• Title/Summary/Keyword: 불소제거

Search Result 93, Processing Time 0.021 seconds

Fluoride and nitrate removal in small water treatment plants using electro-coagulation (전기응집을 이용한 소규모 수도시설의 질산성질소와 불소이온 제거)

  • Han, Song-Hee;Chang, In-Soung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.767-775
    • /
    • 2011
  • In this study we verified if the electro-coagulation process can treat properly the nitrate and fluoride that are not removed well in the conventional small water treatment plants which usually employ chlorination and filtration only. As we gave a change of electrode material and gap-distance between electrodes, removal efficiency of the nitrate and fluoride was determined by electro-coagulation process which were equipped with aluminum and stainless steel (SUS304) electrodes. In addition, electrode durability was investigated by determination of electrodes mass change during the repetitive experiments. Removal efficiency was great when aluminum was used as an anode material. Nitrate removals increased as electric density and number of electrodes increased, but fluoride removal was less sensitive to both parameters than nitrate. After 10 minutes of contact time with the current density from $1{\times}10^{-3}$ to $3{\times}10^{-3}A/cm^{2}$, nitrate and fluoride concentration ranged from 9.2 to 1.2mg/L and from 0.02 to 0.01mg/L, which satisfied the regulation limits. Regardless of the repeating number of experiments, removal efficiency of both ions were almost similar and the change of electrode mass ranged within ${\pm}$0.5%, indicating that the loss of the electrode mass is not so much great under the limited circumstances.

물리적 기상증착법을 이용한 내지문(Anti-Finger Print) 코팅 최적 공정 및 박막특성분석

  • Kim, Wang-Ryeol;Kim, Hyeon-Seung;Jeong, U-Chang;Gwon, Min-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.489-489
    • /
    • 2013
  • AF 코팅은 유리나 플라스틱과 같은 기재 표면을 특수 처리하여 지문과 같은 오염물질의 부착방지와 오염물질이 부착되더라도 쉽게 제거 가능하도록 하는 기술이다. 전자, 자동차, 건축, 섬유, 철강분야 등에 활용 가능한 중요기술로 박막의 발수 발유 기능을 부여하는 표면처리 기술이고, 코팅방법에는 진공증착, 스핀코팅, 딥코팅, 플로우 코팅, 스프레이 코팅 등이 있으며, 경화 방법이나 접촉각 등의 특성이 반영된다. 터치패널 등의 지문부착방지 기술은 불소계와 비불소계 재료로 구분할 수 있지만 지문을 쉽게 지울 수 있고, 오염 방지 기능과 내구성이 있으며, 우수한 광학특성을 유지하는 것이 과제라 할 수 있다. 그리고 항균성을 부여하는 기술도 개발되고 있다. 이런 터치패널의 강화유리에 AF 코팅한 제품은 핸드폰 글래스에 처음 적용하면서부터 실생활에 도입이 시작되고 있다. 이러한 AF 코팅을 스퍼터링 법을 이용하여 증착 시켰다. 기존에는 E-beam을 이용한 증착 방식이 주를 이루었지만, 스퍼터링 법을 이용함으로써 박막의 균일화 및 대량생산이 가능해졌다. 따라서 이 연구에서는 기존의 E-beam 방식과 sputtering 공정 중 ion source에 의한 전처리의 유무에 따른 박막의 특성을 비교하였다. 내부식성, 내마모성 시험을 거친 후, 접촉각을 측정하여 알아보았으며, 박막의 건전성 및 균일성은 FE-SEM을 이용하여 관찰하였다. 실험용 장비가 아닌 실제 생산장비인 직경 1,400 파이의 장비를 이용하여 증착하였으며 염수분무 및 내마모 시험 후, 기존 접촉각의 ${\pm}5^{\circ}$ 내외임을 확인 할 수 있었고, 박막의 건전성 또한 뛰어남을 알 수 있었다.

  • PDF

Diagnostic assessment on vegetation damage due to hydrofluoric gas leak accident and restoration planning to mitigate the damage in a forest ecosystem around Hube Globe in Gumi (구미 휴브글로브 주변 삼림생태계에서 불화수소가스 유출 사고에 기인한 식생피해 진단 및 그 피해를 완화시키기 위한 복원 계획)

