• Title/Summary/Keyword: 분자검출

Search Result 476, Processing Time 0.023 seconds

Investigation of fish community structure and species diversity in two river estuary ecosystems, the Taehwa River and Changwon Stream, based on conventional survey and eDNA metabarcoding (어구조사 및 환경 DNA 메타바코딩을 이용한 태화강, 창원천 하구 생태계의 어류 군집 구조 및 종 다양성 평가)

  • Hee-kyu Choi;Yu Rim Kim;Soon Young Hwang;Yeounsu Chu;Pyoungbeom Kim;Hyuk Je Lee
    • Korean Journal of Environmental Biology
    • /
    • v.41 no.4
    • /
    • pp.637-656
    • /
    • 2023
  • River estuaries are dynamic and productive ecosystems with high regional biodiversity. Environmental DNA (eDNA) has become a useful approach to assessing biodiversity in aquatic ecosystems. This study was conducted to investigate fish community characteristics and species diversity in two river estuary ecosystems, the Taehwa River and Changwon Stream. We further compared conventional and eDNA metabarcoding analyses of the fish communities. The conventional survey was performed in May, July, and October 2022, while the eDNA analysis was conducted only in May. We observed various fish species with different life histories, including carp, goby, and marine fish. We also found that migratory fish, such as dace Tribolodon hakonensis, sweetfish Plecoglossus altivelis, and eel Auguilla japonica, occurred in the Taehwa River, suggesting high river connectivity. Marine fish species were predominant in the Changwon Stream, as this river is located close to the sea. The diversity indices showed that the Taehwa River generally had higher species richness, evenness, and diversity values than the Changwon Stream. A total of 9-19 species were detected in the conventional survey for the three sites, whereas 11-18 species were found from eDNA analysis. The findings indicate that the sensitivity of eDNA was similar to or higher than that of the conventional method. Our study findings suggest the efficiency and efficacy of eDNA-based fish community monitoring, although with some shortcomings in applying the genetic marker to Korean fish, including no clear-cut distinction for Korean endemic species and/or genetically closely related species groups.

Hall 소자용 InAs 박막성장

  • 김성만;임재영;이철로;노삼규;신장규;권영수;유연희;김영진
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.94-94
    • /
    • 1999
  • 반도체 Hall 효과를 이용하여 자계를 검출하여 이를 전압신호로 출력하는 자기센서로는 주로 GaAs, InSb, InAs 등의 박막이 사용되고 있다. 자기센서의 응용분야가 최근에는 직류전류의 무접촉 검출, 자동차의 무접촉 회전 검출, 산업용 기계의 제어용 무접촉 위치검출 분야로 확대되고 있어 그 수요가 급증하고 있다. 이중 Hall 소자의 응용분야중 많은 활용이 기대되고 있는 자동차용 무접촉 센서는 -4$0^{\circ}C$~15$0^{\circ}C$의 온도범위에서 안정하게 작동하여야 하므로 온도 안정성이 매우 중요하다. 그러나 Hall 소자 시장의 80%를 점유하고 있는 InSb Hall 소자는 온도가 올라감에 따라 저항이 급격히 낮아지는 성질을 가지고 있으므로 10$0^{\circ}C$ 이상의 온도에서 사용하는 것이 불가능하다. 한편 InAs(에너지갭~0.18eV)는 InSb보다 에너지 갭이 크므로 고온에서도 작동이 가능하고 자계변화에 따른 출력의 직진성이 매우 좋다는 장점을 가지고 있다. 이러한 InAs Hall 소자를 실현하기 위해서 가장 중요한 것이 고품위의 InAs의 박막 성장기술이다. InAs 박막을 성장하기 위해서 사용되고 있는 기판은 GaAs이다. 그러나 GaAs 기판과 InAs 박막 사이에는 약 7% 정도의 격자부정합이 존재하기 때문에 높은 이동도를 가지는 고품위 박막을 성장시키기가 매우 어렵다. 이에 본 연구에서는 분자선에피택시 방법을 이용하여 GaAs 기판위에 고품위의 InAs 박막을 성장하는 기술을 연구하였으며, 성장된 InAs 박막의 특성을 DCX 및 Hall effect 등으로 조사하였다. InAs 박막 성장시 기판은 <0-1-1> 방향으로 2$^{\circ}$ off 된 GaAs(100)를 사용하였다. InAs 박막성장시 기판온도는 48$0^{\circ}C$로 하고 GaAs buffer 두께는 2000$\AA$로 하여 As flux 및 Si doping 농도등을 변화시켰다. 그 결과 Si doping 농도 2.21$\times$1017/am에서 10,952cm2/V.s의 이동도를 얻었다.

