• Title/Summary/Keyword: 브라켓 부착

Search Result 84, Processing Time 0.039 seconds

Adherence of Salivary Proteins to Various Orthodontic Brackets (다양한 교정용 브라켓 표면에 부착하는 타액단백질에 관한 연구)

  • Ahn, Sug-Joon;Ihm, Jong-An;Nahm, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.32 no.6 s.95
    • /
    • pp.443-453
    • /
    • 2002
  • The principal aims of this study were to identify the composition of salivary pellicles formed on various orthodontic brackets and to obtain a detailed information about the protein adsorption profiles from whole saliva and two major glandular salivas. Four different types of orthodontic brackets were used. All were upper bicuspid brackets with a $022{\times}028$ slot Roth prescription; stainless steel metal, monocrystalline sapphire, polycrystalline alumina, and plastic brackets. Bracket pelicles were formed by the incubation of orthodontic brackets with whole saliva, submandibular-sublingual saliva, and parotid saliva for 2 hours. The bracket pellicles were extracted and confirmed by employing sodium dodecyl sulfatepolyacrylamide gel electrophoresis, Western transfer methods, and immunodetection. The results showed that low-molecular weight salivary mucin, ${\alpha}-amylase$, secretory IgA (sIgA), acidic proline-rich proteins, and cystatins were attached to all of these brackets regardless of the bracket types. High-molecular weight mucin, which promotes the adhesion of Streptococcus mutans, did not adhere to uy orthodontic brackets. Though the same components were detected in all bracket pellicles, however, the gel profiles showed qualitatively and quantitatively different pellicles, according to the origins of saliva and the bracket types. In particular, the binding of sIgA was more prominent in the pellicles from parotid saliva and the binding of cystatins was prominent in the pellicles from the form plastic brackets. This study indicates that numerous salivary proteins adhere to the orthodontic brackets and these salivary proteins adhere selectively according to bracket types and the types of the saliva.

Quantitative analysis of mutans streptococci adhesion to various orthodontic bracket materials in vivo (다양한 교정용 브라켓 원재료에 부착하는 mutans streptococci 양의 비교분석)

  • Yu, Jin-Kyoung;Ahn, Sug-Joon;Lee, Shin-Jae;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.39 no.2
    • /
    • pp.105-111
    • /
    • 2009
  • Objective: To estimate the effects of bracket material type on enamel decalcification during orthodontic treatment, this study analyzed the adhesion level of mutans streptococci (MS) to orthodontic bracket materials in vivo. Methods: Three different types of orthodontic bracket materials were used: stainless steel, monocrystalline sapphire, and polycrystalline alumina. A balanced complete block design was used to exclude the effect of positional variation of bracket materials in the oral cavity. Three types of plastic individual trays were made and one subject placed the tray in the mouth for 12 hours. Then, the attached bacteria were isolated and incubated on a mitis salivarius media containing bacitracin for 48 hours. Finally, the number of colony forming units of MS was counted. The experiments were independently performed 5 times with each of the 3 trays, resulting in a total of 15 times. Mixed model ANOVA was used to compare the adhesion amount of MS. Results: There was no difference in colony forming units among the bracket materials irrespective of jaw and tooth position. Conclusions: This study suggested that the result of quantitative analysis of MS adhesion to various orthodontic bracket materials in vivo may differ from that of the condition in vitro.

Three-dimensional finite element analysis of the bracket positioning plane in lingual orthodontics (설측 브라켓 부착을 위한 기준평면 설정에 관한 3차원 유한요소법적 연구)

