건물에너지성능 및 불쾌현휘를 고려한 고정형 블라인드의 최적 슬랫각도 도출 방법에 관한 연구 (A Elicitation Method of Optimum Slat Angle of Fixed Venetian Blind Considering Energy Performance and Discomfort Glare in Buildings)

  • 박장우;윤종호;오명환;이광호
    • KIEAE Journal
    • /
    • 제12권6호
    • /
    • pp.107-112
    • /
    • 2012
  • The purpose of this study is to determine the optimum slat angle of the venetian blind which was applied at an outer skin of a curtain-wall system. The evaluation of the blind slat angle was performed in terms of the comfortable visual environment and decreased energy consumption. The office building prototype was considered for the analysis and simulation variables include application of blind, blind slat angle and dimming control of lighting. The annual energy consumption and incidence rate of discomfort glare were analyzed using EnergyPlus which is developed by the U. S. Department of Energy for the detailed building energy simulation. As a result, it turns out that when the blind (reflectance: 0.5) was installed, the annual energy consumption was greater than that of the base model. However, when the dimming control was applied, the maximum energy saving of 16.3% could be achieved at a slat angle of $0^{\circ}$. In addition, in case of the base model, the incidence rate of discomfort glare was 84%, while the case of the blind with the slat angle of $0^{\circ}$ showed that the incidence rate of discomfort glare was 42.4%. Consequently, the results showed that the slat angle of $55^{\circ}$ with dimming control was the optimum strategy for the comfortable visual environment and decreased energy consumption.

재실자의 시쾌적과 건물에너지성능을 고려한 슬랫형 블라인드 자동제어전략 (Optimum Automated Control Strategies of Inside Slat-type Blind considering Visual Comport and Building Energy Performance)

  • 오명환;윤종호;신우철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.187-195
    • /
    • 2011
  • Glass Envelope is vulnerable to insulation performance and controling solar radiation. Insulation performance is consistently improving these days due to recent building energy saving policy in South Korea. However, solar control at glass envelope is still limited to meeting requirements of ideal high performance. Generally, Inside Blind plays an important role of solar control instead of glass which have a characteristics of transmitted solar. Unfortunately, most of them are controled by occupants and which method is not resonable in building energy. Therefore, achieving the high efficient performance building, automated control blind system considering reduction of building loads have to be adopted. Furthermore, considering occupants visual comport about removing discomfort glare is also essential.

  • PDF

박물관의 조명 각도와 관람객 눈높이에 따른 불쾌적 현휘 분석 (Analysis of Discomfort Glare by Visitors' Eye-level and Illumination Angles in Museum)

  • 이영웅;김상현;조성은;강유진;김수민
    • 한국가구학회지
    • /
    • 제26권4호
    • /
    • pp.328-333
    • /
    • 2015
  • The museum is a important place to inform the value of various antiquities and relics. The museum, founded in domestic, were increased 90% in 2013 compared to 2006, and total number of including private museums were increased more than three times over the past decade. There are installing a variety of illumination and air-conditioning system, such as the spot lighting of exhibition explanation. But the exhibition explanation should not happen to visual perception disabilities by lighting. According to ICOM (International Council of Museum), it is stipulating that the museum should not to occur glare. However, we confirmed some occurred the glare and it was lack of previous studies about prevention plan. In this study, we verified occurrence of the glare by illumination angles and visitor's eye-level. The luminance values were determined by using DSLR camera and illuminometer. As a result, when illumination angle is 90 degree, the glare did not occurred by the luminance value ratio of over 0.167 regardless of eye-level. By contrast, the angle 30 degree was appeared glare with all level. And this study was compared luminance values that obtained through experiment and surveying.