  • Kim, Gyung Soon;An, Ji Hong;Lim, Chi Hong;Lim, Yun Kyung;Jung, Song Hie;Lee, Chang Seok
    • Journal of Wetlands Research
    • /
    • v.17 no.1
    • /
    • pp.45-52
    • /
    • 2015
  • We obtained the following results from investigation on vegetation damage from 5 to 6 August, 2013, about one year after an accident that hydrofluoric acid leaked from a chemical maker, Hube Globe in Gumi. Pinus densiflora and Pinus strobus showed very severe damage. Ginko biloba, Quercus acutissima, Pinus rigida, Salix glandulosa, Hibiscus syriacus, and Lagerstroemia indica showed severe damage. Quercus variabilis, Lespedeza cyrtobotrya, and Miscanthus sinensis showed moderate damage. Quercus aliena, Smilax china, Arundidinella hirta, Ailanthus altissima, Robinia pseudoacacia, and Paulowinia coreana showed slight damage. We did not find any plants without leaf damage around there. This result means that fluoride damage still persists in this area as was known that fluoride remains for a long time in air, soil and water and exerts negative effects at all levels of an ecosystem. In addition, fluoride content contained in plant leaf depended on the distance from a fertilizer producing factory and vegetation damage tended to proportionate to the concentration in the Yeocheon industrial complex. In these respects, a measure for removal or detoxification of the remaining fluoride is urgently required around the hydrofluoric acid leak spot. Fertilizing of dolomite containing Ca and Mg, which can trap fluoride, was prepared as one of the restoration plans. In addition, phosphate fertilizing was added in order to enhance soil ameliorating effects. Furthermore, we recommend the introduction of tolerant plants as the second measure to mitigate fluoride damage. As the tolerant plants to make a new forest by replacing trees died due to hydrofluoric acid gas damage, we recommended Q. aliena and S. china, A. hirta, etc. were recommended as plant species to add mantle vegetation to the forest margin to ensure stable interior environment of the forest.

Effect of Calcium Sources for the Treatment of Wastewater Containing High Fluoride (고농도의 불소함유폐수 처리시 칼슘원에 따른 영향)

  • Kim, Seung-Ha;Kim, Keum-Yong;Ryu, Hong-Duck;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.5
    • /
    • pp.307-313
    • /
    • 2011
  • As production of LCD increases, it has become necessary to find an economically efficient way of treating LCD wastewater with high concentration of fluoride. This study focuses on the calcium sources : $CaCl_2$, $Ca(OH)_2$ and $CaCO_3$ for the treatment of the LCD wastewater including high concentration of fluoride. Of course considering removal efficiency and economical aspect, study is continued. Then this study have objective giving aid to field. Consequently, each calcium source's removal efficiency was measured in various pH, calcium dosage, reaction time, and mixing intensity. The optimum operational conditions for $CaCl_2$ were found to be pH of 7, calcium dosage of 0.4[Ca]/[F] (mol / mol), 1 hr of operation and 200 rpm of mixing intensity. For $Ca(OH)_2$, they were pH of 7, calcium dosage of 30 mL/L, 1 hr of operation, and 200 rpm of mixing intensity. While $CaCO_3$ had operational conditions of pH of 4, calcium dosage of 30 mL/L, 1 hr operation and 200 rpm of mixing intensity. But it is recommended to use calcium sources according to various field conditions.

A Study on the Dental Health Status and Knowledge of the Volunteers in Practice for Oral Prophylaxis (치면세마실습 대상자의 구강건강수준과 구강보건지식에 관한 연구)

  • Kim, Eung-Gwon;Lim, Soon-Hwan;Park, Mi-Young
    • Journal of dental hygiene science
    • /
    • v.9 no.3
    • /
    • pp.287-294
    • /
    • 2009
  • The purpose of this survey research was to investigation the relationship among dental health state, care and knowledge of patients who participate in dental hygiene process of dental hygiene students voluntarily. And the following conclusion were obtained from questionnaires for 266 volunteers using SPSSWIN 12.0. 1. For the dental health state according to sex distinction, it showed that women (DMFT index: 13.0) was higher than men (DMFT index: 10.4) and statistically significant difference. For DT rate, men (32.0) was higher than women (30.0), for MT rate men (32.2) was higher than women (26.6) and it showed statistically significant difference (P<0.05). 2. For the dental health knowledge according to sex distinction, 77.8% patients replied as the food causing teeth decay are chocolate, biscuits, etc. and it didn't showed significant difference statistically. 72.4% men and 84.7% women replied as they could take precautions against a dental caries using fluorine and it showed statistically significant difference(P<0.05). 3. For brushing their teeth from top to down for the upper tooth and from down to top for the lower one, 80.3% patients replied as they did like that but 62.5% patients as they didn't. And 68.2% patients replied as the food causing teeth decay arc chocolate, biscuits, etc. and 81.0% patients didn't like that. It showed statistically significant difference. (P<0.05) 4. 50.5% patients went to the dental hospital once per 6 month and it showed statistically significant difference. And 71.3% patients replied as the food causing teeth decay are chocolate, biscuits, etc. and 81.0% patients didn't like that, It showed statistically significant difference. (P<0.05)

