 평가 방법을 제안하기위해 홍수시 수리조건을 반영하여 상류에서부터 사류까지 다양한 유속범위에 따른 세굴 및 침식에 대한 실험을 진행하였다. 본 연구에서는 자연하천과 유사한 조건의 경사를 가지는 경사수로에서 실험연구를 통해 제방재료의 안정성 평가방법을 개발하였고, 안정성 평가를 위한 실험진행은 기 개발된 바닥응력을 직접측정하는 장치와 PIV시스템을 이용하여 수리특성을 측정하였다.(Park J.H. et al. 2016, Flow Measurment and instrumentation.) 기존 문헌에서 제시되었던 측정 장치를 이용하여 바이오폴리머의 첨가에 유무에 따라 세굴에 대한 방어능력의 향상정도를 측정하고자 세굴 및 침식에 대한 평가 방법을 제시하고 있다.

  • PDF

Design of a Microwave Bias-Tee Using Lumped Elements with a Wideband Characteristic for a High Power Amplifier (광대역 특성을 갖는 집중 소자를 이용한 고출력 증폭기용 마이크로파 바이어스-티의 설계)

  • Oh, Hyun-Seok;Jeong, Hae-Chang;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.7
    • /
    • pp.683-693
    • /
    • 2011
  • In this paper, a design of high current and broad-band microwave bias-tee was presented for a stable bias of a high power amplifier. An input impedance of bias-tee should be shown to 50 ohm with the wideband in order to be stably-biased the amplifier. For this design of the bias-tee, a capacitor of bias-tee for a DC block was designed with a high wide-band admittance by a parallel sum of capacitors, and a inductor for a RF choke and a DC feeding was designed with a high wide-band impedance by a series sum of inductors. As this inductor and capacitor for the sum has each SRF, band-limitation of lumped element was driven from SRF. This limitation was overcome by control of a resonance's quality factor with adding a resistor. 1608 SMD chips for design's element was mounted on the this pattern for the designed bias-tee. The fabricated bias-tee presented 10 dB of return loss and wide-band about 50 ohm input impedance at 10 MHz~10 GHz.

Annual Transfer of $^{90}Sr$ to Rice from Paddy Soils Collected around Yonggwang and Ulchin Nuclear Power Plants (영광 및 울진 원전 주변 논 토양으로부터 벼로의 년차별 $^{90}Sr$ 전이)

  • Lim, Kwang-Muk;Choi, Yong-Ho;Park, Hyo-Guk;Kang, Hee-Suk;Choi, Heui-Joo;Lee, Han-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.4
    • /
    • pp.271-279
    • /
    • 2003
  • Soil blocks were taken into culture boxes from 12 paddy fields within 5 km radii of Yonggwang and Ulchin NPPs and $^{90}Sr$ was applied to the surface water at a pre-transplanting stage and $1{\sim}2$ days before the start of heading. Following the pre-transplanting application, transfer factors were investigated for $2{\sim}4$ years. In the year of application, transfer factors $(m^2\;kg^{-1}-dry)\;of\;^{90}Sr$ applied before transplanting, showing no regionally distinguishable trend, varied with soils by a factor of about 2 with averages of $2.6{\times}10^{-4}$ for hulled seeds and $1.3{\times}10^{-2}$ for straw Transfer factors of $^{90}Sr$ applied shortly before heading were about 2 times greater than those applied before transplanting. Transfer factors tended to decrease with increasing soil pH and exchangeable Ca. Generic values of $^{90}Sr$ transfer factors in the year of deposition were proposed for the Korean paddy fields. In the second year compared with the first year, the transfer factor decreased more in Ulchin soils, which were on the whole higher in sand content, than in Yonggwang soils. For Yonggwang soils as a whole, the annual decrease in transfer factor was well described by an exponential equation with a half-life of about 2.2 years.

Estimate of Wave Overtopping Rate on Armoured Slope Structures Using FUNWAVE-TVD Model (FUNWAVE-TVD 모델을 이용한 경사구조물의 월파량 산정)

  • Moon Su Kwak
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.36 no.1
    • /
    • pp.11-19
    • /
    • 2024
  • In this study, the program was modified by adding the empirical formula of EurOtop (2018) to enable calculation of wave overtopping on armoured slope structures in the FUNWAVE-TVD model using the fully nonlinear Boussinesq equation. The validity of the modified numerical model was verified by comparing it with CLASH data and experiment data for the rubble mound structure. This model accurately reproduced the change in wave overtopping rate according to the difference in the roughness factor of the armoured block, and well reproduced the rate of decrease in wave overtopping rate due to the increase in relative freeboard. The overtopping rate of the armoured slope structures showed significant differences depending on the positioning condition of the armoured blocks. When Tetrapods were placed with regular positioning, the overtopping rate increased significantly compared to when they were placed with random positioning, and it was consistent with when they were placed with Rocks. Meanwhile, when rocks were placed in one row, the wave overtopping rate was greater than when rocks were placed in two rows, which is believed to be due to the influence of the roughness and permeability of the structure's surface.