  • PDF

Virulence Genes of Staphylococcus aureus Isolated in Daegu and Gyeongsangbuk-do Areas (대구광역시와 경상북도 지역에서 분리한 Staphylococcus aureus 병독소 유전자의 분자적 연구)

  • Jeon, Seok-Jae;Lee, Hee-Moo
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.40 no.1
    • /
    • pp.48-54
    • /
    • 2008
  • Nine types of staphylococcal enterotoxin (SE) genes (sea~see, seg~sej), 3 types of virulence genes (eta, etb, tst), mecA and 16S rRNA as internal positive control were detected from 187 clinical MRSA (methicillin resistance Staphylococcus aureus) strains isolated from a variety hospitalized patients in Daegu and Gyeongsangbuk-do areas using the multiplex PCR. The frequency of the S. aureus strains harboring recently reported SE genes (seg~sej) were found to be very high (65.9%) and greater than that of the strains harboring classical SE (sea~see) genes (47.8%) as previously established. Taking into account that the newly described pairs form SE genes (i.e., sec+seg+sei, seg+sei) were many, in the other hand, single form SE genes (i.e., seg, seh, sei and sej) were rarely detected. The S. aureus with pairs form enterotoxigenic genes become more potentially toxigenic strains. Furthermore, this work indicated a systematic association between the seg and sei genes and their high incidence among the S, aureus strains, which suggests that these two SE's could be an important phylogenetic link among the staphylococcal enterotoxins.

  • PDF

Clinical Applications of Chromosomal Microarray Analysis (염색체 Microarray 검사의 임상적 적용)

  • Seo, Eul-Ju
    • Journal of Genetic Medicine
    • /
    • v.7 no.2
    • /
    • pp.111-118
    • /
    • 2010
  • Chromosomal microarray analysis (CMA) enables the genome-wide detection of submicroscopic chromosomal imbalances with greater precision and accuracy. In most other countries, CMA is now a commonly used clinical diagnostic test, replacing conventional cytogenetics or targeted detection such as FISH or PCR-based methods. Recently, some consensus statements have proposed utilization of CMA as a first-line test in patients with multiple congenital anomalies not specific to a well-delineated genetic syndrome, developmental delay/intellectual disability, or autism spectrum disorders. CMA can be used as an adjunct to conventional cytogenetics to identify chromosomal abnormalities observed in G-banding analysis in constitutional or acquired cases, leading to a more accurate and comprehensive assessment of chromosomal aberrations. Although CMA has distinct advantages, there are several limitations, including its inability to detect balanced chromosomal rearrangements and low-level mosaicism, its interpretation of copy number variants of uncertain clinical significance, and significantly higher costs. For these reasons, CMA is not currently a replacement for conventional cytogenetics in prenatal diagnosis. In clinical applications of CMA, knowledge and experience based on genetics and cytogenetics are required for data analysis and interpretation, and appropriate follow-up with genetic counseling is recommended.

Non-invasive Blood Glucose Detection Sensor System Based on Near-Infrared Spectroscopy (근적외선 분광법 기반 비침습식 혈당 검출 센서 시스템)

  • Kang, Young-Man;Han, Soon-Hee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.5
    • /
    • pp.991-1000
    • /
    • 2021
  • Among non-invasive blood glucose detection technologies, the optical technique is a method that uses light reflection, absorption, and scattering characteristics when passing through a biological medium. It reduces pain or discomfort in measurement and has no risk of infection. So it is becoming a major flow of blood glucose detection research. Among them, near-infrared spectroscopy has a disadvantage in that the complexity increases when analyzing signals detected due to interferences between proteins and acids that share a similar absorption function with blood glucose molecules. In this study, a non-invasive sensor system with multiple near-infrared bands was designed and manufactured to alleviate the deterioration of blood glucose detection function that may occur due to skin absorption of near-infrared rays. A blood survey was conducted to verify the system, and the degree of blood glucose response in the blood was collected as spectral data, and the results of this study were quantitatively verified in terms of correlation between the data and blood glucose.