  • PDF

A Study on Applicability of Hydrofluoroethers as CFC-Alternative Cleaning Agents (CFC 대체 산업세정제로의 HFEs의 적용가능성 연구)

  • Min, Hye-Jin;Shin, Jin-Ho;Bae, Jae-Heum;Kim, Hong-Gon;Lee, Hyun-Joo
    • Clean Technology
    • /
    • v.14 no.3
    • /
    • pp.184-192
    • /
    • 2008
  • Fluoride-type cleaning agents such as 2,2,2-trifluoroethanol (TFEA) and hydrofluoroethers (HFEs) do not destroy ozone in the stratosphere and have low global warming potential compared to hydrofluorocarbons(HFCs) and hydrochlorofluorocarbons (HCFCs). Especially, HFEs which have no flash point are paid attention as next generation type of cleaning agents for chlorofluorocarbons (CFCs) since they are safe in handling and have excellent penetration ability compared to hydrocarbon cleaning agents with low flash point. Here, the physical properties and cleaning abilities of fluoride-type cleaning agents such as TFEA, HFE-7100, HFE-7200, HFE-476mec, HFE-449mec-f, AE-3000 and AE-3100E and silicide-type cleaning agents such as trifluoroetoxytrimethylsilane (TFES) and hexamethyldisilazane (HMDS) were measured and compared with those of ozone destruction substances such as CFC-113 and 1,1,1-trichloroethane. They were also compared with toxic methylene chloride (MC) and isopropyl alcohol (IPA) which are now being used as an alternative cleaning agents. As a result, TFEA and HFEs had lower cleaning ability for removal of various soils compared to chloride-type cleaning agents, but they showed excellent cleaning ability fur fluoride-type soils. TFES and HMDS also showed excellent cleaning ability for silicide-type soils.

  • PDF

THE EFFECTS OF FLUORIDE RELEASING ORTHODONTIC SEALANT ON THE SHEAR BOND STRENGTH Of LIGHT-AND CHEMICAL-CURED ORTHODONTIC RESINS (불소가 유리되는 교정용 전색제가 광중합형 및 화학중합형 교정용 접착제의 전단결합강도에 미치는 영향)

  • Kim, Bong-Hyun;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.781-789
    • /
    • 1997
  • The purpose of this study was to evaluate the effects of fluoride relasing orthodontic sealant on the shear bond strength of light-and chemical-cured orthodontic rosins, to compare the shear bond strenth with light-and chemical-cured orthodontic resins, and to identify the changes of shear bond strength by rebonding in vitro. The brackets were divided into eight groups. Each group of metal brackets had different bonding mechanisms with adhesives. Group A : Transbond only Group B : Mono-Lok 2 only Group C : Light cured FluoroBond+Transbond Group D : Light cured FluoroBond+Mono-Lok 2 Group E : Transbond only(rebonded) Group F : Nomo-Lok 2 only(rebonded) Group G : Light cured FluoroBond+Transbond(rebonded) Group H : Light cured FluoroBond+Mono-Lok 2(rebonded) 65 extracted human premolars were prepared for bonding and 65 metal brackets for each group were bonded to prepared enamel surfaces of buccal surfaces as the above prescription. 24 hours bonding after, the Instron universal testing machine was used to test the shear bond strength of metal brackets to enamel. After debonding, same kind of metal brackets for each group were rebonded to prepared enamel surfaces of buccal surfaces to test the shear bond strength at the rebonding to enamel. Statistical analysis of the data was carried out Student's t-test ANOVA test, and Scheffe test using $SPSS/PC^+$ The results were as follows : 1. The order of shear bond strength was Group B(11.84MPa), Group A(10.75MPa), Group, D(9.69MPa), and Group C(9.39MPa)in lst bonded groups. 2. The order of shear bond strength was Group E(7.40MPa), Group G(6.48MPa), Group F(5.89MPa), and Group H(5.15MPa) in rebonded groups. 3. The shear bond strength of chemical cured orthodontic rosins had higher than that of light-cured orthodontic resins in all groups, but there was no statistical significance between groups(P>0.05). 4. In rebonded groups, the shear bond strength of light cured orthodontic rosins had higher than that of chemical cured orthodontic resins, but there was no statistical significance between groups(P>0.05). 5. The shear bond strength of all rebonded groups progressively decreased than that of 1st bonded groups, and there was statistical significance between groups(p<0.05, p<0.001).

