• Title/Summary/Keyword: 분할 TR

Search Result 46, Processing Time 0.032 seconds

Desmutagenic Effects of Maillard Reaction Products against Mutagenic Heterocyclic Amines (변이원성 Heterocyclic Amine에 대한 Maillard 반응생성물의 변이원성 억제효과)

  • KIM Seon-Bong;PARK Yeung-Ho;HAYASE Fumitaka;KATO Hiromichi
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.19 no.2
    • /
    • pp.127-135
    • /
    • 1986
  • Each molecular weight (Mw) fraction of melanoidins prepared from a D-glucose and glycine system, i. e., Mw below 1,000, Mw between 1,000 to 5,000 and Mw above 5,000 and nondialyzable and ozone-treated melanoidins were reacted with heat-induced mutagens such as Trp-P-1, Trp-P-2, Glu-P-1, Glu-P-2 and IQ at $37^{\circ}C$ for 30 min. The inhibitory effects of the melanoidins on the mutagens increased with increasing molecular weight. The reducing ability ana antioxidative activity of melanoidins also increased in proportion to the increase in molecular weight, whereas the mutagenic inhibitory effect decreased on reduction of the melanoidins with sodium borohydride. It was also observed that a part of Trp-P-1 was adsorbed to melanoidin molecules. On modification of amino groups of these mutagens with carbonyl compounds derived through the Maillard reaction such as diacetyl and glyceraldehyde, their mutagenic activities were remarkably suppressed. Accordingly, it is speculated that the mutagenic inhibitory action of melanoidins is due to their reducing ability and antioxidative activity, and electrostatic binding and carbonyl groups of the melanoidin molecules.

  • PDF

Distinction of Internal Tissue of Red Ginseng Using Magnetic Resonance Image (MRI을 이용한 홍삼 내부조직 판별)

  • Kim, Chun-Suk;Jung, In-Chan;Kim, Se-Bong
    • Journal of Ginseng Research
    • /
    • v.32 no.4
    • /
    • pp.332-336
    • /
    • 2008
  • Red ginseng is classified according to outer form and the quality of internal tissue, and red ginseng below third grade can't be sold. Also there are many differences in price according to grade. So if inferior Red ginseng is sold, economic loss and claim take place. This research is done conducted to investigate the possibility of the non-destruction internal tissue investigation of red ginseng. It is observed and compared that MR image after getting MR image agrees with real cutting side in 10-13% water content of red ginseng. The MR image can be obtained to see the internal section of red ginseng with equal condition of time, temperature and slice thickness in spin echo pulse sequence. The MR signal of red ginseng is very weak, because it contains low water density. So it takes about 30 minutes with the measurement of single point image (SPI). But the suitable time to distinguish internal tissues is about 9 seconds in TE (Echo Time) 2.23 ms, TR (Repetition Time) 150ms. The image to discriminate internal tissues in 9 seconds can be obtained when slice thickness is 10 mm with changes of 3, 5, 10 mm. The image obtained after 30 minutes' boiling of 55 degrees has clearer image than that of normal temperature. It is thought that MR signal is stronger through active motion of water particles as temperature increases. With this method MR image of red ginseng can be obtained and characteristics of internal tissues can be observed in such a short time.

Signal to Noise Ratio of MR Spectrum by variation echo time : comparison of 1.5T and 3.0T (Echo time에 따른 MR spectrum의 SNR: 1.5T와 3.0T비교)

