• Title/Summary/Keyword: 분진 농도

Search Result 235, Processing Time 0.026 seconds

The Impacts of Barley Straw Burning Having Different Moisture Contents and Harvesting Timing on Air Pollutant Emission (보릿짚의 수분함량 및 수확시기가 소각시 대기오염물질 발생에 미치는 영향)

  • Ko, Jee-Yeon;Kang, Hang-Won;Lee, Jae-Sang;Kim, Chun-Song;Park, Seong-Tae;Kim, Bok-Jin
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.2
    • /
    • pp.99-103
    • /
    • 2004
  • This study was carried out to determine impacts of burning of barley straw produced from rice-barley double cropping paddy field on air quality by investigating emissions of greenhouse gases ($CO_2$, $CH_4$ and $N_2O$), air pollution gases (CO, $SO_2$, $H_2S$, $NH_3$ and NO) and particulate matters (PM 10 and PM 2.5). When the barley straw at a rate of 4.5 t/ha was burned at open status, the emitted GHGs amounts were $CO_2$ 376.8 kg/l0a, $CH_4$ 1.56 and $N_2O$ 0.06. The amount of CO emission was the largest among air pollution gases. These results showed that the range of $45{\sim}55%$ of total C in barley straw was emitted as $CO_2-C$, followed by CO-C ($6.4{\sim}5.9%$) and $CH_4-C$ ($0.5{\sim}0.7%$). As far as moisture content in barley straw is concerned, the higher moisture content that the barley straw contains, the larger amount of air pollution gases and the higher portion of PM 2.5 in PM 10 were emitted when it burned. In case of harvesting time of barley straw, emission amounts of greenhouse, air pollution gases and PM 2.5 portion in PM 10 had tendency to increase when earlier harvested barley straw was burned.

A study on Coal Water Mixture production using various mill method (석탄 분쇄방법에 따른 CWM 제조 특성연구)

  • Ra, Howon;Choi, Young Chan;Lee, Dongwook;Hong, Jaechang;Bae, Jongsoo;Park, Sejun;Lee, Youngju
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.78.1-78.1
    • /
    • 2011
  • 분포지역과 매장량이 한정되어 있는 석유에 비하여 석탄은 가채년수가 길고 세계 전역에 널리 분포되어 있으므로 향후 안정적인 에너지 공급으로 각광받고 있다. 석탄을 이용하여 CWM을 제조하는 기술은 석유에 비하여 저장, 수송, 분진 비산등의 문제점을 개선하여 위하여 1980년대부터 석탄 물 혼 합연료(Coal-Water Mixture)의 기술개발을 위한 연구가 진행되었다. 이는 미분탄(유연탄)에 30%정도의 물과 약간의 첨가제를 혼합하여 유체화하여 수송성은 액체연료와 같고 연소성은 석탄의 성상을 갖는 특징을 가지게 된다. 본 연구에서는 당센터에서 보유하고 있는 습식 분류층 가스화장치에 적용하기 위한 CWM(Coal Water Mixture)제조 특성을 연구하였다. 습식 석탄 가스화기에 사용되는 CWM은 미분되어진 석탄과 물, 첨가제를 일정비율로 혼합하여 사용하게 된다. 이때 공급되어지는 미분의 입도와 분쇄 형태에 따른 입자 형태, 입자의 분포에 따라서 CWM의 특성이 각각 다르게 나타나게 된다. 이때 만들어진 CWM의 농도와 점도 특성에 따라서 버너의 성능 및 가스화기 운전 조건등에 많은 영향을 미치게 된다. 습식 석탄 가스화에 적용된 예정인 대상탄을 대상으로 하여 석탄분쇄 형태에 따른 CWM의 제조 특성을 실험하였다.

  • PDF

Respirable Cool Dust Exposure Concentration at Work Sites of Underground Coal Mines in Taebaek Area (태백지역 석탄광산의 작업부서별 호흡성 분진 폭로농도)

  • Yoon, Young No;Chung, Ho Keun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.1
    • /
    • pp.47-55
    • /
    • 1991
  • Exposure level of respirable coal dust of underground coal mines in Taebaek area was evaluated. Personal air samplers with 10-mm nylone cyclones were attached to the coal workers including drillers, coal cutters, their assistants, haulers, and separators. Log-normality of respirable dust exposure concentration were tested by Kolmogorov-Smirnov one-sample test. Differences of means of respirable dust exposure concentration between work sites were tested by one-way ANOVA test and multiple comparison(Scheffe) test. And differences of respirable dust exposure concentration of principal and assistant workers in drilling sites and in coal faces were tested by paired t-test. Relation of respirable dust exposure concentration for the principal workers and their assistants in drilling sites and in coal faces were tested by regression analysis. The results were as follows : 1. All of the respirable dust concentration were log-normally distributed. 2. There were not only significantly different means of exposure concentration between drillers and coal cutters but between coal cutters and haulers. 3. Means of exposure concentration of drillers and drilling assistants were not significantly different. And means of exposure concentration of coal cutters and coal cutting assistants were not different.