  • PDF

Defluoridation of Wastewater by Adsorption on Bituminous Coal Fly Ash (유연탄 소각 비산재를 이용한 폐수중의 불소이온 제거)

  • 이성대;박석환;정문식
    • Journal of Environmental Health Sciences
    • /
    • v.19 no.1
    • /
    • pp.51-56
    • /
    • 1993
  • This study was performed to find the ability of bituminous coal fly ash to remove fluoride from water and wastewater at different fluoride concentration, reaction temperature, reaction time and pH. The removal of fluoride is favorable at low concentration, high temperature and acidic pH. With the increase in the initial fluoride concentration, the amount adsorbed increased. Adsorption process was exothermic at pH 2.0. Physisorption process was predominant over pH 2.3, while Chemisorption was under pH 2.3. Fluoride uptake by fly ash was conducted the adherence of fluoride on the active surface sites of adsorbent and its intraparticle diffusion within adsorbent. The values of rate constants of adsorption were 3.028X 10$^{-3}$, 4.715X 10$^{-3}$, 2.88X 10$^{-3}$ (min) and intraparticle diffusion were 1.434X10$^{-3}$, 3.012X10$^{-3}$, 5.635X10$^{-3}$ at each temperatures.

  • PDF

Optimum Condition for Fluoride Removal Prior to the Application of Struvite Crystallization in Treating Semiconductor Wastewater (Struvite 결정화를 이용한 반도체 폐수처리 시 불소제거를 위한 최적 조건)

  • An, Myeong Ki;Woo, Gwi Nam;Kim, Jin Hyung;Kang, Min Koo;Ryu, Hong Duck;Lee, Sang-Ill
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.916-921
    • /
    • 2009
  • This study was aimed to both enhance the fluoride removal and to reduce the phosphorus removal in treating semiconductor wastewater using $Ca(OH)_2$ at low pH so as to facilitate struvite crystallization reaction. The struvite crystallization could be introduced after fluoride removal by retaining the phosphorus source. As the results, the method applied in this study achieved high fluoride removal efficiency (about 91%) with retardation of phosphorus removal at pH 4, compared to conventional methods where the removal of fluoride and phosphorus were done at pH 11. Therefore, the fluoride removal at low pH would contribute to the enhancement of nitrogen and phosphorus removals in a consecutive struvite crystallization reactor. Treatment of semiconductor wastewater at low pH using $Ca(OH)_2$ also had lower (about 20%) water content of precipitated sludge compared to conventional method. As the molar ratio of Ca to F increased the removal efficiencies of fluoride and phosphorus increased. Although the amount of seed dosage didn't affect the removal of fluoride and phosphorus, its increase reduced the water content of precipitated matter. Finally, considering consecutive struvite reaction, the optimum condition for the removal of fluoride and phosphorus was as follow: pH: 4, the molar ratio of Ca:F: 1:1.

Calcium Removal from Effluent of Electronics Wastewater Using Hydrodynamic Cavitation Technology (수리동력학적 캐비테이션을 이용한 전자폐수 처리수에 함유된 칼슘저감에 관한 연구)

  • Park, Jin-Young;Kim, Sun-Jip;Lee, Yong-Woo;Lee, Jae-Jin;Hwang, Kyu-Won;Lee, Won-Kwon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.6
    • /
    • pp.715-721
    • /
    • 2007
  • Residual calcium concentration is high, in general, at the effluent of the fluoride removal process in the electronics industry manufacturing semiconductor and LCD. To increase the stability of the membrane process incorporated for reuse of wastewater, the residual calcium is required to be pre-removed. Hyperkinetic Vortex Crystallization(HVC) process was installed in the electronics industry manufecturing semi conductor as a pilot scale for accelerating calcification of calcium ion. Compared to the conventional soda ash method, the 31% higher calcium removal efficiency was achieved when HVC was applied at the same sodium carbonate dosage. In order to maintain the economic calcium removal target of 70% preset by manufacturer, the dosing concentration of the soda ash was 530 mg/L based on influent flowrate. The seed concentration in the reactor was one of the critical factors and should be maintained in the range of $800\sim1,200mg$ SS/L to maximize the calcium removal efficiency. The calcite production rate was 0.30 g SS/g $Na_2CO_3$ in the average. The economic HVC passing time of the mixture was in the range of $2\sim5$ times. Relatively, stable calcium concentration was maintained in the range of $30\sim72$ mg/L(average 49 mg/L) although the calcium concentration in the feed was severely fluctuated with $74\sim359$ mg/L(average 173 mg/L). The HVC process was characterized as environment-friendly technology reducing chemical dosage and chemical sludge production and minimizing maintenance cost.