  • Kim, Sung-Gil;Lee, Kyu-Su;Rim, Che-Pyeong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.401-407
    • /
    • 2011
  • The purpose of this study is to know the differences of MR spectra, obtained from normal volunteers by variable TE value, through the quantitative analysis of brain metabolites by peak integral and SNR between 1.5T and 3.0T, together with PRESS and STEAM pulse sequence. Single-voxel MR proton spectra of the human brain obtained from normal volunteers at both 3.0T MR system (Magnetom Trio, SIEMENS, Germany) and 1.5T MR system (Signa Twinspeed, GE, USA) using the STEAM and PRESS pulse sequence. 10 healthy volunteers (3.0T:3 males, 2 females; 1.5T : 3 males, 2 females) with the range from 22 to 30 years old (mean 26 years) participated in our study. They had no personal or familial history of neurological diseases and had a normal neurological examination. Data acquisition parameters were closely matched between the two field strengths. Spectra were recorded in the white matter of the occipital lobe. Spectra were compared in terms of resolution and signal-to-noise ratio(SNR), and echo time(TE) were estimated at both field strengths. Imaging parameters was used for acquisition of the proton spectrum were as follow : TR 2000msec, TE 30ms, 40ms, 50ms, 60ms, 90ms, 144ms, 288ms, NA=96, VOI=$20{\times}20{\times}20mm3$. As the echo times were increased, the spectra obtained from 3.0T and 1.5T show decreased peak integral and SNR at both pulse sequence. PRESS pulse sequence shows higher SNR and signal intensity than those of STEAM. Especially, Spectra in normal volunteers at 3.0T demonstrated significantly improved overall SNR and spectral resolution compared to 1.5T(Fig1). The spectra acquired at short echo time, 3T MR system shows a twice improvement in SNR compared to 1.5T MR system(Table. 1). But, there was no significant difference between 3.0Tand 1.5T at long TE It is concluded that PRESS and short TE is useful for quantification of the brain metabolites at 3.0T MRS, our standardized protocol for quantification of the brain metabolites at 3.0T MRS is useful to evaluate the brain diseases by monitoring the systematic changes of biochemical metabolites concentration in vivo.

Kinetic Studies on Hydration of Traditional and High-Yielding Rice Varieties (일반쌀 및 다수확 쌀의 수화속도)

  • Lee, Soon-Ock;Kim, Sung-Kon;Lee, Sang-Kyu
    • Applied Biological Chemistry
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 1983
  • The hydration of two japonica(Akibare and Milyang 15) and four indica(Milyang 30, Suweon 287, Suweon 294 and Iri 342) rice varieties was investigated in terms of mathematical rate equation. The hydration rate at temperatures of $4{\sim}32^{\circ}C$ was examined by a weighing method. The absorption of water was directly proportiponal to the square root of the hydration time(t) and was described by the diffusion equation: $1-\bar{M}=(2/\sqrt{\pi})(S/V)\;\sqrt{Dt},\;where\;\bar{M}$ is dimensionless moisture ratio, S/V is the surface-to-volume ratio and D is diffusion coefficient. The average D value was given by the Arrhenius relation: $D=D_0\;\exp(-E_a/TR)$. The activation energy was $4{\sim}5kcal/mole$. The rice samples could be classified into three groups based on hydration kinetics: Milyang 30-Suweon 287; Akibare-Milyang 15; and Suweon 294-Iri 342.

  • PDF

Flow Field Separating Technique in Bubbly Flow using Discrete Wavelet (이산 웨이블릿을 이용한 Bubbly flow의 유통분리기법)

  • Jo, Hyo-Jae;Doh, Deog-Hee;Choi, Je-Eun;Takei, Masahiro;Kang, Byung-Yoon
    • Journal of Navigation and Port Research
    • /
    • v.32 no.10
    • /
    • pp.777-783
    • /
    • 2008
  • Nowadays wavelet transforms are widely used for the analyses of PIV velocity vector fields. This is bemuse the wavelet provides not only spatial information of the velocity vectors but also of time and frequency domains. In this study, a discrete wavelet trC1f1$form has been applied to real PIV images of bubbly flows. The vector fields obtained by a self-made cross-correlation PIV algorithm were used for the discrete wavelet transform The performances of the discrete wavelet transform is investigated by changing the level of power of discretization. The decomposed images by the wavelet multiresolution showed conspicuous characteristics of the bubbly flows according to the level changes. The high spatial bubble concentrated area could be evaluated by the constructed discrete wavelet transform algorithm, at which high leveled wavelets could play a dominant roles to reveal the flow characteristics.

