• Title/Summary/Keyword: 불소계 화학물질

Search Result 12, Processing Time 0.029 seconds

A study on the emission of fluorine-based chemicals and the detection of perfluorooctane sulfonic acids(PFOS) and perfluorooctanoic acids(PFOA) in domestic main rivers (국내 불소계 화학물질 배출 현황 및 주요 수계의 과불화화합물(PFOS, PFOA) 검출 특성에 관한 연구)

  • Sam-Bae Park;Yoon-Young Chang
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.2
    • /
    • pp.5-18
    • /
    • 2023
  • As a result of the survey on the emission status of fluorine-based chemicals in Korea, 13 kinds of substances, including hydrogen fluoride (91%) and perfluorocarbons (5%), were emitted in workplaces. By regional groups, about 98% was emitted in the Gyeongbuk, Gyeonggi and Chungcheong regions, and about 98% in three sectors of industry related to manufacture of electronic parts, chemicals and non-metallic mineral products. The detection status of PFOS and PFOA in domestic main rivers was continuously detected in the Nakdong River, the Geum River and the Anseong Stream estuary with high fluorine-related chemical emissions, and four sites of PFOS and two sites of PFOA were detected for the first time in 2021. PFOS and PFOA were continuously detected in relatively high concentrations in the rivers where there were many semiconductor and display related sectors of industry.

Estimation of VOCs Emissions from Laundries (세탁시설에서 방출되는 VOCs의 배출량 산정)

  • 김만구;박정진;정영림
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.231-232
    • /
    • 2002
  • 대기 중 휘발성유기화합은 오존생성의 전구물질 및 유해화학물질 그리고 일부는 악취물질로 작용하는 주요 대기오염물질로 주목받고 있으며, 여러 가지 VOCs의 배출원 중에서 세탁소도 주요 발생원중 하나로 주목받고 있다. 세탁에 사용되는 유기용제에는 퍼클로로에틸렌(PCE)과 불소계용제, 석유계 용제가 있는데 일본을 제외한 외국에서는 밀폐형기계인 PCE를 사용하고 있는데 반해, 우리나라에서는 약 95% 정도의 세탁소가 석유계 용제를 사용하고 있다. (중략)

  • PDF

PFA 라이닝 밸브의 헬륨누설 측정 및 비산배출 평가

  • Lee, Won-Ho;Lee, Won-Seop;Lee, Jong-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.121.2-121.2
    • /
    • 2016
  • PFA 라이닝 밸브 (PFA Lined Valve)는 고온 (~120oC) 고압 (~10 bar)에서 강한 부식성을 갖은 화학물질 (염산, 황산, 질산 등)을 이송시킬 수 있도록 내식성, 비점착성, 내열성 향상을 위한 불소계 수지 PFA (Perfluoroalkoxy)가 밸브 내면부에 가공되어 있으며, 고순도 화학약품 및 반도체 LCD 석유화학 제철 제약 분야 등의 제조공정에서 사용되고 있다. 미국 EPA (Environmental Protection Agency)에서는 석유화학 플랜트에서 발생되는 비산배출 (fugitive emission)의 대부분인 60% 정도가 밸브에서 발생된다고 보고하고 있으며, 근래 빈번한 불산 노출사고 내용을 매스컴에서 접할 수 있는 것처럼 PFA 라이닝 밸브가 설치되는 산업현장에서는 미소 누설에도 치명적인 인명피해 사고가 발생하기 때문에 국제규격에 따른 PFA 라이닝 밸브의 기밀누설에 관한 규제 및 관리가 중요하다. 본 논문에서는 가압진공법을 이용하여 PFA 라이닝 볼밸브의 비산배출 측정하였으며, 작동횟수/온도변화에 따른 PFA 라이닝 볼밸브의 비산배출 특성을 고찰하였다.