  • Kim, Sun-Hwa;Park, Soo-Byung;Yang, Hoon-Chul
    • The korean journal of orthodontics
    • /
    • v.36 no.1 s.114
    • /
    • pp.30-44
    • /
    • 2006
  • This study was performed to investigate the location of the ideal bracket positioning plane in lingual orthodontics using the three-dimensional finite element method. Displacement of the anterior teeth were evaluated according to the vertical and the angular movements of the bracket positioning plane. To achieve the ideal movement of anterior teeth in the lingual central plane, the location of the force application point and the amount of the moment applied to the four incisors were evaluated. As the bracket positioning plane was moved parallel toward the incisal edge, uncontrolled tipping and extrusion of the maxillary and the mandibular incisors were increased. But lingual tipping of the crown was decreased in the maxillary and the mandibular canines. As the bracket positioning plane was inclined toward the incisal edge, lingual tipping was increased in the 6 anterior teeth and extrusion of incisors and intrusion of the canine was also increased. As the retraction hook of the canine bracket was elongated, lingual tipping and extrusion of the central incisor and mesial movement and extrusion of the lateral incisor were increased. In the canine, mesial and labial movements of the crown were increased. When the moment was applied to the 4 incisors of the maxillary and the mandibular arch in the lingual central plane, 280 gf-mm in the maxillary central incisor, 500 gf-mm in the maxillary lateral incisor, 170 gf-mm in the mandibular central incisor and 370 gf-mm in the mandibular lateral incisor produced bodily movement of the individual tooth.

SHEAR BOND STRENGTH AND FAILURE PATTERNS ACCORDING TO THE THICKNESS OF RESIN BASE IN BRACKET BONDING (브라켓 부착시 레진 베이스의 두께에 따른 전단결합강도와 파절양상에 관한 연구)

  • Kim, Jae-Hyuk;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.28 no.4 s.69
    • /
    • pp.659-668
    • /
    • 1998
  • The purpose of this study was to evaluate the possibility of the decrease of bond strength due to increased thickness of resin base in indirect bracket bonding technique. Metal brackets were bonded to the resin blocks involving bovine lower incisors and the thickness of resin bases was increased by increments of 0.5 mm from 0.0 mm to 2.0 mm. They were divided into two groups, one group is that the thickness of resin base was increased but the loading point from the tooth surface was maintained constantly, the other group is that the loading point from the tooth surface and the resin base thickness were increased concomitantly. The shear bond strength was tested on universal testing machine and the failure patterns were assessed with the adhesive remnant index(ARI). The results were as follows: 1. When the distance from the tooth surface to the loading point was maintained constantly, shear bond strength was increased significantly according to the decrease of distance from the bracket base to the loading point and the increase of resin base thickness. 2. When the distance from the tooth surface to the loading point and the resin base thickness were increased concomitantly, shear bond strength was decreased according to the increase of resin base thickness but significant differences were ignorable. 3. There were no significant differences in ARI scores according to the change in the thickness of resin base. The results of the present study indicated that shear bond strength was not much affected by the thickness of resin base, whereas was decreased according to the increase of distance from bracket base to the loading point.

  • PDF

Tooth color changes associated with the bracket bonding and debonding (교정치료 시 브라켓 부착 및 제거에 따른 치아색 변화)

  • Kim, Seok-Pil;Hwang, In-Nam;Cho, Jin-Hyoung;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.36 no.2 s.115
    • /
    • pp.114-124
    • /
    • 2006
  • The purpose of this study was to evaluate the tooth color changes of resin bonding sites and their adjacent sites on orthodontic bracket bonding. Sixty extracted sound premolars were used and the tooth color was recorded according to the CIE $L^*a^*b^*$ color system using a spectrophotometer. The tooth colors of the twenty premolars were measured and compared before bracket bonding and after removal. On a further twenty premolars, the tooth color was measured before and after only primer application. In the change of $L^*$ values, according to the bracket bonding and primer application, the lightness was decreased, and in the change of $a^*\;and\;b^*$ values, the color was changed into a more yellowish color The color differences $({\Delta}E^*)$ were calculated from the $L^*a^*b^*$ values and compared with the standard value of clinical detection $({\Delta}E^*=3.7)$. The color differences between before the bracket bonding and after removal noted exceeded the standard value and those of between before and after the primer application were not larger than the standard value. Toothbrushing was performed after application of the primer to evaluate the color changes according to the primer abrasion. As a control, toothbrushing was performed on the last twenty premolars. The color differences noted were larger than the standard value after toothbrushing. Also, to evaluate the color changes of the tooth which is exposed to sun irradiation after bracket removal, additional photoaging was performed and the color was measured for all teeth. The additional color differences after photoaging were smaller than the standard value. The above results suggest that the tooth color changes after fixed orthodontic treatment.