Hybrid Two-Dimensional Proton Spectroscopic Imaging of Pediatric Brain: Clinical Application (소아 뇌에서의 혼성 이차원 양성자자기공명분광법의 임상적 응용)

  • Sung Won Youn;Sang Kwon Lee;Yongmin Chang;No Hyuck Park;Jong Min Lee
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.64-72
    • /
    • 2002
  • Purpose : To introduce and demonstrate the advantages of the new hybrid two-dimensional (2D) proton spectroscopic imaging (SI) over the single voxel spectroscopy (SVS) and conventional 2D SI in the clinical application of spectroscopy for pediatric cerebral disease. Materials and Methods : Eighty-one hybrid 2D proton spectroscopic imaging was performed in 79 children (36 normal infants and children, 10 with hypoxic-ischemic injury, 20 with toxic-metabolic encephalopathy, seven with brain tumor, three with meningoencephalitis, one with neurofibromatosis, one with Sturge-Weber syndrome and one with lissencephaly) ranging in age from the third day of life to 15 years. In adult volunteers (n=5), all three techniques including hybrid 2D proton SI, SVS using PRESS sequence, and conventional 2D proton SI were performed. Both hybrid 2D proton SI and SVS using PRESS sequence were performed in clinical cases (n=). All measurements were performed with a 1.5-T scanner using standard head quadrature coil. The 16$\times$16 phase encoding steps were set on variable field of view (FOV) depending on the size of the brain. The hybrid volume of interest inside FOV was set as $75{\times}75{\times}15{\;}\textrm{mm}^3$ or smaller to get rid of unwanted fat signal. Point-resolved spectroscopy (TR/TE=1,500 msec/135 or 270msec) was employed with standard chemical shift selective saturation (CHESSI pulses for water suppression. The acquisition time and spectral quality of hybrid 2D proton SI were compared with those of SVS and conventional 2D proton SI. Results : The hybrid 2D proton SI was successfully conducted upon all patients.

  • PDF

Implicit Distinction of the Race Underlying the Perception of Faces by Event-Related fMRI (Event-related 기능적 MRI 영상을 통한 얼굴인식과정에서 수반되는 무의식적인 인종구별)

  • Kim Jeong-Seok;Kim Bum-Soo;Jeun Sin-Soo;Jung So-Lyung;Choe Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.1
    • /
    • pp.43-49
    • /
    • 2005
  • A few studies have shown that the function of fusiform face area is selectively involved in the perception of faces including a race difference. We investigated the neural substrates of the face-selective region called fusiform face area in the ventral occipital-temporal cortex and same-race memory superiority in the fusiform face area by the event-related fMRI. In our fMRI study, subjects (Oriental-Korean) performed the implicit distinction of the race while they consciously made familiar-judgments, regardless of whether they considered a face as Oriental-Korean or European-American. For race distinction as an implicit task, the fusiform face areas (FFA) and the right parahippocampal gyrus had a greater response to the presentation of Oriental-Korean faces than for the European-American faces, but in the conscious race distinction between Oriental-Korean and European-American faces, there was no significant difference observed in the FFA. These results suggest that different activation in the fusiform regions and right parahippocampal gyrus resulting from superiority of same-race memory could have implicitly taken place by the physiological processes of face recognition.

  • PDF

Evaluation of Cerebral Aneurysm with High Resolution MR Angiography using Slice Interpolation Technique: Correlation wity Digital Subtraction Angiography(DSA) and MR Angiography(MRA) (Slice Interpolation기법의 고해상도 자기공명혈관조영술을 이용한 뇌동맥류의 진단 : 디지탈 감산 혈관조영술과 자기공명 혈관조영술의 비교)

