A Study on the Characterization of Size Distributions and Atmospheric Dry Deposition of Heavy Metals (대기중 중금속 입자의 입경분포 및 건식침적 특성에 관한 연구)

  • Yi, Seung-Muk;Lee, Eun-Young;Cheong, Jang-Pyo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.3
    • /
    • pp.575-585
    • /
    • 2000
  • Mass and elemental dry deposition fluxes and ambient particle size distributions were measured using dry deposition plates, a cascade impactor. and a CPS(Coarse Particle Sampler), from July to November 1998 in Seoul. Korea. Primarily anthropogenic elemental fluxes (Cu, Mn, Ni, Pb, Zn) were on average one to two orders of magnitude lower than primarily crustal elements (Al, Ca). Complete total and elemental particle size distributions showed trimodal size distributions due to the peak in particles larger than $10{\mu}m$ in diameter. A multi-step model and the Sehmel-Hodgson model were used to calculate total and cumulative deposition fluxes. The result indicated that dry deposition fluxes were extremely sensitive to the mass of particles larger than $10{\mu}m$ in diameter due to their high dry deposition velocities. The result showed that particles larger than $10{\mu}m$ in diameter dominated atmospheric dry deposition. The modeled fluxes calculated using the measured atmospheric particle size distributions and modeled deposition velocities were compared to measured ones. In general, the measured mass and elemental fluxes agreed well with the modeled ones.

  • PDF

Evaluation of Surface water-Groundwater Interaction for the Kap-Stream Basin (갑천 유역의 지표수-지하수 상호작용 평가)

  • Hong, Sung-Hun;Kim, Jeong-Kon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.503-507
    • /
    • 2007
  • 지하수 유동 모델에 반영되는 유역의 수리지질학적, 수문학적 특징들은 지하수 유동 특성에 주요한 영향을 미칠 수 있는 현장 특성들이다. 상기 특징들을 최대한 반영하기 위하여 438개의 관정자료를 토대로 갑천 유역(유역 면적 $648.3km^2$)의 대수층 구조 특성을 분석하고, 24개의 하천 자료를 이용하여 지하수 유동 모델을 구축하였다. 그리고 검 보정된 준분포형 유출모형(SWAT)의 22개 소유역의 지하수 함양량 결과를 3차원 지하수 유동 모델(MODFLOW)과 연계하여 갑천 유역의 광역 지하수 유동 특성을 평가하였다. 모의된 지하수위와 86개 지하수 관측정의 지하수위 비교에서 결정계수는 0.9918, 유역 전체의 물교환량의 상대오차율이 약 0.57%로 갑천 유역의 지하수 유동 특성을 잘 반영하였다. 갑천 유역의 지하수는 지형 및 대수층 특성과 하천의 영향에 의하여 전반적으로 유역 남쪽에서 북쪽으로 유동하는데 산지 지역에 존재하는 하천들은 손실과 이득 하천의 형태를 반복하는 반면, 갑천 중 하류 부분과 갑천-유등천 합류 부근은 이득하천의 형태를 보이고 있다. 그리고 소유역별 지하수 물교환량 분석한 결과, 상기 지역을 포함하는 소유역의 하천 공급원이 해당 유역의 지하수 함양량보다 지하수 유동 체계에 따라 인근 소유역에서 공급되는 지하수 유입량 비율이 훨씬 높은 것으로 분석되었다. 반면 유등천 중 상류 지역의 소유역을 제외한 산지 지역의 경우는 하천 공급원이 지하수 유동 체계에 의한 유입량보다 해당 유역 내에서 공급되는 지하수 함양량 비율이 높은 것으로 분석되었다. 따라서 지표수와 지하수의 상호작용 및 하천 유출에 지하수 유동 특성이 주요한 영향을 미치는 것으로 평가되었다.ens 4.4% (2.19)로 나타났다. 4. 全모기類의 月別 捕獲個體數에 對한 百分率은 다음과 같다. 5月 : 0.1% (1981年), 0.0% (1982年); 6月 : 3.5%, 1.3%; 7月 : 50.0%, 33.9%; 8月 : 37.1%, 52.1%; 9月 : 8.8%, 11.9%; 10月 : 0.5%, 0.8%; 11月 : 0.1%. 5. 모기類의 出現은 1981年과 1982年 모두 5月初로서 共通性을 지니고 있으나 增加勢를 보이는 것은 다르게 나타났다. 즉, 1981年은 6月 첫째 週이고 1982年은 前年度보다 3週 앞당겨진 5月 둘째 週였다. 6. 發生最大 peak는 1981年이 7月 다섯째 週이고, 1982年은 2週가 늦은 8月 둘째 週였다. 7. Culex (Culex) pipiens pallens의 最大發生 peak는 1981年度에 7月 다섯째 週, 1982年度는 2週 앞당겨진 7月 셋째 週였다. 8. Culex (Culex) tritaeniorhynchus summoro년의 最大發生 peak는 1981年, 1982年 모두 8月 둘째 週였다. 9. Anopheles (Anopheles) sinensis의 最大發生 peak는 1981年에 7月 다섯째 週, 1982年은 2週 앞당겨진 7月 셋째 週였다. 10. 重要 3種의 最大 peak를 比城하면 Culex (Culex) pipiens pallens와 Anopheles (Anopheles) sinensis는 1981年과 1982年 모두 最大 peak時期가 同一하였으며, Culex (Culex) tritaeniorhynchus summoro년는 2年間 모두 8月둘째 週에 나타났다.osterior to manubrium and anterio