Comparative Evaluation of Loop-Mediated Isothermal Amplification (LAMP) and Conventional PCR for Detection of Shiga-Toxin-Producing Escherichia coli (STEC) in Various Food Products

  • Hyejin Jang;Yong Sun Cho
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.5
    • /
    • pp.347-355
    • /
    • 2023
  • In this study, polymerase chain reaction (PCR) and loop-mediated isothermal amplification (LAMP) were compared in terms of their ability to detect shiga-toxin-producing Escherichia coli (STEC). Various foods were artificially inoculated with STEC to evaluate the limit of detection (LOD), limit of quantification (LOQ), sensitivity, specificity, and efficiency of PCR and LAMP. The LODs were ≤104 and ≤103 CFU/mL for PCR and LAMP, respectively. The LOQs did not differ between PCR and LAMP. However, of the four considered food types, the sensitivities differed by a maximum of 11.1% for seasoned meat and by a minimum of 8.1% for ground beef. LAMP had higher sensitivity than that of PCR and 100% specificity for all four food types. Therefore, LAMP is a reliable molecular method for detecting STEC as comparable to PCR assay, and its specificity and sensitivity are superior to those of PCR, depending on the food type.

Study on the effect of p-type doping in mid-infrared InAs/GaSb superlattice photodetectors

  • Han, Im-Sik;Lee, Yong-Seok;Nguyen, Tien Dai;Lee, Hun;Kim, Jun-O;Kim, Jong-Su;Gang, Sang-U;Choe, Jeong-U;Kim, Ha-Sul;Ku, Zahyun;Lee, Sang-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.170.1-170.1
    • /
    • 2015
  • 안티모니 (Sb)를 기반으로 한 제2형 초격자 (Type II superlattice, T2SL)구조 적외선 검출기 연구는 2000년대 들어 Sb 계열의 화합물 반도체 성장 기술이 발전함에 따라 HgCdTe (MCT), InSb, 양자우물 적외선 검출기 (QWIP)를 대체할 수 있는 고성능의 양자형 적외선 검출 소재로 부상하였으며, 현재 전 세계적으로 활발한 연구가 진행되고 있다. 특히, 기존의 양자형 적외선 검출소자에 비해 전자의 유효질량이 상대적으로 커서 밴드 간의 투과전류가 줄어들 뿐만 아니라, 전자와 정공이 서로 다른 물질 영역에 분포하여 Auger 재결합률을 효과적으로 줄일 수 있어 상온 동작이 가능한 소재로 주목을 받고 있다. 또한, T2SL 구조는 초격자를 구성하는 물질의 두께나 조성 변화를 통한 밴드갭 변조가 용이하여 단파장에서 장파장 적외선에 이르는 광범위한 파장 대역에서 동작이 가능할 뿐만 아니라 구조적 변화를 통해 이중 대역을 동시에 검출 할 수 있는 차세대 적외선 열영상 소자로 알려져 있다. 본 연구에서는 분자선 에피택시(MBE)법을 이용하여 300 주기의 InAs/GaSb (10/10 ML) 제2형 초격자 구조를 성장하여 적외선 검출소자를 제작하였다. 제2형 초격자 구조를 구성하는 물질계에 p-type dopant인 Be을 이용하여 각각 도핑 농도가 다른 시료를 성장하였다. 이때 p-type 도핑 농도는 각각 $1/5/10{\times}10^{15}cm^{-3}$로 변화를 주었다. 성장된 시료의 구조적 특성 분석을 위해 고분해능 X선 회절 (High resolution X-ray diffraction, HRXRD)법을 이용하였으며, 초격자 한 주기의 두께가 6.2~6.4 nm 로 설계된 구조와 동일하게 성장됨을 확인 하였으며, 1차 위성피크의 반치폭은 30~80 arcsec로 우수한 결정성을 가짐을 확인하였다. 적외선 검출을 위한 $410{\times}410{\mu}m^2$ 크기의 단위 소자 공정을 진행하였으며 이때 적외선의 전면 입사를 위해 소자 위에 $300{\mu}m$의 윈도우 창을 제작하였다. 단위 소자의 측벽에는 표면 누설 전류가 흐르는데 이를 방지하기 위해서 표면보호막을 증착하였다. 적외선 검출 소자의 전기적 특성 평가를 위해 각각의 시료의 암전류 (dark current)와 파장별 반응 (spectral response)을 온도별로 측정하여 비교 및 분석하였다.