  • PDF

Analytical method for combustible waste contaminated by the HF leakage from industrial process (산업공정에서 불산누출로 오염된 가연성 폐기물의 분석방법 연구)

  • Kang, Young-Yeul;Kim, Yong-Jun;Kim, Woo-Il;Yoon, Cheol-Woo;Yeon, Jin-Mo;Shin, Sun-Kyoung;Oh, Gil-Jong
    • Analytical Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.167-171
    • /
    • 2014
  • Hydrofluoric acid (HF), a typical inorganic acid, has been used in the industry for its various usage and classified as the toxic compound, because it can cause the pneumonia and pulmonary edema when it was exposed to respiratory organs. The official environmental analytical method for fluorine and its compound in waste has not been developed. For this reason, we have faced some problem to treat the contaminated wastes by the HF leakage from industrial process. In this study, prepared for analytical method for combustible waste (crop, trees, etc.) generated from HF leaking accident and to be applied as the official analytical method for fluorine contaminated waste when the fluorine and its compound will be regulated as a hazardous material by the waste management law later.

Influence of Perfluorinated Polymer Passivation on AlGaN/GaN High-electron-mobility Transistors (질화갈륨계 고전자이동도 트랜지스터에 대한 불소계 고분자 보호막의 영향)

  • Jang, Soohwan
    • Korean Chemical Engineering Research
    • /
    • v.48 no.4
    • /
    • pp.511-514
    • /
    • 2010
  • Perfluorinated polymer($Cytop^{TM}$) was deposited on selective area of AlGaN/GaN HEMT structure using low cost and simple spin-coating method, and the electrical characteristics of the device was analyzed for application of passivation layer on semiconductors. Gate lag measurement results of $Cytop^{TM}$ passivated and unpassivated HEMT were compared. Passivated device shows improved 65 % pulsed drain current of dc mode value. Rf measurements were also performed. $Cytop^{TM}$ passivated HEMT have similar rf performance to PECVD grown $Si_3N_4$ passivated device. $Cytop^{TM}$ passivation layer may play an important role in mitigating surface state trapping in the region between gate and drain.

Removal of Nitrogen Using by SOD Process in the Industrial Wastewater Containing Fluoride and Nitrogen from the Zirconium Aolly Tubing Production Factory of the Nuclear Industry (원자력산업 지르코늄합금 튜브 생산공장에서 배출되는 불소.질소 함유 폐수의 황산화탈질을 이용한 질소처리)

  • Cho, Nam-Chan;Moon, Jong-Han;Ku, Sang-Hyun;Noh, Jae-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.11
    • /
    • pp.855-859
    • /
    • 2011
  • The main pollutants from zirconium alloy tubing manufacturing process in nuclear industry are nitrate ($NO_3-N$) and fluoride (F-)Nitric acid, and hydrofluoric acid is used for acid pickling. The process for the removal of nitrate and fluoride is composed of 1st chemical coagulation, SOD (Sulfur Oxidation Denitrification) process using sulfur-oxidizing denitrification, and 2nd chemical coagulation. The characteristic of the wastewater treatment is an application of SOD process. The SOD Process is highly received attention because it is significantly different from existing processes for sulfur denitrification. A JSC (JeonTech-Sulfur- Calcium) Pellet is unification of sulfur and alkalinity material. According to result of SOD process in wastewater treatment plant, the removal efficiency of T-N was over 91% and the average concentration of T-N from influent was 147.55 mg T-N/L and that from effluent was 12.72 mg T-N/L. Therefore, SOD process is a useful to remove nitrogen from inorganic industrial wastewater and a new development of microbial activator was shown to be stable for activation of autotrophic bacteria.

Physical Properties and Cleaning Ability of New Cleaning Agents Based on 2,2,2-trifluoroethanol (TFEA) (2,2,2-trifluoroethanol (TFEA)를 기초로한 세정제의 물성 및 세정성 영향 연구)

  • Cha, An Jung;Park, Ji Na;Kim, Honggon;Bae, Jae Heum
    • Applied Chemistry for Engineering
    • /
    • v.16 no.4
    • /
    • pp.533-541
    • /
    • 2005
  • Non-aqueous cleaning agents were formulated with 2,2,2-trifluoroethanol (TFEA) and hydrofluoroether (HFE), and their physical properties and cleaning abilities were examined. TFEA-based aqueous cleaning agents were also formulated with nonionic surfactants, hydrotropes and builders, and their cleaning abilities were compared. Possibilities of these cleaning agents as substitutes for CFC-113 and 1,1,1-TCE were finally evaluated. In this work, fluxes, cutting oils, greases, and fluoric oils were selected as model contaminants for cleaning experiments. These contaminants have different properties of water-solubility or hydrophilicity, and fat-solubility or lypophilicity. Cleaning abilities of TFEA-based cleaning agents were analyzed and compared through the measurement of contaminant weight changes as a function of cleaning time, and their possibilities as alternative cleaning agents were evaluated. As a result, it was shown that TFEA and HFE-based non-aqueous cleaning agents have quite a good cleaning power for fluxes and fluorine soils but low one for greases. And TFEA-based agueous cleaning agents which consisted of nonionic surfactants, hydrotrope, and builders were very effective for cleaning fluxes and greases under certain formulation conditions. Thus, it was revealed that the TFEA-based cleaning agents were very effective for cleaning specific contaminants and can be used as substitutes for CFC-113 and 1,1,1-TCE in some industrial applications.