A Scanning electron microscopic study of enamel surface by debracketing of ceramic bracket (도재브라켓의 제거방법에 따른 법랑질표면의 주사전자현미경학적 관찰)

  • Park, Mi-Suk;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.26 no.5 s.58
    • /
    • pp.613-622
    • /
    • 1996
  • The purposes of this study were to evaluate and compare the frequency of ceramic bracket fracture, frequency of enamel fracture, bond fracture site, adhesive remnant index after mechanical and electrothermal debracketing, to evaluate effectiveness of high and low speed rotary instrument and ultrasonic instrument during residual adhesive remnants removal, and to measure resin film surface(percentage) using by image analyser(Leco 300). Bond fracture site, bracket fracture, and enamel surface damage were examined by scanning electron microscope. The following results were obained : 1. In the mechanical debracketing group, the bond failed predominantly at enamel-adhesive interface with the bulk of adhesive remaining on bracket base. 2. In the eletrothermal debracketing group, the bond failed predominantly at adhesive-bracket interface with the bulk of adhesive remaining on enamel surface. 3. The most effectiveness of residual resin removal was obtained by means of the resin polishing bur and the order of scratch formation was the procedure using tungsten carbide bur, ultrasonic scaler, sof-lex disc, and polishing bur. 4. The order of the resin film surface percentage was ultrasonic scaler, tungsten carbide bur, sof-lex disc, and resin polishing bur.

  • PDF

THE POSITIONING ERRORS IN BONDING LINGUAL BRACKETS (설측브라켓 부착시 위치오차에 관한 연구)

  • Choi, Joon-Kyu;Hwang, Hyeon-Shik;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.99-111
    • /
    • 1998
  • The purpose of this study was to evaluate the positioning errors according to the method of bonding lingual brackets. Dental models of twenty orthodontic patients with malocclusion were selected for this study. The positioning errors were measured on each model that brackets were bonded to. Three different bonding methods were used. For the first method the bracket was bonded intimately to the lingual surface of the model. For the second method, the bracket was bonded intimately to the lingual surface after setting up using articulator. The passive bracketing, bonding the bracket ligated first to ideal archwire, was used after setting up as the last method. The results were as follows: 1. The brackets bonded without setting up showed greater angulation errors in the upper 1st premolar and the lower canine than those in other bonding methods. The brackets bonded without passive bracketing showed greater positioning errors in upper central incisor, lower 1st and End premolars. 2. The brackets bonded without setting up showed greater torque error in lower 2nd premolar than those in other bonding methods. The brackets bonded without passive bracketing showed greater torque errors in all upper teeth, lower 1st and 2nd premolars. 3. The brackets bonded without passive bracketing showed greater rotation errors between upper central incisors, lower central incisors, lower lateral and central incisor, lower canine and lateral incisor. 4. The brackets bonded without setting up showed greater in-out errors between upper canine and lateral incisor than those in other bonding methods. The brackets bonded without passive bracketing showed greater in-out errors between upper central incisors, upper central and lateral incisors, upper 1st and 2nd premolars, lower lateral and central incisors, lower canine and lateral incisor. These results suggest that there is a large amount of positioning error in lingual brackets even by an indirect bonding technique, and it may be reduced by passive bracketing.

  • PDF

Change of shear bond strength of orthodontic brackets according to surface treatment on dental gold alloy (치과용 금합금의 표면처리에 따른 교정용 브라켓의 전단결합강도 변화)