  • PDF

Evaluation of Groundwater Flow for the Kap-cheon Basin (갑천 유역의 지하수 유동 평가)

  • Hong, Sung-Hun;Kim, Jeong-Kon
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.6 s.179
    • /
    • pp.431-446
    • /
    • 2007
  • Groundwater flow in a basin is greatly affected by many hydrogeological and hydrological characteristics of the basin. A groundwater flow model for the Kap-cheon basin ($area=648.3km^2$) in the Geum river basin was established using MODFLOW by fully considering major features obtained from observed data of 438 wells and 24 streams. Furthermore, spatial groundwater recharge distribution was estimated employing accurately calibrated watershed model developed using SWAT, a physically semi-distributed hydrological model. Model calibration using observed groundwater head data at 86 observation wells yielded the deterministic coefficient of 0.99 and the water budget discrepancy of 0.57%, indicating that the model well represented the regional groundwater flow in the Kap-cheon basin. Model simulation results showed that groundwater flow in the basin was strongly influenced by such factors as topological features, aquifer characteristics and streams. The streams in mountainous areas were found to alternate gaining and losing steams, while the streams in the vicinity of the mid-stream and down-stream, especially near the junction of Kap-cheon and Yudeong-cheon, areas were mostly appeared as gaining streams. Analysis of water budget showed that streams in mountainous areas except for the mid-stream and up-stream of Yudeong-cheon were mostly fed by groundwater recharge while the streams in the mid and down-stream areas were supplied from groundwater inflows from adjacent sub-basins. Hence, it was concluded that the interactions between surface water-groundwater in the Kap-cheon basin would be strongly inter-connected with not only streams but also groundwater flow system itself.

A Feasibility study on the Simplified Two Source Model for Relative Electron Output Factor of Irregular Block Shape (단순화 이선원 모델을 이용한 전자선 선량율 계산 알고리듬에 관한 예비적 연구)