  • ;;;Daisy Chien;Gerhard Laub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.94-102
    • /
    • 1997
  • Purpose: There have been some efforts to diagnose intracranial aneurysm through a non-invasive method using MRA, although the process may be difficult when the lesion is less than 3mm. The present study prospectively compares the results of high resolution, fast speed slice interpolation MRA and DSA thereby examing the potentiality of primary non-invasive screening test. Materials and Methods: A total of 26 cerebral aneurysm lesions from 14 patients with subarachnoid hemorrhage from ruptured aneurysm (RA) and 5 patients with unruptured aneurysm(UA). In all subjects, MRA was taken to confirm the vessel of origin, definition of aneurysm neck and the relationship of the aneurysm to nearby small vessels, and the results were compared with the results of DSA. The images were obtained with 1.5T superconductive machine (Vision, Siemens, Erlangen, Germany) on 4 slabs of MRA using slice interpolation. The settings include TR/TE/FA=30/6.4/25, matrix $160{\times}512$, FOV $150{\times}200$, 7minutes 42 seconds of scan time, effective thickness of 0.7 mm and an entire thickness of 102. 2mm. The images included structures from foramen magnum to A3 portion of anterior cerebral artery. MIP was used for the image analysis, and multiplanar reconstruction (MPR) technique was used in cases of intracranial aneurysm. Results: A total of 26 intracranial aneurysm lesions from 19 patients with 2 patients having 3 lesion, 3 patients having 2 lesions and the rest of 14 patients having 1 lesion each were examined. Among those, 14 were RA and 12 were UA. Eight lesions were less than 2mm in size, 9 lesions were 3-5mm, 7 were 6-9mm and 2 were larger than IOmm. On initial exams, 25 out of 26 aneurysm lesions were detected in either MRA or DSA showing 96% sensitivity. Specificity cannot be estimated since there was no true negative of false positive findings. When MRA and MPR were used concurrently for the confirmation of size and shape, the results were equivalent to those of DSA, while in the confirmation of aneurysm neck and parent vessels, the concurrent use of MRA and MPR was far superior to the sole use of either MRA or DSA. Conclusion: High resolution MRA using slice interpolation technique showed equal results as those of DSA for the detection of intracranial aneurysm, and may be used as a primary non-invasive screening test in the future.

  • PDF

Studies on Marine Sediments of the Korean Seas. I. Concentrations and Distributions of Some Ceochemical Elements in Sediments from the Sea off Eastern Korea (한국근해의 해저토에 관한 연구 I. 동해 해저토의 지화학적 성분의 함량과 분포)

  • Choe, Sang
    • 한국해양학회지
    • /
    • v.1
    • /
    • pp.1-15
    • /
    • 1971
  • Some major and minor geochemical contents, such as Zr, Br, Ni, Sr, Zn, Mn, Ti and Fe, of ninety-seven sediment samples from the sea off eastern Korea have been analyzed by the fluorescence spectrometric techniques. Concentrations of elements showed 22-962ppm Zr(averaging 194.4ppm), tr-220 ppm Br(averaging 138.2ppm), 31-141ppm Ni(averaging 89.1ppm), 118-3,494ppm Sr(averaging 448.6ppm) 27-134ppm Zn(averaging 92.5ppm), 38-1,043ppm Mn(averaging 664.2ppm), 0.04-0.42% Ti(averaging 0.29%) and 0.57-4.02% Fe(averaging 2.76%). The ratios of Zn/Ti 10$\^$3/, An/Fe 10$\^$3/ and Ti/Fe were 0.27-6.43(averaging 3.27), 2.25-7.76 (averaging 3.46) and 0.04-0.18(averaging 0.11), respectively. From the results of geochemical analyses of sediments from the sea off eastern Korea represented the different types of sediment pattern are considered between the southern part and the northern part of the sea. The bottom sediments of the southern part were characterized with higher Sr and lower Zn, Br contents; higher Zr and lower Br contents; lower Br and lower Zn, Ti and Fe contents; and lower Zn and lower Ti and Fe contents.

  • PDF

Design of Built-In-Self-Repair Circuit for Embedded Memory Using 2-D Spare Memory (2차원 여분 메모리를 이용한 내장메모리의 자가치유회로 설계)

  • Choi, Ho-Yong;Seo, Jung-Il;Cha, Sang-Rok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.12
    • /
    • pp.54-60
    • /
    • 2007
  • This paper proposes a built-in-self-repair (BISR) structure using 2-dimensional spare memory to effectively self-repair faults of an embedded memory. In case of multiple faults in the same row (column) of an embedded memory, the previous method using 1-D spare column (row) memory needs the same number of spare memory columns (rows) as the number of faults to self-repair them. while the new method using 2-D spare memory needs only one spare row (column) to self-repair them. Also, the virtual divided memory is adopted to be able to self-repair using not a full spare column memory but the only partial spare column memory corresponding to the faults. A self-repair circuit with $64\times1-bit$ core memory and $2\times8$ 2-D spare memory is designed. And the circuit includes a built-in-self-test block using the 13N March algorithm. The circuit has been implemented using the $0.25{\mu}m$ MagnaChip CMOS process and has $1.1\times0.7mm^2$ chip area with 10,658 transistors.