Surface Image Analysis for Evaluating Porosity and Permeability Coefficient of Permeable Concrete Block (투수 콘크리트 블록 공극률 및 투수계수 평가를 위한 표면 이미지 분석 기법 개발)

  • Jo, Sangbeom;Son, Younghwan;Kim, Donggeun;Jeon, Jihun;Kim, Taejin
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.2
    • /
    • pp.47-57
    • /
    • 2023
  • The increase of impermeable area ratio is causing hydrologic cycle problems in urban areas and groundwater depletion in rural areas, permeable pavements are getting attention to expand permeable areas. The performance of the permeable concrete block pavement, which is part of the permeable pavement, is greatly affected by the porosity. In addition, the permeability coefficient is a major factor when designing permeable concrete block pavement. Existing porosity and permeability test methods have problems such as uneconomical or poor field applicability. The object of this study was to develop a methodology for evaluating porosity and permeability coefficient using a surface image of a permeable concrete block. Specimens are manufactured with various porosity ranges and porosity and permeability tests are performed. After surface image preprocessing, normalization and binarization methods were compared. Through this, the method with the highest correlation with the lab test result was determined. From the results, the PDR (pore determined ratio) was obtained. Simple linear regression analysis is performed with PDR and lab test results. The results showed a high correlation of R2 more than 0.8, and the errors were also low.

Evaluation of Material Properties of Concrete Harbour Facilities Using Nondestructive Testing Methods (비파괴시험에 의한 콘크리트 항만시설물의 주요 물성치 평가)

  • Yi, Jin-Hak;Han, Sang-Hun;Park, Woo-Sun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.23 no.1
    • /
    • pp.1-10
    • /
    • 2011
  • Recently harbor remodeling projects are seriously considered to enhance the loading and unloading capability of old container terminals and to make decrepit ports as eco-friendly harbor and waterfront spaces in many countries. In such a case, quantitative and qualitative evaluations on concrete harbor facilities are mandatory to determine the current structural integrity condition of aged materials. Once the remodeling project is determined to be carried out, the reusability of individual structural members and facilities including caissons, cell-blocks, and tetra-pods need to be decided based on the simple and economic visual inspection and/or nondestructive testing. In this study, the systematic quantitative evaluation procedure for determining the structural integrity condition and the reusability is studied based the nondestructive testing and evaluation methods. Conventional methods including Schmidt hammer test and ultrasonicpulse velocity methods and elastic wave based methods including impact echo test and surface wave test are applied to the old harbor facilities in five different sites. The compressive tests are also carried out to determine the elastic modulus and compressive strength of concrete materials.

Optimization and Development of Prediction Model on the Removal Condition of Livestock Wastewater using a Response Surface Method in the Photo-Fenton Oxidation Process (Photo-Fenton 산화공정에서 반응표면분석법을 이용한 축산폐수의 COD 처리조건 최적화 및 예측식 수립)

  • Cho, Il-Hyoung;Chang, Soon-Woong;Lee, Si-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.6
    • /
    • pp.642-652
    • /
    • 2008
  • The aim of our research was to apply experimental design methodology in the optimization condition of Photo-Fenton oxidation of the residual livestock wastewater after the coagulation process. The reactions of Photo-Fenton oxidation were mathematically described as a function of parameters amount of Fe(II)($x_1$), $H_2O_2(x_2)$ and pH($x_3$) being modeled by the use of the Box-Behnken method, which was used for fitting 2nd order response surface models and was alternative to central composite designs. The application of RSM using the Box-Behnken method yielded the following regression equation, which is an empirical relationship between the removal(%) of livestock wastewater and test variables in coded unit: Y = 79.3 + 15.61x$_1$ - 7.31x$_2$ - 4.26x$_3$ - 18x$_1{^2}$ - 10x$_2{^2}$ - 11.9x$_3{^2}$ + 2.49x$_1$x$_2$ - 4.4x$_2$x$_3$ - 1.65x$_1$x$_3$. The model predicted also agreed with the experimentally observed result(R$^2$ = 0.96) The results show that the response of treatment removal(%) in Photo-Fenton oxidation of livestock wastewater were significantly affected by the synergistic effect of linear terms(Fe(II)($x_1$), $H_2O_2(x_2)$, pH(x$_3$)), whereas Fe(II) $\times$ Fe(II)(x$_1{^2}$), $H_2O_2$ $\times$ $H_2O_2$(x$_2{^2}$) and pH $\times$ pH(x$_3{^2}$) on the quadratic terms were significantly affected by the antagonistic effect. $H_2O_2$ $\times$ pH(x$_2$x$_3$) had also a antagonistic effect in the cross-product term. The estimated ridge of the expected maximum response and optimal conditions for Y using canonical analysis were 84 $\pm$ 0.95% and (Fe(II)(X$_1$) = 0.0146 mM, $H_2O_2$(X$_2$) = 0.0867 mM and pH(X$_3$) = 4.704, respectively. The optimal ratio of Fe/H$_2O_2$ was also 0.17 at the pH 4.7.