  • 고영은;이병용;조병철;안승도;김종훈;이상욱;최은경
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.21-26
    • /
    • 2002
  • A practical calculation algorithm which calculates the relative output factor(ROF) for irregular shaped electron field has been developed and evaluated the accuracy of the algorithm. The algorithm adapted two-source model, which assumes that the electron dose can be express as sum of the primary source component and the scattered component from the shielding block. Original two-source model has been modified in order to make the algorithm simpler and to reduce the number of parameters needed in the calculation, while the calculation error remains within clinical tolerance range. The primary source is assumed to have Gaussian distribution, while the scattered component follows the inverse square law. Depth and angular dependency of the primary and the scattered are ignored ROF can be calculated with three parameters such as, the effective source distance, the variance of primary source, and the scattering power of the block. The coefficients are obtained from the square shaped-block measurements and the algorithm is confirmed from the rectangular or irregular shaped-fields used in the clinic. The results showed less than 1.0 % difference between the calculation and measurements for most cases. None of cases which have bigger than 2.1 % have been found. By improving the algorithm for the aperture region which shows the largest error, the algorithm could be practically used in the clinic, since one can acquire the 1011 parameter's with minimum measurements(5∼6 measurements per cones) and generates accurate results within the clinically acceptable range.

  • PDF

Computational Fluid Dynamic Modeling for Internal Antenna Type Inductively Coupled Plasma Systems (CFD를 이용한 내장형 안테나 유도 결합 플라즈마 시스템 모델링)

  • Joo, Jung-Hoon
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.3
    • /
    • pp.164-175
    • /
    • 2009
  • CFD is used to analyze gas flow characteristics, power absorption, electron temperature, electron density and chemical species profile of an internal antenna type inductively coupled plasma system. An optimized grid generation technology is used for a complex real-scale models for industry. A bare metal antenna shows concentrated power absorption around rf a feeding line. Skin depth of power absorption for a system is modeled to 50 mm, which is reported 53 mm by experiments. For an application of bipolar plates for hydrogen fuel cells, multi-sheet loading ICP nitriding system is proposed using an internal ICP antenna. It shows higher atomic nitrogen density than reported simple pulsed dc nitriding systems. Minimum gap between sheets for uniform nitriding is modeled to be 39 mm.

Suggestion of an experimental method for optimization of flange point of a bolt-clamped Langevin-type ultrasonic transducer (볼트 체결형 란주반 초음파 트랜스듀서의 프렌지 포인트 최적화를 위한 실험적 방법 제안)

  • Kim, Jungsoon;Kim, Haeun;Kim, Moojoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.4
    • /
    • pp.270-277
    • /
    • 2021
  • In the power ultrasound fields, the flange position for fixing the transducer is an important factor influencing on electro-mechanical efficiency of the transducer. We suggested a practical method that can determine the installation position of the flange for different resonance modes of the bolt-clamped type Langevin ultrasonic transducer. A semicircular wedge-shaped jig was manufactured and moved along the lateral surface of the transducer. The vibration characteristics were examined after a constant pressure was applied to the semicircular wedge-shaped jig. By observing the change of the input admittance of the transducer depending on the position of the pressure application, the optimum position for the flange installation could be determined. The resonant modes of the transducer were calculated by a Mason's equivalent circuit, and the particle velocity distribution for each resonance mode was calculated by a transmission line model. Since the optimum positions determined from an experimental result show a good correspondence with the node positions of the vibration modes calculated by the transmission line model, the validity of the suggested method was verified.

3X3 봉다발에서의 국소 열전달에 관한 실험적 연구

  • 정장환;정문기;유성연
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.356-361
    • /
    • 1996
  • 물질전달과 열전달의 유사성을 이용하는 나프탈렌 승화법을 핵연료집합체 모델에 적용하여 봉다발에서의 국소 열전달 계수의 분포를 측정하였다. 실험 모델은 가압경수형 원자로에서 나타나는 부수로 즉, 벽면 부수로와 모서리 부수로 및 내부 부수로로 구성되는 3$\times$3 봉다발이다. 봉다발에서의 국소 열전달 계수 값은 부수로의 형상과 인접한 봉 및 벽면의 영향이 크게 작용하는 것으로 측정되었다. 내부 부수로에 둘러져 있는 봉에서의 국소 열전달계수값은 봉과 봉 사이에서는 부수로 중심 방향보다 낮았고, 평균열전달계수는 Dittus-Boelter의 상관식보다 약간 낮은 값을 보였다. 벽면 부수로에 인접한 봉에서의 열전달계수는 벽면의 영향으로 내부 부수로에 있는 봉보다 상대적으로 낮았으며, 모서리 부수로의 봉에서는 벽면의 영향이 증대되어 더욱 낮게 나타났다.