  • PDF

Development of Test Method for Flat Panel Display Life Time Prediction during Atmospheric Particle Exposure (평판디스플레이의 대기중 분진농도에 따른 수명예측 시험방법 개발)

  • Yoo, Dong-Hyun;Lee, Gun-Ho;Choi, Jung-Uk;Ahn, Kang-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.4
    • /
    • pp.45-48
    • /
    • 2013
  • The electronic device, such as flat panel display (FPD), is very important in our life as a means of communication between humans. Liquid crystal display (LCD), which is categorized as a flat panel display, has been used in many display products, especially in TV industry. An LED TV is composed of several electrical components, such as liquid critical module (LCM), analog to digital convertor (AD), power supplier, and inverter board. These modules are very vulnerable to particulate contamination, and causing malfunction or visibility degradation. In this study, we developed a test method for prediction of LCM's lifetime. The test system consists of carbon particle generation flame, dilution system, test chamber, and particle concentration monitoring instrument. Since the carbon particles are the most abundant in the atmosphere and easily absorb light, soot particles are used as a challenging material for this test. The concentration of generated soot particles is set around 4,000,000 #/cc, which is 400 times higher than that of usual atmospheric particles. Through this experiment, we deduced the relationship between the dust concentration and life time of the test specimen.

A Study on Airborne Coal Dust Concentration at each Work Site in Coal Briquet Factory (연탄제조 공장의 작업장별 석탄분진의 농도에 관한 연구)

  • 신대윤;오정룡;강공언
    • Journal of Environmental Health Sciences
    • /
    • v.18 no.1
    • /
    • pp.6-11
    • /
    • 1992
  • This study was carried out to investigate exposure level, size distribution, and respirable mass fraction of airborne coal dust and heavy metal concentration of respirable coal dust at each work site in coal briquet factory from July 1991 to September 1991. Geometric mean of total dust concentration was 10.88mg/m$^{3}$ at storage shop, 8.22mg/m$^{3}$ at pulverize shop, and 3.79mg/m$^{3}$ at rotary press shop, respectively, but those at storage and pulverize shop were higher than TLV. Geometric mean of respirable coal dust concentration wat 1.03mg/m$^{3}$ at storage shop, 0.78mg/m$^{3}$ at pulverize shop, and 0.55mg/m$^{3}$ at rotary press shop, respectively, which were lower than TLV Aerodynamic 50% cutoff diameter of the suspended coal dust was 5$\mu$m at rotary press shop and 6.8$\mu$m at storage shop, ranged to thoracic particulate defined by ACGIH, and deposited in the region of repiratory system. The mass fraction rate of respirable dust to the total coal dust was 26.2% at rotary press shop, 18.8% at storage shop, and 13.8% at pulverize shop, respectively. Heavy metal concentrations of the respirable coal dust were 0.028mg/m$^{3}$ ib Fe, 0.0081mg/m$^{3}$ in Cu, and 0.0039mg/m$^{3}$ in Pb.

  • PDF

Characteristic Analysis of the Surface Concentration Distribution under the Influence of Particle Settling by Lagrangian Model (Lagrangian 모형에 의한 분진 침강 효과에 따른 지표면 농도의 분포특성 분석)

  • Park, I.S.;Kang, I.G.;Choi, K.D.
    • Journal of Environmental Impact Assessment
    • /
    • v.2 no.1
    • /
    • pp.57-63
    • /
    • 1993
  • An analysis for particle settling effects via of plume centerline tilted exponentially under the influence of panicle settling velocity is carried out for particle of $30{\mu}m$ diameter with $1g/cm^3$ density and 0.02m/s settling velocity corresponding to its particle characteristic according to various wind speeds, atmospheric stabilities. Characteristic analysis of surface concentration distribution simulated by Lagrangian model also are carried out under the influence of plume centerline tilted exponentially at 10m stack height emitted 200 particles per second. This study reveals that plume centerline at the nearby source is sharply tilted exponentially under the condition of stable, weakly wind speed, therefore the lower concentration at the nearby source, the higher concentration at the downwind distance far away from source than actual one is brought out, if not apply the effect of plume centerline tilted exponentially to diffusion Model.

  • PDF

Particle Size-Related Dust and Quartz Concentration of Stone Grinding Operations (석재가공 공정에서 발생되는 분진과 석영의 입자크기별 농도 특성)

  • Kim, Seong-Hwan;Bae, Hye Jeong;Jung, Jong-Hyon;Phee, Young Gyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.462-470
    • /
    • 2014
  • Objectives: The purpose of this study was to evaluate quartz concentrations in airborne respirable dust and particle size-related quartz concentrations. Methods: Respirable dust samples were collected using a 10 mm Dorr-Oliver nylon cyclone equipped with a 37 mm, $5{\mu}m$ pore size PVC filter. Dust samples were collected with a Marple's personal cascade impactor from stone grinding operations in five stone-related business located in the Gyeongsangbuk-do area. Results: The geometric mean of quartz concentration in the respirable dust was $0.170mg/m^3$, and the rate of exceeding the Korean Occupational Exposure Limit(KOEL) was 93.3%. The quartz concentration by particle size shows that it was the highest($0.115mg/m^3$) in stage 5($3.50-6.00{\mu}m$), which corresponds with the size of respirable particle. The smaller the particle sizes were, the higher quartz the content became. The mass fractions of inhalable, thoracic, and respirable dust were 72.1%, 36.0%, and 14.4%. Conclusions: The rate of the quartz concentration in respirable dust from stone grinding operations exceeding the American Conference of Governmental Industrial Hygienists Threshold Limit Values was 100%, which means proper work environmental management is required through regular working environmental measurements. Given that the stone grinding operations had a higher small size dust concentrations, there is a need to reduce respirable dust, such as through wet operation and local exhaust ventilation.