Adsorption Characteristics of Toluene Gas Using Fluorinated Phenol-based Activated Carbons (불소화 처리된 페놀계 활성탄소를 이용한 톨루엔 가스흡착 특성)

  • Kim, Min-Ji;Jung, Min-Jung;Kim, Min Il;Choi, Suk Soon;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.26 no.5
    • /
    • pp.587-592
    • /
    • 2015
  • Activated carbons (ACs) were treated by fluorination to improve the adsorption property of toluene gas among volatile organic compounds (VOCs). The pore characteristics and surface properties of these activated carbons were evaluated by BET and XPS and the adsorption property and removal efficiency of toluene gas was investigated by gas chromatography. The breakthrough time of fluorinated ACs was increased about 27% compared to that of untreated ACs when the toluene gas of 100 ppm was flowed at a flow rate of $300cm^3/min$. Fluorinated AC of 0.1 g adsorbent totally adsorbed toluene gas in 100 ppm to 100 % during the adsorption time in 19 h. These results can be used as a treatment technology or removal of carcinogenic materials such as toluene.

A Study on Denitrification by Sulfur-Oxidizing Bacteria for the Industrial Wastewater Contain Fluoride and Nitrogen (불소.질소 함유 폐수의 황산화탈질에 관한 연구)

  • Cho, Nam-Chan;Moon, Jong-Han
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.10
    • /
    • pp.774-781
    • /
    • 2011
  • Nitric acid and hydrofluoric acid are used for acid pickling in zirconium alloy tubing manufacturing process. Nitrate and fluoride in the wastewater were treated by chemical coagulation and SOD (Sulfur Oxidation Denitrification) process. This study is investigated the effect of fluoride concentration and the optimal condition for SOD process. The limited fluoride concentration for SOD process was below 20 mg F-/L. The adjusted pH and alkalinity by NaOH and $NaHCO_3$ was shown to be more effective for removal of nitrate compared with using NaOH. Furthermore, the microbial activator mixed trace elements and ingredient for alkalinity did not only supplement with alkalinity but also enhance the growth and proliferation for sulfur-oxidizing bacteria. As a result, the inorganic industrial wastewater was successfully treated by the microbial activator in SOD process without continuous addition of seed sludge. Finally, SOD process was shown to remove nitrate in industrial wastewater and to contribute the microbial activator for activation of sulfur-oxidizing bacteria.

Preparation of Water-Repellent Coating Films from Tetraethoxysilane and Chlorotrimethylsilane on PMMA Substrates (Tetraethoxysilane과 Chlorotrimethylsilane으로부터 PMMA 기재 위에 발수성 코팅 도막 제조)

  • Park, Jong Ho;Lee, Byung Wha;Song, Ki Chang
    • Korean Chemical Engineering Research
    • /
    • v.57 no.1
    • /
    • pp.124-132
    • /
    • 2019
  • Water-repellent coating solutions were synthesized by hydrolysis and polycondensation reactions with water using tetraethoxysilane (TEOS) and chlorotrimethylsilane (CTMS) as precursors. The solutions were coated on a PMMA sheet and thermally cured to prepare non-fluorinated water-repellent coating films. Coating films were characterized by water contact angles, UV-Vis transmittance and surface morphology. The contact angle of coating films prepared by varying the molar ratio of CTMS/TEOS to 0.6~1.0 exhibited a maximum value of $107^{\circ}$ when the CTMS/TEOS molar ratio was 0.8. The coating films showed a high transmittance over the visible range up to 90% when the CTMS/TEOS molar ratios were 0.6~0.8. However, when the molar ratios of CTMS/TEOS were 0.9~1.0, the transmittance of coating films was lower than 70% due to an uneven shape of the rough surface.