  • Min, Ji-Hyun;Hwang, Hyeon-Shik;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.30 no.4 s.81
    • /
    • pp.483-490
    • /
    • 2000
  • The dental gold alloy shows a lower bond strength than the natural teeth in bracket bonding, and this can be a possible source of subsequent bond failure. This study aims to evaluate the effect of various gold alloy surface treatment techniques on shear bond strength between the orthodontic adhesives and the gold alloy and to find ways of increasing the bond strength. Two hundred and forty specimens made of the dental fold alloy were divided into twelve groups based on the combination of surface treatment methods(non-surface treatment, sandblasted, sandblasted plus tin-plated, and sandblasted plus intermediate adhesive) and adhesive systems (Ortho-one, Panavia 21, Superbond C&B). The specimens with bonded brackets were placed in distilled water at $37^{\circ}C$ for 24 hours and shear bond strength was measured by a universal testing machine. The results were as follows: 1. All surface-treated groups showed a significantly higher shear bond strength than non-surface-treated groups. 2. The sandblasted plus tin-plated group showed a significantly higher shear bond strength than the sandblasted group only when Panavia 21 was involved. 3. The sandblasted plus intermediate adhesive group showed a significantly higher shear bond strength than sandblasted group regardless of the type of adhesive used. 4. Of the three resin adhesive types, the Superbond C&B showed the highest bond strength, followed by Panavia 21 and Ortho-one. These findings suggest that a combination of sandblasting and intermediate resin treatment is desirable in order to enhance bracket bond strength regardless of adhesive types.

  • PDF

Direct detection of cariogenic streptococci in metal brackets in vivo using polymerase chain reaction (교정용 메탈 브라켓에서 자가중합효소연쇄반응을 통한 치아우식증 원인균의 탈출)

  • Ahn, Sug-Joon;Lee, Shin-Jae;Baek, Seung-Hak;Kim, Tae-Woo;Chang, Young-Il;Nam, Dong-Seok;Lim, Bum-Soon
    • The korean journal of orthodontics
    • /
    • v.35 no.4 s.111
    • /
    • pp.312-319
    • /
    • 2005
  • Streptococcus mutans and Streptococcus sobrinus are major etiological agents in enamel demineralization around orthodontic appliances. This study was designed to examine the prevalence of these streptococci on orthodontic brackets in vivo using polymerase chain reaction. Four incisor brackets in the upper and lower arches were removed and collected from 80 patients at the time of debonding. The genomic DMA of adhered bacteria was extracted and each dextranase gene of S. mutans and S. sobrinus was amplified using the specific oligonucleotide primers. The results showed that the maxillary incisor brackets were colonized by both cariogenic streptococci to a somewhat higher degree than that taken from the mandible. The prevalence of S. mutans was $50.0\%$ on the maxillary incisor brackets and $33.8\%$ on the mandibular incisor brackets, and that of S. sobrinus was $17.5\%$ and $15.0\%$, respectively. Both species were detected on the maxillary incisor brackets of 7 patients $(8.8\%)$ and the mandibular incisor brackets of 5 patients $(6.3\%)$. These results suggest that cariogenic streptococci can adhere to the incisor brackets and may be resident species on the incisor brackets.

The Effect of Surface Treat`ment on Bond Strength of Polycarbonate Bracket (폴리카보네이트 브라켓 부착 시 결합강도 증진을 위한 표면처리 효과)

  • Kim, Seok-Pil;Kim, Nyeon-Kyeong;Lee, Hyun-Jung;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.36 no.5
    • /
    • pp.331-338
    • /
    • 2006
  • Objective: The purpose of this study was to evaluate whether the bond strength of polycarbonate brackets can be increased through surface treatment. Methods: One hundred polycarbonate brackets (Alice) were bonded to bovine incisors with light-cured adhesive. The bracket bases were treated with one of three methods; sandblasting, plastic conditioner application, and combined treatment with sandblasting and plastic conditioner. The brackets without any suraace treatment served as the control. The shear bond strength was tested with a universal testing machine, and failure pattern was assessed with the adhesive remnant index. Results: The shear bond strength in all experimental groups was higher than that of the control group (p < 0.001). The group treated with plastic conditioner after sandblasting showed statistically higher shear bond strength than the sandblasting only group to (p < 0.05). The group treated with plastic conditioner after sandblasting showed higher shear bond strength than plastic conditioner only group, but the difference was not statistically significant. Conclusion: The above results suggest that the surface treatments of polycarbonate bracket is mandatory to improve bond strength, and the most effective method is an application of plastic conditioner after sandblasting.