Dust Collection Efficiency, Inhalation Pressure, and CO2 Concentration in Health Masks (보건용 마스크의 분진포집효율, 흡기저항 및 CO2 농도)

  • Han, Don-Hee;Kim, Il Soon
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.1
    • /
    • pp.78-87
    • /
    • 2020
  • Objectives: To identify the degree of physical burden, a determination was undertaken of dust collection efficiency, inhalation pressure, and CO2 concentration related to health masks certified by the Ministry of Food and Drug Safety (MFDS). Methods: Twenty health masks were purchased on the market. Dust collection efficiency and inhalation pressure were determined in the same manner as in MFDS certification testing, respectively using TSI Model 8130 (TSI, U.S.) and ART Plus (Korea). CO2 concentrations for 20 subjects using a CO2 analyzer (G100, G150, Geotechnical Instrument Ltd., UK) were measured with a similar method as a total inward leakage test. In addition to CO2 levels, dead space volumes in the masks was determined for predicting concentrations of CO2 in inhalation air. Results: Most of the dust collection efficiencies found for the 20 masks were far higher than the standard. Four KF94s met KF99 and four KF80s even met KF94. Most inhalation pressures were also much lower than the standard, with many almost one-half of the standard. The mean and standard deviation of CO2 concentration in the mask were 2.9±0.44%. Considering dead volume, the prediction for CO2 concentration in the inhalation air was 4,395±1,266 ppm. Conclusions: For healthy men and women, the dust collection efficiency and inhalation pressure of health masks were not at a level that would affect their health. Although CO2 levels in the inhalation air were predicted not to affect health, research on the physiological effects of health masks on Koreans is needed for more precise research.

A Comparison of Cotton Dust Concentrations Measured by Three Dust Samplers (시료채취방법에 따른 면분진의 공기 중 농도 비교)

  • Phee, Young-Gyu;Kim, Hyun-Wook;Byeon, Sang-Hoon
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.5
    • /
    • pp.386-392
    • /
    • 2009
  • This study was undertaken to compare the performance of three dust samplers for collecting cotton dust fibers. For this study, three dust samplers including Vertical Elutriator (VE), Total Dust Method (TDM) using 37 mm cassette, and the Institute of Occupational Medicine (IOM) sampler were selected. A total of 6 cotton mills and 4 towel factories were investigated. When measured by VE, the GM for cotton dust was 0.19 $mg/m^3$ which was less than the current occupational exposure limit (OEL) 0.2 $mg/m^3$. But when measured by TDM and IOM at the same locations, the GMs were 0.37 and 0.63 $mg/m^3$, respectively. In Korea, most industrial hygienists have used the TDM for cotton dust measurements and the results were compared with either the TLV for cotton dust or the PNOC (particulates not otherwise classified) of 10 $mg/m^3$ for making decisions. The results of this study clearly showed that past cotton dust measurements and decisions made with such results were not correct. It needs to be noticed the related contents by using VE if it applies to the exposure limit, 0.2 $mg/m^3$, and needs to be revised the exposure limit by IOM. Also, if TDM is used, it requires to be studied and suggested to the new OEL.

Leaching behavior of rhenium and molybdenum from molybdenite roasting dust in NaOH solutions (휘수연석(輝水鉛石)의 배소(焙燒) 중 발생한 분경(粉慶)으로부터 NaOH에 의한 Rhenium과 Molybdenum의 침출(浸出))

  • Kim, Young-Uk;Kang, Jin-Gu;Sohn, Jeong-Soo;Cho, Bong-Gyu;Shin, Shun-Myung
    • Resources Recycling
    • /
    • v.18 no.5
    • /
    • pp.37-43
    • /
    • 2009
  • The demand for rhenium has considerably increased recently owing to the large-scale consumption in industries and the price of rhenium has increased owing to the lack of supply and its availability. The dust from the roasting of molybdenite was employed to investigate the leaching behavior of rhenium and molybdenum. Leaching experiments were done by varying optimum parameters, such as reaction time, NaOH concentration and leaching temperature. The optimum leaching condition was found to be $4\;mol{\cdot}L^{-1}$ NaOH, 2 hours leaching time, $100\;g{\cdot}L^{-1}$ solid/liquid ratio, $80^{\circ}C$ temperature, and 250 rpm. At this condition, leaching percentage of rhenium and molybdenum was 86.1% and 88.6%, respectively.