  • PDF

액막의 유동 및 온도계산 모델에 의한 PCCS 열전달 현상 해석

  • 김성오;황영동;김영인;배윤영;장문희
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.584-589
    • /
    • 1998
  • 범용 전산유체 해석코드인 CFX 4.1을 사용하여 철재격납용기 표면을 전열면으로 이용하는 피동격납용기냉각계통에 대한 열전달 현상해석을 수행하였다. 철재격납용기 내부와 외부 채널에서 발생하는 열전달 현상을 모사하기 위하여 액막의 유동 및 온도계산 모델을 범용 전산유체해석코드인 CFX4.1에 적용하여 철재격납용기 내.외부의 표면을 흐르는 액막의 높이, 액막내 온도분포, 철재격납용기 내.외부의 온도, 유속 및 부피분율 등을 계산하는 복합 열전달 해석 방법론을 개발하였다. 해석결과는 향후 실험 둥을 통한 검증이 필요하나 피동형 격납용기템각계통에서 발생하는 물리적 현상들의 복합적인 거동 분석에 사용될 수 있는 것으로 평가되었다.

  • PDF

TRAC-PF1을 이용한 FLECHT-SEASET 평가계산

  • 이재훈;최동수;이걸우;황태석;박병서;조창석
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.627-632
    • /
    • 1997
  • FLECHT-SEASET 실험을 이용하여 냉각재상실사고시 Reflood에 대한 TRAC-PF1 전산코드의 예측 능력을 평가하였다. FLECHT-SEASET 실험 장치는 3.657m(12 ft) 높이 161개 전열 봉으로 이루어 져 있으며, 다양한 재관수율, 계통압력, 초기 피복재온도, 재관수온도 노심내 반경방향 출력분포 둥의 조건에 따라 수행된 실험이다. TRAC-PF1은 비균질 비평형 이상유동 열수력(Nonhomogeneous Non-equilibrium Two-Fluid Hydrodynamic)모델을 사용하고 원자로 압력용기는 3차원으로 모델할 수 있는 최적전산코드로서, 이 평가 계산에는 HP Version이 사용되었다. 본 연구에서는 재관수율 변화에 따라 달라지는 연료봉 최대 피복재온도와 Quench 시간에 대한 TRAC-PF1 전산코드의 예측 능력을 중점적으로 평가하였다. 계산 결과 TRAC-PF1은 최대 피복재온도는 약 20-100$^{\circ}$K 낮게, Quench 시간은 실험치와 비교하여 약 40-150초 정도 늦게 예측하는 것으로 나타났는데, 재관수율이 낮을수록 최대피복재 온도는 낮게, Quench 시간은 늦게 예측하는 경향을 보이고 있다. 또한 재관수율이 3 in/sec 이상에서 노심 상부가 일찍 Quenching 되는 것으로 계산되는데, 이는 노심상부 열전달 Regime의 부적절한 계산이 원인으로 보인다.

  • PDF

An intelligent sun tracker with self sensor diagonosis system (자기 센서진단기능을 가진 지능형 태양추적장치)

  • 최현석;현웅근
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.452-456
    • /
    • 2002
  • The sensor based control system has some sensor fault while operating in the field. In this paper, a sensor fault detection and reconstruction system for a sun tracking controller has been researched by using polynomial regression and principle component analysis approach. The developed sun tracking system controls tow actuators with sensor based mechanism as on-line control and sun orbit information as off-line control, alternatively. To show the validity of the developed system, several experiments were illustrated.

  • PDF