  • PDF

A study on the derivatization technique for tamoxifen metabolites in human urine by gas chromatography/mass spectrometry (기체크로마토그래피/질량분석기를 이용한 인체 내 뇨시료에서의 Tamoxifen 대사체 검출을 위한 유도체화 연구)

  • Kim, Yunje;Lee, Yoonjung
    • Analytical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.322-336
    • /
    • 2004
  • The improved derivatization technique of tamoxifen metabolite in human urine is described for the acylation method that they are substituted by derivatization reagent like acyl anhydride for use of gas chromatography/mass spectrometry. The hydroxyl group of tamoxifen metabolite was derivatized by trifluoroacetic anhydride (TFAA), pentafluoroacetic anhydride (PFPA) and heptaflorobutylic anhydride (HFBA). It was investigated to the gas chromatography/mass spectrometry (GC/MS) technique use negative ion chemical ionization (NCI), positive ion chemical ionization (PCI) and electron impact (EI). In acylation of the metabolites of tamoxifen, the effective reaction temperature and time were shown to be at $50^{\circ}C$ for 30 min. The 4-hydroxytamoxifen, which is known to major metabolite of tamoxifen, was not detected in human urine, whileas the hydroxymethoxytamoxifen was detected. We thought that this result was from the single dose of tamoxifen.

Optimum Extraction Methods of Volatile Compounds in Beef Extract Powder (쇠고기 엑기스 분말 휘발성 성분의 최적 추출방법에 관한 연구)

  • Kim Hun;Cho Woo-Jin;Jeong Eun-Jeong;Ahn Jun-Suck;Lim Chi-Won;Yoo Young-Jae;Kim Kwang-Ho;Cha Yong-Jun
    • The Korean Journal of Food And Nutrition
    • /
    • v.17 no.4
    • /
    • pp.412-419
    • /
    • 2004
  • In odor to select optimum extraction methods of volatile compounds in beef extract powder(BEP) as basic data for the development of a new detection method of irradiated BEP, four extraction methods, such as solid phase microextraction with polar fiber(S-PD) and non-polar fiber(S-CD), purge and trap(P&T) and liquid liquid continuous extraction(LLCE) methods, were tested with gas chromatography/mass spectrometry method. A total of 106 volatile compounds including 22 hydrocarbons, 7 aldehydes, 6 ketones, 13 alcohols, 6 sulfur-containing compounds, 19 nitrogen-containing compounds, 6 aromatic compounds, 17 terpenes, 8 furans and 2 miscellaneous compounds were detected in BEP by four detection methods. The most compounds(62 compounds) were detected by S-PD method, followed by P&T(43), LLCE(38) and S-CD method(30). Among these methods, S-PD and P&T methods showed a complementary interrelationship to detect volatile compounds as S-PD method showed high detectabiltiy to all compound groups except hydrocarbons and ketones, which had high volatility and low molecular weight(less than RI 1200), but P&T method showed the contrary pattern to that of S-PD method. Moreover, the most of volatile compounds detected by S-CD and LLCE methods were also detectable by S-PD or/and P&T methods. Therefore, the simultaneous application of S-PD and P&T methods were selected as the optimum volatile extraction methods of BEP.

Comparison of Physiological Activities between Hot-Water and Ethanol Extracts of Bokbunja (Rubus coreanum F.) (복분자(Rubus coreanum F.) 열수 및 에탄올추출물의 생리활성비교)

  • Cho, Young-Je;Chun, Sung-Sook;Kwon, Hyo-Jung;Kim, Jeung-Hoan;Yoon, So-Jung;Lee, Kyoung-Hwan
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.6
    • /
    • pp.790-796
    • /
    • 2005
  • Physiological activities of hot-water extract and various concentration ethanol extracts from Bokbunja (Rubus coreanum F. ) were examined. Total phenol content of extract showed higher content in hot-water extract (41.4 mg/g) than other extracts, Optimum condition of extraction for phenolic was $60\%$ ethanol extract (41.3 mg/g). The ABTS radical decolorilization and antioxidant protection factor were determined. Results shown inhibition rate on ABTS of $60\%$ ethanol extract $(99.8\%)$ and antioxidant protection factor of water extract (1.2 PF). Electron donation ability on DPPH was higher 60$\%$ ethanol extract than another percent ethanol extracts. Also hydroxyl radical scavenging activity of extracts was higher $60\%$ ethanol extracts $(0.03\times100\mu\;M)$ than another extracts because the value of TBARS was lower than another extracts. But hot-water extract had higher inhibitory activities on xanthine oxidase and pancreatin $\alpha$ -amylase than $60\%$ ethanol extract. ACE (angiotensin converting enzyme) inhibitory activities were equaled to hot water exract and $60\%$ ethanol extract. Protocatecuic acid was the most abundant phenolic compounds as analyzed by HPLC. The results will be useful as natural antioxidants and functional foods for understanding the physiological activities of Bukbunja extracts.